Fourgroup DUPLEX-UP Use And Installation Manual

DUPLEX-UP
USE AND INSTALLATION HANDBOOK
CONTROL PANEL FOR 2 ELECTRIC PUMPS WITH CURRENT CONTROL .
PR .T : FG006172
Date : 10/02/14
Rev . 01
Via Enrico Fermi 8 - 35020 Polverara PD
Tel.049/9772407 Fax.049/9772289
www.fourgroup.it E-mail : info@fourgroup.it
2
1. Warnings
page………3
2. Overview
page ………4
3. Handling
page ………4
4. Application and working limits
page ……….5
5. Standard operations
page ……….6
6. Installation
page ……….7-8
7. Electrical connection
page ……….9-10
8. Regulation and calibration
page ……….11
9. Stop of the pumps
page ……….12
10. Lights and push-buttons
page ……….12
11. Maintenance
page ……….13
12. Waste disposal
page ……….13
13. Warranty
page ……….14
14. Spare parts
page ……….14
15. Conformity declaration
page ……….15
16. Connection diagrams
page ……….16
INDEX
3
The following symbols, accompanied by the words: “Danger”, “Warning”, indicate the potential hazard resulting from failure to observe the associated warning, as specified below:
Failure to observe this warning may result in electric shock
Failure to observe this warning may cause personal injury and/or damage to property
Failure to observe this warning may cause damage to the pump, the unit or the system
- CAUTION:
Make sure the pumps are fully primed before you start them.
- CAUTION:
The control panel must be connected by a qualified electrician in compliance with the electrical regulations in force.
- CAUTION:
The electric pump or the motor and the panel must be connected to an efficient grounding system in compliance with the electrical regulations locally in force.
- CAUTION:
Ground the unit before carrying out any other operation.
- CAUTION:
The electric pump or the motor can start up automatically.
- CAUTION:
As a general rule, always disconnect the power supply before proceeding to carry out any operation on the electrical or mechanical components of the unit or system.
1. WARNINGS
DANGER RISK OF ELECTRI C SHOCK
DANGER
WARNING
4
The purpose of this manual is to provide the necessary information for the proper installation, use and maintenance of DUPLEX-UP. The user should read this manual before operating the unit. Improper use may cause damage to the machine and lead to the forfeiture of the warranty coverage. Always specify the model identification code and the construction number when requesting technical information or spare parts from our Sales and Service department. The instruction and warnings given below concern the standard version; refer to the sale contract documentation for modifications and special version characteristics. For instructions, situations and events not considered in this manual or in the sale documents, please contact our customer service.
Our units must be installed in sheltered, well-ventilated, non-hazardous environments and must be used at a maximum temperature of +40°C and minimum of -5°C.
DANGER
WARNING
The panel must be handled with care, as falls and knocks can cause damage without any visible external signs.
If for any reason the unit is not installed and starter immediately after it has reached its destination it must be stored properly. The external packaging and the separately packed accessories must remain intact, and the whole must be protected from the weather, especially from freezing temperatures, and from any knocks or falls.
PRELIMINARY INSPECTION: after you have removed the external packaging, visually inspect the control panel to make sure it has suffered no damage during shipping. If any damage is visible, inform a FOURGROUP dealer as soon as possible, no later than five days from the delivery date.
2. OVERVIEW
3. HANDLING
5
DANGER RISK OF ELECTRIC SHOCK
WARNING
The DUPLEX-UP is designed for controlling two motors or electric pumps used in pressurization systems or in applications for emptying wells or water tanks with multi-contact float switches.
FOURGROUP S.r.l. shall not be liable for any damage caused or suffered by the unit as a result of its unauthorised or improper use.
TECHNICAL FEATURES :
• Electronic control panel;
• Input voltage 1~50/60 Hz 230V ±10% (single-phase model DUPLEX-UP-M);
• Input voltage 3~50/60 Hz 400V ±10% (three-phase model DUPLEX-UP-T);
• Very low voltage input for float switch of stop;
• Very low voltage input for n.2 float switches of start;
• Very low voltage input for max level alarm float switch;
• Very low voltage input for n.2 motors Klixon;
• Pumps’ exchanger circuit with 4” delay between the starts of the 2 pumps;
• Possibility to exclude a damaged pump;
• Internal selector for exclusion of pumps exchanger;
• Push-buttons for AUTO-OFF-MANUAL motor operation (MANUAL temporary);
• Green led for power on;
• N.2 green led for motors operating;
• N.2 green led for auto operation;
• Red led for water level alarm;
• N.2 red led for overload motors protection alarm;
• N.2 red led for alarm: motor’s Klixon active;
• N.2 push button for restoration from protection;
• Adjustable electronic protection for motors overload;
• Time for activation of protection: 5”;
• Auxiliary circuits protection fuse;
• Motors protection fuses;
• Alarm output with exchangeable contacts 5 A 250V (resistive load);
• Main switch with door interlock;
• Single-phase model adapted for the insertion of a capacitor (not included);
• Box in ABS;
• Output with cable holder;
• Protection IP55;
• Ambient temperature: -5/+40 °C;
• Relative humidity 50% at 40 °C (not condensed).
Do not use the product in environments where dust, acids, corrosive and/or flammable gases etc. are present.
4. APPLICATION AND WORKING