Food Warming Equipment R-AS-10 Operators Manual

CNTRL-PNL-AIRSCREEN FSR NO DOOR STKR OpsManual_RAS10 FSR Version
FSR Version
R-AS-10 MOBILE REFRIGERATED AIR SCREEN
INSTALLATION GUIDE & OPERATING INSTRUCTIONS
1
11
KEEP
10 TRAYS
in unit
For Best
Results and
temps, retain
10 trays in unit
at all times
Pre-chill cabinet with door closed
A
A
minimum of one (1) hour.
Load cabinet from the bottom to top, push trays to rear.
B
B
Load with only
LOAD FOOD TRAYS
UNLOAD
FOOD TRAYS
PLACE
TRAYS
Replace
with
empty
tray
PRE-CHILLED FOOD of 40°F (4.4°C) or colder.
For Best
place trays
all the way
to the back
2
2
Results
of unit.
C
C
D
D
After loading chilled product, close door to allow inside temperature to stabilize.
Unload cabinet from top to bottom.
UNIT CAN OPERA
FWE Mobile Foodservice Equipment • 7900 S. Route 31 • Crystal Lake, IL 60014
TE WITH DOOR OPEN FOR UP TO 90 MINUTES
(Conditional)
FWE MOBILE REFRIGERATED AIR SCREEN
AIR SCREEN CREATES A “WALL” OF COLD AIR!
Exclusive “Food Sentry”
Air Screen Controls offer the
ultimate performance and accurate
cabinet temperatures when
operating with the door opened,
maintaining a temperature of
45°F (7.2°C) or below for a
minimum of 45 minutes and
a maximum of 90 minutes (conditional).
CONGRATULATIONS . . .
..and thank you for purchasing an FWE Mobile Air Screen Refrigerator. Your unit has been designed and manufactured under rigid controls to assure you the most efficient service. It is a full time unit, and may be used continuously as a “standard” refrigerator (with the door closed) or as an “air screen” with the door open maintaining a 45°F (7.2°C) temperature or below for a minimum of 45 minutes and a maximum of 90 minutes (conditional) .
Please take a moment to read through this booklet of important information pertaining to your cabinet.
By following a routine of proper use and care described on the following pages, your Air Screen will last for many years.
IMPORTANT THINGS TO DO BEFORE USING AIR SCREEN:
• Properly uncrate your unit and check for any possible damage.
• Read this operating manual and instructions.
• Return your Warranty & Manufacturer Registration Card.Your Manufacturer Registration Card
R-AS-10
must be returned within 30 days after initial delivery to put warranty into effect.
• Review installation instructions and have your unit(s) properly installed.
• Make sure all operators understand the contents of this manual and operation.
-2-
FWE MOBILE REFRIGERATED AIR SCREEN
INTRODUCTION
TABLE OF CONTENTS
DELIVERY INSPECTION........................................................................... 4
ELECTRICAL.............................................................................................. 5
INSTALLATION............................................................................................ 6
PERFORMANCE........................................................................................ 7
INTENDED USE........................................................................................ 7
CABINET FEATURES.................................................................................. 7
ELECTRONIC CONTROLS........................................................................ 8
TRANSPORTING.......................................................................................10
OPEN DOOR OPERATION........................................................................10
GENERAL CLEANING AND MAINTENANCE...........................................11
SERVICE INFORMATION.......................................................................... 12
TROUBLESHOOTING GUIDE................................................................... 13
REPLACEMENT PARTS............................................................................ 16
WIRING DIAGRAM.................................................................................... 18
WARRANTY............................................................................................... 19
SERVICE RECORD................................................................................... 20
-3-
FWE MOBILE REFRIGERATED AIR SCREEN
BEFORE SETTING UP
DELIVERY INSPECTION
All FWE refrigerators are shipped in containers in to prevent damage. Upon delivery of your new Air Screen:
Inspect the shipping container for external damage. Any evidence of damage should be noted on the delivery receipt which should be then signed by the driver.
Uncrate the unit and check for external damage. Carriers will accept claims for concealed damage if notified within fifteen (15) days of delivery and shipping container is retained for inspection.
The FWE - Food Warming Equipment Company ­cannot assume responsibility for loss or damage suffered in transit. The carrier assumed full responsibility of delivery in good order when shipment was accepted. We are, however, prepared to assist you if filing a claim is necessary. Notices are posted on the outside of each carton regarding freight claims and damage to further familiarize you with this information, as shown here.
All units are factory tested for performance and certified free from defects when shipped. The utmost care has been taken in manufacturing, crating and final inspection at the factory and / or shipping point to assure against damage in transit.
Should there be noted damage upon uncrating, carefully check the crate for visible signs of the cause. Save all crating material and immediately file a claim of damage with the carrier. Under no conditions may a damaged unit be returned to FWE without an RGA -
Authorization Number.
Return Goods
If damage is discovered, call your dealer, trucking company & FWE ­Customer Service Department at 815-459-7500.
This merchandise has been thoroughly inspected and carefully packed
before leaving our plant. Responsibility for its safe delivery was assumed
by the carrier at the time of shipment. Claims for loss or damage to the
contents, should therefore, be made upon the carrier as follows:
CONCEALED LOSS OR DAMAGE
Concealed loss or damage means loss or damage that does not become apparent until the merchandise has been unpacked.The contents may be damaged in transit due to rough handling even
though the carton may not show external damage. When the
damage is discovered upon packing, make a written request for
inspection by the carrier’s agent within fifteen (15) days of the
delivery date. Then file a claim with the carrier since such damage
is the carrier’s responsibility. By following these instructions
carefully, we guarantee our full support of your claims to protect
you against loss from concealed damage.
