Fortinet FortiManager-1000C Rack And Hardware Install Manual

Page 1
FortiManager-1000C™
Version 4.0
Rack and Hardware Install Gu id e
Page 2
FortiManager-1000C™ Rack and Hardware Install Guide
Version 4.0 26 October 2009 02-40000-112634-20091026 © Copyright 2009 Fortinet, Inc. All rights reserved. No part of this publication including text, examples,
Trademarks
Dynamic Threat Prevention System (DTPS), APSecure, FortiASIC, FortiBIOS, FortiBridge, FortiClient, FortiGate®, FortiGate Unified Threat Management System, FortiGuard®, FortiGuard-Antispam, FortiGuard-Antivirus, FortiGuard-Intrusion, FortiGuard-Web, FortiLog, FortiAnalyzer, FortiManager, Fortinet®, FortiOS, FortiPartner, FortiProtect, FortiReporter, FortiResponse, FortiShield , Fo rtiVoIP, and FortiWiFi are trademarks of Fortinet, Inc. in the United States and/or other countries. The names of actual companies and products mentioned herein may be the trademarks of their respective owners.
Regulatory compliance
FCC Class A/Class B Part 15 CSA/CUS
Caution: Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions
Page 3

Contents

Contents
Introduction.............................................................................................. 3
Registering your Fortinet product....................................... ... ... .................................... 3
Customer service and technical support...................................................................... 3
Fortinet documentation ................................................................................................. 4
Fortinet Tools and Documentation CD ....................................................................... 4
Fortinet Knowledge Center ........................................................................................ 4
Comments on Fortinet technical documentation ....................................................... 4
Conventions .................................................................................................................... 4
IP addresses.... ... .............................................................. ... ... ... .... ... .......................... 4
CLI constraints............................................................................................................ 4
Notes, Tips and Cautions .......................... ... .... ... ....................................................... 4
Typographical conventions......................................................................................... 5
Rack Installation Instructions................................................................. 7
Removing the system from the rack......................................................................... 14
Cable Management Arm Installation ........................................................................... 14
Installing the Bezel........................................................................................................ 19
Connecting the Keyboard, Mouse, and Monitor ........................................................ 20
Connecting the Power Cables ...... ... ... .... ... ... ... .... ... ... ... ... .... ... ..................................... 21
Installing the Power Cord Retention Bracket............................................................. 21
Turning on the System ................................................................................................. 22
Installing Hard Drives............................................................................ 23
Hard Drives............................................................................................................... 23
Removing a Hard-Drive Blank............................................................................ 23
Installing a Hard-Drive Blank.............................................................................. 23
Removing a Hot-Swap Hard Drive..................................................................... 23
Installing a Hot-Swap Hard Drive....................................................................... 24
Removing a Hard Drive From a Hard-Drive Carrier........................................... 25
Installing a Hard Drive Into a Hard-Drive Carrier ... .... ........................................ 25
Installing a Hard Drive Into a Hard-Drive Carrier...................................................... 25
Index........................................................................................................ 27
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 1
http://docs.fortinet.com/Feedback
Page 4
Contents
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide
2 02-40000-112634-20091026
http://docs.fortinet.com/Feedback
Page 5
Introduction Registering your Fortinet product

Introduction

Welcome and thank you for selecting Fortinet products for your network protection. Fortinet
network misuse and abuse, and help you use communications resources more efficiently without compromising the performance of your network. Fortinet systems are ICSA­certified for Antivirus, Firewall, IPSec, SSL- TLS, IPS, Intrusion detection, an d AntiS pyware services.
Fortinet systems are dedicated, easily managed security devices that deliver a full suite of capabilities including:
Application-level services such as virus protection, intrusion protection, spam filtering,
Network-level services such as firewall, intrusion detection, IPSec and SSL VPN, and
Management services such as user authentication, logging, reporting with
The Fortinet security system uses Fortinet’s Dynamic Threat Prevention System (DTPS™) technology, which leverages breakthroughs in chip design, networking, security and content analysis. The unique ASIC-accelerated architecture analyzes content and behavior in real-time, enabling key applications to be deployed right at the network edge where they are most effective at protecting your networks.
This chapter contains the following topics:
Registering your Fortinet product
Customer service and technical support
Fortinet documentation
Conventions
®
ASIC-accelerated multi-threat security systems improve network security, reduce
web content filtering, IM, P2P, and VoIP filtering
traffic shaping
FortiAnalyzer, administration profiles, secure web and CLI administrative access, and SNMP.

