Franke bremer VIVA Operating Instructions Manual

bremer VIVA
Operating Instructions
Franke Coffee Systems
Automatic Coffee & Cappuccino/Espresso Machine
Dear customer,
before putting your coffee machine into operation, please read the operating instructions carefully. In this way, you protect yourself and you avoid damages to the device.
They contain important information on the correct use of your machine and will enable you to use the coffee machine with the necessary handling.
Always keep these operating instructions to hand.
The coffee machine enables you to prepare
− brewed coffee, coffee specialities without milk
− machine with milk frother as additional feature: for coffee products with milk
− special coffee by adding the ground coffee to the coffee chute
− tea / dispensing of hot water or steam depends on the unit type
− for the commercial use only.
Please use the coffee machine for the preparation of coffee only. Improper use can result in damage to persons and objects.
How does the coffee machine work ?
After a button is pressed, the coffee machine fully automatically brews coffee or coffee specialities cup for cup. The coffee beans are freshly ground for each brewing operation.
After brewing, the dry coffee grounds are scraped off into the grounds container or container ejector.
Key to symbols
. Activities to be carried out
Notes, functional sequences
Reference to other instructions
3
Contents Page
1. Notes on operating safety 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2. Familiarise yourself with the bremer VIVA Coffee Machine 6 . . .
2.1 Set the language for the menue 7 . . . . . . . . . . . . . . . . . . . . . . . . .
3. Switch on the unit 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1 Top up coffee beans 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Provide milk (bremer VIVA with milk frother) 10 . . . . . . . . . . . . . . .
3.3 Prepare and take coffee 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3.1 Preparing single portions (factory setting) 12 . . . . . . . . . . . . . . . .
3.3.2 Set the number of portions − Multiple Selection 13 . . . . . . . . . . . .
3.4 Manual ground coffee metering 14 . . . . . . . . . . . . . . . . . . . . . . . . .
3.5 Manually add milk or milk froth (bremer VIVA with
milk frother) 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6 Emptying the grounds container 16 . . . . . . . . . . . . . . . . . . . . . . . . .
4. Take hot water (additional Feature) 17 . . . . . . . . . . . . . . . . . . . . . .
5. Take steam (additional feature) 18 . . . . . . . . . . . . . . . . . . . . . . . . .
6. Cleaning and care 19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.1 Cleaning the milk system (bremer VIVA with milk frother) 20 . . . .
6.2 Cleaning the brewing unit 22 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3 Cleaning the coffee dispenser 24 . . . . . . . . . . . . . . . . . . . . . . . . . .
6.4 Deliming and cleaning the hot water / steam outlet
(add. feature) 27 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5 Clean coffee bean container and housing 28 . . . . . . . . . . . . . . . . .
7. Switch off / End of operation 29 . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
Contents Page
8. Adjustment, programming 30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.1 Overview of the adjustment possibilities 30 . . . . . . . . . . . . . . . . .
8.2 Display or delete the summing counter 31 . . . . . . . . . . . . . . . . . . .
8.3 Assigning bean container to the article key 32 . . . . . . . . . . . . . . . .
8.4 Adjusting metering quantities for article 33 . . . . . . . . . . . . . . . . . .
8.5 Adjusting the metering quantity hot water" 34 . . . . . . . . . . . . . . .
8.6 Assigning article names to the article key or blocking a key 35 . .
8.7 Adjusting article control (multiple selection) 36 . . . . . . . . . . . . . .
8.8 Changing to turbo operation" 37 . . . . . . . . . . . . . . . . . . . . . . . . . .
8.9 Enter a secret code (PIN) to change settings 38 . . . . . . . . . . . . . . .
8.10 Setting the dispensing sequence 39 . . . . . . . . . . . . . . . . . . . . . . . .
9. Faults and remedies 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10. Technical data 43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11. Setting up and connecting (customer service) 44 . . . . . . . . . . . . .
11.1 Setting up 44 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11.2 Remove protection / Inserting beans container 46 . . . . . . . . . . . .
11.3 Connecting the water supply 47 . . . . . . . . . . . . . . . . . . . . . . . . . . .
11.4 Connecting the water outlet 47 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11.5 Connecting the mains cable 48 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12. Rating plate data / Maintenance 49 . . . . . . . . . . . . . . . . . . . . . . . .
