Fostex 6301B User Manual

Typical Connections
In most applications, line level signals from mixers such as the FOSTEX Multitracker will be used to drive the 6301B Personal Monitor.
6301B
SETUP
SYSTEM MIDI
CURRENT SCENE STATUS
KEY MODE
ROUTING/ PAIR/ PHASE GROUP
MMC SEND
CHANNEL/
CH VIEW
METER
FADER MODE
AUX1 AUX2
AUX3 AUX4
ADD.AUX
EFF1 EFF2
CHANNEL
ANALOG INANALOG IN
ADAT IN
EFF REFF RTNTN
PAGE SELECT
9-16 ADAT IN
1-8 ANALOG IN
EQ/LO
EQ/LO-MID
GAIN
GAIN
Q
Q
FREQ
FREQ
EQ EDIT EQ EDIT
EQ EDIT EQ EDIT
EQ EDIT
SOLO SOLO SOLO SOLO SOLO SOLO SOLO
ON ON ON ON ON ON ON
+10
+10
+10
+10
+10
0
0
0
0
0
-10
-10
-10
-10
-10
-20
-20
-20
-20
-20
-30
-30
-30
-30
-30
-40
-40
-40
-40
-40
-
-
-
-
-
1 2 3
4
1211109
20
19
18
17
METER OL
-3
-6
-9
-12
-18
-24
-36
-40 LR ST BUSS/SOLO
17-20 EFF RTN
SELECTED EQ
EQ/HI-MID
EQ/HI-MID
EQ ON
GAIN
GAIN
EQ LIBRARY
Q
Q
FREQ
FREQ
STORERECALL
PAN
PANPA NPANPANPANPAN
PAN
EQ EDIT
EQ EDIT EQ EDIT
REC BUSS
SOLO
SOLO
SOLO
ON ON
EXIT
+10
+10
+10
0
0
0
0
-10
-20
-10
-10
-10
-30 ENTER
-20
-20
-20
-40
-30
-30
-30
-60
-40
-40
-40
-
-
-
-
8
765
MASTER
1413
15
16
6301B
EFF EDIT
EFF 2EFF 1
EFF LIBRARY
STORERECALL
SCENE MEMORY
STORERECALL
+1/
/-1
DATA
Connections Typiques
Dans la plupart des applications seront connectes des signaux au niveau ligne tels qu’issus de melangeurs ou l’enregistrour multipistes de FOSTEX.
Keyboard
´
´
Microphone GuitarMixing console
Model
Modele
PERSONAL MONITOR Self-Powered
`
Spesifications
Speaker section
Type 10cm full range single cone Impedance 4 Output sound 84dB (W/m)
pressure level
Frequency range 80Hz ~ 13kHz
Amplifier section (EXT SP jack)
Output Higher than 10W RMS (8 load) Freq. range 20Hz ~ 50kHz (0dB, -3dB) Distortion 0.05% at 1W output Residual noise -70dBV (0.3mV) Minimum input Unbalanced Type: -6dBV (0.5V RMS)
sensitivity (for Balanced Type: +4dBm (1.2V RMS) maximum output)
Input impedance Unbalanced Type: Higher than 20k
Mains power 120VAC 60Hz (USA/Canada) 33W
Dimensions 188 (H) x 120 (W) x 118 (D) mm Weight 3.0kg (6.6 Ibs)
Rating and physical appearance subject to change without prior notice.
Balanced Type: Higher than 10k
230V~ 50/60Hz (Europe) 33W 240V~ 50Hz (U.K./Australia) 33W
Spesifications
Haut Parleur (Interne)
Type: 10cm range bande Impedance: 4 ohms Niveau d’Entree Nominal:-10dBv Bande Passante: 80Hz - 13kHz
Amplificateur
Puissance de Sortie: > 10W RMS (sous 8 ohms) Bande Passante: 20Hz ~ 50kHz, 0dB, -3dB Distortion: 0.05% (a 1W) Bruit de Fond: -70dBv (0.3mV) Sensibilite Mini: Non-balancee Type: -6dBV
Impedance d’Entree: Non-balancee Type: > 20k
Alimentation: 120VAC 60Hz (USA/Canada) 33W
Dimensions: 188 (H) x 120 (L) x 118 (P) millim. Poids: 3kg
Les caractenstiques et I’apparence physique sont sujettes a modi­fications sans preavis.