Registering your Fortinet product

Before you begin, take a moment to registe r your Fortinet product at the Fortinet Technica l Support web site, https://support.fortinet.com.
Many Fortinet customer services, such as firmware updates, technical support, and FortiGuard Antivirus and other FortiGuard services, require product registration.
For more information, see the Fortinet Knowledge Center article Registration Frequently
Asked Questions.

Customer service and technical support

Fortinet Technical Support provides services designed to make sure that your Fortinet products install quickly, configure easily, and operate reliably in your network.
To learn about the technical support services that Fortinet provides, visit the Fortinet Technical Support web site at https://support.fortinet.com.
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 3
http://docs.fortinet.com/Feedback
Page 6
Fortinet documentation Introduction
You can dramatically improve the time that it takes to resolve your technical support ticket by providing your configuration file, a network diagram, and other specific information. For a list of required information, see the Fortinet Knowledge Center article What does
Fortinet Technical Support require in order to best assist the customer?

Fortinet documentation

The Fortinet Technical Documentation web site, http://docs.fortinet.com, provides the most up-to-date versions of Fortinet publications, as well as additional technical documentation such as technical notes.
In addition to the Fortinet Technical Documentation web site, you can find Fortinet technical documentation on the Fortin et Tools and Document ation CD, a nd on the Fortinet Knowledge Center.

Fortinet Tools and Documentation CD

Many Fortinet publications are available on the Fortinet Tools and Documentation CD shipped with your Fortinet product. The documents on this CD are current at shipping time. For current versions of Fortinet documentation, visit the F ortin et Technical Documentation web site, http://docs.fortinet.com.

Fortinet Knowledge Center

Comments on Fortinet technical documentation

Conventions

IP addresses

CLI constraints

The Fortinet Knowledge Center provides additional Fortinet technical documentation, such as troubleshooting and how-to-articles, examples, FAQs, technical notes, a glossary, and more. Visit the Fortinet Knowledge Center at http://kb.fortinet.com.
Please send information about any errors or omissions in this or any Fortinet technica l document to techdoc@fortinet.com.
Fortinet technical documentation uses the conventions described below.
To avoid publication of public IP addresses that belong to Fortinet or any other organization, the IP addresses used in Fortinet technical documentation are fictional and follow the documentation guidelines specific to Fortinet. The addresses used ar e from the private IP address ranges defined in RFC 1918: Address Allocation for Private Internets, available at http://ietf.org/rfc/rfc1918.txt?number-1918.
CLI constraints, such as <address_ipv4>, indicate which data types or string patterns are acceptable input for a given parameter or variable value. CLI constraint conventions are described in the CLI Reference document for each product.

Notes, Tips and Cautions

Fortinet technical documentation uses the following guidance and styles for notes, tips and cautions.
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide
4 02-40000-112634-20091026
http://docs.fortinet.com/Feedback
Page 7
Introduction Conventions
Tip: Highl ights useful additional information, often tailored to your workplace activity.
Note: Also presents useful information, but usually focused on an alternative, optional
method, such as a shortcut, to perform a step.
Caution: Warns you about commands or procedures that could have unexpected or undesirable results including loss of data or damage to equipment.

Typographical conventions

Fortinet documentation uses the following typographical conventions:
Table 1: Typographical conventions in Fortinet technical documentation
Convention Example Button, menu, text box,
field, or check box label CLI input config system dns
CLI output FGT-602803030703 # get system settings
Emphasis HTTP connections are not secure and can be intercepted by
File content <HTML><HEAD><TITLE>Firewall
Hyperlink Visit the Fortinet Technical Support web site,
Keyboard entry Type a name for the remote VPN peer or client, such as
Navigation Go to VPN > IPSEC > Auto Key (IKE). Publication For details, see the
From Minimum log level, select Notification.
set primary <address_ipv4>
end
comments : (null) opmode : nat
a third party.
Authentication</TITLE></HEAD> <BODY><H4>You must authenticate to use this service.</H4>
https://support.fortinet.com.
Central_Office_1.
FortiGate Administration Guide.
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 5
http://docs.fortinet.com/Feedback
Page 8
Conventions Introduction
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide
6 02-40000-112634-20091026
http://docs.fortinet.com/Feedback
Page 9

