FoxGate C704, C708 Installation Manual

Page 1
C700 series
Chassis Core Routing Switch
Installation Manual
(v1.6)
Page 2
1
Preface
C700 serial switch is a high performance routing switch released by Digitalchina network that can be deployed as the core layer device for campus and enterprise networks, or as an aggregation device for IP metropolitan area networks (MAN). C700 serial switch provides 4 and 10 slots, with support for various types of line cards and can seamlessly support a variety of network interfaces from 100Mb, 1000Mb to 10GB Ethernet.
We are providing this manual for your better understanding, use and maintenance of the C700. We strongly recommend you to read through this manual carefully before installation and configuration to avoid possible malfunction or damage to the switch. Furthermore, we sincerely hope our products and services satisfy you.
Page 3
2
FCC - Class A
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.
You may use unshielded twisted-pair (UTP) for RJ-45 connections - Category 3 or better for 10 Mbps connections, Category 5 or better for 100 Mbps connections, Category 5, 5e, or 6 for 1000 Mbps connections. For fiber optic connections, you may use 50/125 or
62.5/ 125 micron multimode fiber or 9/125 micron single-mode fiber.
Page 4
C700 InstallManual Content
3
Content
CHAPTER 1 PRODUCT OVERVIEW ........................................ 1-1
1.1 PRODUCT BRIEF ................................................................................. 1-1
1.1.1 Introduction ............................................................................................. 1-2
1.1.2 Main Features .......................................................................................... 1-2
1.2 TECHNICAL SPECIFICATIONS ................................................................. 1-2
1.3 PHYSICAL SPECIFICATIONS .................................................................. 1-6
1.4 HARDWARE COMPONENTS ................................................................... 1-6
1.4.1 Chassis ..................................................................................................... 1-6
1.4.2 Introduction to C700 Series Cards ......................................................1-12
1.4.3 Interface description .............................................................................1-47
1.4.4 Power supply .........................................................................................1-49
1.4.5 Power Distribution Box ........................................................................1-55
1.4.6 System Backplane ................................................................................1-58
1.4.7 Fan Tray ..................................................................................................1-58
1.4.8 Dust Gauze.............................................................................................1-60
1.4.9 Rear Panel ..............................................................................................1-61
1.4.10 Side Panels ..........................................................................................1-63
1.5 SYSTEM FEATURES ........................................................................... 1-65
1.5.1 C704 System Features ..........................................................................1-65
1.5.2 C708 System Features ..........................................................................1-66
CHAPTER 2 HARDWARE INSTALLATION ............................... 2-1
2.1 BASIC REQUIREMENTS ........................................................................ 2-1
2.1.1 Site Requirements ................................................................................... 2-1
2.1.2 Temperature and Humidity Requirements ........................................... 2-1
2.1.3 Dust and Particles ................................................................................... 2-2
2.1.4 Preventing Electrostatic Discharge Damage ....................................... 2-3
2.1.5 Anti-interference Requirements ............................................................ 2-3
2.1.6 Rack Configuration ................................................................................. 2-3
2.1.7 Power Supply Requirements ................................................................. 2-4
2.2 SAFETY GUIDELINES ........................................................................... 2-5
2.3 SAFETY WARNING ............................................................................... 2-5
2.4 HOT LINE WORK SAFETY GUIDELINES .................................................. 2-5
2.5 PREPARING FOR INSTALLATION ............................................................. 2-6
2.5.1 Checking Switch Hardware Configuration and Accessories ............. 2-6
2.5.2 Required Tools and Utilities ................................................................... 2-7
2.6 HARDWARE INSTALLATION ................................................................... 2-8
2.6.1 Switch Installation ................................................................................... 2-8
2.6.2 Switch grounding .................................................................................. 2-11
Page 5
C700 InstallManual Content
4
2.6.3 Card and module installation ...............................................................2-12
2.6.4 Connecting to the Console ..................................................................2-18
2.6.5 Connecting to the Management Port ..................................................2-19
2.6.6 SFP transceiver installation .................................................................2-19
2.6.7 Copper Cable/Fiber Cable Connection ...............................................2-20
2.6.8 Power supply connection ....................................................................2-21
Page 6
C700 InstallManual Chapter 1 Product Overview
1-1
Chapter 1 Product Overview
RECOMMENDATION: Please read this manual first before using the switch, following the instructions to avoid damaging the device.
1.1 Product Brief
FIG 1-1 C704 Switch
FIG 1-2 C708 Switch
Page 7
C700 InstallManual Chapter 1 Product Overview
1-2
1.1.1 Introduction
FoxGate C700 series is a high performance routing switch that can be deployed as a core layer device for campus and enterprise networks, or an aggregation device for IP metropolitan area networks (MAN).
C704 provides 4 slots, 3 or 2 of which are interface module slots. C708 provides 10 slots, 8 of which are interface module slots. C700 series supports various types of line cards, and can seamlessly support network interfaces from 100Mb, 1000Mb to 10GB Ethernet. Featuring functions such as policy-based routing, IPv6, and load balance, it is capable of flexibly meeting the different requirements of complex customer environments. Furthermore, C700 series allows redundancy for management modules, power supply. It supports both AC-input and DC-input* power supplies, with hot-swapping support for cards, power supplies and fans. The working temperature of all cards can be monitored in real-time, offering carrier-class reliability.
1.1.2 Main Features
C704 4 slots that can be configured in Primary controller-Primary Backup mode
with 2 management modules and 2 network modules, or Single controller mode with one management module and 3 network modules.
C708 10 slots that can be configured in Primary controller-Primary Backup mode with
2 management modules and 8 network modules, or Single controller mode with one management module and 8 network modules.
Store-and-forward switching, ensuring minimal latency. Auto MDI/MDI-X, enabled on all RJ-45 ports, allows connections to other switches
using a non-crossover twisted pair cable.
Full-duplex IEEE802.3x flow control, half-duplex backpressure flow control. Console management port provided. Port working status and statistics available. Restart and reset to factory setting can be done both locally and remotely. TFTP /FTP firmware upgrade available. Can be installed into standard 19-inch chassis.
1.2 Technical specifications
Item
C704
C708
Page 8
C700 InstallManual Chapter 1 Product Overview
1-3
Slot
4
10
Port
10/100/1000BASE-T, 192 at best 1000Base-SX, 192 at best 1000Base-LX, 192 at best 10/100BASE-T, 192 at best 10GBase, at best
10/100/1000BASE-T, 384 at best 1000Base-SX, 384 at best 1000Base-LX, 384 at best 10/100BASE-T, 384 at best 10GBase, at best
Backboard bandwidth
1.2Tbps(can extend to 2.4Tbps)
2.4Tbps(can extend to 4.8Tbps)
Exchange capacity
640Gbps
1.28Tbps/2.4Tbps (the second generation engine)
Packet Forwarding Speed
476Mpps
952Mpps/1785Mpps (the second generation engine)
Forwarding Delay Time among Ports
<=6ms
<=6ms VLAN Item
4K
4K
Layer 2 Protocol Specifications
IEEE802.3(10Base-T), IEEE802.3u(100Base-TX), IEEE802.3z1000BASE-X, IEEE802.3ab1000Base-T, IEEE802.3ae10GBase, IEEE802.1Q(VLAN), IEEE802.3ak(10GBASE-CX4), IEEEE802.1d(STP), IEEEE802.1W(RSTP), IEEEE802.1S(MSTP), IEEE802.1p(COS), IEEE802.1x(Port Control), IEEE802.3xFlow control, IEEE802.3ad(LACP), Port Mirror, RSPAN, ULDP , LLDP, IGMP Snooping, QinQ, GVRP,VLAN, PVLAN, VOICE VLAN, Protocol Vlan, Multicast VLAN, Mac Vlan, Broadcast Storm Control
Layer 3 Protocol Specifications (IPv4)
Support ARP, ARP Proxy, ARP Limiting Speed, ARP Repeat-Authentication, Gratuitous ARP Support DNS client
Support Static Routing, RIPv1/v2, OSPFv2, BGP4, GRE Unicast Routing Protocol
etc.
Support Routings for OSPF‟s different process import each other Support LPM Routing, Policy-based Routing(PBR), ECMP Support VRRP, URPF, Black Hole Routing
Support IGMP v1/2/3, DVMRP, PIM-DM, PIM-SM, PIM-SSM, IGMP Proxy,
anycast RP, MSDP, Static multicast Routing, boundary multicast Routing etc.
Strengthen
Extend
Support in-embed firewall, IDS, IPSce VPN, Content-exchange service, Network
Analysis hardware module etc.
Free-Resource
Support
Page 9
C700 InstallManual Chapter 1 Product Overview
1-4
IPv6
Support ICMPv6, ND, DNSv6 Support IPv6 LPM Routing, IPv6 Policy-based Routing(PBR) Support IPv6 VRRPv3, IPv6 URPF, IPv6 Black Hole Routing
Support RIPng, OSPFv3, BGP4+ Unicast Routing Protocol etc.
Support 6to4 Tunnels, configured Tunnels, ISATAP etc.
Support MLD Snooping, IPv6 Muticast VLAN
Support MLDv1/v2, PIM-SM/DM for IPv6, IPv6 anycast RP, IPv6 Static multicast
Routing, IPv6 boundary multicast Routing, IPv6 multicast tunnel etc.
Support IPv6 ACL, IPv6 QOS
Strengthen
ARP/NDP Safety
function
Support ARP/NDP Spoofing Prevention, ARP/NDP Scanning Prevention
MPLS
MPLS, LDP, MPLS VPN, MPLS TE, Access public network technology
QoS
Carry out by hardware completely, have no effect for performance.
Each port has 8 queues. Support SP, WRR, SWRR queue scheduling algorithm.
Support traffic class base on 802.1p, ToS, port, DiffServ
Class traffic by ACL, configure the COS, TOS, DSCP bases class result. Class
traffic by high-layer content for ACL-X‟s 80 bytes
Support SP, WRR, SWRR etc. Provide different service quality requested for
speech, data and video transmit at the same network.
Support Traffic Shaping
Support priority Mark/Remark
ACL
Carry out by hardware completely, have no effect for forwarding performance. Support Standard ACL and Extended ACL Support IP ACL, base on IP-subnet ACL, MAC ACL, IP-MAC ACL Support IP or MAC based on source/destination, Layer 3 IP protocol type,
TCP/UDP layer 4 port number, IP priority (DSCP, ToS, Precedence), base on
VLAN, Tag/Untag, CoS etc. Support REDIRECT based on ACL, Traffic statistic based on ACL
ACL-X
Support to transfer security policy automatically base on time.
ACL‟s deepness content can be used for QoS sort standard, the deepness can
extend 80 bytes.
DCSCMv4/v6
Support IPv4/IPv6 Multicast Source Controllable, Prevent lawless Multicast
Source
Support IPv4/IPv6 multicast user Controllable
Support IPv4/IPv6 policy multicast
Page 10
C700 InstallManual Chapter 1 Product Overview
1-5
Port Function
Support MAC+ port binding, IP+ MAC+ port binding, IP+ port binding
Support MAC filter
Support Port Limitbandwidth management
Support Port Loopback Detection
Support Port Mirror CPU Port Mirror, ingress or egress unilateralism/
bidirectional, one-to-one, many-to-one, stride board, stride equipment,
Support Flow Control HOL prevent head-packet block, half-duplex back
pressure, full-duplex IEEE802.3x
Support Port aggregation IEEE802.3adLACP, port-to-port GEC/FEC, each
trunk can up to 8 ports, support load equipoise
DHCPv4/v6
Support IPv4/IPv6 DHCP Client, IPv4/IPv6 DHCP Relay, IPv4/IPv6 DHCP
Snooping
Inside-install IPv4/IPv6 DHCP Server, DHCP Option82
Security Access
Support IEEE 802.1x, DCSM
AAA
Authentication
Support IPv4/IPv6 RADIUS
Security Function
Configuration
Support IPv4/IPv6 syslog
Support the unite for IPv4/IPv6 HTTP and SSL
Support the user IP security inspection for IPv4/IPv6 SNMP
Support MIB and TRAP
Support IPv4/IPv6 FTP/TFTP
Support IPv4/IPv6 NTP
Support RMOM 1, 2, 3, 9 four group
Support the RADIUS authentication for IPv4/IPv6 telnet user name and password
Support IPv4/IPv6 SSHs
The right configuration for users can adopt radius server‟s shell management
Support the function for timing-reset bases needs
sFlow Function
Support network flow analysis,Support RFC3176,can realize the flow monitoring
and statistic based on protocol or address
IPFIX
A standard protocol can measure the flow information of the IETE network
Exception
monitoring and
fault check-up
Monitoring the Task exception, Memory exception, CPU utilance, Stack
exception, Switching-chip exception, board temperature exception etc. And
giving an alarm
Centralized Web
Management
Software
It is adopted the FoxGate centralized web management software „LinkManager‟
for unified management.
Page 11
C700 InstallManual Chapter 1 Product Overview
1-6
1.3 Physical Specifications
Management Port
One RJ-45 serial port for each management module
AC Power Input
Input: 110~240V, 50 ~ 60Hz Built-in Universal Power Supply
DC Power Input
Input: -36V~ -72V. Output: 12V/25A, 5V/10A Built-in Universal Power Supply
Power Consumption
C704: 400W Max C708: 1200W Max
Operating Temperature
0C ~ 40C
Storage Temperature
-40C ~ 70C
Relative humidity
10% ~ 90% with no condensate
Dimension
C704 445mm×266mm×421mm (W x H x D) C704(V2.0 above) 440mm×266mm×421mm (W x H x D) C708 436mm×797mm×478mm (W x H x D)
Weight
C704: 30kg (max. full configuration weight) C708: 65kg (max. full configuration weight)
Mean Time Before Failure
Min. 80,000 Hours MTBF
1.4 Hardware Components
C704 consists of the chassis, power supply system, ventilation system, system
board, etc.
1.4.1 Chassis
1.4.1.1 C704 Chassis
Page 12
C700 InstallManual Chapter 1 Product Overview
1-7
The C704 uses a 19-inch Rack Mountable Chassis, with the standard dimensions of 445mm(W) x 266(H) x 421mm(D),the C704(V2.0 above) with the dimensions of 440mm(W) x 266mm(H) x 421mm(D). The chassis consists of functional block and power supply block. The function module block is a board rack, which is the supporting structure for C704 system boards (4 boards max). The fan block is located on the left side of the board rack, allowing one fan tray (4 axial fans for each fan tray). Dust gauze is provided on the right of the board rack for filtering air circulation through the rack. The power block upper the dust gauze provides power to the system, supporting up to two power modules. The power modules insert into the power slots from the front, with the distribution box at the back of the rack for maintenance. In addition, there is an ESD Wrist Strap Connectors on the board rack, located on the left side of the upper.
Fig 1-3 C704 Module Outlook
Page 13
C700 InstallManual Chapter 1 Product Overview
1-8
Fig 1-4 C704 Front Panel View
Management slot: It supports two management slots.
C704-M-S4C24(V2.1) or C704-M-X12 etc.can be inserted in to the Management slots.The second slot can also be used as I/O slot for
configuring various I/O modules, such as C700-C12 , C700-S12 C700-X4 and more.
Network slot: 2 network slots are provided. Various network modules
can be added to the network slots.
Power slot: Used for system power supply modules. Supports up to
two 400W AC modules.
