Fountaine Pajot SUMMERLAND 40 LC User Manual

Page 1
Page 2
DAD.MDP.026.003_a not contractual document 2/31
Sommaire
NAVIGATION
A) Leaving port .................................................................................................................................................... Page 3
C) Navigation .................................................................................................................................................... Page 10
D) Anchor .......................................................................................................................................................... Page 11
Setting the anchor ........................................................................................................................................ Page 11
Raising the anchor ....................................................................................................................................... Page 12
CONFORT
A) Electrical installations ................................................................................................................................. Page 15
B) The refrigeration system .............................................................................................................................. Page 17
C) Gas system ................................................................................................................................................ Page 18
D) Water ........................................................................................................................................................... Page 19
1) Freshwater system .................................................................................................................................. Page 19
2) Use of toilet .............................................................................................................................................. Page 20
3) Use of holding tanks ................................................................................................................................ Page 21
4) Discharge shower .................................................................................................................................... Page 22
5) Drainage .................................................................................................................................................. Page 23
Page 3
DAD.MDP.026.003_a not contractual document 3/31
NAVIGATION
A) Départ du port:
Unlock
all doors and lockers, and
c
heck
that the bilges
are free of water.
Close all hull portlights and deck hatches.
Fill :
. the water tanks from the plug situated in front of
the bridge.
. diesel tanks from the plugs situated on the back
port and starboard.
water gasoil gasoil
Check the levels of water and diesel with gauges at the helm station (chart table).
Page 4
DAD.MDP.026.003_a not contractual document 4/31
Put in p
lace
outside the safety equipment (horseshoe
buoys, life raft, ...).
Check
for the absence of fuel and gas vapors inside the
boat.
Switch on
remote-controlled battery circuit breakers switches at the entrance to the saloon or manually in engines compartments.
starboard compartment port compartment
Page 5
DAD.MDP.026.003_a not contractual document 5/31
Check that the valve of the circuit of water of cooling is opened. Start the engine.
See B for a detailed description of the starting procedure.
Check
that cooling water is discharged from the exhaust
and the anti-siphon thru-hull skin fitting. In case of a fault, carefully read the engine manual.
Valve
Exhaust
anti-siphon thru-hull skin
fitting
Page 6
Switch on the electronic equipment: speedo, log, GPS, VHF,...according to the option installed. In strong winds, carefully chock or lash down anything that might move. Check that the navigation lights are working before a night passage.
Inside helm station
Outside helm station
Page 7
DAD.MDP.026.003_a not contractual document 7/31
B) Moteurs :
VOLVO D3 150CV with EVC electronic command system
Page 8
DAD.MDP.026.003_a not contractual document 8/31
Page 9
DAD.MDP.026.003_a not contractual document 9/31
1) Starting the engine
Page 10
DAD.MDP.026.003_a not contractual document 10/31
Page 11
DAD.MDP.026.003_a not contractual document 11/31
Caution Do not turn the starter motor for more than ten seconds. Possible exhaust water backflow may damage the engine.
Page 12
DAD.MDP.026.003_a not contractual document 12/31
2)
Stopping.
Page 13
DAD.MDP.026.003_a not contractual document 13/31
Page 14
DAD.MDP.026.003_a not contractual document 14/31
C) Navigation
Engine speeds :
Increase the engine speed steadily to allow engine temperature to rise.
Wide open throttle and cruising engine revs will vary according to the engines on board.
See engine instruction book.
These engine speeds are subject to the sea state and speed must be reduced with increasing swell.
Page 15
DAD.MDP.026.003_a not contractual document 15/31
D) Mouillage :
Check that the port
engine
is running.
Check that the circuit breaker windlass is switched on
(aft port compartment).
Circuit breaker windlass
Page 16
DAD.MDP.026.003_a not contractual document 16/31
The command is made by the remote control of ascent and descent. (chain locker)
Command situation
Page 17
DAD.MDP.026.003_a not contractual document 17/31
Setting the anchor
Unhook
the safety tackle, lower the anchor and the chain
to the last few metres of the final desired length.
Attach onto the chain, the snap shackle from the bridle waiting in the anchor locker.
Page 18
DAD.MDP.026.003_a not contractual document 18/31
Let out the end of the length of chain
desired until the tension of the mooring gear has been taken up by the bridle. ce que la tension du mouillage soit reprise par la patte d’oie.
Raising the anchor.
Raise
the anchor as far as the bridle’s snap shackle and
undo the snap shackle from the bridle.