Rack Installation Instructions

1
3
2
4
Rack Installation Instructions
The FortiManager-1000C comes with a sliding rail kit. Use the instructions below to install the rails.
Caution: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before you begin, review the safety instructions that came with the system.
Note: The illustrations in this document are not intended to represent a specific server .
To install the sliding rail kit 1 Locate the components for installing the rail kit assembly:
Two sliding rail assemblies (1)
Two chassis rail members (2)
Two Velcro straps (3)
Two cable management arm (CMA) attachment brackets (4)
Figure 1: Rail kit contents
2 To install the rails in square-hole racks, do the following:
Position the left and right rail end pieces of the rail module labeled FRONT facing inward and orient each end piece to seat in the squar e holes on the front side of the vertical rack flanges (5).
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 7
http://docs.fortinet.com/Feedback
Page 10
Figure 2: Installing and removing the rails (square-hole racks)
5
8
7
6
Rack Installation Instructions
Align each end piece to seat the pegs in the bottom hole of the first U and the top hole of the first U (6).
Engage the back end of the rail until it fully seat s on the vertical rack flange and the second “tooth” on the latch locks in place. Repeat these steps to position and seat the front end piece on the vertical flange (7).
To remove the rails, pull on the latch release button on the end piece midpoint and unseat each rail (8).
3 To install the rails in round-hole racks, do the following:
Position the left and right rail end pieces of the rail module labeled FRONT facing inward and orient each end piece to seat in the round holes on the front side of the vertical rack flanges (9).
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide
8 02-40000-112634-20091026
http://docs.fortinet.com/Feedback
Page 11
Rack Installation Instructions
9
10
11
12
Figure 3: Installing and removing the rails (round-hole racks)
Align each end piece to seat the pegs in the bottom hole of the first U and the top hole of the first U (10).
Engage the back end of the rail until it fully seat s on the vertical rack flange and the first “tooth” on the latch locks in place. Repeat these steps to position and seat the front end piece on the vertical flange (11).
To remove the rails, pull on the latch release button on the end piece midpoint and unseat each rail (12).
4 To install and remove the chassis rail members, do the following:
Place the system on a level surface and align the four keyhole slots on the chassis rail members with the corresponding pins on the system (13).
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 9
http://docs.fortinet.com/Feedback
Page 12
Figure 4: Installing the chassis rail members.
13
14
Rack Installation Instructions
Slide the chassis rail members towards the back of the system until each one locks into place. To remove the chassis rail members, lif t the lock spring until it clea rs the head of the pin (14).
Slide the chassis rail member toward the front of the system until the pins slip through the keyhole slots.
5 To install the system in the rack, do the following:
Ensure that the system is properly supported until the chassis rail members are locked into the slide rails on both sides. Pull the sliding rails out of the rack until they lock into place (15).
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide
10 02-40000-112634-20091026
http://docs.fortinet.com/Feedback
Page 13
Rack Installation Instructions
17
15
16
Figure 5: Installing the system in the rack.
Align and insert the ends of the chassis rail members into the ends of the rails (16).
Push the system inward until the chassis rail members lock into place. Push or pull the blue tab located near the front of the system and slide the system into th e rack (17).
6 To engage and release the slam latch, do the following:
Facing the front, locate the slam latch on either side of the system (18).
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 11
http://docs.fortinet.com/Feedback
Page 14
Figure 6: Engaging and releasing the slam latch
18
19
20
Rack Installation Instructions
The latches engage automatically as the system is pushed into the rack and are released by pulling up on the latches (19).
To secure the system for shipment in the rack or for other unstable environmen ts, locate the hard-mount screw under each latch and tighten each screw with a #2 Phillips screwdriver (20).
7 To install the CMA attachment brackets, do the following:
Locate the CMA attachment bracket marked A and install it at the back of the slide rail marked with a corresponding A (21).
Align the holes on the bracket with the pins on the slide rail and push the bracket forward until it locks into place. Repeat the same process for the CMA attachment bracket marked B.
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide
12 02-40000-112634-20091026
http://docs.fortinet.com/Feedback
Page 15
Rack Installation Instructions
21
22
23
Figure 7: Instal li ng the CMA attachment brackets.
8 To route the cables, do the following:
Bundle the cables gently , pulling them clear of the system connectors to the lef t and the right sides (22).
Figure 8: Routing the cables
Thread the Velcro straps through the tooled slots on the outer or inner CMA brackets on each side of the system to secure the cable bundles (23).
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 13
http://docs.fortinet.com/Feedback
Page 16
Cable Management Arm Installation Rack Installation Instructions
1
2
3