Fan tray slot: Supports up to one system fan assemblies, each
assembly consists of four axial fans.
Dust gauze slot: Exterior air inlet for the ventilation subsystem. Distribution box slot: For system distribution box use, works in AC
mode based on the power modules.
1.4.1.1.1 Board Rack
The board rack consists of board slots and a system board.
The boards are inserted vertically into the C704 4 unit boards are provided. There are four slots in C704 from number 1 to number 4 in order of top to down. The first slot is used to install management module; the second slot is used to management module under 1+1 redundant backup mode or install various I/O interface modules.
A reset button (printed on the panel as Reset), hot swap button (printed on the panel
Page 14
C700 InstallManual Chapter 1 Product Overview
1-9
as SWAP), board power indicator (printed on the panel as PWR) and board running status indicator (printed on the panel as RUN) are provided for each board. On the Main Control cards there is Master-Slave indicator (printed on the panel as M/S) There is also a power module status indicator (printed on the panel as Power), fan assembly status indicator (printed on the panel as Fan), and interface status indicators for corresponding management interfaces and network interfaces (printed on the panel as Link and Act).
The C704 system board is an essential part of the switch, located inside the switch and providing interconnectivity between the management switch modules (short for management card) and network interface modules (line card), and for all management and control signals.
1.4.1.1.2 Power Supply
When using A.C. power supply, we shall adopt power supply of 200~264v and corresponding A.C. distribution box. The permissible range of power supply is ±20%, 50Hz~60Hz. The maximum output power of single power supply module is 400W.
1.4.1.1.3 Ventilation and Cooling System
The operating ambient temperature of the C704 is 0 ~ 45C, the thermal design of the equipment can ensure that the surface temperature of the device will not exceed the 50C to 80C, the highest temperature allowable.
The switch uses fan assemblies to disperse heat, with the air flow being drawn in through the right section and out through the left section to facilitate air circulation, so that the switch can maintain normal operation under specified environmental conditions. The fan tray is attached to the fan tray slots left the board rack, and ventilation is provided via 4 axial fans that pump out air. Fan trays are hot swappable for maintenance, their status are indicated by the FAN indicators on the main switch panel. In addition, dust gauze is provided on the right of the board rack for filtering the air circulating through the rack. The dust gauze can be unplugged and removed through the back for maintenance.
1.4.1.2 C708 Chassis
The C708 uses a 19-inch Rack Mountable Chassis, with the standard dimensions of
436mm(W) x 797mm(H) x 478mm(D). The chassis consists of functional block, thermal
block, and power supply block. The function module block is a board rack, which is the supporting structure for C708 system boards (10 boards max). Ten wiring clips are provided in the upper and lower parts of the board rack respectively, for the positioning of all kinds of cables. In addition, there are two ESD Wrist Strap Connectors on the board rack, located on the left side of the upper and lower rack respectively. The thermal block is
Page 15
C700 InstallManual Chapter 1 Product Overview
1-10
located on the upper part of the board rack, allowing three fan trays (2 axial fans for each fan tray). Dust gauze is provided under the board rack for filtering air circulation through the rack. The power block under the dust gauze provides power to the system, supporting up to three power modules. The power modules insert into the power slots from the front, with the distribution box at the back of the rack for maintenance. Closely beside the distribution box, a grounding post has been provided on each side of the rack for grounding connections. In addition, on both sides of the lower section of the chassis, a handler is provided for easier transport.
Fig 1-5 C708 Front Panel view
Management slot: 2 management slots are provided. One or two
management switching modules C708-M can be inserted in to the Management slots.
Page 16
C700 InstallManual Chapter 1 Product Overview
1-11
Network slot: 8 network slots are provided. Various network modules
can be added to the network slots, such as C700-C12, C700-S12, C700-X4, etc.
Power slot: used for system power supply modules. Supports up to
three 600W AC modules or three 600W DC modules.
Fan tray slot: Supports up to three system fan assemblies, each
assembly consists of two axial fans.
Dust gauze slot: exterior air inlet for the ventilation subsystem. Distribution box slot: For system distribution box use, works in AC/DC
mode based on the power modules.
1.4.1.2.1 Board Rack
The board rack consists of board slots and a system board.
The boards are inserted vertically into the C708 10 unit boards are provided. These include 2 management slots in the middle for management switch modules, marked specially in red as M1 and M2. The other eight board slots are network slots for various network interface modules, sequenced as 1 to 8 from left to right.
A reset button (printed on the panel as Reset), hot swap button (printed on the panel as SWAP), board power indicator (printed on the panel as PWR) and board running status indicator (printed on the panel as RUN) are provided for each board. On the Main Control cards there is Master-Slave indicator (printed on the panel as M/S) There is also a power module status indicator (printed on the panel as Power: Fail/OK), fan assembly status indicator (printed on the panel as Fan: Alarm/OK), and interface status indicators for corresponding management interfaces and network interfaces (printed on the panel as Link and Act). The C708 system board is an essential part of the switch, located inside the switch and providing interconnectivity between the management switch modules (short for management card) and network interface modules (line card), and for all management and control signals.
1.4.1.2.2 Power Supply
When powered by AC sources, the 110V/220 VAC input power supplies and corresponding AC distribution box should be used. The acceptable input power ranges from 90 ~ 264 VAC at 50 ~ 60 Hz. The maximum output power of each power module is 600W.
Page 17
C700 InstallManual Chapter 1 Product Overview
1-12
When powered by DC sources, the -48 VDC input power supply and corresponding DC distribution box should be used. The acceptable input power ranges from -36 V ~ 72 VDC. The maximum output power of each power module is 600W.
1.4.1.2.3 Ventilation and Cooling System
The operating ambient temperature of the C708 is 0 ~ 40C, the thermal design of the equipment can ensure that the surface temperature of the device will not exceed the 50C to 80C, the highest temperature allowable.
The switch uses fan assemblies to disperse heat, with the air flow being drawn in through the bottom section and out through the upper section to facilitate air circulation, so that the switch can maintain normal operation under specified environmental conditions. Three fan trays are attached to the fan tray slots above the board rack, and ventilation is provided via 6 axial fans that pump out air. Fan trays are hot swappable for maintenance, their status are indicated by the FAN indicators on the main switch panel. In addition, dust gauze is provided under the board rack for filtering the air circulating through the rack. The dust gauze can be unplugged and removed through the front for maintenance.
1.4.2 Introduction to C700 Series Cards
The following eleven cards for the C700 series are currently available: Main control card(C704-M-X12): The central switching and controlling module
for the C704, System status control, switch management, user access control and administration, and network operation maintenance are performed here. 12 Gigabit SFP ports are also provided.
Main control cardC704-M-S4C24(V2.1)): The central switching and
controlling module for the C704, System status control, switch management, user access control and administration, and network operation maintenance are performed here. 24 10/10Base-TX ports with 4 Gigabit combo ports (RJ45or SFP) are also provided.
Main control card (C708-M): The central switching and controlling module for the
C708. System status control, switch management, user access control and administration, and network operation maintenance are performed here.
12 copper GT ports line card (C700-C12): supporting 12 1000Base-T copper
ports for layer 2 and layer 3 switching and routing.
12 fiber GB ports line card (C700-S12): supporting 12 fiber GB fiber ports for
layer 2 and layer 3 switching and routing.
Page 18
C700 InstallManual Chapter 1 Product Overview
1-13
8 Gigabit Combo ports and 16 fiber GB ports line card(C700-S24C8): supporting
8 Gigabit Combo and 16 fiber GB ports for layer 2 and layer 3 switching and routing; ipv6 wire speed forward.
Dual 10G XFP ports , 8 Gigabit Combo ports and 16 fiber GB ports line card
(C700-X2S24C8): supporting 2 10G XFP ports, 8 Gigabit Combo and 16 fiber GB port for layer 2 , layer 3 switching and routing and ipv6 wire speed forward
4 Gigabit Combo ports and 24 100/10 Base-TX ports line card (C700-S4C24):
supporting 4 Gigabit Combo ports and 24 100/10 Base-TX ports for layer 2 and layer 3 switching and routing.
12 Gigabit Combo ports and 12 copper GT ports (C704-M-X1S12C24):
supporting 12 Gigabit Combo ports and 12 copper GT ports for layer 2 and layer 3 switching and routing and ipv6 wire speed forward.
Dual 10G XFP ports , 12 Gigabit Combo ports and 12 copper Gb ports
(C700-X2S12C12): supporting dual 10G XFP ports, 12 Gigabit Combo ports and 12 copper GT ports for layer 2 and layer 3 switching , routing and IPv6 wire speed forward.
48 copper GT ports line card (C700-C48): supporting 48 1000Base-T copper
ports for layer 2 and layer 3 switching and routing and IPv6 wire speed forward.
Main control card (C704-M-X1S12C24): The central switching and controlling
module for the C704, System status control, switch management, user access control and administration, and network operation maintenance are performed here. The board can be inserted into first or second slots of the chassis for Master-Slave redundancy, and supports IPv6 wire speed transmission function. 12-port 1G optical-electronic combo, 12-port 1G electronic and 1-port 10G XFP interface.
40G XFP interface line card (C700-X4): implements 2-layer and 3-layer
wire-speed switching and routing function of 4 10,000Mbps XFP interfaces and IPv6 wire-speed transmission.
48 copper GT ports line card (C700-S48): implements 2-layer and 3-layer
wire-speed switching and routing function of 48 1000Mbps optical interfaces and IPv6 wire-speed transmission.
Main control card (C704-M-C44): The switching module of the C704 switch.
System status control, switch management, user access control and management, and network maintenances are performed here. The board can be inserted into first or second slots of the chassis for Master-Slave redundancy, supports IPv6 wire-speed transmission. It has 44 1000Mbps electronic interfaces at the same time.
Page 19
C700 InstallManual Chapter 1 Product Overview
1-14
Main control card (C704-M-X1S24C12): is switching module for the C704.
System status control, switch management, user access control and management, and network maintenances are performed here. The board can be inserted into first or second slots of the chassis for Master-Slave redundancy. C704-M-X1S24C12 supports 2-layer and 3-layer wire-speed switching and routing function of 12 1000Mbps optical-electronic combos, 12 1000Mbps opticals and 1 10,000Mbps XFP interfaces, IPv6 wire-speed transmission.
12 1000Mbps optical-electronic combo, 12 1000Mbps optical interfaces line
card(C700-S24C12): The switching module of the 76 series switch and implements 2-layer and 3-layer wire-speed switching and routing function of 12 1000Mbps optical-electronic combo, 12 1000Mbps optical interfaces, IPv6 wire-speed transmission.
12 1000Mbps optical-electronic combo, 12 1000Mbps optical and 2 10,000Mbps
XFP interfaces line card (C700-X2S12C12): The switching module of the 76 series switch and implements 2-layer and 3-layer wire-speed switching and routing function of 12 1000Mbps optical-electronic combo, 12 1000Mbps optical and 2 10,000Mbps XFP interfaces, IPv6 wire-speed transmission.
Dual 10G XFP ports , 12 Gigabit Combo ports and 12 copper Gb ports
(C700-X2S12C12(R4)): supporting dual 10G XFP ports, 12 Gigabit Combo ports and 12 copper GT ports for layer 2 and layer 3 switching , routing and IPv6 wire speed forward.
12 Gigabit Combo ports and 12 copper Gb ports (C704-M-X1S12C24(R4)):
supporting 12 Gigabit Combo ports and 12 copper GT ports for layer 2 and layer 3 switching , routing and IPv6 wire speed forward.
48 copper GT ports line card (C700-S48(R4)): implements 2-layer and 3-layer
wire-speed switching and routing function of 48 1000Mbps optical interfaces and IPv6 wire-speed transmission.
Main control card (C704-M-X1S12C24(R4)): The central switching and
controlling module for the C704, System status control, switch management, user access control and administration, and network operation maintenance are performed here. The board can be inserted into first or second slots of the chassis for Master-Slave redundancy, and supports IPv6 wire speed transmission function. 12-port 1G optical-electronic combo, 12-port 1G electronic and 1-port 10G XFP interface.
Main control card (C708-M(R4): The central switching and controlling module
for the C708. System status control, switch management, user access control and administration, and network operation maintenance are performed here.
1.4.2.1 C704-M-X12
Page 20
C700 InstallManual Chapter 1 Product Overview
1-15
The C704-M-X12 is switching module for the C704. System status control, switch management, user access control and administration, and network maintenances are performed here. The board can be inserted into first or second slots of the chassis for Master-Slave redundancy. 12 Gigabit SFP ports are also provided.
1.4.2.1.1 Front Panel
The C704-M-X12 provides 12 1000Base-SFP ports. At the same time, it comes with 1 Console port (control console) and 1 10/100Base-Tx Ethernet port (management port). The Front Panel view is shown below:
Fig 1-6 C704-M-X12 Front Panel View
1.4.2.1.2 Front Panel - Indicator
The following table describes the front panel indicators of C704-M-X12:
Table 1-1 C704-M-X12 indicators description
LED
Panel Symbol
Status
Description
Power
Indicator
PWR
On (Green)
Card powered
Off
Card powered off
Operation
indicator
RUN
On (Green, blink at 1 Hz)
Cards operating normally
On (Green, blink at 8 Hz)
System is loading
On (Yellow, blink at 8 Hz)
System is shutting down) On (Red, blink at 8 Hz)
Cards malfunction
Off
Cards are powered off and can be removed
Master-Slave
indicator
M/S
On (Green)
Master
Off
Slave
Fan Assembly
OK
On (Green)
Fan operating normally
Page 21
C700 InstallManual Chapter 1 Product Overview
1-16
Status
indicator:
FAN
Off
Fan malfunctioning or not present (with Alarm off)
SFP port indicator
Status
indicator
Link
On (Green)
Network connection on SFP transceiver is normal
Off
No network connection present on SFP transceiver
Transmission
Indicator
Act
Blinking (Green)
Sending or receiving data
1.4.2.1.3 Front Panel Port Description
The C704-M-X12 provides 12 SFP (Mini GBIC) Gigabyte fiber transceiver slots.
The following SFP transceivers are supported by the C704-M-X12:
SFP-SX-L Gigabit SFP MM 850 nm, 500m (SX) SFP-LX-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-20-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-40-L Gigabit SFP SM 1310 nm, 40Km (LHX) SFP-LH-70-L Gigabit SFP SM 1550 nm, 70Km (ZX) SFP-LH-120-L Gigabit SFP SM 1550 nm, 120Km (ZX) SFP-GT Gigabit SFP to Copper cable RJ45
1.4.2.1.4 Front Panel – Console Port
The C704-M-X12 provides a RJ-45 (receptacle) Console serial port. Users can connect to hosts via this port to perform system debugging, configuration, maintenance, management and host software loading.
Table 1-2 C704-M-X12 Console description
Property
Specification
Connector
RJ-45 (receptacle)
Connector type
RS-232
Baud rate
9600bps (default)
Supporting service
Connects to character terminals Connects to PC serial port and running terminal emulator
on PC.
Page 22
C700 InstallManual Chapter 1 Product Overview
1-17
1.4.2.1.5 Front Panel – Management Port
The C704-M-X12 provides a RJ-45 (receptacle) Ethernet port. Users can connect through this management port to hosts for program loading or to connect to remote devices for remote management (e.g., a managing workstation). Note: when connecting to the host, a cross-over cable should be used.