´
´
(0.5V RMS)
´
Balancee Type: +4dBm (1.2V RMS)
´
ohms
´
Balancee Type: > 10k ohms
230V - 50/60Hz (Europe) 33W 240V - 50Hz (R.U./Australie) 33W
´
FOR HOUSEHOLD USE ONLY . USAGE DOMESTIQUE SEULEMENT.
FOSTEX CO. 3-2-35, Musashino, Akishima-shi, Tokyo, Japan 196-0021 FOSTEX AMERICA 15431, Blackburn Ave., Norwalk, CA 90650, U.S.A.
© PRINTED IN CHINA MAY 2004 8288333200 (403522)
Owner’ s Man ual
Fostex Model 6301B Personal Monitor Speaker can perfectly handle a wide variety of monitoring applications. It can monitor any level of line signals. The Model 6301B can be directly connected to the outputs of tape recorders and electronic musical instru­ments, or through recording mixers and multitrackers. There are T wo Versions in the Model 6301B. The one is the Balanced T ype equipped with both 1/4 inch Phone Jack and Cannon T ype Jack. The other one is the Un-
`
balanced Type equipped with 1/4 inch Phone Jack only .
Manuel d’Utilisation
Le haut-parleur de controle personnel modele 6301B de Fostex est parfaitement
`
´´
adapte a un large eventail d’applications controle. II est capable de capter tout niveau
`
^
de signaux de ligne. Le modele 6301B peut
^
etre directement raccorde a la sortie de magnetetophones et d’instruments de
´
musique electroniques ou via des tables de
´ mixage et des systemes multipistes. Le modele 6301B existe en deux versions. La
`
premiere version est le type compense avec
` price casque 1/4 pouce et prise type encastre. L’autre version est le type non compense avec
^
`
´
`
`
´
´
´
prise casque 1/4 pouce uniquement.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER - SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
"WARNING"
"TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE."
SAFETY INSTRUCTIONS
1. Read Instructions - All the safety and operating instructions should be read before the appliance is operated.
2. Retain Instructions - The safety and operating instructions should be retained for future reference.
3. Heed Warnings - All warnings on the appliance and in the operating instructions should be adhered to.
4. Follow Instructions - All operating and use instructions should be followed.
5. Water and Moisture - The appliance should not be used near water - for example, near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, and the like.
6. Carts and Stands - The appliance should be used only with a cart or stand that is recommended by the manufacturer.
An appliance and cart combination should be moved with care. Quick stops, excessive force, and uneven surfaces may cause the appliance and cart combination to overturn.
7. Wall or Ceiling Mounting - The appliance should be mounted to a wall or ceiling only as recommended by the manufacturer.
8. Ventilation - The appliance should be situated so that its location or position dose not interfere with its proper ventilation. For example, the appliance should not be situated on a bed, sofa, rug, or similar surface that may block the ventilation openings; or, placed in a built-in installation, such as a bookcase or cabinet that may impede the flow of air through the ventilation openings.
9. Heat - The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
10. Power Sources - The appliance should be connected to a power supply only of the type described in the operating instructions or as marked on the appliance.
CAUTION:
TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO WIDE SLOT, FULLY INSERT.
ATTENTION:
´
POUR EVITER LES CHOCS ELECTRIQUES, INTRODUIRE LA LAME LA PLUS LARGE DE LA FICHE DANS LA BORNE CORRESPONDANTE DE LA PRISE ET POUSSER JUSQU' AU FOND.
The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
11. Grounding or Polarization - The precautions that should be taken so that the grounding or polarization means of an appliance is not defeated.
12. Power Cord Protection - Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, convenience receptacles, and the point where they exit from the appliance.