Removing the system from the rack

To remove the system from the rack 1 Pull the system out of the rack until the sliding rails lock into place (1).
Figure 9: Removing the system from the rack
2 Locate the white tabs on the sides of the chassis rail members (2). 3 Pull the tabs towards the front of the system to release the chassis rail members from
the rails. Continue pulling the system until the chassis rail members are completely clear of the rails and place the system on a level surface (3).

Cable Management Arm Installation

The FortiManager-1000C comes with a Cable Management Arm. Use the instr uctions below to install the Cable Management Arm.
Caution: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before you begin, review the safety instructions that came with the system.
Note: The illustrations in this document are not intended to represent a specific server .
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide
14 02-40000-112634-20091026
http://docs.fortinet.com/Feedback
Page 17
Rack Installation Instructions Cable Management Arm Installation
1
2
3
To install the cable management arm 1 Locate the components for installing the Cable Management Arm (CMA) assembly:
Cable Management Arm tray (1)
Cable Management Arm (2)
Nylon cable tie wraps (3)
Figure 10: Cable Management Arm kit contents
Note: To secure the CMA for shipment in the rack, loop the tie wraps around both baskets
and tray and cinch them firmly. For larger CMAs, the tie wraps can be threaded through the inner and outer baskets and around the tray to secure them. Securing the CMA in this manner will also secure your system in unstable environments.
2 To install or remove the Cable Management Arm Tray, do the following:
Note: The CMA tray provides support and acts as a retainer for the CMA.
Align and engage each side of the tray with the receiver brackets on the inner edges of the rails and push forward until the tray clicks into place (4).
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 15
http://docs.fortinet.com/Feedback
Page 18
Cable Management Arm Installation Rack Installation Instructions
6
7
8
4
5
Figure 11: Installing and removing the Cable Management Arm Tray
To remove the tray, squeeze the latch-release buttons on both sides toward the center and pull the tray out of the receiver brackets (5).
3 To install and remove the CMA, do the following:
Note: You can attach the CMA to either the right or left mounting rail, depending on how
you intend to route cables from the system. Mounting the CMA on the side opposite of the power supplies is recommended; otherwise, the CMA must be disco nnected in order to remove the outer power supply. You must remove the tray before removing the power supplies.
At the back of the system, fit the latch on the front end of the CMA on the innermost bracket of the slide assembly until the latch engages (6).
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide
16 02-40000-112634-20091026
http://docs.fortinet.com/Feedback
Page 19
Rack Installation Instructions Cable Management Arm Installation
6
7
8
Figure 12: Installing and re mov in g the Cabl e Ma na ge me nt Arm
Fit the other latch on the end of the outermost bracket until the latch engages (7).
To remove the CMA, disengage both latches by pressing the CMA release buttons at the top of the inner and outer latch housings (8).
4 To move the CMA away from the CMA tray, do the following:
The CMA can be pulled away from the system and extended away from the tray for access and service (9).
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 17
http://docs.fortinet.com/Feedback
Page 20
Cable Management Arm Installation Rack Installation Instructions
9
10
Figure 13: Moving the CMA away from the CMA tray
At the hinged end, lift the CMA up and of f o f the tray to unseat it from the tray catch. Once it is unseated from the tray, swing the CMA away from the system (10).
Note: You can also extend the CMA into the service position once it is cabled to access the back of the system.
5 To cable the system using the CMA, do the following:
Caution: To avoid potential damage from protruding cables, secure any slack in the status
indicator cable before routing this cable through the CMA.
Using the tie wraps provided, bundle the cables together as they enter and exit the baskets so they do not interfere with adjacent systems (11).
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide
18 02-40000-112634-20091026
http://docs.fortinet.com/Feedback
Page 21
Rack Installation Instructions Installing the Bezel
11
12
13
14
15
16
Figure 14: Cabling the system using the CMA
With the CMA in the service position, route the cable bundle through the inner and
Use the preinstalled Velcro straps on either end of the baskets to secure the cables
Adjust the cable slack as needed at the hinge position (14).
Swing the CMA back into place on the tray (15).
Install the status indicator cable at the back of the system and secure the cable by