12.1 Maintenance notes 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13. Dismantling, disposal 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
EU Conformity declaration 55 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
1. Notes on operating safety
Operation
D The unit is not a working substance in the sense of the regulations for operating
safety. The operator is responsible for the operation, the risk assessment, and for the repeated tests by authorized persons.
Danger ! Risk of death by electric shock!
D Do not spray the unit with a water hose or high-pressure cleaner. D Do not allow any liquids to flow into the ventilation slits and filling openings. D In the event of operating faults, refer chapter 9. "Faults, remedy" section.
Attention ! If the following notes are not observed, slight injuries or
property damage might result.
D The unit may only be operated
− by trained staff (assigned personnel)
− under supervision
− for the purpose outlined in the operating instructions.
D Do not cover the ventilation vents ! D The unit may only be operated outdoors if covered and if there is sufficient wind
protection. Protect the unit from moisture and direct sunlight.
D The ambient temperature around the unit must not fall below freezing point.
This would cause the water to freeze inside the unit and damage it.
Inspection of the safety equipment in regular intervals
D According to the pressure vessel regulations 97/23/EG and to the regulations
for operating safety the operator is responsible for the careful maintenance and for the inspection of the safety equipment in regular intervals.
D For this reason, the unit should be inspected and serviced once a year by the
authorised Franke customer service.
Extended operating pauses or shut−down of the unit
D Before extended shut−down periods, the cleaning program has to be carried out. D In order to avoid frost damages or in case of risk of freezing, the Franke
customer service has to empty the unit.
6
2. Familiarise yourself with the bremer VIVA Coffee Machine
*Bean container, right
*Bean container, left
Bean container, center
Cover, bean container
Cover for manual ground coffee metering and cleaning agent metering (lockable)
*Steam button
*Steam outlet
Hot water button
Hot water outlet
Grounds drawer
with handle
Keypad cover (lockable)
Coffee dispenser:
Swivelable and
height-adjustable
Unit switch On / OFF (STANDBY)
Scroll backwards in the main menu
Start cleaning program
Confirm loading cleaning tablet /
dosage ground coffee
Article keys:
1 cup
Making the settings / *adding milk froth / *clean the milk suction hose
Delete summing counters
Article keys: 2 cups
Scroll forwards in the main menu
Opening and closing menus
Display and Input Panel
Display panel
*Suction hose for milk
Change settings / *adding milk
Drip tray
Drip grill
COFFEE
SCHÜMLI
ESPRESSO
CAPPUCCINO
Indicator lamps
*Air nozzle
*Milk cooling box (add. feature)
* = Additional feature
* = Additional feature
7
2.1 Set the language for the menue
before switching on
in STANDBY Mode
at the machine
Example: set the language to German
. Press the upper article key on the left hand
side continuously, press at the same time key
or till the requested country
code apears in the display panel
Country code Language 031 Dutch 033 French 044 English 049 German 081 Japanese 095 Russian (add. feature)
. Confirm set country code with key
D Subsequently the setted language is shown
(Summenzähler" = Summing counter) in the display.
. Go to Menü verlassen" (= Exit menu) with
key
. Confirm the setting with key
D The desired language is set. D The machine goes into the STANBY Mode
and stores the new setting.
D In case of power failure or incorrect setting
procedure it is possible to loose applied data.
!!! STANDBY !!!
START
START
081 STANDBY
Country code
Summenzähler
Menü verlassen
!!! STANDBY !!!
8
3. Switch on the unit
. Open the water valve.
. Switch on the electrical mains switch.
D !!! STANDBY !!! appears in the display panel.
. Unlock and open keypad cover with key.
. Switch on the coffee machine by pressing
the on−off
switch.
D Rinsing process runs and boiler is heated up
(approx. 5 minutes).
D The coffee machine is ready for operation
when the green indicator lamps on the buttons light up and when "Ready" is displayed in the display panel.
. Close the keypad cover and remove the key.
3.1 Top up coffee beans
D Top up with only the amount required for the day, because the coffee beans lose
their aroma if they are in the hopper for too long.
D Ensure that no foreign bodies enter the hopper.
!!! STANDBY !!!
lockkeypad
close
open
9
Top up coffee beans
. Unlock the hopper cover with the key and
open it.
. Fill the empty hopper with the required type
of coffee beans.