VISIBLE LOSS OR DAMAGE
Any external evidence of loss or damage must be noted on the
freight bill or express receipt, and signed by the carrier’s agent.
Failure to adequately describe such external evidence of
loss or damage may result in the carrier refusing to honor a
damage claim. The form required to file such a claim will be
DO NOT RETURN DAMAGED MERCHANDISE
TO US. FILE YOUR CLAIM AS ABOVE.
In case of damage, it is your responsibility to save all carton(s)
and packaging materials for the carrier’s inspection.
IMPORTANT
supplied by the carrier.
- 4 -
FWE MOBILE REFRIGERATED AIR SCREEN
DELIVERY INSPECTIONS & ELECTRICAL REQUIREMENTS
PACKAGING:
Your Air Screen Refrigerator is shipped from the factory on a wooden pallet and packaged in a durable cardboard container. The carton is attached to the wooden skid with the use of large staples. These should first be removed to avoid scratching the unit when lifting off the crate. Remove the wooden pallet and strapping material, and the unit should be rolled off the skid. Avoid laying the unit on its front, side or back for removal of the pallet.
NOTE: FWE does not recommend laying the unit down on its front, side or back. However, if you must, please be certain to allow the unit to remain in an upright position afterwards for 48 hours before plugging the unit in or attempting to place the unit in to service, to assure that the compressor oils and refrigerant may settle.
FWE’S POLICY ON D
There are two types of damaged merchandise: VISIBLE DAMAGE AND CONCEALED DAMAGE.
A. CRATE HAS VISIBLE DAMAGE:
1. The product / crate being received is visibly damaged.
2. The receiver should
3. Receiver should
is being "refused due to damage".
B. CONCEALED DAMAGE:
1. Merchandise is damaged and could not be externally detected. Your receiving operation should inspect for this type of damage.
2.
Save all packing material
3. Contact FWE Customer Service 815-459-7500 and alert them to the situation.
4. Receiver must call the carrier to schedule an inspection of the damaged merchandise within
AMAGED GOODS:
refuse the damaged merchandise.
sign the bill of lading indicating which merchandise
.
15 days
.
ELECTRICAL
A. Check SERIAL PLATE to be sure the unit is installed on the proper NEMA plug 5-20P (on standard unit)
electrical supply.
B. WARNING: This unit is provided with a three-pronged grounding plug. Be sure that the unit is plugged
into a properly grounded outlet to avoid the possibility of electrical shock.
CORD & PLUG:
Your Air Screen Refrigerator is supplied with a cord & plug attached. It is shipped coiled at the bottom of the cabinet, secured by a nylon strip. For your safety and protection, all units supplied with a cord and plug include a special three-prong grounding plug on the service cord. Select only a dedicated electrical outlet with grounding plug for power source. NOTE: Do not under any circumstances, cut or remove the round grounding prong from the plug, or use an extension cord.
PO
WER SUPPLY:
The supply voltage should be checked prior to connection to be certain that proper voltage for the cabinet wiring is available (refer to the serial tag to determine correct unit voltage). Make connections in accordance with local electrical codes. Use qualified electricians. USE OF A SEPARATE, DEDICATED 20 AMP CIRCUIT IS REQUIRED. Size wiring to handle indicated load and provide necessary overcurrent protector in circuit (see amperage requirements on the unit’s serial tag).
WIRING DIA
Refer to the wiring diagram for any service work performed on the unit. Should you require service, please contact FWE and provide the model and serial number of the unit involved.
GRAM:
-5-
FWE MOBILE REFRIGERATED AIR SCREEN
INSTALLATION & PROPER LOCATION
INSTALLATION
LOCATION:
Selecting a proper location for your Air Screen Refrigerator is very important.
AL
WAYS:
NEVER:
Install to assure that unit is level.
Install to assure that unit is away from extreme heat.
Install to assure that unit is away from a steamer.
Install to assure that unit is NOT placed near or under
a ventilation duct or hood, (this will disturb the airflow of the Air Screen and will hamper the performance of the unit).
Install to assure that unit is 6'' minimum distance from back of unit
to wall or obstruction (ie; a wall).
Install to assure that the door(s) may open a minimum of 90 degrees.
CLEARANCE:
It is important for the proper operation and longevity of your FWE Air Screen that it have adequate provisions for air supply to the compressor. Allow approximately 6'' - 12'' between the back grill of the unit and the wall for proper air flow.
Never install equipment in
an area of standing water
Never install near or under a
ventilation hood or duct return
Never install equipment in an
area not conductive to safe and proper operator use.
INST
ALLATION STEPS:
A. The outside carton has already been removed and inspected for damage. Remove all packing and
strapping material from the exterior and interior of the unit. (Note: Packing material should be saved should there be any damage to unit.)
B. Remove the FWE Air Screen from the shipping skid. This is done by tilting the unit and rolling it
off the skid.
D. Tray slides have tabs formed into the side of the support. Simply put the tab into the square hole in the
side of the cabinet and push down to seat. The supports can be installed in a horizontal plane or can be mounted in a slightly sloped orientation to cause the product to slide forward on the sheet pans.
E. The LED digital temperature display is powered up when the unit is plugged in, it registers temperature
in Fahrenheit degrees. The unit can be set up to show temperatures in Celsius degrees.
ON/OFF Switch for Instructions.)
Do not lay the cabinet down.
(See Page 9,
-6-
Loading...
+ 14 hidden pages