Installing the Bezel

A lock on the bezel restricts access to the power button, optical drive, and hard drive(s). The LCD panel and navigation buttons are accessible through the front bezel.
To remove the Front Bezel 1 Using the system key, unlock the bezel.
2 Pull up on the release latch next to the key lock. 3 Rotate the left end of the bezel away from the system to release the right end of the
bezel.
4 Pull the bezel away from the system. See Figure 15.
outer baskets (12).
(13).
routing it through the CMA. Attach the other end of this cable to the corner of the outer CMA basket. (16).
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 19
http://docs.fortinet.com/Feedback
Page 22
Connecting the Keyboard, Mouse, and Monitor Rack Installation Instructions
4
3
2
1
Figure 15: Removing the Front Bezel
1 release latch 2 bezel 3 hinge tabs 4 key lock
To install the Front Bezel 1 Insert the hinge tab on the right of the bezel into the slot on the r ight side of the system
front panel.
2 Rotate the left side of the bezel toward the system. 3 Press the bezel to the system to engage the latch.

Connecting the Keyboard, Mouse, and Monitor

Figure 16: Connecting the keyboard, mouse, and monitor
Connect the keyboard, mouse, and monitor (optional). The connectors on the back of your system have icons indicating which cable to plug into
each connector. Be sure to tighten the screws (if any) on the monitor's cable connector.
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide
20 02-40000-112634-20091026
http://docs.fortinet.com/Feedback
Page 23
Rack Installation Instructions Connecting the Power Cables

Connecting the Power Cables

Figure 17: Connecting the power cables.
Connect the system’s power cable(s) to the system and, if a monitor is used, connect the monitor’s power cable to the monitor.

Installing the Power Cord Retention Bracket

Figure 18: Installing the power cord retention bracket
Attach the power cord retention bracket on the right bend of the power supply handle. Bend the system power cable into a loop as shown in the illustration and attach to the bracket’s cable clasp.
Plug the other end of the power cable(s) into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 21
http://docs.fortinet.com/Feedback
Page 24
Turning on the System Rack Installation Instructions

Turning on the System

Figure 19: Turning on the system
Press the power button on the system and the monitor. The power indicators should light.
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide
22 02-40000-112634-20091026
http://docs.fortinet.com/Feedback
Page 25

Installing Hard Drives

2
1
Installing Hard Drives

Hard Drives

Your system supports up to four 3.5-inch SATA hard drives. All drives are installed at the front of the system and connect to the system board through the SAS backplane. Hard drives are supplied in special hot-swappable hard-drive carriers that fit in the hard-drive bays.
Caution: Do not turn off or reboot your system while the drive is being formatted. Doing so can cause a drive failure
When you format a hard drive, allow enough time for the formatting to be completed. Be aware that high-capacity hard drives can take a number of hours to format.

Removing a Hard-Drive Blank

Caution: To maintain proper system cooling, all empty hard-drive bays must have drive
blanks installed
1 Remove the front bezel. See “Installing the Bezel” on page 19. 2 Grasp the front of the hard-drive blank, press the release lever on the right side, and
slide the blank out until it is free of the drive bay. See Figure 1.
Figure 1: Removing and Installing a Hard Drive Blank
1 hard drive blank 2 release lever

Installing a Hard-Drive Blank

Align the hard-drive blank with the drive bay and in sert the blank into the drive bay until the release lever clicks into place.

