Conguring
Web-based Manager
Use the following procedure to connect to the web-based manager for the rst time.
Conguration changes made with the web-based manager are effective immediately without resetting the FortiBridge unit or interrupting service.
To connect to the web-based manager
1. Connect the management port of the FortiBridge unit to Ethernet port of the management computer.
Use a cross-over Ethernet cable to connect the devices directly. Use straight-through
Ethernet cables to connect the devices through a hub or switch.
2. Congure the management computer to be on the same subnet as the FortiBridge
management port interface.
To do this, change the IP address of the management computer to 192.168.1.2 and
the netmask to 255.255.255.0.
3. To access the FortiBridge web-based manager, in your browser, go to
http://192.168.1.99.
4. Type admin in the Name eld and click Login.
To congure Probes
Probes monitor the FortiGate unit by sending packets from the INT 2 interface through
the FortiGate unit to the EXT 2 interface. If probe packets are not received at the EXT 2
interface the FortiBridge unit detects a failure.
Congure probe settings to set actions on failure, add a dynamic IP pattern used by the
probe packets, and enter the serial number of the FortiGate unit. Actions on failure can
include failing open and sending an alert email, a syslog message, and an SNMP trap.
1. Go to Probe > Settings.
2. Enter the Probe IP address pattern (#.#.#.*).
3. Enable ping, HTTP, FTP, POP3, SMTP, and/or IMAP probes.
4. Set the Port Number for each protocol.
5. Change the Failure Threshold and probe Interval for each probe.
To set up Notications
1. Go to Probe > Notications.
2. Enter a Notication Message Tag.
3. Optionally, select the Syslog check box and enter the IP address, port and facility of
the Syslog server that receives FortiBridge syslog messages.
4. Optionally, select the Email check box and enter the SMTP server, email addresses,
SMTP user name, and password of the users to send the alert email.
5. Optionally, select the SNMP check box and enter the name, hosts, and traps of the
SNMP manager to send alerts to a community.
To congure the Management, Default Gateway, and Primary and Secondary DNS server
IP addresses
1. Go to System > Status > Management Port area and click Change.
Command Line Interface
To connect to the FortiBridge unit
1. Use a RJ-45 to DB-9 cable to connect the FortiBridge management port to the management computer serial port.
2. Start a terminal emulation program (such as HyperTerminal) on the management
computer. Use these settings: Baud Rate 9600, Data bits 8, Parity None, Stop bits 1,
Flow Control None.
3. At the login: prompt, type admin and press Enter twice.
(The login prompt is preceded by the server default host name.)
To congure the FortiBridge unit using the CLI
1. Change the management IP address.
cong system manageip
set ip <intf_ip>/<netmask_ip>
end
2. Congure the primary and secondary DNS server IP addresses.
cong system dns
set primary <dns-server_ip>
set secondary <dns-server_ip>
end
3. Congure the default gateway.
cong system route
edit 1
set gateway <gateway_ip>
end
4. Change the administrator password.
cong system admin
edit admin
set password <password>
end
Shutting down the FortiBridge unit
When powering off the FortiBridge unit, always shut down the unit using the following procedures before disconnecting the power supply. Not following this procedure can increase
the risk of damaging the FortiBridge ash disk.
To power off the FortiBridge unit
1. Go to System > Status.
2. In the Unit Operation area, click Shut Down.
3. Once the indicates the shut down procedure has completed, disconnect the
FortiBridge unit from the power source.
Visit these links for more information and documentation for your Fortinet product:
Technical Documentation - http://docs.fortinet.com Fortinet Knowledge Center - http://kb.fortinet.com
Technical Support - http://support.fortinet.com Training Services - http://campus.training.fortinet.com
QuickStart Guide
FortiBridge-2002
FortiBridge 2002
INT1
MGMT1
MODEM1
CONSOLE1
USB1
INT2
EXT1
EXT1
INT1
INT2
HA1
BYPASS1
FortiGate
EXT2
MODE1 RESET1
NORMAL1
PWR1
EXT2
MODEM2
CONSOLE2
USB2
AC Power 50 W, 100 - 240 VAC, 50 - 60Hz
Chassis 1U
Dimensions 44.0 cm x 30.1 cm x 4.44 cm
8 10/100/1000 Ingress/Egress ports
Network Interfaces
2 10/100/1000 Management ports
2 USB connections
2 Console
© Copyright 2010 Fortinet Incorporated. All rights reserved.
Products mentioned in this document are trademarks or registered trademarks
of their respective holders.