Table 1-3 C704-M-X12 management port description
Property
Specification
Connector
RJ-45 (Receptacle)
Connector type
10/100Mbps auto sensing Cat 5 UTP: 300 m
1.4.2.1.6 Front Panel – Reset Button
C704-M-X12 provides a RESET button for resetting the board.
1.4.2.2 C704-M-S4C24
The C704-M-S4C24 is switching module for the C704. System status control, switch management, user access control and management, and network maintenances are performed here. The board can be inserted into first or second slots of the chassis for Master-Slave redundancy. 24 10/10Base-TX ports with 4 Gigabit combo ports (RJ45or SFP) are also provided.
1.4.2.2.1 Front Panel
The C704-M-S4C24 provides 24 10/100Base-TX ports and 4 Gigabit COMBO slots. At the same time, it comes with 1 Console port (control console) and 1 10/100Base-Tx Ethernet port (administration port).
The Front Panel view is shown below:
Fig 1-7 C704-M-S4C24
1.4.2.2.2 Front Panel - Indicator
The following table describes the front panel indicators of C704-M-S4C24:
Table 1-4 C704-M-S4C24 indicators description
LED
Panel Symbol
Status
Description
Page 23
C700 InstallManual Chapter 1 Product Overview
1-18
Power
Indicator
PWR
On (Green)
Card powered
Off
Card powered off
Operation
indicator
RUN
On (Green, blink at 1 Hz)
Cards operating normally
On (Green, blink at 8 Hz)
System is loading
On (Yellow, blink at 8 Hz)
System is shutting down
On (Red, blink at 8 Hz)
Cards malfunction
Off
Cards are powered off and can be removed
Master-Slave
indicator
M/S
On (Green)
Master
Off
Slave
Fan Assembly
Status
indicator:
FAN
FAN
On (Green)
Fan operating normally
On (Red)
Fan malfunctioning
Off
Fan not present (with Alarm off)
SFP port indicator
Status
indicator
Link
On (Green)
Network connection on SFP transceiver is normal
Off
No network connection present on SFP transceiver
Transmission
Indicator
Act
Blinking (Green)
Sending or receiving data
10/100Base-RJ45 port indicator
Status
indicator
Link
On (Green)
Network connection is normal
Off
No network connection present on 10/100Base-RJ45 port
Transmission
Indicator
Act
Blinking (Green)
Sending or receiving data
1000Base-TX port indicator
Status
indicator
Link
On (Green)
Network connection on 1000Base-TX transceiver is normal
Off
No network connection present on 1000Base-TX transceiver
Transmission
Indicator
Act
Blinking (Green)
Sending or receiving data
Page 24
C700 InstallManual Chapter 1 Product Overview
1-19
1.4.2.2.3 Front Panel Port Description
The E C704-M-S4C24 provides 24 10/100Base-TX ports and 4 Gigabite COMBO (RJ-45 or SFP) transceiver slots.
The following SFP transceivers are supported by the C704-M4GX2 4TX:
SFP-SX-L Gigabit SFP MM 850 nm, 500m (SX) SFP-LX-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-20-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-40-L Gigabit SFP SM 1310 nm, 40Km (LHX) SFP-LH-70-L Gigabit SFP SM 1550 nm, 70Km (ZX) SFP-LH-120-L Gigabit SFP SM 1550 nm, 120Km (ZX) SFP-GT Gigabit SFP to Copper cable RJ45
1.4.2.2.4 Front Panel – Console Port
The C704-M-S4C24 provides a RJ-45 (receptacle) Console serial port. Users can connect to hosts via this port to perform system debugging, configuration, maintenance, management and host software loading.
Table 1-5 C704-M-S4C24 Console description
Property
Specification
Connector
RJ-45 (receptacle)
Connector type
RS-232
Baud rate
9600bps (default)
Supporting service
Connects to character terminals Connects to PC serial port and running terminal emulator
on PC.
1.4.2.2.5 Front Panel – Management Port
The C704-M-S4C24 provides a RJ-45 (receptacle) Ethernet port. Users can connect through this management port to hosts for program loading or to connect to remote devices for remote management (e.g., a managing workstation). Note: when connecting to the host, a cross-over cable should be used.
Table1-6 C704-M-S4C24 management port description
Property
Specification
Connector
RJ-45 (Receptacle)
Connector type
10/100Mbps auto sensing Cat 5 UTP: 300 m
1.4.2.2.6 Front Panel – Reset Button
Page 25
C700 InstallManual Chapter 1 Product Overview
1-20
C704-M-S4C24 provides a RESET button for resetting the board.
1.4.2.3 C708-M
The C708-M is switching module for the C708. System status control, switch management, user access control and management, and network maintenances are performed here. The board can be inserted into M1 or M2 slots of the chassis for Master-Slave redundancy.
1.4.2.3.1 Front Panel
The C708-M comes with 1 Console port (control console) and 1 10/100Base-Tx Ethernet port (management port).
The Front Panel view is shown below:
Fig 1-8 C708-M Front Panel view
1.4.2.3.2 Front Panel - Indicator
The following table describes the front panel indicators of C708-M:
Table 1-7 C708-M indicators description
LED
Panel Symbol
Status
Description
Power
Indicator
PWR
On (Green)
Card powered
Off
Card powered off
Operation
indicator
RUN
On (Green, blink at 1 Hz)
Cards operating normally
On (Green, blink at 8 Hz)
System is loading
On (Yellow, blink at 8 Hz)
System is shutting down
On (Red, blink at 8 Hz)
Cards malfunction
Off
Cards are powered off and can be removed
Master-Slav
e indicator
M/S
On (Green)
Master
Off
Slave
Page 26
C700 InstallManual Chapter 1 Product Overview
1-21
Power
Supply
Module
Status
indicator:
POWER
OK
On (Green)
Power Supply Module operating normally
Off
Power supply module malfunctioning or not present (with Fail off)
Fail
On (Yellow)
Power Supply Module malfunction
Off
Power supply module operating normally or not present (with OK off)
Fan
Assembly
Status
indicator:
FAN
OK
On (Green)
Fan operating normally
Off
Fan malfunctioning or not present (with Alarm off)
Alarm
On (Yellow)
Fan malfunction
Off
Fan operating normally or not present (with OK off)
1.4.2.3.3 Front Panel – Console Port
The C708-M provides a RJ-45 (receptacle) Console serial port. Users can connect to hosts via this port to perform system debugging, configuration, maintenance, management and host software loading.
Table 1-8 C708-M Console description
Property
Specification
Connector
RJ-45 (receptacle)
Connector type
RS-232
Baud rate
9600bps (default)
Supporting service
Connects to character terminals Connects to PC serial port and running terminal emulator
on PC.
1.4.2.3.4 Front Panel – Management Port
The C708-M provides a RJ-45 (receptacle) Ethernet port. Users can connect through this management port to hosts for program loading or to connect to remote devices for remote management (e.g., a managing workstation). Note: when connecting to the host, a cross-over cable should be used.
Table 1-9 C708-M management port description
Property
Specification
Page 27
C700 InstallManual Chapter 1 Product Overview
1-22
Connector
RJ-45 (Receptacle)
Connector type
10/100Mbps auto sensing Cat 5 UTP: 300 m
1.4.2.3.5 Front Panel – Reset Button
C708-M provides a RESET button for resetting the board.
1.4.2.4 C700-C12
12 copper GT ports line card (C700-C12): supports 12 1000Base-T copper ports for layer 2 and layer 3 switching and routing.
1.4.2.4.1 Front Panel
C700-C12 provides 12 RJ45 ports (10/100/1000Mbps adaptive). The Front Panel view is shown below:
Fig 1-9 C700-C12 Front Panel view
1.4.2.4.2 Front Panel - Indicator
The following table describes the C700-C12‟s front panel indicators:
Table 1-10 C700-C12 indicator descriptions
LED
Panel
Symbol
Status
Description
Power
Indicator
PWR
On (green)
Card powered
Off
Card powered off
Operation
indicator
RUN
On (Green, blinks at 1 Hz)
Card operating normally
On (Green, blinks at 8 Hz)
System is loading
On (Yellow, blinks at 8 Hz)
System is shutting down
On (Red, blinks at 8 Hz)
Malfunction status
Off
Card is powered off and can be removed
RJ-45 port indicator
Status
Link
On (Green)
Network connection is normal
Page 28
C700 InstallManual Chapter 1 Product Overview
1-23
indicator
Off
No network connection present on 1000Base-TX port
Transmissio
n Indicator
Act
Blinking (Green)
Sending or receiving data
1.4.2.4.3 Front Panel Port Description
The C700-C12 provides 12 RJ45 copper GT ports.
Table 1-11 C700-C12 port description
Port Type
Specification
RJ-45 port
10/100/1000 Mbps auto sensing MDI/MDI-X cable ant sensing Cat 5 UTP: 100 m
1.4.2.4.4 Front Panel – Reset Button
The C700-C12 provides a RESET button for resetting the board.
1.4.2.5 C700-S12
12 fiber GB ports line card (C700-S12): supports 12 SFP GB fiber ports for layer 2 and layer 3 switching and routing.
1.4.2.5.1 Front Panel
C700-S12 provides 12 SFP ports. The Front Panel view is shown below:
Fig 1-10 C700-S12 Front Panel view
1.4.2.5.2 Front Panel - Indicator
The following table describes the C700-S12‟s front panel indicators:
Table 1-12 C700-S12 indicator descriptions
LED
Panel
Symbol
Status
Description
Power
Indicator
PWR
On (green)
Card powered
Off
Card powered off
Operation
indicator
RUN
On (Green, blinks at 1 Hz)
Cards operating normally
On (Green, blinks at 8 Hz)
System is loading
Page 29
C700 InstallManual Chapter 1 Product Overview
1-24
On (Yellow, blinks at 8 Hz)
System is shutting down
On (Red, blinks at 8 Hz)
Malfunction status
Off
Cards is powered off and can be removed
SFP port indicator
Status
indicator
Link
On (Green)
Network connection on SFP transceiver is normal
Off
No network connection present on SFP transceiver
Transmissio
n Indicator
Act
Blinking (Green)
Sending or receiving data
1.4.2.5.3 Front Panel Port Description
The C700-S12 provides 12 SFP (Mini GBIC) Gigabyte fiber transceiver slots.
The following SFP transceivers are supported by the C700-S12:
SFP-SX-L Gigabit SFP MM 850 nm, 500m (SX) SFP-LX-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-20-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-40-L Gigabit SFP SM 1310 nm, 40Km (LHX) SFP-LH-70-L Gigabit SFP SM 1550 nm, 70Km (ZX) SFP-LH-120-L Gigabit SFP SM 1550 nm, 120Km (ZX) SFP-GT Gigabit SFP to Copper cable RJ45
1.4.2.5.4 Front Panel – Reset Button
The C700-S12 provides a RESET button for resetting the board.
1.4.2.6 C700-S24C8 and C700-X2S24C8
C700-S24C8 line card: supporting 8 gigabit combo ports and 16 fiber GB ports for layer2 and layer3 switching and routing and IPv6 wire speed forward.
C700-X2S24C8 line card: supporting dual 10G XFP ports, 8 gigabit combo ports and 16 fiber GB ports for layer2 and layer3 switching and routing and IPv6 wire speed forward.
1.4.2.6.1 Front Panel Diagram
C700-S24C8 provides eight GT electronic ports, twenty four GB optical SFP ports, where the eight 1G electronic ports and the first eight 1G optical ports are combo ports.
Page 30
C700 InstallManual Chapter 1 Product Overview
1-25
Fig 1-11 C700-S24C8 front panel view
C700-X2S24C8 provides two 10G XFP ports, eight 1G electronic ports, twenty four 1G optical SFP ports, where the eight 1G electronic ports and the first eight 1G optical ports are combo ports.
Fig 1-12 C700-X2S24C8 front panel view
1.4.2.6.2 Front Panel Indicator
The description of front panel indicator of C700-S24C8 and C700-X2S24C8 is as follows:
Table 1-13 C700-S24C8 and C700-X2S24C8 indicator description
LED
Indicator
Panel
Sign
Status
Meanings
Power Indicator
PWR On (Green)
Network Interface Card power on
Off
Network Interface Card power off
Running Indicator
RUN
On (Green 1Hz flash)
Network Interface Card running in normal status
On (Green 8Hz flash)
System loading (Network Interface Card Booting after hot plug in)
On (Yellow 8Hz flash)
System shutting down
On (Red 8Hz flash)
Running status is in failure
Off
Network Interface Card is off and can be pulled out
RJ-45 Interface indicator
Status Indicator
“Left Light”
On (Green)
RJ-45 Interface Network Connection is normal
Off
There is not network connection at RJ-45 interface
Transmissio n Indicator
“Right Light”
Flashed (Green)
Sending or receiving data
SFP Interface Indicator
Status
“Left Light”
On (Green)
SFP transceiver network connection is normal
Page 31
C700 InstallManual Chapter 1 Product Overview
1-26
Indicator Off
There is not network connection at SFP transceiver
Transmissio n Indicator
“Right Light”
Flashes (Green)
Sending or receiving data
XFP Interface Indicator
Status Indicator
Link On (Green)
XFP transceiver network connection is normal
Off
There is not network connection at XFP transceiver
Transmissio n Indicator
Act
On (Green)
Sending or receiving data
1.4.2.6.3 Front Panel Interface Description
C700-S24C8 and C700-X2S24C8 provide eight RJ-45 1G electronic ports, twenty four SFP 1G optical fibre transceiver slots.
C700-X2S24C8 provides two XFP 10G electronic ports.
C700-S24C8 and C700-X2S24C8 support the followings SFP transceiver:
C700-S24C8 and C700-X2S24C8 support SFP transceivers of the following types:
SFP-SX-L Gigabit SFP MM 850 nm, 500m (SX) SFP-LX-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-20-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-40-L Gigabit SFP SM 1310 nm, 40Km (LHX) SFP-LH-70-L Gigabit SFP SM 1550 nm, 70Km (ZX) SFP-LH-120-L Gigabit SFP SM 1550 nm, 120Km (ZX) SFP-GT Gigabit SFP to Copper cable RJ45
C700-X2S24C8 supports XFP transceivers of the following types:
XFP-SR XFP 10G Transceiver XFP-LR XFP 10G Transceiver 20KM XFP-ER XFP 10G Transceiver 40KM XFP-ER-70 XFP 10G Transceiver 70KM
1.4.2.6.4 Front Panel RESET Button
C700-S24C8 and C700-X2S24C8 both provide a RESET button to reset the panel.
1.4.2.7 C700-S4C24
C700-S4C24 is the line card exchange model of C700 series exchanges. It
Page 32
C700 InstallManual Chapter 1 Product Overview
1-27
implements the layer2 and layer3 wire speed exchange and routing function of twenty four 10/100M electronic ports and four 1G COMBO (4 10/100/1000M electronic interfaces or four 1G optical interfaces).
1.4.2.7.1 Front Panel Diagram
C700-S4C24 provides twenty four 10/100M electronic ports and four 1G COMBO.