Removing a Hot-Swap Hard Drive

Caution: Ensure that your operating system supports hot-swap drive removal and
installation. See the documentation provided with your operating system for more information.
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 23
http://docs.fortinet.com/Feedback
Page 26
Installing Hard Drives
2
1
1 If present, remove the front bezel. See “Installing the Bezel” on page 19. 2 From the RAID management software, prepare the drive for removal. Wait until the
hard-drive indicators on the drive carrier signal that the drive can be removed safely. See your storage controller documentation for info rm at ion ab ou t ho t- swa p dr ive removal.
If the drive has been online, the green activity/fault indicator will flash as the drive is powered down. When the drive indicators are off, the drive is ready for removal.
3 Press the button on the front of the drive carrier and open the drive carrier release
handle to release the drive. See Figure 2.
Figure 2: Installing a Hot-Swap Hard Drive
1 release button 2 hard drive carrier handle
4 Slide the hard drive out of the drive bay. 5 Insert a drive blank in the vacated drive bay. See “Installing a Hard-Drive Blank”. 6 If applicable, install the bezel. See “Installing the Bezel” on page 19.

Installing a Hot-Swap Hard Drive

Caution: When installing a hard drive, ensure that the adjacent drives are fully installed.
Inserting a hard-drive carrier and attempting to lock its handle next to a partially installed carrier can damage the partially installed carrier's shield spring and make it unusable.
1 If present, remove the front bezel. See “Installing the Bezel” on page 19. 2 If a drive blank is present in the bay, remove it. See “Removing a Hard-Drive Blank”. 3 Install the hot-swap hard drive.
Press the button on the front of the drive carrier and open the handle.
Insert the hard-drive carrier into the drive bay until th e car rier co ntacts the backplane.
Close the handle to lock the drive in place.
4 If applicable, install the bezel. See “Installing the Bezel” on page 19.
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide
24 02-40000-112634-20091026
http://docs.fortinet.com/Feedback
Page 27
Installing Hard Drives
1
3
2
4

Removing a Hard Drive From a Hard-Drive Carrier

Remove the screws from the slide rails on the hard-drive carrier and separate the hard drive from the carrier. See
Figure 3
.

Installing a Hard Drive Into a Hard-Drive Carrier

1 Insert the hard drive into the hard-drive carrier with the connector e nd of the drive at
the back. See Figure 3.
2 Align the screw holes on the hard drive with the back set of holes on the hard drive
carrier. When aligned correctly, the back of the hard drive will be flush with the back of the
hard-drive carrier.
3 Attach the four screws to secure the hard drive to the hard-drive carrier.
Figure 3: Installing a Hard Drive into a Drive Carrier
1 hard-drive carrier 2 screws (4) 3 hard drive 4 SAS screw hole

Installing a Hard Drive Into a Hard-Drive Carrier

1 Insert the hard drive into the hard-drive carrier with the connector e nd of the drive at
the back. See Figure 4 on page 26.
2 Align the holes on the hard drive with the back set of holes on the hard drive carrier.
When aligned correctly, the back of the hard drive will be flush with the back of the hard-drive carrier.
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 25
http://docs.fortinet.com/Feedback
3 Attach the four screws to secure the hard drive to the hard-drive carrier.
Page 28
Figure 4: Installing a Hard Drive Into a Drive Carrier
4
3
1
2
Installing Hard Drives
1 drive carrier 2 screws (4) 3 hard drive 4 SAS/SATA screw hole
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide
26 02-40000-112634-20091026
http://docs.fortinet.com/Feedback
Page 29

Index

Index
B
bezel
installing, 19
blank
hard drive, 23
C
cable management arm, 14 cable management arm tray, 15 comments, documentation, 4 customer service, 3
D
documentation
commenting on, 4 Fortinet, 4
drive blank
installing, 23 removing, 23
drive carrier
hard drive, 25
F
Fortinet customer service, 3 Fortinet documentation, 4
commenting on, 4
Fortinet Knowledge Center, 4
H
hard drive
drive carrier, 25 installing, 24 removing, 23
hot-swap
hard drives, 23
I
installing
bezel, 19 hard drive blank, 23 hard drives, 24
introduction
Fortinet documentation, 4
K
keyboard, 20
M
monitor, 20 mouse, 20
P
power cables, 21
R
removing
hard drive blank, 23 hard drive from a drive carrier, 25 hard drives, 23 system from the rack, 14
round-hole racks, 8
S
sliding rail kit, 7 square-hole racks, 7 SSD hard drives, 23 system
turning on, 22
T
technical support, 3 turning on the system, 22
FortiManager-1000C™ Version 4.0 Rack and Hardware Install Guide 02-40000-112634-20091026 27