13. Cleaning - The appliance should be cleaned only as recommended by the manufacturer.
14. Nonuse Periods - The power cord of the appliance should be unplugged from the outlet when left unused for a long period of time.
15. Object and Liquid Entry - Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through openings.
16. Damage Requiring Service - The appliance should be serviced by qualified service personnel when: A. The power supply cord or the plug has been
damaged; or
B. Objects have fallen, or liquid has been spilled into
the appliance; or C. The appliance has been exposed to rain; or D. The appliance does not appear to operate
normally or exhibits a marked change in
performance; or E. The appliance has been dropped, or the enclosure
damaged.
17. Servicing - The user should not attempt to service the appliance beyond that described in the operating instructions. All other servicing should be referred to qualified service personnel.
18. The appliance should be situated away from drops of water or spray of water.
19. Objects containing liquid such as vase must not be put on the appliance.
20. The appliance is not completely isolated from the power supply even if the power switch is at off position.
´
Notes on Operating
The front panel volume control must always be set to minimum when switching on the monitor amplifier or plugging the cable into the input jack. The volume control is then advanced to a com­fortable listening level. The internal power ampli­fier is protected against overloading, such as at short term accidental short circuiting when an external speaker is plugged into the rear panel jack, by an automatic recovery protection sircuit.
A.C. P ower Source
Fostex Model 6301B can be used in any location where AC voltage is. Please refer to specifica­tions for details. The LED will light to indicate the operating mode when the power switch is pushed ON.
Sound V olume
A control knob for adjusting the sound level is provided on the front panel. With the control knob turned full clockwise, maximum output is obtained by 0.5V (-6dBV), or in the Balanced Type, by 1.2V (+4dBm), respectively, at the input jack.
Input and Ext SP
The INPUT and EXT SP inputs are the standard 1/4 inch phone jacks. The Balanced T ype, in ad­dition, have a Cannon connector the rated input level is -10dBV and is +4dBm for the Balanced Type. The internal power amplifier can drive an external speaker via the EXT SP jack.
Operating Method
Line level signals from the Fostex recording mix­ers and multitrackers are sufficient for driving the Model 6301B and can be directly connected to these outputs.
Note: The internal speaker is disconnected when the Output terminal is engaged.
Mode d’emploi
Toujours regler la commande de volume du panneau avant sur minimum avant de commuter sur l’amplificateur de controle ou de brancher le
^
cable a la prise d’entree. Regler ensuite la commande de volume sur le niveau souhaite. L’amplificateur de puissance interne est protege par un circuit a retablissement automatique contre les surcharges du type court-circuit accidentel instantane au raccordement d’un haut-parleur externe a la prise arriere.
Alimentation electrique ca
Le modele Fostex 6301B peut etre utilise partout
`
ou une alimentation AC est disponible. Nous vous prions de vous reporter aux caracteriques pour les details. Une diodetemoin s’allume pour indiquer la mise sous tension quand I’interrupeur d’alimentation est mis sur ON (marche).
´
^
`
´´
´
´
`
´
``
´
´´
^
´
´
V olume du son
Le bouton de commande du volume du son se trouve a l’avant. En position a fond a droite, la
`
puissance maxi obtenue au jack d’entree est de
0.5V (-6dBV) ou de 1.2V (+4dBm) pour le modele type compense.
´
Entrees INPUT et EXT SP
Les entrees INPUT et EXT SP sont des prises
´
´ casque standards 1/4 pouce. Le modele de type compense est de plus pourvu d’un connecteur encastre. Le niveau d’entree nominal est de ­10dBV pour le modele non compense et de +4dBm pour le modele compence. L’amplificateur
´
´
`
` de puissance interne peut egalement commander un hautparleur externe par raccodement a la prise EXT SP.
Mode operatoire
´
Les signaux de niveau de ligne des tables de mixage et des systemes multipistes Fostex sont
` suffisants pour commander le modele 6301B et pouvont etre raccordes directement a ces sorties.
^
´
Nota: Le haut-parleur interne est mis hors circuit quand la borne Output (sortie) est engagee.
`
`
´
`
`
´
´
´
´
`
` `
´
´
´