Fig 1-13 C700-S4C24 front panel view
1.4.2.7.2 Front Panel Indicator
The description of front panel indicator of C700-S4C24 is as follows:
Table 1-14 C700-S4C24 indicator description
Indicator
Panel
Sign
Status
Meanings
Power
Indicator
PWR
On (Green)
Network Interface Card power on
Off
Network Interface Card power off
Running Indicator
RUN
On (Green 1Hz flash)
Network Interface Card running in normal status
On (Green 8Hz flash)
System loading (Network Interface Card Booting after hot plug in)
On (Yellow 8Hz flash)
System shutting down On (Red 8Hz flash)
Running status is in failure
Off
Network Interface Card is off and can be pulled out
SFP Interface indicator
Status
Indicator
Link
On (Green)
SFP transceiver network connection is normal
Page 33
C700 InstallManual Chapter 1 Product Overview
1-28
Off
There is not network connection at SFP transceiver
Transmissio
n Indicator
Act
Flashes (Green)
Sending or receiving data 100MB electronic port indicator
Status Indicator
Link
On (Green)
100MB electronic port transceiver network connection is normal
Off
There is not network connection at 100MB electronic port transceiver
Transmissio
n Indicator
Act
Flashes (Green)
Sending or receiving data 1GB Electronic Port Indicator
Status
Indicator
Link
Flashes (Green)
1GB electronic port transceiver network connection is normal
Off
There is not network connection at 1GB electronic port transceiver
Transmissio
n Indicator
Act
Flashes (Green)
Sending or receiving data
1.4.2.7.3 Front Panel Interface Description
C700-S4C24 provides twenty four 10/100M and four 1G COMBO.
Where 1G optical electronic port, C700-S4C24 supports SFP transceivers of the following types:
SFP-SX-L Gigabit SFP MM 850 nm, 500m (SX) SFP-LX-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-20-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-40-L Gigabit SFP SM 1310 nm, 40Km (LHX) SFP-LH-70-L Gigabit SFP SM 1550 nm, 70Km (ZX) SFP-LH-120-L Gigabit SFP SM 1550 nm, 120Km (ZX) SFP-GT Gigabit SFP to Copper cable RJ45
1.4.2.7.4 Front Panel RESET Button
Page 34
C700 InstallManual Chapter 1 Product Overview
1-29
C700-S4C24 provides a RESET button to reset the panel.
1.4.2.8 C704-M-X1S12C24 and C700-X2S12C12
12-port optical-electronic combo and 12-port electronic interface line card (C704-M-X1S12C24): to implement the layer2 and layer3 wire speed exchange and routing function of 12-port 1G optical-electronic combo and 12-port 1G electronic interface and IPv6 wire speed transmission function.
Double 10G and 12-port optical-electronic combo and 12-port electronic interface line card (C700-X2S12C12): to implement the layer2 and layer3 wire speed exchange and routing function of 12-port 1G optical-electronic combo, 12-port 1G electronic and 2-port 10G XFP interface, and IPv6 wire speed transmission function.
1.4.2.8.1 Front Panel Diagram
C704-M-X1S12C24 provides twelve 1G SFP ports, twenty four 1G electronic ports, where the twelve 1G optical ports and the last twelve 1G electronic ports are combo ports.
Fig 1-14 C704-M-X1S12C24 front panel view
C700-X2S12C12 provides two 10G XFP ports, twelve 1G optical SFP ports, twenty four 1G electronic SFP ports, where the twelve 1G optical ports and the last twelve 1G electronic ports are combo ports.
Fig 1-15 C700-X2S12C12 front panel view
1.4.2.8.2 Front Panel Indicator
The description of front panel indicator of C704-M-X1S12C24 and C700-X2S12C12 is as follows:
Table 1-15 C704-M-X1S12C24 and C700-X2S12C12 indicator description
LED
Indicator
Panel
Sign
Status
Meanings
Power Indicator
PWR On (Green)
Network Interface Card power on
Off
Network Interface Card power off
Page 35
C700 InstallManual Chapter 1 Product Overview
1-30
Running Indicator
RUN
On (Green 1Hz flash)
Network Interface Card running in normal status
On (Green 8Hz flash)
System loading (Network Interface Card Booting after hot plug in)
On (Yellow 8Hz flash)
System shutting down
On (Red 8Hz flash)
Running status is in failure
Off
Network Interface Card is off and can be pulled out
RJ-45 Interface indicator
Status Indicator
Shared
On (Green)
RJ-45 Interface Network Connection is normal
Off
There is not network connection at RJ-45 interface
Transmissio n Indicator
On (Yellow)
Sending or receiving data
SFP Interface Indicator
Status Indicator
“Left Light”
On (Green)
SFP transceiver network connection is normal
Off
There is not network connection at SFP interface
Transmissio n Indicator
“Right Light”
Flashes (Green)
Sending or receiving data
XFP interface Indicator
Status Indicator
Link On (Green)
XFP transceiver network connection is normal
Off
There is not network connection at XFP transceiver
Transmissio n Indicator
Act
Flashes (Green)
Sending or receiving data
1.4.2.8.3 Front Panel Interface Description
C704-M-X1S12C24 and C700-X2S12C12 provide twelve SFP 1G optical fibre transceivers and twenty four RJ-45 1G electronic port slots.
C700-X2S12C12 provides two XFP 10G optical ports.
C704-M-X1S12C24 and C700-X2S12C12 support SFP transceivers of the following types:
SFP-SX-L Gigabit SFP MM 850 nm, 500m (SX) SFP-LX-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-20-L Gigabit SFP SM 1310 nm, 10Km (LX)
Page 36
C700 InstallManual Chapter 1 Product Overview
1-31
SFP-LX-40-L Gigabit SFP SM 1310 nm, 40Km (LHX) SFP-LH-70-L Gigabit SFP SM 1550 nm, 70Km (ZX) SFP-LH-120-L Gigabit SFP SM 1550 nm, 120Km (ZX) SFP-GT Gigabit SFP to Copper cable RJ45
C700-X2S12C12 supports XFP transceivers of the following types:
XFP-SR XFP 10G Transceiver XFP-LR XFP 10G Transceiver 20KM XFP-ER XFP 10G Transceiver 40KM XFP-ER-70 XFP 10G Transceiver 70KM
1.4.2.9 C700-C48
48GT electronic interface line card (C700-C48): to implement the layer2 and layer3 wire speed exchange and routing function of 48GT electronic interface and IPv6 wire speed transmission function.
1.4.2.9.1 Front Panel Diagram
C700-C48 provides 48-Port 10/100/1000M Ethernet electronic ports,
Fig 1-16 C700-C48 front panel view
1.4.2.9.2 Front Panel Indicator
The description of front panel indicator of C700-C48 as follows:
Table 1-16 C700-C48 indicator description
LED
Indicator
Panel
Sign
Status
Meanings
RJ-45 Interface indicator
Status Indicator
Shared
On (Green)
RJ-45 Interface Network Connection is normal
Off
There is not network connection at RJ-45 interface
Transmissio n Indicator
On (Yellow)
Sending or receiving data
1.4.2.9.3 Front Panel Interface Description
Page 37
C700 InstallManual Chapter 1 Product Overview
1-32
C700-C48 provides 48-port 10/100/1000M RJ-45 electronic port.
All kinds of interface description are as follows
Table 1-17 C700-C48 interface description
Interface Format
Specs
RJ-45 port
10/100/1000Mbps self-adapting MDI/MDI-X network wire type self-adapting 5 kinds of Unshielded Twisted Pair(UTP): 100
metres
1.4.2.10 C704-M-X1S12C24
The C704-M-X1S12C24 is switching module for the C704. System status control, switch management, user access control and management, and network maintenances are performed here. The board can be inserted into first or second slots of the chassis for Master-Slave redundancy. 12-port 1G optical-electronic combo, 12-port 1G electronic and 2-port 10G XFP interface, and IPv6 wire speed transmission function.
1.4.2.10.1 Front Panel Diagram
C704-MIXFP12GX12GT provides 2-port 1G optical-electronic combo, 12-port 1G electronic and 2-port 10G XFP interface.
1.4.2.10.2 Front Panel Indicator
The description of front panel indicator of C704-M-X1S12C24 as follows:
Table 1-18 C704-M-X1S12C24 indicator description
LED
Indicator
Panel
Sign
Status
Meanings
Power Indicator
PWR On (Green)
Network Interface Card power on
Off
Network Interface Card power off
Running Indicator
RUN
On (Green 1Hz flash)
Network Interface Card running in normal status
On (Green 8Hz flash)
System loading (Network Interface Card Booting after hot plug in)
On (Yellow 8Hz flash)
System shutting down
On (Red 8Hz flash)
Running status is in failure
Page 38
C700 InstallManual Chapter 1 Product Overview
1-33
Off
Network Interface Card is off and can be pulled out
RJ-45 Interface indicator
Status Indicator
Shared
On (Green)
RJ-45 Interface Network Connection is normal
Off
There is not network connection at RJ-45 interface
Transmissio n Indicator
On (Yellow)
Sending or receiving data
SFP Interface Indicator
Status Indicator
“Left Light”
On (Green)
SFP transceiver network connection is normal
Off
There is not network connection at SFP interface
Transmissio n Indicator
“Right Light”
Flashes (Green)
Sending or receiving data
XFP interface Indicator
Status Indicator
Link On (Green)
XFP transceiver network connection is normal
Off
There is not network connection at XFP transceiver
Transmissio n Indicator
Act
Flashes (Green)
Sending or receiving data
1.4.2.10.3 Front Panel Interface Description
C704-M-X1S12C24 provides 12-port 1G optical-electronic combo, 12-port 1G electronic and 2-port 10G XFP interface.
C704-M-X1S12C24 support SFP transceivers of the following types:
SFP-SX-L Gigabit SFP MM 850 nm, 500m (SX) SFP-LX-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-20-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-40-L Gigabit SFP SM 1310 nm, 40Km (LHX) SFP-LH-70-L Gigabit SFP SM 1550 nm, 70Km (ZX) SFP-LH-120-L Gigabit SFP SM 1550 nm, 120Km (ZX) SFP-GT Gigabit SFP to Copper cable RJ45
C704-M-X1S12C24 supports XFP transceivers of the following types:
XFP-SR XFP 10G Transceiver XFP-LR XFP 10G Transceiver 20KM
Page 39
C700 InstallManual Chapter 1 Product Overview
1-34
XFP-ER XFP 10G Transceiver 40KM XFP-ER-70 XFP 10G Transceiver 70KM
1.4.2.11 C700-X4
C700-X4implements 2-layer and 3-layer wire-speed switching and routing function of 4 10,000Mbps XFP interfaces and IPv6 wire-speed transmission.
1.4.2.11.1 Front Panel Diagram
The following is the sketch map of its front panel:
Fig 1-17 the Sketch Map of the Front Panel of C700-X4
1.4.2.11.2 Front Panel Indicator
The following is the instruction of the indicator lamps on the front panel of C700-X4.
Table 1-19 the Instruction of Indicator Lamps of C700-X4
LED
Indicator
Panel
Sign
State
Explanation
Power Indicator Lamp
PWR On(green)
The boardcard is power-on
Off
The boardcard is power-off
Run Operating Indicator
RUN On green,
glittering at the frequency of 1 HZ
The boardcard is operating normally
On green, glittering at the frequency of 8 HZ
The system is bootingBooting after the boardcard is hot-plugged in
Off
The boardcard is operating abnormally
XFP Interface Indicator Lamps
State Indicator Lamp
Link On(green)
The network connection of XFP Transceiver is normal.
Off
There is no network connection on XFP Transceiver
Transmissio n Indicator
Act
On(green)
Receiving or sending data.
Page 40
C700 InstallManual Chapter 1 Product Overview
1-35
Lamp
1.4.2.11.3 Front Panel Interfaces Description
C700-X4provides 4 10,000Mbps XFP electric interfaces.
1.4.2.12 C700-S48
48-port 1000Mbps optical line cardC700-S48: Implements 2-layer and 3-layer wire-speed switching and routing function of 48 1000Mbps optical interfaces, and IPv6 wire-speed transmission.
1.4.2.12.1 Front Panel Diagram
C700-S48 provides 48 1000Mbps optical interfaces.
The following is the sketch map of its front panel:
Fig 1-18 the Sketch Map of the Front Panel of C700-S48
The ports in the above chart are port GB1GB48 from the bottom-left corner to the top-right corner. The indicator lamps of ports having odd index number are on the left side of the port array, while the indicator lamps of ports having even index number are on the right side. The lamps are green indicator lamps.
1.4.2.12.2 Front Panel Indicator
The following is the instruction of the indicator lamps on the front panel of C700-S48.
Table 1-20 the Instruction of Indicator Lamps of C700-S48
LED
Indicator
Panel
Sign
State
Explanation
SFP Interface Indicator Lamps
State Indicator Lamp
On(green)
The network connection of SFP interface is normal.
Off
There is no network connection on SFP interface
Transmissio n Indicator Lamp
On(green)
SFP is receiving or sending data.
Page 41
C700 InstallManual Chapter 1 Product Overview
1-36
1.4.2.12.3 Front Panel Interface Description
C700-S48 provides 48 SFP1000Mbps optical transceiver interfaces.
1.4.2.13 C704-M-C44
The C704-M-C44 is switching module for the C704 switch. System status control, switch management, user access control and management, and network maintenances are performed here. The board can be inserted into first or second slots of the chassis for Master-Slave redundancy, supports IPv6 wire-speed transmission. It has 44 1000Mbps electronic interfaces at the same time.
1.4.2.13.1 Front Panel Diagram
C704-M-C44 implements 2-layer and 3-layer wire-speed switching and routing function of 44 1000Mbps electronic interfaces and IPv6 transmission.
The following is the sketch map of its front panel:
Fig 1-19 the Sketch Map of the Front Panel of C704-M-C44
1.4.2.13.2 Front Panel Indicator
The following is the instruction of the indicator lamps on the front panel of C704-M-C44.
Table1-21 C704-M-C44 indicator description
LED
Panel
Symbol
Status
Description
Power
Indicaor
PWR
On(Green)
Card Powered
Off
Card Powered off
Master-Slave
Indicator
M/S
On(Green)
Master
Off
Slave
Fan
Indicator
FAN
On(Green)
Operating normally
Off
Operating abnormally
Operation
Indicator
RUN On(Green, blink at 1 Hz
Cards operating normally
On(Green, blink at 8 Hz
System is loading Booting after the boardcard is hot-plugged in
Off
Operating malfunctioning
Page 42
C700 InstallManual Chapter 1 Product Overview
1-37
RJ-45 Interface Indicator
Port
indicator
On(Green)
The network connection of RJ-45 interface is normal
Off
There is no network connection on RJ-45 interface
On(Orange)
Receiving or sending data
1.4.2.13.3 Front Panel Interface Description
C704-M-C44 provides 44-port 10/100/1000M RJ-45 electronic port.
1.4.2.14 C704-M-X1S24C12
The C704-M-X1S24C12 is switching module for the C704. System status control, switch management, user access control and management, and network maintenances are performed here. The board can be inserted into first or second slots of the chassis for Master-Slave redundancy. C704-M-X1S24C12 supports 2-layer and 3-layer wire-speed switching and routing function of 12 1000Mbps optical-electronic combos, 12 1000Mbps opticals and 1 10,000Mbps XFP interfaces, IPv6 wire-speed transmission.
1.4.2.14.1 Front Panel Diagram
C704-M-X1S24C12 provides 12-port 1G optical-electronic combo, 12-port 1G optical and 1-port 10G XFP interface. 12-port 1G optical-electronic are combo at the front, 12-port are 1G optical interface at the back.