Regulatory Compliance
FCC Class A Part 15, UL/CB/CUL, C Tick, VCCI
28 May 2010
INT3
MGMT2
EXT3
INT3
FortiGate
INT4
EXT4
INT4
EXT3
HA2
BYPASS2
MODE2 RESET2
NORMAL2
PWR2
EXT4
01-410-124725-20100510
LED DescriptionPackage Contents
Interface Description
FortiBridge 2002
CONSOLE1
USB1
USB1
Console1
Ground
AC power
connection
Power cabl e x2
INT1 and
MGMT1
MODEM1
Modem1
Management1
DISCONNECT TWO POWER SUPPLY CORDS
Power button Power button
Strai ght-t hroug h
Ether net c able
EXT1 and
INT2
INT1
INT2
BEFORE SERVICING
EXT2
EXT1
INT1
FortiGate
INT2
EXT2
LEDs LEDs
Reset1
Mode1
EXT1
HA1
BYPASS1
MODE1 RESET1
NORMAL1
PWR1
EXT2
LEDs
DB9-R J45 S erial
cable
USB2
USB2
CONSOLE2
Console2
MODEM2
Modem2
Management2
Tools and Documenation
MGMT2
INT3 and
INT4
INT3
INT3
FortiGate
INT4
INT4
DISCONNECT TWO POWER SUPPLY CORDS
BEFORE SERVICING
QuickStar t Guide
FortiBridge 2002
CONSOLE1
USB1
Copyright 2010 Fortinet Inc orporated. Al l rights re served.
Trademarks
Products mentio ned in this document ar e trademark s.
EXT3 and
EXT3
EXT4
INT1
MGMT1
MODEM1
INT1
INT2
INT2
EXT4
EXT1
FortiGate
EXT2
EXT3
EXT4
EXT1
EXT2
HA1
BYPASS1
MODE1RESET1
NORMAL1
PWR1
Mode2
HA2
BYPASS2
NORMAL2
PWR2
LEDs
AC power
connection
MGMT2
MODEM2
CONSOLE2
USB2
INT3
INT4
Factory Defaults
Administrator user name admin
Administrator password (none)
NAT/Route mode
Management1 192.168.1.99
Management2 0.0.0.0
To reset the unit to the factory defaults, in the CLI type the command:
execute factoryreset
MODE2 RESET2
EXT3
INT3
FortiGate
INT4
EXT4
Reset2
FortiGate-3 0B
EXT3
HA2
BYPASS2
MODE2RESET2
NORMAL2
PWR2
EXT4
REGISTER
LED State Description
Power
Normal
HA
Bypass
INT and
EXT LEDs
INT,
EXT, and
MANAGEMENT
Ports
Green The unit is powered on.
Off The unit is powered off.
Green The unit is being used in Normal
mode.
Green The unit is being used in a HA cluster.
Off The unit is in stand-alone mode.
Green Bypass network activity at this inter-
face.
Off Normal status.
Green The correct cable is in use and the
connected equipment has power.
Green ashing Network data is being sent or re-
ceived.
Off No link established or the interface
has been turned off.
Link/Activity (left) Green Port has power and network connec-
tion.
Link/Activity (left) Green
ashing
Speed (right) indicator is
Network data is being sent or received.
Connected at 1000 Mbps.
Green
Speed (right) indicator is
Amber
Speed (right) indicator
is Off
The interface is connected at 100
Mbps.
The interface is connected at 10
Mbps.
Interface Type Speed Proto-
Description
col
Console1
and Console2
Modem1
and Modem2
USB1 and
USB2
Management1 and
Management2
INT1, INT2,
INT3, INT4,
EXT1,
EXT2,
EXT3,
EXT4
RJ-45 9600 bps
8/N/1
RS-232
serial
Connection to the management computer. Provides
access to the command line
interface (CLI).
RJ-11 Phone line for internal
modem.
USB USB Two optional connections to
a USB key for installation.
RJ-45 10/100/1000
Ethernet Two management ports.
Base-T
RJ-45 10/100/1000
Ethernet Ingress and Egress ports.
Base-T
Connecting
Connect the FortiBridge unit to the internal and external networks and the FortiGate unit. Normally, you would use straight-through ethernet cables to connect
the FortiBridge unit. However, for some connections you may need a crossover
ethernet cable (for example, for compatibility with network devices that do not
support Auto MDI/MDIX).
• Connect the FortiBridge INT 2 interface to the FortiGate unit internal interface.
• Connect the FortiBridge EXT 2 interface to the FortiGate unit external
interface.
• Connect the FortiBridge INT 1 interface to the internal network.
• Connect the FortiBridge EXT 1 interface to the external network.
• Turn on the FortiGate unit and any network equipment that was turned off.
• Connect the power cords at the back of the FortiBridge unit. Plug the other
end of the power cables into a grounded electrical outlet.
• The PWR and Bypass Mode LEDs turn on. After a short time, the FortiBridge unit switches to Normal mode. The Bypass LED turns off and the
Normal LED turns on.