D If the appliance is equipped with 2 grinders,
it will be possible to use two different sorts of coffee beans.
. Close the hopper after filling it so that the
aroma is preserved.
Display when a hopper is empty
D If the beans container becomes empty
during operation, this is indicated in the display panel, e.g.: "Refil coffee container to centre".
D The corresponding article keys
are
blocked.
D If this message appears during a brewing
operation, it is possible that this brewing operation took place without a sufficient amount of ground coffee. Refill the bean container with coffee beans and repeat the brewing operation.
Confirmation of filling
. Press blocked article key for approx. 5
seconds.
D When the green indicator lamp lights up
again, the coffee machine is ready for brewing.
Cover, beans container
Lock (option)
Refill centre ground container
Example: Beans container
left
(1 kg)
centre
(1.5 kg)
right
(1 kg)
Example:
CAUTION
NOTE
10
3.2 Provide milk (bremer VIVA with milk frother)
Food poisoning by bad milk!
If off milk is used, there will be the risk of food poisoning. For hygienic reasons, the milk has to be replaced in time. Off milk has a foul smell and must not be used.
Observe the hygienic instructions and use only pre−cooled long−life milk.
Fresh milk has to be kept away from light, in cooled conditions at 4 to 8°C, and closed. The life of milk is guaranteed by the indication of the consumption date on the packing.
Please observe that no foreign bodies must come into the milk tank.
Non−cooled milk will be very hot when being doses, this can result in dosage fluctuations and form a skin (clogging). Moreover, there is a risk of burning when tasting.
bremer VIVA with Milk Fridge (add. feature)
D Milk with a fat content of 3,5% is best suited
for frothing.
. Immerse the suction hose for milk into the
milk.
D Make sure that the suction nozzle at the
suction hose stands on the bottom of the milk container. Do not bend the suction hose.
. Close the cooling compartment. D Clean the suction hose two times a day, see
page 20.
Suction nozzle
Suction hose
11
Display at bremer VIVA with Milk Fridge and level sensor detection (add. feature)
D The sensors transmit a signal, after the
minimum supply level is fallen below in the milk container. In the display appears the message.
D If "... empty 00 " is shown in the display the
bremer VIVA proportions no more milk. Coffee products with milk dosage are closed or not selectable.
bremer VIVA with Milk Coolbox (add. feature)
. Immerse the suction hose for milk into the
milk.
D Make sure that the suction nozzle at the
suction hose stands on the bottom of the milk container. Do not bend the suction hose.
D Clean the suction hose two times a day, see
page 20.
When preparing Cappuccino or coffee with milk, milk or milk froth is metered automatically.
Filling milk container, see operating instructions bremer VIVA Milk Fridge.
For the milk quantity settings, see the Chapter "Adjust metering quantities for article", see page 33.
Ready Milk 1 emty 05
example:
Milk container
Number of possible
milk dosages
Suction hose
Milk Coolbox (add. feature)
CAUTION
NOTE
12
3.3 Prepare and take coffee
Risk of scalding by hot coffee !
After completion of the brewing process, the machine automatically serves hot coffee.
Deposit and leave the cup during the process. Do not handle below the coffee outlet.
During coffee production do not pull out the coffee ground tank or the coffee outlet (outlet head), as otherwise malfunction might result.
Set the outlet height of the coffee dispenser
To adapt to various vessel sizes:
Height max. 185 mm
. To adjust the height of the coffee dispenser,
fold away the outlet rocker or push the coffee dispenser up or down.
D When using coffee pots fold the outlet rocker
to the rear till stop (engages).
3.3.1Preparing single portions (factory setting)
. Place cup under the coffee dispenser. D The coffee machine is ready for operation when the green indicator lamps on
the buttons light up and when "Ready" is displayed in the display panel.
. Start the required brewing process by pressing the corresponding article key
D The brewing process is displayed in the display panel, e.g.:
Preparation Coffee cup 1x
D After each withdrawal of a coffee milk product or of milk, the coffee machine
automatically rinses the coffee dispenser.
To change the coffee type and settings, see Page 30, Chapter 8.
Coffee dispensing
Outlet rocker
13
3.3.2Set the number of portions − Multiple Selection
D The standard factory setting of the coffee machine is the preparing of single
portions, see page 12.
D The customer service may adjust the bremer VIVA coffee machine by starting up,
so you can set the number of portions, like following example.