The following is the sketch map of its front panel:
Fig 1-20 the Sketch Map of the Front Panel of C704-M-X1S24C12
1.4.2.14.2 Front Panel Indicator
The following is the instruction of the indicator lamps on the front panel of C704-M-X1S24C12.
Table1-22 C704-M-X1S24C12 indicator description
LED
Panel
Symbol
Status
Description
Power
Indicaor
PWR
On(Green)
Card Powered
Off
Card Powered off
Page 43
C700 InstallManual Chapter 1 Product Overview
1-38
Master-Slave
Indicator
M/S
On(Green)
Master
Off
Slave
Fan
Indicator
FAN
On(Green)
Fan operating normally
Off
Fan not present or operating abnormally
Operation
Indicator
RUN On(Green, blink at 1 Hz
Cards operating normally
On(Green, blink at 8 Hz
System is loading Booting after the boardcard is hot-plugged in
Off
Operating malfunctioning
RJ-45 Interface Indicator
Port
Indicator
On(Green)
The network connection of RJ-45 interface is normal
Off
There is no network connection on RJ-45 interface
On(Orange)
Receiving or sending data
SFP Interface Indicator
Status Indicator
“Left
Light”
On (Green)
SFP transceiver network connection is normal
Off
There is not network connection at SFP interface
Transmission Indicator
“Right
Light”
On (Green)
Sending or receiving data XFP Interface Indicator
Status Indicator
Link On (Green)
XFP transceiver network connection is normal
Off
There is not network connection at XFP transceiver
Transmission Indicator
Act
On (Green)
Sending or receiving data
1.4.2.14.3 Front Panel Interface Description
C704-M-X1S24C12 provides 24 SFP 1000Mbps optical fibre transceivers, 12 RJ-45
1000Mbps electronic port slots and 1 XFP 10,000Mbps electronic port.
1.4.2.15 C700-S24C12 and C700-X2S12C12
The C700-S24C12 is switching module for the 76 series switch and implements
2-layer and 3-layer wire-speed switching and routing function of 12 1000Mbps
Page 44
C700 InstallManual Chapter 1 Product Overview
1-39
optical-electronic combo, 12 1000Mbps optical interfaces, IPv6 wire-speed transmission.
The C700-X2S12C12 is switching module for the 76 series switch and implements 2-layer and 3-layer wire-speed switching and routing function of 12 1000Mbps optical-electronic combo, 12 1000Mbps optical and 2 10,000Mbps XFP interfaces, IPv6 wire-speed transmission.
1.4.2.15.1 Front Panel Diagram
C700-S24C12 provides 12 1000Mbps optical-electronic combo and 12 1000Mbps optical interfaces. 12 1000Mbps electronic ports are combo ports at the front, 12 ports are 1000Mbps optical port at the back.
The following is the sketch map of its front panel:
Fig 1-21 the Sketch Map of the Front Panel of C700-S24C12
The C700-X2S12C12 provides 12 1000Mbps optical-electronic combo, 12 1000Mbps optical interfaces and 2 10,000Mbps XFP interfaces. 12 1000Mbps electronic ports are combo ports at the front, 12 ports are 1000Mbps optical ports at the back.
The following is the sketch map of its front panel:
Fig 1-22 the Sketch Map of the Front Panel of C700-X2S12C12
1.4.2.15.2 Front Panel Indicator
The following is the instruction of the indicator lamps on the front panel of C700-S24C12 and C700-X2S12C12.
Table1-23 C700-S24C12 and C700-X2S12C12 indicator description
LED
Panel
Symbol
Status
Description
Power
Indicaor
PWR
On(Green)
Card Powered
Off
Card Powered off
Operation
Indicator
RUN On(Green, blink at 1 Hz
Cards operating normally
On(Green, blink at 8 Hz
System is loading Booting after the boardcard is hot-plugged in
Off
Operating malfunctioning
Page 45
C700 InstallManual Chapter 1 Product Overview
1-40
RJ-45 Interface Indicator
Port
Indicator
On(Green)
The network connection of RJ-45 interface is normal
Off
There is no network connection on RJ-45 interface
On(Orange)
Receiving or sending data
SFP Interface Indicator
Status Indicator
“Left
Light”
On (Green)
SFP transceiver network connection is normal
Off
There is not network connection at SFP interface
Transmission Indicator
“Right
Light”
On (Green)
Sending or receiving data XFP Interface Indicator
Status Indicator
Link On (Green)
XFP transceiver network connection is normal
Off
There is not network connection at XFP transceiver
Transmission Indicator
Act
On (Green)
Sending or receiving data
1.4.2.15.3 Front Panel Interface Description
C700-S24C12 and C700-X2S12C12 provides 24 SFP 1000Mbps optical fibre
transceivers, 12 RJ-45 1000Mbps electronic port slots.
C700-X2S12C12 provides 2 XFP 10,000Mbps optical ports.
1.4.2.16 C704-M-X1S12C24(R4) and C700-X2S12C12(R4)
12-port optical-electronic combo and 12-port electronic interface line card (C704-M-X1S12C24(R4)): to implement the layer2 and layer3 wire speed exchange and routing function of 12-port 1G optical-electronic combo and 12-port 1G electronic interface and IPv6 wire speed transmission function.
Double 10G and 12-port optical-electronic combo and 12-port electronic interface line card (C700-X2S12C12(R4)): to implement the layer2 and layer3 wire speed exchange and routing function of 12-port 1G optical-electronic combo, 12-port 1G electronic and 2-port 10G XFP interface, and IPv6 wire speed transmission function.
1.4.2.16.1 Front Panel Diagram
C704-M-X1S12C24(R4) provides twelve 1G SFP ports, twenty four 1G electronic ports, where the twelve 1G optical ports and the last twelve 1G electronic ports are combo
Page 46
C700 InstallManual Chapter 1 Product Overview
1-41
ports.
Fig 1-23 C704-M-X1S12C24(R4) front panel view
C700-X2S12C12(R4) provides two 10G XFP ports, twelve 1G optical SFP ports, twenty four 1G electronic SFP ports, where the twelve 1G optical ports and the last twelve 1G electronic ports are combo ports.
1.4.2.16.2 Front Panel Indicator
The description of front panel indicator of C704-M-X1S12C24(R4) and C700-X2S12C12(R4) is as follows:
Table 1-24 C704-M-X1S12C24(R4) and C700-X2S12C12(R4) indicator description
LED
Indicator
Panel
Sign
Status
Meanings
Power Indicator
PWR On (Green)
Network Interface Card power on
Off
Network Interface Card power off
Running Indicator
RUN On (Green 1Hz
flash)
Network Interface Card running in normal status
On (Green 8Hz flash)
System loading (Network Interface Card Booting after hot plug in)
Off
Running status is in failure
RJ-45 Interface indicator
Status Indicator
Shared
On (Green)
RJ-45 Interface Network Connection is normal
Off
There is not network connection at RJ-45 interface
Transmissio n Indicator
On (Yellow)
Sending or receiving data
SFP Interface Indicator
Status Indicator
“Left Light”
On (Green)
SFP transceiver network connection is normal
Off
There is not network connection at SFP interface
Transmissio n Indicator
“Right Light”
On (Green)
Sending or receiving data
XFP interface Indicator
Page 47
C700 InstallManual Chapter 1 Product Overview
1-42
Status Indicator
Link On (Green)
XFP transceiver network connection is normal
Off
There is not network connection at XFP transceiver
Transmissio n Indicator
Act
On (Green)
Sending or receiving data
1.4.2.16.3 Front Panel Interface Description
C704-M-X1S12C24(R4) and C700-X2S12C12(R4) provide twelve SFP 1G optical fibre transceivers and twenty four RJ-45 1G electronic port slots.
C700-X2S12C12(R4) provides two XFP 10G optical ports.
1.4.2.17 C700-S48(R4)
48-port 1000Mbps optical line cardC700-S48(R4): Implement 2-layer and 3-layer wire-speed switching and routing function of 48 1000Mbps optical interfaces, and IPv6 wire-speed transmission.
1.4.2.17.1 Front Panel Diagram
C700-S48(R4) provides 48 1000Mbps optical interfaces.
The following is the sketch map of its front panel:
Fig 1-24 the Sketch Map of the Front Panel of C700-S48(R4)
The ports in the above chart are port GB1GB48 from the bottom-left corner to the top-right corner. The indicator lamps of ports having odd index number are on the left side of the port array, while the indicator lamps of ports having even index number are on the right side. The lamps are green indicator lamps.
1.4.2.17.2 Front Panel Indicator
The following is the instruction of the indicator lamps on the front panel of C700-S48(R4).
Table 1-25 the Instruction of Indicator Lamps of C700-S48(R4)
LED
Indicator
Panel
Sign
State
Explanation
Page 48
C700 InstallManual Chapter 1 Product Overview
1-43
SFP Interface Indicator Lamps
State Indicator Lamp
On(green)
The network connection of SFP interface is normal.
Off
There is no network connection on SFP interface
Transmissio n Indicator Lamp
On(green)
SFP is receiving or sending data.
1.4.2.17.3 Front Panel Interface Description
C700-S48(R4) provides 48 SFP1000Mbps optical transceiver interfaces.
1.4.2.18 C704-M-X1S12C24(R4)
The C704-M-X1S12C24(R4) is switching module for the C704. System status control, switch management, user access control and management, and network maintenances are performed here. The board can be inserted into first or second slots of the chassis for Master-Slave redundancy. 12-port 1G optical-electronic combo, 12-port 1G electronic and 2-port 10G XFP interface, and IPv6 wire speed transmission function.
1.4.2.18.1 Front Panel Diagram
C704-MIXFP12GX12GT(R4) provides 2-port 1G optical-electronic combo, 12-port 1G electronic and 2-port 10G XFP interface.
Fig 1-25 C704-M-X1S12C24(R4) front panel view
1.4.2.18.2 Front Panel Indicator
The description of front panel indicator of C704-M-X1S12C24(R4) as follows:
Table 1-26 C704-M-X1S12C24 (R4) indicator description
LED
Indicator
Panel
Sign
Status
Meanings
Power Indicator
PWR On (Green)
Network Interface Card power on
Off
Network Interface Card power off
Master-Slav
e indicator
M/S
On(Green)
Master
Off
Slave
Page 49
C700 InstallManual Chapter 1 Product Overview
1-44
Fan Indicator
FAN On(Green)
Fan operating normally
On(Red)
Fan operating abnormally
Off
Fan not present
Running Indicator
RUN On (Green 1Hz
flash)
Network Interface Card running in normal status
On (Green)
System loading (Network Interface Card Booting after hot plug in)
Off
Running status is in failure
RJ-45 Interface indicator
Status Indicator
Shared
On (Green)
RJ-45 Interface Network Connection is normal
Off
There is not network connection at RJ-45 interface
Transmissio n Indicator
On (Yellow)
Sending or receiving data
SFP Interface Indicator
Status Indicator
“Left Light”
On (Green)
SFP transceiver network connection is normal
Off
There is not network connection at SFP interface
Transmissio n Indicator
“Right Light”
Flashes (Green)
Sending or receiving data
XFP interface Indicator
Status Indicator
Link On (Green)
XFP transceiver network connection is normal
Off
There is not network connection at XFP transceiver
Transmissio n Indicator
Act
Flashes (Green)
Sending or receiving data
1.4.2.18.3 Front Panel Interface Description
C704-M-X1S12C24(R4) provides 12-port 1G optical-electronic combo, 12-port 1G electronic and 2-port 10G XFP interface.
1.4.2.19 C708-M(R4)
The C708-M(R4) is switching module for the C708. System status control, switch management, user access control and management, and network maintenances are
Page 50
C700 InstallManual Chapter 1 Product Overview
1-45
performed here. The board can be inserted into M1 or M2 slots of the chassis for Master-Slave redundancy.
1.4.2.19.1 Front Panel
The C708-M(R4) comes with 1 Console port (control console), 1 10/100Base-Tx Ethernet port (management port) and 1 CF card port.
The Front Panel view is shown below:
Fig 1-26 C708-M(R4) Front Panel view
1.4.2.19.2 Front Panel - Indicator
The following table describes the front panel indicators of C708-M(R4):
Table 1-27 C708-M(R4) indicators description
LED
Panel Symbol
Status
Description
Power
Indicator
PWR
On (Green)
Card powered
Off
Card powered off
Operation
indicator
RUN
On (Green, blink at 1 Hz)
Cards operating normally
On (Green, blink at 8 Hz)
System is loading Off
Cards malfunction
Master-Slav
e indicator
M/S
On (Green)
Master
Off
Slave
Power
Supply
Module
Status
indicator:
POWER
POWER _OK
On (Green)
Power Supply Module operating normally
Off
Power supply module malfunctioning or not present
POWER_Fail
On (Yellow)
Power Supply Module alarm
Off
Power supply module not alarm or not present
Fan
Assembly
Status
indicator:
FAN
FAN_OK
On (Green)
Fan operating normally
Off
Fan malfunctioning or not present
FAN_ALARM
On (Yellow)
Fan alarm
Off
Fan operating not alarm or not
Page 51
C700 InstallManual Chapter 1 Product Overview
1-46
present
Ethernet manageme nt port indicator
ACT
On (Green)
Ethernet port Sending or receiving data
Off
Ethernet port Sending or receiving no data
LINK
On (Green)
Ethernet port link success
Off
Ethernet port link unsuccess
CF card
status
indicator
CF-STATUS
On (Green)
CF card is in position and can work
Off
CF card not present
1.4.2.19.3 Front Panel – Console Port
The C708-M(R4) provides a RJ-45 (receptacle) Console serial port. Users can connect to hosts via this port to perform system debugging, configuration, maintenance, management and host software loading.
Table 1-28 C708-M(R4) Console description
Property
Specification
Connector
RJ-45 (receptacle)
Connector type
RS-232
Baud rate
9600bps (default)
Supporting service
Connects to character terminals Connects to PC serial port and running terminal emulator
on PC.
1.4.2.19.4 Front Panel – Management Port
The C708-M(R4) provides a RJ-45 (receptacle) Ethernet port. Users can connect through this management port to hosts for program loading or to connect to remote devices for remote management (e.g., a managing workstation). Note: when connecting to the host, a cross-over cable should be used.
Table 1-29 C708-M (R4) management port description
Property
Specification
Connector
RJ-45 (Receptacle)
Connector type
10/100Mbps auto sensing Cat 5 UTP: 100 m
1.4.2.19.5 Front Panel – CF Card Interface
Page 52
C700 InstallManual Chapter 1 Product Overview
1-47
C708-M(R4) provides a standard CF card slot, and supports hot-swapping. CF card content supports 256MB/512MB/1GB, it can be save edition, configuration files and so on, so as to conveniency switch software update. Notice: It is suggested to ues FOXGATE CF card, it is not assure the compatibility with other CF card.
1.4.3 Interface description
C700 series provide 1000Mbps SFP electric interfaces, RJ-45 (receptacle) Console serial ports and 10,000Mbps XFP electric interfaces.