Page 19
DAD.MDP.026.003_a not contractual document 19/31
Raise the anchor slowly, making sure that the anchor is put into the anchor roller correctly.
.
Page 20
DAD.MDP.026.003_a not contractual document 20/31
Block the chain with the tackle intended for that use
Caution When running, keep clear of the windlass and the
chain. In particular, pay a big attention on the protection of hands and feet.
If the load on the windlass is too great, the circuit breaker will operate. Switch it back on to set the windlass running again.
Page 21
DAD.MDP.026.003_a not contractual document 21/31
E)
On arrival in port:
Stopping the engines
(see part B for a detailed description of the stopping procedure)
Switch
off
all electrical installations.
Close all gas supply valves (on tank and appliances).
Check
that the bilges are free of water.
Switch off the battery switches during extended stops. Close the valves of the gas oil tank during extended
stops. They are located under the floors in the passageways.
Battery switches
Gaz valves
Page 22
DAD.MDP.026.003_a not contractual document 22/31
CONFORT
A) Electrical installations :
1) Circuit 12V.
Page 23
DAD.MDP.026.003_a not contractual document 23/31
2) 220V alternating current (AC) system : (optional)
Connect
the
shore power cord
by unwinding it
completely or start the generator set.
Regularly check the state of the cable. If the cable is damaged, to replace it by an identical cable.
Caution
Never connect a shore power cord when the
plug is wet.
Control panel 220V
Page 24
DAD.MDP.026.003_a not contractual document 24/31
Turn
shore / generator
changeover switch
to the right
position Check the presence of the current thank to the light on
the differential earth-leak circuit breaker.
Switch on
the differential earth-leak circuit breaker and the circuit breaker of the desired function (starboard engine compartment).
Page 25
DAD.MDP.026.003_a not contractual document 25/31
B) The refrigeration system :
12 V-Refrigerator
Check the state of load of the park battery service on the
voltmeter of the electrical panel. The start-up is done via the thermostat. Set the
refrigerators thermostat to the desired temperature. (For the maintenance, see the builder manual)
Page 26
DAD.MDP.026.003_a not contractual document 26/31
C) Gaz :
Open
the regulator stop valve fixed directly on the tank
Open
the main stop valve and the stop valve of the
appliance to be used (galley locker).
Each gas appliance
is equipped with a safety system. To
light it, keep the button pressed down.
Caution : Ventilate during the use.
Page 27
DAD.MDP.026.003_a not contractual document 27/31
D) Water :
1)
Freshwater system.
Open the tank valve. « Eau douce » sous la trappe de
plancher de la cabine arrière bâbord.
Valve
Check that
the
water heat
er
supply valve (port engine
compartment) is always opened.
Valve
Switch on the
freshwater pump
function
on the
electrical distribution panel
Page 28
DAD.MDP.026.003_a not contractual document 28/31
The deck shower is shut-off with a valve.
2)
Use of toilet.
Check that
the sea water supply and evacuation valves for toilet) are opened. Under the floor in front starboard side.
Place
the toilet lever to the “Water in” position and pump for at least 10 strokes to evacuate and dilute the black water.
Page 29
DAD.MDP.026.003_a not contractual document 29/31
Place the toilet lever to the “Evacuation” position and pump for several strokes to completely empty the pan.
Repeat the operation at least twice.
3)
Use of holding tanks.
To store
the black water
in the holding tank :
close
the
discharge seacock.
Caution :
Never force the pump Storage capacity : 45 litre.
Regularly empty
the holding tank :
. directly to the sea by opening the discharge
seacock: Open the gate of evacuation only to the wide.
. on the dock by pumping from the “Waste” deck
plate. « Waste ».
Page 30
DAD.MDP.026.003_a not contractual document 30/31
4)
Discharge shower.
Open the discharge valve
situated in the cupboard of
each bathroom
In bathroom
Page 31
DAD.MDP.026.003_a not contractual document 31/31
6)
Drainage
Cockpit compartment
:
Hand pump
Open and unfold the manual pump located on the back trunk of the cockpit. Pipe stored inside the back locker of the cockpit.
Engine compartment:
Electrical bilge pump
Switch on the function at the electrical distribution panel.Switch off from the end.
3 possible positions : -On
-Off
-Temporary
. Hull :
Electrical bilge pump
Switch on the function at the electrical distribution panel.Switch off from the end.
3 possible positions : -On
-Off
- Temporary
Loading...