The FireGenieTM Remote Control was developed to provide a user-friendly system to use
your appliance. The operating range is approximately 10 metres.
A Quick Reference Sticker is available to be placed on the back of your remote control
handset. Place the sticker close to the very top of the remote, away from the battery
opening and wall mounting bracket.
REMOTE CONTROL KEYPAD
There are 7 push buttons on the Remote Control:
(1) ON/OFF Button: Switches the Remote & Control Box ON or OFF;
(2) “+” Button: This is the INCREMENT or HOUR button;
(3) “-” Button: This is the DECREMENT or MINUTE button;
(4) AUTO/MAN Button: Toggles between Manual, Auto and Program mode;
(5) TIME Button: Initiates the setting of the Time and Day;
(6) PROG Button: Initiates the programming of Auto mode;
(7) FAN Button: Changes the speed of the fan;
(2) “+” Button
(4) Auto/Man Button
(6) Prog Button
(1) On/Off Button
(3) “-” Button
(5) Time Button
(7) Fan Button
FPI FireGenie
TM
Remote Control Manual Page 3
REMOTE CONTROL SCREEN DISPLAY (LCD)
The LCD provides the following display features:
1. Flame Height Indication (6 different flame heights);
10. Fan Speed Indication (3 different fan speeds);
11. Time of Day with AM, PM;
Page 4 FPI FireGenieTM Remote Control Manual
QUICK REFERENCE
OF BASIC FUNCTIONS
For the remote to function it must be turned ON. However when the remote is OFF, the
LCD continues to display the current day, time and room temperature.
Switching the Remote ON & OFF
The On/Off button is used to switch the Remote ON or OFF.
If the Remote is switched OFF, pressing and releasing the On/Off button will switch ON
the Remote (and the FireGenieTM Control Box). Once switched ON, the Remote will
continue with its last selected operating mode, for example, Manual, Auto or Program
mode.
Setting Time & Day
Note: The remote needs to be ON in order to set the Time & Day.
Time
Press and hold the “TIME” button for 2 seconds and then use the “+” button to set
the hour and use the “-” button to set the minute.
Day
Press the “TIME” button again and use the “+” or “-” button to set the day.
FPI FireGenie
TM
Remote Control Manual Page 5
Manual & Auto Mode
b
Press the “Auto/Man” button to toggle from Auto, Manual & Program mode. See
“Setting the Program Mode” for details on Program Mode.
Manual
In Manual Mode using the “+” or “-” button allows you to adjust the flame height
accordingly. There are six different levels of flame settings.
Use the “Fan” button to adjust the fan speed. There are 3 different fan speed
settings.
Auto
In Auto Mode using the “+” or “-” button allows you to change the Set
Temperature.
Use the “Fan” button to adjust the fan speed. There are 3 different fan speed
settings.
Displaying Temperature in Celsius or Fahrenheit
The default setting of the Remote is to display the temperature in Celsius.
However, the Remote can be changed to display temperature in Fahrenheit by the
following steps:
1. Ensure the Remote is switched off by using the On/Off button.
2. Press and hold the “-” button.
3. While the “-” button is held down, press and release the “+”
toggle the temperature display between °C and °F.
This setting is stored in memory hence the Remote will continue to display the
temperature in Fahrenheit even if the battery is replaced.
utton, this will
Page 6 FPI FireGenieTM Remote Control Manual
MANUAL MODE
Manual mode can be selected by pressing and releasing the AUTO/MAN button until the
symbol “MANUAL” is shown on the LCD.
In Manual mode, the Fan speed and Flame settings can be adjusted independently using
the Remote.
FAN Speed Adjustment
The FAN button is used to switch on and change the selected fan speed.
If the Fan is off, pressing and releasing the FAN button once will turn the fan on at Low
speed.
Pressing and releasing the FAN button again will change the speed to Medium.
Pressing and releasing the FAN button again will change the speed to High.
Pressing and releasing the FAN button again will switch the Fan OFF.
** Only on select models. Some models (GF Series) require the fan on at all times.
The display on the LCD will be as follows:
Fan on Low Speed Fan on Medium
Speed
Fan on High Speed Fan = OFF
FPI FireGenie
TM
Remote Control Manual Page 7
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.