C700 series provide this types of SFP:
SFP-SX-L Gigabit SFP MM 850 nm, 500m (SX) SFP-LX-L Gigabit SFP SM 1310 nm, 10Km (LX) SFP-LX-20-L 20 Gigabit SFP SM 1310 nm, 20Km (LX) SFP-LX-40-L Gigabit SFP SM 1310 nm, 40Km (LHX) SFP-LH-70-L Gigabit SFP SM 1550 nm, 70Km (ZX) SFP-LH-120-L Gigabit SFP SM 1550 nm, 120Km (ZX) SFP-GT 1000Base-T SFP module SFP-GFX 100Base-FX SFP module SFP-GFL 100Base-FL SFP module
C700 series provide this types of XFP:
XFP-SR transceiver XFP-LR transceiver ,10Km XFP-ER transceiver ,40Km XFP-ER-70 transceiver ,70Km HFCT-721XPD FTRX-1411D3 PT745F-81-1TD
interface description as follow:
Table 1-30 C700 series interface description
Interface Format
Specs
RJ-45 port
10/100/1000Mbps self-adapting MDI/MDI-X network wire type self-adapting
5 kinds of Unshielded Twisted Pair(UTP): 100
metres
SFP
SFP-SX-L transceiver
62.5/125um multi-mode fiber275m
50.0/125um multi-mode fiber550m
Page 53
C700 InstallManual Chapter 1 Product Overview
1-48
SFP-LX-L transceiver
9/125um single-mode fiber10Km
SFP-LX-20-L transceiver
1310nm9/125um single-mode fiber20Km
SFP-LX-40 transceiver
9/125um single-mode fiber40Km
SFP-LH-70-L transceiver
9/125um single-mode fiber70Km
SFP-LH-120-L transceiver
9/125um single-mode fiber120Km
SFP-GFX transceiver
1310nm MMF, 1~2Km
SFP-GFL transceiver
1310nm SMF, 10Km
XFP
XFP-SR transceiver
850nmMMF 32m/85m/300m
XFP-LR transceiver
1310nm SMF, 10Km
XFP-ER transceiver
1550nm SMF, 40Km
XFP-ER-70 transceiver
1550nm SMF, 70Km
HFCT-721XPD
10GBASE-LR1310nm 9/125um single-mode fiber10Km
FTRX-1411D3
10GBASE-LR/LW1310nm 9/125um single-mode fiber10Km
PT745F-81-1TD
10GBASE-LR1310nm 9/125um single-mode fiber10Km
Page 54
C700 InstallManual Chapter 1 Product Overview
1-49
1.4.4 Power supply
1.4.4.1 C704-PWR-AC
C704 uses 1 +1 redundant power supplies. Each of them may serve as a standby power supply for another. Under normal operation conditions, the two power supply modules concurrently operate and each of them bears half of the loads. If one of the power supply modules fails to work or its switch is off, its alarming indicator will be on. At the same time, another power supply becomes responsible for the power supply of the whole switch. When the failure power supply module returns to normal state or its switch is turned on, the alarming indicator will be off. The power supply modules are installed on the upper part of the machine chassis, and are connected with the backplane of the switch through specific interfaces. The two power supply modules are fixed on the machine chassis with two screws. Each power supply module has one switch. Under normal operation conditions, two switches shall be turned on. For changing power supply modules, it is not necessary to open the chassis. You may turn off the switches of corresponding power supply modules and screwing off the fixing screws for changing the modules.
1.4.4.1.1 C704-AC (Alternating Current Power Module)
When powered by AC inputs, the AC power module C704-PWR-ACand corresponding AC distribution box should be used in the C704. The input voltage of theC704-PWR-ACis 200V/264 VAC, with ranges between 200 ~ 264 VAC and frequency between 50 ~ 60 Hz, the maximum output power is 400W.
1.4.4.1.2 Power module Front Panel
The front panel of C704-PWR-ACis equipped with power supply switches, power supply indicators as well as ventilating and cooling port and a handle for inserting and pulling out the modules.
The Front Panel view is shown below:
Page 55
C700 InstallManual Chapter 1 Product Overview
1-50
Fig 1-27C704-PWR-ACFront Panel View
1.4.4.1.3 LED
The LED description of C704-PWR-AC is as follows
Table 1-31 The Description of C704-PWR-AC LED
LED
Panel Label
Status
Description
Output LED
Output Good
On Green
Power Module Output Status is okay
Off
Power Module has no output
Abort LED
Fault
On Yellow
Faulty Power Module /Not turning-on The Output Switch
Off
Power Module Working Fine
1.4.4.1.4 Switch of power supply for front panel
C704-PWR-AC provides a power supply switch for controlling the power output of control module. Under normal operation conditions, the switches for power supply modules shall be turned on concurrently. When the switch of one power supply module is turned on and another is turned off, the FAULT indicator of the module will be on to suggest the users to turn on the switch so as to utilize 1+1 redundant backup.
1.4.4.2 C704-PWR-A1-AC
C704 (V2.0 above) uses 1 +1 redundant power supplies. Each of them may serve as a standby power supply for another. Under normal operation conditions, the two power supply modules concurrently operate and each of them bears half of the loads. If one of
Page 56
C700 InstallManual Chapter 1 Product Overview
1-51
the power supply modules fails to work or its switch is off, its alarming indicator will be on. At the same time, another power supply becomes responsible for the power supply of the whole switch. When the failure power supply module returns to normal state or its switch is turned on, the alarming indicator will be off.
The power supply modules are installed on the upper part of the machine chassis, and are connected with the backplane of the switch through specific interfaces. The two power supply modules are fixed on the machine chassis with two screws. Each power supply module has one switch. Under normal operation conditions, two switches shall be turned on. For changing power supply modules, it is not necessary to open the chassis. You may turn off the switches of corresponding power supply modules and screwing off the fixing screws for changing the modules.
1.4.4.2.1 C704-PWR-A1-AC (Alternating Current Power Module)
When powered by AC inputs, the AC power module C704-PWR-A1-AC and corresponding AC distribution box should be used in the C704(V2.0 above). The input voltage of the C704-PWR-A1-AC is 200V/264 VAC, with ranges between 200 ~ 264 VAC and frequency between 50 ~ 60 Hz, the maximum output power is 400W.
1.4.4.2.2 Power module Front Panel
The front panel of C704-PWR-A1-AC is equipped with power supply switches, power supply indicators as well as ventilating and cooling port and a handle for inserting and pulling out the modules.
The Front Panel view is shown below:
Fig 1-28 C704-PWR-A1-AC Front Panel View
Page 57
C700 InstallManual Chapter 1 Product Overview
1-52
1.4.4.2.3 LED
The LED description of C704-PWR-A1-AC is as follows
Table 1-32 The Description of C704-PWR-A1-AC LED
LED
Panel Label
Status
Description
Output LED
Output Good
On Green
Power Module Output Status is okay
Off
Power Module has no output
Abort LED
Fault
On Yellow
Faulty Power Module /Not turning-on The Output Switch
Off
Power Module Working Fine
1.4.4.2.4 Switch of power supply for front panel
C704-PWR-A1-AC provides a power supply switch for controlling the power output of control module. Under normal operation conditions, the switches for power supply modules shall be turned on concurrently. When the switch of one power supply module is turned on and another is turned off, the FAULT indicator of the module will be on to suggest the users to turn on the switch so as to utilize 1+1 redundant backup.
1.4.4.3 C704-PWR-A1-DC
C704 uses 1 +1 redundant DC power supplies. But not suggest that the AC power and DC power be used mixed.
1.4.4.3.1 C704-PWR-A1-DC (Direct Current Power Module for 400W)
C704-PWR-A1-DC is a Direct Current Power module for 400W, which support hot plug and redundance backup.
C704-PWR-A1-DC can be used in the C704(V2.0 above).
1.4.4.3.2 Power module Front Panel
The front panel of C704-PWR-A1-DC is equipped with power supply switches, power supply indicators as well as ventilating and cooling port and a handle for inserting and pulling out the modules. On panels right hand is DC connector, supports -48VDC input. The power supply DC connector has three input terminal, they are RTN, -48V and PG from the top down, the meanings are shown below:
RTN power supply reflow
-48V -48V input
Page 58
C700 InstallManual Chapter 1 Product Overview
1-53
PG plane ground
The Front Panel view is shown below:
Fig 1-29 C704-PWR-A1-DC Front Panel View
1.4.4.3.3 LED
The LED description of C704-PWR-A1-DC is as follows:
Table 1-33 The Description of C704-PWR-A1-DC LED
LED
Panel Label
Status
Description
Output LED
Output Good
On Green
Power Module Output Status is okay
Off
Power Module has no output
Abort LED
Fault
On Yellow
Faulty Power Module /Not turning-on The Output Switch
Off
Power Module Working Fine
1.4.4.3.4 Switch of power supply for front panel
C704-PWR-A1-DC provides a power supply switch for controlling the power output of control module. Under normal operation conditions, the switches for power supply modules shall be turned on simultaneous. When the switch of one power supply module is turned on and another is turned off, the FAULT indicator of the module will be on to suggest the users to turn on the switch so as to utilize 1+1 redundant backup.
Page 59
C700 InstallManual Chapter 1 Product Overview
1-54
1.4.4.4 C704-PWR-B1-AC
C708 uses 2 +1 redundant power supplies, three power modules can act as backups for each other. During normal operation, all three power modules each take one third of the load. If one of the modules fails or is not present, the other two power modules will supply power for the whole switch, and the corresponding POWER/Fail warning indicator for the failed/missing module will illuminate, prompting the replacement of the failed module. The warning indicator will turn off after the failed module is replaced or recovers. The C708 power module is installed in the lower section of the chassis, and connects to the power board of the switch. All the power modules attach to the chassis with 2 screws, respectively. When replacing the power modules, the chassis need not to be opened, just remove the 2 fastening screws to take out the power module requiring replacement.
1.4.4.4.1 C704-PWR-B1-AC (Alternating Current Power Module)
When powered by AC inputs, the AC power module C704-PWR-B1-AC and corresponding AC distribution box should be used in the C708. The input voltage of the C704-PWR-B1-AC is 110V/220 VAC, with ranges between 90 ~ 264 VAC and frequency between 50 ~ 60 Hz, the maximum output power is 600W.
1.4.4.4.2 1.4.3.2.2 Power module Front Panel
There are vents (with dust gauzes), 2 fastening screws and handle for replacing the modules on the front panels of C704-PWR-B1-AC and C704-PWR-B1-AC.
The Front Panel view is shown below:
Page 60
C700 InstallManual Chapter 1 Product Overview
1-55
Fig 1-30 C704-PWR-B1-AC Front Panel view
Fig 1-31 C704-PWR-B1-AC Front Panel view
1.4.5 Power Distribution Box
1.4.5.1 C704 Power Distribution Box
There is a special A.C. distribution box on the backboard of C704 switch. In generally, the enterprises users usually ask for the 200~264VAC access. The panel of A.C. distribution box is equipped with a 200~264VAC socket for provide power supply to the equipment. At the same time, it provides power supply to the two power supply modules. After the D.C. output is disposed on the backplane, it provides power supply to the modules and fan tray. The lower part of the power supply socket is equipped with a locking ring, which is used to fix the power supply lines to prevent unexpected disconnection and make the wiring more convenient. The distribution box is equipped with a grounding terminal at its lower right part, which is used for grounding the switch.
The Front Panel view is shown below:
Page 61
C700 InstallManual Chapter 1 Product Overview
1-56
Fig 1-32 C704 Power Distribution Box Panel view
1.4.5.2 C704(V2.0 above) Power Distribution Box
There is a special A.C. distribution box on the backboard of C704(v2.0 above) switch.
In generally, the enterprises users usually ask for the 200~264VAC access. The panel of A.C. distribution box is equipped with a 200~264VAC socket for provide power supply to the equipment. At the same time, it provides power supply to the two power supply modules. After the D.C. output is disposed on the backplane, it provides power supply to the modules and fan tray. The lower part of the power supply socket is equipped with a locking ring, which is used to fix the power supply lines to prevent unexpected disconnection and make the wiring more convenient. The distribution box is equipped with a grounding terminal at its lower right part, which is used for grounding the switch.
The Front Panel view is shown below:
Fig 1-33 C704(v2.0 above) Power Distribution Box Panel view
1.4.5.3 C708 Power Distribution Box
There is a dedicated AC distribution box or DC distribution box in the lower section of C708 backplane, distributing power supply for the corresponding AC or DC power module. A grounding post is provided on the chassis on both sides of the distribution box for switch grounding. There is also an extraction handle, which is intended for the installation and
Page 62
C700 InstallManual Chapter 1 Product Overview
1-57
removal of the distribution box only. Never lift or move the switch with this handle!
1.4.5.3.1 AC Power Distribution Box
Enterprise network users usually require equipment to have 220 VAC input, the AC power modules and AC distribution box can satisfy this application. Three 220V/110 VAC power input sockets are provided on the panel of the C708 AC distribution box. Input AC power will first pass through protective circuits, such as the AC filter, lightning protection tube, and then provide power for the three AC power modules. The other modules and fan trays are powered only after the DC output from the power modules are equalized and coupled. A wiring clip is provided above each 220V/110 VAC input socket for the positioning of power cords and easier wiring. In addition, on the left side of the AC
distribution panel is a power supply switch used to control the modules‟ power output .
Please turn this power supply switch on during normal operation of the C708.
The Front Panel view is shown below:
Fig 1-34 C708 AC Power Distribution Box
1.4.5.3.2 DC Power Distribution Box
Telecom network users usually require equipment to have -48V DC input, the DC power modules and DC distribution box can satisfy this application. Two sets of -48V DC power input posts are provided on the panel of C708 DC distribution box. Each DC input will first pass through protective circuits, such as the DC feed through filter, current limiting protection air switch, coupling diode, and then provide power for all three DC power modules. The other modules and fan trays are powered only after the DC output from the power modules are equalized and coupled. Please turn on the air switch of -48V DC input during normal operation of C708.
The Front Panel view is shown below:
Page 63
C700 InstallManual Chapter 1 Product Overview
1-58
FIG 1-35 C708 DC Power Distribution Box
1.4.6 System Backplane
The system board of C704 serial switch is located inside the switch, providing interconnectivity in the high speed data links between management switching modules, network interface modules and between all management and control signals of various cards. A backplane has been installed in the unit chassis. The backplane provides the following functions:
Provides communication channel for cards to achieve interconnectivity of
various signals
The backplane is powerless Supports the hot-swapping of various cards Supports Mainboard Master-Slave swap Auto identification of all slots Distributed power supplies
Introduction of monitoring signals for fans and power supplies
1.4.7 Fan Tray
1.4.7.1 C704 Fan Tray
Three fan assemblies (C704-FAN) can be configured in the C704, and installed in a
horizontal configuration into the fan module slots in the switch‟s upper front panel. The
three fan assemblies cover the entire board area, ensuring sufficient ventilation for the devices, hence enhancing the stability of devices even under high temperature environments. Each fan assembly consists of 2 axial fans, which are protected by the fan tray to prevent bodily injury. Please note that the fan blades still spin at a high speed when disconnected from the device during operation, to avoid bodily injury do not touch the
Page 64
C700 InstallManual Chapter 1 Product Overview
1-59
spinning blades.
Fig 1-36 C704-FAN Outlook
Fig 1-37 C704-FAN Front Panel View
1.4.7.2 C708 Fan Tray
Three fan assemblies (MRS-7608-FAN) can be configured in the C708, and installed
in a horizontal configuration into the fan module slots in the switch‟s upper front panel. The
three fan assemblies cover the entire board area, ensuring sufficient ventilation for the devices, hence enhancing the stability of devices even under high temperature environments. Each fan assembly consists of 2 axial fans, which are protected by the fan tray to prevent bodily injury. Please note that the fan blades still spin at a high speed when disconnected from the device during operation, to avoid bodily injury do not touch the spinning blades.
