ASSEMBLY INSTRUCTIONS for 4" - 12" SERIES 1355-x-DWB (ALSO 1369-10-C & 1369-12-C)
Standard restraint device for new or existing installations of Ductile Iron Pipe, C900 PVC Pipe Bell Joints, or C907 Pipe Fittings
Clamping Bolt
Assemble split (non-serrated) back-up ring onto
Assemble spigot pipe end to bell using
2. Assemble Series 1300-x-DWB or 1309 serrated the pipe behind the pipe bell. Make sure beveled side of ring faces the pipe bell and is snug against the bell transition. Evenly tighten the clamping bolts to the recommended torque as shown in Table 1. A torque wrench is highly recommended and required to ensure proper torque. The restraint clamping pads will not touch when installed on ductile iron pipe.
IMPORTANT
Note: Position the restraint and
back-up ring so the nuts for the connecting rod contact the flat side of the ears. The restraint will not function properly if installed incorrectly.
Insert all supplied connecting rods into the slots and position as
Do not over-tighten the connecting nuts.
The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443
Telephone: 260-563-3171 FAX: 800-826-3487 Overseas FAX: 260-563-0167 http://www.fordmeterbox.com
Table 1
Recommended
Clamping Bolt Torque
PVC DIP
4" and 6" 100 ft-lb 100 ft-lb
8" and 10" 150 ft-lb 150 ft-lb
12" 150 ft-lb 200 ft-lb