Example: Brewing a pot of coffee − 9 cups
. Place a lot of empty cups under the coffee
dispenser by time.
. Press the article key
as often as is
necessary until the required number of portions is displayed in the display panel, for example 9 times.
D The number of portions is shown in the
display panel and will be counted down during operation / preparation.
Notes for multiple selection
D The first brewing operation begins immediately when the first portion is
selected.
D The display returns to 1" after more than 9" portions are selected.
D An already commenced brewing operation is completed.
D The number of multiple selection should not exceed the number of possible
dosages during the adjusting in that case.
D You can set the "Multiple selection" see Adjusting article control" on page 36,
if the message- and entry field / main menu is not blocked, see page 38.
Preparation Coffee cups 9x
Number of portions
14
3.4 Manual ground coffee metering
D This is for preparing single portions only.
. Place the cup under the coffee dispenser.
. Unlock and open the cover for ground coffee
chute (1)and keypad (2).
. Press the manual ground coffee metering
key.
D The following command appears in the
display:
Put in ground
−>Press prd. key
. Add metered amounts of ground coffee to
the coffee chute
for
1 cup approx. 9 gr.,
for 2 cups approx. 14 gr.
VIVA Barista: for 3 cups approx. 20 gr.
. Start the required brewing process by
pressing the corresponding article key
D The brewing process is displayed in the
display panel, e.g.:
Preparation Coffee cup 1x
. Close both covers and remove the key.
"Manual ground coffee metering" can also be programmed on the article keys, see Chapter "Assigning bean containers to the article key", Page 32.
Cover for ground
coffee chute (1)
Press here to open
Lock (option)
Keypad cover (2)
Lock
Key, manual ground coffee metering
Keypad cover
Cover for ground
coffee chute
15
3.5 Manually add milk or milk froth (bremer VIVA with milk frother)
. Open keypad cover.
D The coffee maker is ready for operation when the green indicator lamps on the
buttons light up.
Manual metering:
Key
for milk froth
Key
for milk
. Keep key
or pressed until desired quantity of milk or milk froth is
dispensed.
D Consider the time of approx. 5 seconds for milkdosage after releasing the key.
D After each additional dosage of milk or milk foam, the bremer VIVA
automatically rinses the coffee dispenser.
Adjust the milk quantity in the Chapter "Adjusting metering quantities for article", see Page 33.
16
3.6 Emptying the grounds container
The bremer VIVA coffee machine counts the number of ejected portions of ground coffee. After the set number of portions is reached, the display signals that the grounds container must be emptied.
The number of portions can be changed by the Franke bremer Customer Service representative (factory setting 80 to 100 portions).
If "Empty grounds container" appears in the display panel,
preparing coffee is no longer possible.
. Remove, empty and clean the grounds
container.
D NOTE: The grounds container must have
been removed for at least 10 seconds so that clearing can occur.
. Insert the grounds container.
D The message "Insert grounds container"
disappears.
If required, the coffee grounds can also be ejected into a container, see table opening for container ejection (add. feature).
Risk of being crushed by the brewing unit !
D Never reach into the open mount after
removing the grounds container.
D Always switch off the machine via the mains
or master switch
before cleaning it.
D The mount should only be wiped with a
damp sponge (do not use a cloth).
D Refit the grounds container after cleaning.
Grounds container
Handle
Mount
for grounds
container
Caution
CAUTION
17
4. Take hot water (additional Feature)
Risk of scalding by hot water!
After pressing the hot water button, the machine automatically dispenses hot water.
Proceed with care. Place cup under Hot water dispenser wait until operation is finished. Do not handle below the hot water outlet.
Hold the hot water outlet pipe at the protective handle (add. feature).
Metered hot water dispensing
D The "metered hot water dispensing" is set at
the factory. If you wish to reset this setting to "unmetered hot water dispensing", inform your Customer Service representative.
. Place the cup under the hot water dispenser.
. Press the
hot water key.
D Hot water is dispensed metered and stops
automatically.
To adjust the metering quantity for metered hot water dispensing, see Page 34, Chapter 8.5.
Unmetered hot water dispensing
. Press the
hot water key, the output
starts - press the
the hot water key
again, dispensing stops.
Hot
water
key
Hot water
dispenser
Loading...
+ 39 hidden pages