Page 65
C700 InstallManual Chapter 1 Product Overview
1-60
Fig 1-38 C708-FAN Outlook
Fig 1-39 C708-FAN Front Panel View
1.4.8 Dust Gauze
1.4.8.1 C704 Dust Gauze
The C704‟s dust gauze lies under the board rack and prevents large particles in the air from entering the switch. The dust gauze should be inserted from the front of the C704 in a horizontal position.
Page 66
C700 InstallManual Chapter 1 Product Overview
1-61
Fig 1-40 C704 Dust Gauze Outlook
1.4.8.2 C708 Dust Gauze
The C708‟s dust gauze lies under the board rack and prevents large particles in the air from entering the switch. The dust gauze should be inserted from the front of the C708 in a horizontal position.
Fig 1-41 C708 Dust Gauze Outlook
1.4.9 Rear Panel
Page 67
C700 InstallManual Chapter 1 Product Overview
1-62
1.4.9.1 C704 Rear Panel
The rear panel of the C704 covers the switch backplane. To ensure safe operation of the switch, please do not open the rear panel. There are two reversible handles on the rear panel, they are used only for the installation and removal of the rear panel. Never lift or move the switch with these handles! The rear panel is shown below:
FIG 1-42 C704 Rear Panel View
1.4.9.2 C704 Rear Panel
The rear panel of the C708 covers the switch backplane. To ensure safe operation of the switch, please do not open the rear panel. There are two reversible handles on the rear panel, they are used only for the installation and removal of the rear panel. Never lift or move the switch with these handles! The rear panel is shown below:
Page 68
C700 InstallManual Chapter 1 Product Overview
1-63
FIG 1-43 C708 Rear Panel View
1.4.10 Side Panels
1.4.10.1 C704 Side Panels
There are several rows of ventilation openings in the left and right sides of the switch,
Page 69
C700 InstallManual Chapter 1 Product Overview
1-64
as shown above.
FIG 1-44 C704 Side Panels View
Please do not block the ventilation openings and ensure that enough clearance is left on both sides of the switch for air circulation. Failure to do so can cause the chassis to overheat and the system to fail, or damage to components.
1.4.10.2 C708 Side Panels
There are several rows of ventilation openings in the left and right sides of the switch, as shown above.
Page 70
C700 InstallManual Chapter 1 Product Overview
1-65
FIG 1-45 C708 Side Panels View
Please do not block the ventilation openings and ensure that enough clearance is left on both sides of the switch for air circulation. Failure to do so can cause the chassis to overheat and the system to fail, or damage to components.
1.5 System Features
1.5.1 C704 System Features
Page 71
C700 InstallManual Chapter 1 Product Overview
1-66
Table 1-34 C704 System Features
SDRAM
128MB
FLASH
32MB
Status indicator:
Port: Traffic, LINK General: Power status, system status, hot-swap
indicator
Weight
30KG (Max full configuration weight)
Physical Dimensions
445mm x266mm x421mm (W x H x D) 440(宽)X 266(高)X 421(深) C704V2.0above
Relative humidity
10% ~ 90% with no condensing
Operating
Temperature
0C ~ 40C
Power Supplies
Nominal Input Voltage AC: 200 ~ 264 VAC, 50 ~ 60Hz
(supporting 1+1 redundant backup of power
modules)
Power Consumption
400 W
Forwarding Mode
Store-and-forward
The C704 Switch system features are described in the table below.
Table 1-35 C704 System Features
Property
Specification
Basic Configuration
4 slots
Hot swap
Yes
Failover design
Core part redundant hot swapping
Power supplies redundant hot swappable
1.5.2 C708 System Features
Table 1-36 C708 System Features
SDRAM
128MB
FLASH
32MB
Status indicator:
Port: Traffic, LINK General: Power status, system status, hot-swap
Page 72
C700 InstallManual Chapter 1 Product Overview
1-67
indicator
Weight
65KG (Max full configuration weight)
Physical Dimensions
436mm x 797mm x 478mm (W x H x D)
Relative humidity
10% ~ 90% with no condensing
Operating
Temperature
0C ~ 40C
Power Supplies
Nominal Input Voltage AC: 90 ~ 264 VAC, 50 ~ 60Hz DC: -36 ~ -72 VDC
(supporting 2+1 redundant backup of power modules)
Power Consumption
1200 W
Forwarding Mode
Store-and-forward
The C708 Switch system features are described in the table below.
Table 1-37 C708 System Features
Property
Specification
Basic Configuration
10 slots
Hot swap
Yes
Failover design
Core part redundant hot swapping
Power supplies redundant hot swappable
Page 73
C700 InstallManual Chapter 2 Hardware Installation
2-1
Chapter 2 Hardware Installation
During the installation and use of the C700 Switch, please follow the safety guidelines listed below:
2.1 Basic Requirements
2.1.1 Site Requirements
The C700 series Switch must be used indoors, and have the following requirements:
Ambient temperature: 0 ~ 40°C
Humidity: 10% ~ 90%, non-condensing
The C700 series is equipped with a fan assembly for providing the switch with an appropriate level of cooling; you can place the switch on a workbench or rack. Ensure the following:
The rack or workbench should be well ventilated. For sufficient air circulation, it
is recommended to mount the switch on a 19″ standard rack with sufficient
spacing. Air conditioning is recommended in areas with high temperatures in the summer.
To cool the internal circuits, the switch comes with internal fan assemblies. To
maintain proper air circulation through the switch chassis, we recommend that you maintain a minimum 100mm separation between the chassis air intake or the chassis air exhaust and any walls. Make sure that all air intakes and exhausts on the system remain unobstructed. Do not stack heavy items on the switch.
Make sure the rack or workbench is strong enough to support the weight of a
fully configured switch.
Make sure the rack or workbench is well grounded; if the workbench is not
grounded, it should be placed near a grounding conductor to provide easy ground connection for the switch.
2.1.2 Temperature and Humidity Requirements
To maximize the switch‟s performance and lifespan, the site should maintain a
desirable temperature and humidity. High-humidity conditions can cause electrical resistance degradation or even electric leakage, degradation of mechanical properties
Page 74
C700 InstallManual Chapter 2 Hardware Installation
2-2
and corrosion of internal components. Extreme low relative humidity may cause the insulation spacer to contract, making the fastening screw insecure. Furthermore, in dry environments, static electricity is liable to be produced and cause harm to internal circuits. Temperature extremes can cause reduced reliability and premature aging of insulation
materials, thus reducing the switch‟s working lifespan. The recommended temperature
and humidity are shown below:
Temperature:
Relative humidity
Long term condition
Short term condition
Long term condition
Short term condition
15 ~ 30°C
0 ~ 40°C
40~65%
10~90%
A sample of ambient temperature and humidity should be taken at 1.5m above the floor and 0.4m in front of the switch rack, with no protective panel covering the front and rear of the rack.
Short term working conditions refer to a maximum of 48 hours of continued operation and an annual cumulative total of less than 15 days.
Formidable operation conditions refers to the ambient temperature and relative humidity value that may occur during an air-conditioning system failure, and normal operation conditions should be recovered within 5 hours.
2.1.3 Dust and Particles
Dust is harmful to the safe operation of the C700 series. Dust can lead to electrostatic adherence, especially likely under low relative humidity, causing poor contact of metal connectors or contacts. Electrostatic adherence will result in not only reduced product lifespan, but also increased chance of communication failures. The recommended values for dust content and particle diameter in the site are shown below:
Max. Diameter (µm)
0.5 1 3
5
Max. Density
(particles/m³)
1.4×10
7
7×10
5
2.4×10
5
1.3×10
5
In addition, salt, acid and sulfide in the air are also harmful to the switch. Such harmful gases will aggravate metal corrosion and the aging of some parts. The chosen
Notice
Page 75
C700 InstallManual Chapter 2 Hardware Installation
2-3
site should avoid harmful gases, such as SO2, H2S, NO2, NH3 and Cl2, etc. The table below details the threshold values.
Gas
Average (mg/m³)
Max (mg/m³)
SO2
0.2
1.5
H2S
0.006
0.03
NO2
0.04
0.15
NH3
0.05
0.15
Cl2
0.01
0.3
2.1.4 Preventing Electrostatic Discharge Damage
Static electric discharges can cause damage to internal circuits, even the entire switch. Follow these guidelines for preventing ESD damage:
1. Ensure proper earth grounding of the device
2. Perform regular cleaning to reduce dust
3. Maintain proper temperature and humidity
4. Always wear an ESD wrist strap and antistatic uniform when in contact with circuit
boards
2.1.5 Anti-interference Requirements
All sources of interference, whether from the device/system itself or the outside environment, will affect operations in various ways, such as capacitive coupling, inductive coupling, electromagnetic radiation, common impedance (including the grounding system) and cables/lines (power cables, signal lines, and output lines). The following should be noted:
1. Precautions should be taken to prevent power source interruptions
2. Provide the system with a dedicated grounding, rather than sharing the grounding
with electronic equipment or lightning protection devices
3. Keep away from high power radio transmitters, radar transmitters, and high frequency
strong circuit devices
4. Provide electromagnetic shielding if necessary
2.1.6 Rack Configuration
The dimensions of the C700 are designed to be mounted on a standard 19‟‟ rack,
Page 76
C700 InstallManual Chapter 2 Hardware Installation
2-4
C704s dimensions are 445mm x 266mm x 421mm (W x H x D), C704(V2.0 above)s dimensions are 440mm x 266mm x 421mm (W x H x D). C708‟s dimensions are 436mm x 797mm x 478mm (W x H x D). Please ensure good ventilation for the rack. Every device in the rack will generate heat during operation, therefore vent and fans
must be provided for an enclosed rack, and devices should not be stacked closely,. When mounting devices in an open rack, care should be taken to prevent the rack
frame from obstructing the switch ventilation openings. Be sure to check the
positioning of the switch after installation to avoid the aforementioned.
If a standard 19‟‟ rack is not available, the C700 series can be placed on a clean level desktop, leave a clearance of 100mm around the switch for ventilation, and do not place anything on top of the switch.
2.1.7 Power Supply Requirements
The C700 is designed to use modular switching power supplies. The power input specification is shown below:
Nominal Input Voltage: AC: 200 ~ 264 VAC, 50 ~ 60Hz DC: -36 ~ -72VDC DCR-7604 total power consumption: ≤400W DCR-7608 total power consumption: ≤1200W
Before installing the power modules, please check the power input to ensure proper grounding of the power supply system. The input source for the switch should be reliable and security, a voltage adaptor can be used if necessary. The building‟s circuit protection system should include in a fuse or circuit-breaker of no greater than 240V, 10A. It is recommended to use a UPS for more reliable power supply.
Improper power supply system grounding, extreme fluctuation of the input source, and transients (or spikes) can result in larger error rate, or even hardware damage.
Notice
Notice
Page 77
C700 InstallManual Chapter 2 Hardware Installation
2-5
2.2 Safety Guidelines
1 Disconnect power supplies from the chassis before disassembly or moving the
switch.
2 Install the switch in a clean area, ensuring proper temperature and humidity
conditions. 3 Keep the device accessories in a safe place. 4 When handling modules, always handle the modules by the edge, avoid contact
with integrated components and printed circuits. Prevent electrostatic discharge
damage to the integrated components and printed circuits. 5 Keep maintenance tools in a safe place. 6 Do not wear loose clothing that may catch on devices, also remember to fasten
ties or scarves and roll up your sleeves. 7 If the environment may cause harm to eyes, be sure to wear a pair of protective
goggles. 8 Do not perform any operation that may result in bodily injury or damage to the
device. 9 When cleaning the switch, do not use a damp cloth to wipe the switch and never
wash the switch with liquids.
2.3 Safety Warning
1. Safety warnings appear throughout this publication, referring to operations that
may harm you if performed incorrectly.
2. Read through the installation instruction carefully before operating the system.
3. Only trained and qualified personnel should be allowed to install, replace, or
service the switch.
4. Disconnect power supplies from the chassis before disassembly or moving the
switch.
5. The final configuration of the product must abide by all national laws and codes.
6. The final configuration of the product must abide by in point national laws and
codes.
2.4 Hot Line Work Safety Guidelines
1. Before working on equipment that is connected to power lines, remove jewelry
(including rings, necklaces, watches and bracelets). Metal objects will cause short
Page 78
C700 InstallManual Chapter 2 Hardware Installation
2-6
circuits and damage the device when in contact with both powered items and the
ground.
2. An improper connection between the device and power sockets may be
hazardous.
3. Only trained and qualified personnel should be allowed to operate and maintain
the device.
4. Reading through the installation guidelines before powering on the system.
! Watch out for potential dangers, e.g. wet floors, ungrounded power lines, and worn
power lines;
! Have an emergency switch installed inside the workshop, so that power can be cut off
promptly should an accident occur;
! Do not work alone if potential dangers are present; ! On the event of an accident, take the following measures.
Measure1: Power down the system; Measure2: Make emergency calls if required; Measure3: Determine whether the victim requires immediate treatment and take appropriate action; Measure4: If possible, send someone for medical help; otherwise, consider the damage and seek help.
2.5 Preparing for Installation
After verifying site requirements, please check the contents of the switch container and accessory kit. (If you are concerned that any item is missing or an incorrect item has been supplied, please contact your dealer as soon as possible.)
2.5.1 Checking Switch Hardware Configuration and Accessories
After verifying site requirements, you can now unpack the shipping container to verify the switch configuration and contents of the accessory kit.
A basic configuration C704 should include the following:
Notice:
Page 79
C700 InstallManual Chapter 2 Hardware Installation
2-7
ITEM No.
Part name
Number
Memo
1
C704 Ethernet Switch
1 2
AC cable
3 3
Serial port cable
1 4
Grounding cord
1 5
Chassis hanger
2 6
Hanger screw
8 7
Rack screw
8 8
Manual CD
1 9
Qualification certificate
1 10
Warranty card
1
A basic configuration C708 should include the following:
ITEM No.
Part name
Number
Memo
1
C708 Ethernet Switch
1
2
AC cable
3 3
Serial port cable
1
4
Grounding cord
1
5
Chassis hanger
2 6
Hanger screw
12
8
Manual CD
1
9
Qualification certificate
1 10
Warranty card
1
Note: The above list is subject to change without notice, please use the packing list shipped with the switch as the checklist.
2.5.2 Required Tools and Utilities
Required tools
cross screwdrivers
Flat-blade screwdriver
ESD-preventive wrist strap
Connection cables
Serial port cable
Multi-mode fiber cable
Single-mode fiber cable
Page 80
C700 InstallManual Chapter 2 Hardware Installation
2-8
Category 5 cable with RJ-45 connector
2.6 Hardware Installation
The installation of the C700 includes the following: Switch mounting
Desktop installation
Rack-mounting the switch
Switch grounding Cards and modules installation Connecting to the Console
Connecting to the Console port
Connecting to the Management Port
Connecting to the Ethernet port
SFP transceiver installation
Install the SFP transceiver in the SFP slot
XENPAK transceiver installation
Install the XENPAK transceiver in the XENPAK slot
Copper Cable/Fiber cable connection
Ethernet cable connection
Fiber cable connection
Power supply connection
2.6.1 Switch Installation
2.6.1.1 Desktop installation
Note:
Choose a smooth level workbench
Verify that the workbench is strong enough to support the C704‟s fully configured
weight
Plan a good position for your C704 that is easy to operate and has an appropriate power source and grounding point.
