INTRODUCTION
Note: Read this Instruction Manual carefully and keep it handy for future reference.
3
LCD DISPLAY
PRODUCT DESCRIPTION
FRONT VIEW
LCD Display
3
3
3
3
4
4
5
5
5
6
6
7
7
7
INTRODUCTION ..................................................................................................................
PRODUCT DESCRIPTION ...................................................................................................
FRONT VIEW ..................................................................................................................
LCD DISPLAY .................................................................................................................
FUNCTION KEYS ............................................................................................................
FEATURES ...........................................................................................................................
INITIAL SET-UP
....................................................................................................................
OPERATION .........................................................................................................................
WEIGHING WITH BMI FUNCTIONS WITH MEMORY ...................................................
TO CLEAR MEMORY ......................................................................................................
RS232 OUTPUT
..............................................................................................................
PROBLEM-SOLVING ...........................................................................................................
CARE AND MAINTENANCE.................................................................................................
Obese
BMI indication Bar
Underweight
Height
Weight
BMI
Normal Overweight
FEATURES
1. Weight measurement
2. BMI calculation
3. Four-button user friendly operation
4. Easily understandable readings
5. 5 user memories for storage of personal information (no. of users memory in Eprom setting)
6. Fast Memory Recall Mode enables direct access to specic memory location
7. Memory Clear Mode enables erase of memorized contents
8. Auto-on function for weighing-only operation, simply step onto the scale
9. Auto-off function for power saving. Unit will turn off automatically when no key has been pressed for 10 seconds
10. With blue LCD backlight display
11. Low-battery indicator reminds user to change battery
12. Weight capacity: 200kg, 440lbs or 31st6lb
13. Weight graduation: 100g/0.2lb/0.2lb
14. Height range from 75.0cm up to 225.0cm (2’4” to 7’4”)
15. Operates with 4 pcs AAA alkaline battery
INITIAL SET-UP
1. Uses 4pcs AAA alkaline battery.
2. Insert battery into the battery compartment.
3. Replace battery when is displayed (Fig.1).
4. Select between kilogram, stone-pound and pound conversions with push-button at the bottom of the scale. (the default setting unit is kg)
5. Position the scale on a at and hard oor surface.
The scale must be initialized after each battery insertion or replacement. Press lightly on the scale platform to initialize the scale, the display shows then show moving zero and then turn off. The scale is ready for use after the scale turned off (Fig.2 & Fig.3).
OPERATION
Weighing Only Operation
1. Step onto the scale and stand still while the weight is computed.
2. The screen displays the weight (Fig.4).
3. The scale turns off automatically after use.
5
4
Fig.1
Fig.2
Fig.4
FUNCTION KEYS
Conrmation button for selection
CLEAR
Clear contents of the user memory in Recall mode
Change value of height Select memory in Memory mode & Recall mode Fast recall of memory location Clear contents of the user memory in Recall mode
&
3.1. If user steps off the scale before stable weight is obtained,
the scale will display 0.0lb/kg for 5 seconds, then the scale
will go to Off mode automatically, moving zero is shown.
3.2. If user steps off the scale after stable weight is obtained,
the stable weight is displayed for 5 seconds, the scale will
go to Off mode automatically, moving zero is shown.
3.3. If user is still on the scale over 20s, the scale will go to
Off mode directly without showing the moving zero.
Fig.3 (
moving zero
)
3. If the selected memory is occupied, the screen then displays the height for 3 seconds, then follow steps 4-5 in the section of Select Memory Location.
B. To Fast-Recall Settings from Memory
1. Press ▲or ▼ to select the memory location.
2. If the selected memory is free, no numbers will be displayed (Fig.10).
6
2. If the selected memory location is occupied, it will display
"
" on the left of the memory (Fig.6).
3. Press to store the settings to the desired memory location, then height setting value will display on LCD
(Fig.7), then press ▲ or ▼ key to adjust the height, press to conrm (Fig.8).
4. The moving zero will display on LCD when the height value
is confirmed, then “0.0kg” will be display on LCD.
5. Ste p onto the scale & stand still while the weight is locked,
BMI calculation value will display on LCD (Fig.9).
Fig.6
Fig.7
Fig.8
Fig.9
Weighing With BMI Functions With Memory
The scale features 5 personal memory settings. This allows 5 users to store and recall their own height.
A Select Memory Location
1. Press ▲ or ▼ to toggle between memory locations “1”, “2”,
“3” “4” “5”, then press to conrm the location (Fig.5).
Fig.5
Fig.10
Weight: 82.4KG
Weight: 82.4KG
Height: 181cm
BMI: 25.2
7
PROBLEM-SOLVING
1. Display Err0 Initialization error. Step off the scale. Press lightly on the scale platform to re-initialize the scale, the display shows and then turns off. The scale is ready for use again.
2. Display Err1 Instability error. Repeat measurement again, stand still while computation is in process.
3. Display Err2 Overload warning.
Remove the weight immediately, otherwise permanent damage to the scale will occur.
RS232 Output
1. Always is on after power up
2. The default setting of the baud rate is 9600,8,n,1.
3. Once the weight is locked, the weight value is transmitted out via rs232. Or At BMI mode, the weight value and BMI value is transmitted out via rs232.
To Clear Memory
1. Follow steps 1-3 in the section of To Fast-Recall Memory.
2. If the selected memory is occupied, press and hold Clear key will clear height memory value.
Weight Value RS232 Output Format BMI Value RS232 Output Format
CARE AND MAINTENANCE
1. Do not disassemble the product other than replacing the battery; it contains no user
serviceable parts. Damage to the unit may occur as a result of improper handling.
2. Remove battery when the unit is not used for a prolonged period of time.
3. Clean the unit after use with a lightly dampened cloth. Do not use solvents or
immerse the unit in water.
4. Avoid excessive impact or vibration to the unit, such as dropping the product onto
the oor.
Loading...