Place the C704 safely on the workbench, avoid obstructions on any side of the switch.
Page 81
C700 InstallManual Chapter 2 Hardware Installation
2-9
To avoid damage, do not place any weight on the switch.
2.6.1.2 Rack-mounting C700 series.
Note:
Before mounting the C700 series into the rack, verify that the mounting positions of the rack are correct. Preposition of the mounting points may result in inadequate spacing between the switch front panel and the rack front door, and the rack front door may be unable to be closed with cables and fiber cables connected. Please keep a 10 mm spacing between the switch front panel and the rack front door.
Verify the following before installation: the rack is stably positioned; all modules inside the chassis are fully installed; no obstructions are present inside or around the rack; the switch is situated near the rack for ease of installation.
Installation Steps
Step 1: Attach the 2 hangers on the C700 series with screws provided in the
accessory kit. Be sure to attach the hangers in the correct direction, otherwise the switch will not be able to mount into a standard rack. Note that the hangers are not weight bearing. They are used to fasten the switch. The mounting Shelf or sliding rails (bolt to the rack) will support the switch. The figure below shows the steps for mounting the hangers:
Fig 2-1 Installing C704 Switch Hangers
Notice
Page 82
C700 InstallManual Chapter 2 Hardware Installation
2-10
Step 2: Put the hanger-mounted switch smoothly into a standard 19‟‟ rack.
Because of the size and weight of a C700 series, 2 people are required to complete the installation. With a person standing on each side of the chassis, grasp the chassis handle in the lower side panel with one hand, and use the other hand near the top of the chassis for balance. Slowly lift the chassis in unison and carry it to the rack. Lift the C700 series to a position a little higher than the mounting shelf or sliding rails, resting the chassis on the shelf/rails, and then carefully slide the chassis into the rack. Be sure to align the hangers and mounting holes in the rack column.
Step 3: Fasten the C700 series to the rack with the screws provided.
Bolt the hangers to the matching holes in the rack column with the screws provided. Be sure to tighten the screws smoothly. The C700 series should now be securely attached to the equipment rack. The procedure is shown below:
Fig2-3 Rack-mounting C704
Page 83
C700 InstallManual Chapter 2 Hardware Installation
2-11
Fig2-4 Rack-mounting C708
2.6.1.3 Wearing an ESD Wrist Strap
An ESD Wrist Strap must be worn during the installation of the switch. To prevent any
damage occurring to the device, avoid contact between the printed circuit boards and your clothing. Avoid bodily contact with components on the circuit boards if possible.
To wear an ESD Wrist Strap:
Step 1: place your hand into the ESD wrist strap. Step 2: tighten the fastener and ensure that it makes maximum contact with the skin. Step 3: Insert the equipment end of the strap into the antistatic socket (indicated by an ESD symbol) in the switch front panel.
2.6.2 Switch grounding
Page 84
C700 InstallManual Chapter 2 Hardware Installation
2-12
A good grounding system is the groundwork for the smooth and safe operation of the
C700 series, and an excellent way to prevent lightning strikes and resistance interference.
Please follow the switch grounding specification instructions, verify the installation site‟s
grounding condition and ensure proper grounding accordingly.
Proper grounding
When using an AC power source, the device must be grounded with the green and yellow ground cables, otherwise, shock hazards may occur when insulation resistance between the internal power supply and the chassis degrades. Lightning protection grounding
The lightning protection system is an independent system consisting of a lightning rod, conductor and connection joint with the grounding system. The grounding system usually is shared with the power reference grounding and green and yellow ground cable grounding. Lightning protection grounding is a building requirement, not a specific requirement of the switch. Electromagnetic compliance grounding
This refers to the grounding to comply with switch electromagnetic compatibility requirements, including shielded grounding, filter grounds, noise, and interference control and level reference. The overall grounding requirements are the sum total of the above. Ground resistance value should be less than 1 ohm.
The C700 series provides chassis grounding post in the lower rear chassis,
marked as “GND”. Chassis protection grounding should be properly connected to the
rack grounding connector
The ground cabling procedures are listed below: Step 1: remove the nuts from the rear chassis grounding posts Step 2: wrap one end of the green and yellow grounding cable to the grounding posts Step 3: attach the grounding post nut and tighten well Step 4: attach the other end of the grounding cable to the rack grounding connector
Note:
The grounding cable should be made of a good conductor, and the diameter
should be determined by the possible maximum current that may pass through.
Bare conductor cabling is forbidden. Ground resistance value: the combined grounding resistance should be less than
1 ohm.
2.6.3 Card and module installation
The C700 series is a rack-mounting device, various cards and modules are available.
Page 85
C700 InstallManual Chapter 2 Hardware Installation
2-13
Basic configuration: chassis, power supply modules (optional 1 +1 redundant), system backplane, fan tray, dust gauze, distribution box. The above parts have been mounted upon shipment, please verify they are properly locked before installation.
2.6.3.1 Removing and Installing the Cards
The installation procedure is the same for all cards, as shown below:
Step 1: Power down the switch (Hot-swapping is supported by optional cards for the
switch. However, for better convenience, it is recommended to power down the
switch before installing the cards, if no module in the switch is running.)
Step 2: Ensure proper grounding of the switch Step 3: Put on an ESD wrist strap before contact with the switch circuit, and make sure
the ESD wrist strap is connected securely to the ESD connector in the switch‟s
front panel.
Step 4: Loosen the panel fasteners locking back plate counterclockwise and remove the
back plate.
Step 5: Insert the optional module into the slot, you can use the metal handle on the front
plate of the module to ensure good contact. Then lock the module with panel
fasteners in the front plate.
2.6.3.2 Removing and installing the Dust Gauze
Dust gauze is provided in the right section of the C700 series, which can be installed
and removed from the back of the switch. The dust gauze is meant to prevent large debris or particles in the air from being ingested into the switch. Please perform cleaning on a regular basis according to the site conditions.
Loosen the 2 panel fasteners in the dust gauze Draw the dust gauze out smoothly by holding the 2 screws Clean the dust gauze with a brush (never wash with any liquid) Insert the gauze back to its original position in the switch Tighten the panel fasteners.
Note: The dust gauze is installed on switch chassis shipment.
The installation and removal of the dust gauze is shown below:
Page 86
C700 InstallManual Chapter 2 Hardware Installation
2-14
Fig2-5 Installation and removal of the C704 dust gauze
Fig2-6 Installation and removal of the C708 dust gauze
2.6.3.3 Removing and Installing the Fan Tray
2.6.3.3.1 Removing and Installing the C704 Fan Tray
Page 87
C700 InstallManual Chapter 2 Hardware Installation
2-15
The C704 has two fan trays in the left section of the switch, and can be serviced from
the front. The installation and removal of the fan tray is relatively simple. To install, just hold the fan tray in the correct direction, align with the corresponding slot and push to secure. Tighten the panel fasteners in the font panel. Upon removal, first loosen the 2 screws in the front panel of the fan tray, hold the handle in the front panel of fan tray with your middle and ring fingers, press the locker slightly down, and the fan tray can be drawn out smoothly.
Note: The fan trays are installed on switch chassis shipment. The installation and removal of a fan tray is shown below:
Fig2-7 The installation and removal of C704 fan tray
2.6.3.3.2 Removing and Installing the C708 Fan Tray
The C708 has three fan trays in the upper section of the switch, and can be serviced
from the front. The installation and removal of the fan tray is relatively simple. To install, just hold the fan tray in the correct direction, align with the corresponding slot and push to secure. The locker in the front panel of the fan tray will lock automatically. Upon removal, hold the handle in the front panel of fan tray with your middle and ring fingers, press the locker slightly down, and the fan tray can be drawn out smoothly.
Note: The fan trays are installed on switch chassis shipment. The installation and removal of a fan tray is shown below:
Page 88
C700 InstallManual Chapter 2 Hardware Installation
2-16
Fig2-8 The installation and removal of C708 fan tray
2.6.3.4 Removing and Installing Power Supply Modules
2.6.3.4.1 Removing and Installing C704 Power Supply Modules
The C704 employs a 1 +1 redundant power supply module combination, all two
modules will work during normal operation. In case one module fails, it can be replaced while the system is operating without presenting an electrical hazard or damage to the system. The procedures are provided below:
Step 1: First, turn off the switch in the front panel of the power supply module to be
replaced
Step 2: Loosen the 2 panel fasteners in the front panel of the power supply module
to be replaced by turning the screwdriver counter clockwise
Step 3: Hold the handle in the upper front panel of the power supply module, and
draw out the power supply module firmly and smoothly
Step 4: Turn off the switch in the front panel of the new power supply module, use
the new power supply module and replace the failed module. Tighten the
Page 89
C700 InstallManual Chapter 2 Hardware Installation
2-17
panel fasteners in the font panel
Step 5: Turn on the switch in the front panel of the power supply module, successful
replacement will be indicated by the green OUTPUT GOOD indicator on the front panel of the power supply module being illuminated and by the yellow Fail indicator not illuminating.
Installation of a power supply module is shown below:
Fig 2-9 The installation and removal of C704 power supply modules
2.6.3.4.2 Removing and Installing C708 Power Supply Modules
The C708 employs a 2 +1 redundant power supply module combinations, all three
modules will work during normal operation. In case one module fails, it can be replaced while the system is operating without presenting an electrical hazard or damage to the system. The procedures are provided below:
Step 1: Loosen the 2 panel fasteners in the front panel of the power supply module
to be replaced by turning the screwdriver counter clockwise
Step 2: hold the handle in the upper front panel of the power supply module, and
draw out the power supply module firmly and smoothly Step 3: Use a new power supply module and replace the failed module Step 4: Tighten the panel fasteners in the font panel Step 5: Successful replacement will be indicated by the green Power OK indicator
being illuminated and by the yellow Fail indicator not illuminating.
Installation of a power supply module is shown below:
Page 90
C700 InstallManual Chapter 2 Hardware Installation
2-18
Clean power module dust gauze
Power module dust gauze is provided in the front panel of the C704-PWR-B1-AC and
MRS- PWR-B1-DC power modules, which can be removed and installed easily. It can prevent large debris or particles in the air from being ingested into the power supply module. Please perform cleaning on a regular basis according to the site conditions.
Pulling the lower dust gauze front panel, draw the dust gauze and front panel
out
Clean the dust gauze with a brush (never wash with any liquid) Insert the gauze back to its original position in the power supply module Push dust gauze and front panel back to power module Press the lower dust gauze front panel and lock it
The installation and removal of the dust gauze is shown below:
FIG 2-11 The installation and removal of Power module dust gauze
2.6.4 Connecting to the Console
The C700 provides a RS-232 port as the local console. Users can configure the
switch through a character terminal (usually a PC) with RS-232 ports. The connection procedures are listed below: Step 1: Find a character terminal or a PC with a RS-232 serial port. Step 2: Connect the RS-232 serial port of character terminal to the configuration port of
the switch, ensuring at least one of them is powered down.
Notice
Page 91
C700 InstallManual Chapter 2 Hardware Installation
2-19
Upon connection, please verify the sign above the port to avoid using the wrong port.
2.6.5 Connecting to the Management Port
The C704-M12GB, C704-M4GX24TX(V2.1) and C708-MI provides a RJ-45 (female)
Ethernet port. Users can connect to this administration port through a backend host with Ethernet interface for program loading, or use this port to connect to remote devices (e.g., an administrative workstation) for remote administration. The connection procedure is listed below: Connecting to a back-end PC
Step 1: Find a PC with Ethernet Interface. Step 2: Connect the PC to the RJ-45 Ethernet port of the switch with a twisted-pair
crossover cable.
Remote Administration of the device
Step 1: Connect the administrative Ethernet port in the main controlling board to a
HUB with a standard network cable. Step 2: Connect the Hub to an administrative workstation in the local area network. Or: Step 1: Connect the administrative Ethernet port in the main controlling board to a
Router with a crossover network cable. Step 2: Connect the router to an administrative workstation in the wide area
network.
2.6.6 SFP transceiver installation
In the C700, each line card with a 1000BASE fiber interface provides several SFP
1000BASE transceiver slots. The procedure for installing the SFP 1000BASE fiber transceiver is shown below: Step 1: Put on a ESD wrist strap (or antistatic gloves) Step 2: Insert the SFP transceiver onto the guide rail inside the 1000BASE fiber
interface line card Do not put the SFP transceiver up-side-down.
Step 3: Push the SFP transceiver along the guide rail gently until you feel the transceiver
snap into place at the bottom of the line card.
Note: the SFP 1000BASE fiber transceiver is hot swappable.
Notice
Page 92
C700 InstallManual Chapter 2 Hardware Installation
2-20
Do not stare directly at the 2 fiber bore in the SFP 1000Base fiber transceiver when
the switch is in operation. The laser may hurt your eyes.
2.6.7 Copper Cable/Fiber Cable Connection
Ethernet cable connection:
Step 1: Insert one end of the Ethernet cable into the RJ-45 Ethernet port in the switch copper cable line card; Step 2: Insert the other end of the Ethernet cable into the RJ-45 Ethernet port of the
other device;
Step 3: Check all status indicators for the corresponding ports, a lighted LINK indicates
the link has been established, otherwise the link is not ready and the cable should be examined;
Upon connection, please verify the sign above the port to avoid use of other ports,
which might damage to the modules or the switch.
The connection procedure for fibers is listed below:
Step 1: Remove the protective dust plug from the SFP/XENPAK fiber transceiver bore; take out the fiber cable and remove the protective cap from one end of the fiber cable. Keep the fiber end clean and neat. Step 2: Immediately attach the end of the fiber cable to the SFP/XENPAK transceiver, and the other end to the transceiver of the corresponding device. Note: Upon connection,
the SFP/XENPAK transceiver‟s TX port should be connected to the RX port of the
corresponding device, and vice versa. Step 3: Check the fiber port status indicator, a lighted LINK indicates that the link has been established, otherwise the link is not ready and should be examined.
Upon connection, please verify the sign above the port to avoid using other ports,
which might damage the transceiver or the other ports. When connecting the other device through fiber cable to the switch, the output power of the fiber must not exceed the maximum received power of the corresponding modules, otherwise, it will damage the switch. Do not stare at the fiber bore when the switch is in
Notice
Notice
Page 93
C700 InstallManual Chapter 2 Hardware Installation
2-21
operation to avoid harm.
2.6.8 Power supply connection
Connection procedures for the AC power supply module are described below:
Step 1: Insert one end of electrical line into the power supply socket and another end
into the corresponding socket of the switch; when connecting electrical lines, it shall be confirmed that the power supply modules are power off.
Step 2: It shall be examined whether or not the fan on the power supply module
operates normally. If the fan fails to operate, please examine whether the power supply socket is power on and whether the power supply module are inserted and locked properly.
Step 3: Turn on the power supply modules (if there are two power supply modules, both
of them shall be turned on.), and examine whether or not the indicator of the indicator of the front panel is normal. If the OUTPUT GOOD indicator fails to be on, please turn off the power supply without delay and examine the status of power supply and each inserting plate.
If the Power OK indicator does not illuminate after repeating the above steps, please
contact the dealer. Do not open the switch chassis by yourself. Please contact the dealer in the case of any failure.
Notice
Loading...