Food Warming Equipment BT Installation Manual

OPERATING
INSTRUCTIONS
ORIGINAL INSTRUCTIONS
TOP MOUNT HEAT SYSTEMS
UHST SERIES
TST SERIES
PST SERIES
BT SERIES
Caution: Read the instructions before using the machine.
FWE TOP MOUNT HEATED HOLDING CABINETS
WARNING SYMBOLS
WARNING SYMBOLS*
To indicate hazards arising from dangerous voltages
To identify the terminals which, when connected together, bring the various parts of an equipment or of a system to the same potential.
To identify the terminal which is intended for connection to an external conductor for protection against electric shock in case of a fault, or the terminal of a protec­tive earth (ground) electrode
To indicate that the marked item can be hot and should not be touched without taking care
To indicate the “ON” condition for a part of equipment
To indicate the “OFF” condition for a part of equipment
To indicate the stand-by or preparatory state for a part of equipment
To indicate maximum ll level
To indicate minimum water level
2 FWE TOP MOUNT HEAT SYSTEM
*SYMBOLS MAY VARY FROM UNIT TO UNIT
FWE TOP MOUNT HEATED HOLDING CABINETS
INSTALLATION
SEE SHIPPING LABEL FOR CASTER SIZE
CASTER DESCRIPTION
2” GREY RUBBER CASTER,SWIVEL W/BRK CASTER 2” RIGID CASTER 3” RIGID CASTER 3.5” RIGID HEAVY DUTY CASTER 4X2” EZ ROLL RIGID POLYBLUE CASTER 5” RIGID HEAVY DUTY CASTER 5” RIGID SUPER DUTY CASTER 5” SWIVEL BRAKE RB GRS FIT Poly CASTER 5” RIGID EZ ROLL POLY CASTER 5” SWIVEL BRAKE EZ ROLL POLY CASTER 6” RIGID HEAVY DUTY CASTER 6” RIGID SUPER DUTY CASTER 6” SWIVEL BRAKE EZ ROLL POLY CASTER 6” RIGID EZ ROLL POLY CASTER 8” PNEUMATIC RIGID CASTER 8” RIGID HEAVY DUTY CASTER 8” RIGID SUPER DUTY CASTER 8” SWIVEL BRAKE EZ ROLL POLY CASTER 8” RIGID EZ ROLL POLY
MAX WEIGHT
34Kg 68Kg 68Kg 113Kg 272Kg 124Kg 226Kg 340Kg 362Kg 362Kg 158Kg 272Kg 453Kg 453Kg 113Kg 226Kg 272Kg 544Kg 544Kg
Improper use of this machine can result in injury and/or death.
A schedule should be put in place for inspections and preventative maintenance.
New users should be properly trained in the use of this equipment.
No special protective equipment is required to operate this unit.
Unplug unit before servicing.
IN THE EVENT OF ACCIDENT OR
BREAKDOWN - UNPLUG UNIT.
FOR SERVICE INQUIRIES PLEASE CALL
FWE SERVICE - 800-222-4393
3
FWE TOP MOUNT HEATED HOLDING CABINETS
WARNING AND CLEANING CARE
CLEANING
Keep your cabinet clean by simply wiping the interior and exterior, as needed, with a damp cloth or sponge and a mild soapy solution.
NEVER USE ABRASIVES, ACIDS, OR STRONG CLEANERS.
Do not flood or allow electrical parts to become wet. The interior tray slide assemblies and humidifier pans are removable for easy cleaning.
A stainless steel cleaner/polish is recommended for the exterior to maintain a “like-new” appearance.
DO NOT USE WAX OR STRONG CLEANERS ON DOOR GASKETS OR VINYL TRIM.
4 FWE TOP MOUNT HEAT SYSTEM
FWE TOP MOUNT HEATED HOLDING CABINETS
REQUIREMENTS
ELECTRICAL REQUIREMENTS AND GROUNDING
For U.S. and Canada Models:
The amperage of your cabinet is stamped on the name plate serial tag attached to the unit. FWE models are equipped with a grounded cord plug for your protection against possible shock hazards. Be sure to plug only into a properly grounded wall receptacle. If you have any questions with regard to adequate wiring or grounding in your building, a qualified electrician should be contacted before using your cabinet.
For International Models:
May be shipped with no cord or plug.
Contact qualified service personnel for cord and plug installation.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE GROUNDING PRONG FROM THE CORD PLUG.
WARNING: ONLY QUALIFIED SERVICE PERSONNEL SHOULD REMOVE, REPAIR OR REPLACE ELECTRICAL COMPONENTS OR WIRING.
BE SURE THAT MODEL IS UNPLUGGED FROM ELECTRICAL SOURCE BEFORE REMOVING CONTROL PANEL, MOVING, CLEANING, OR SERVICING UNIT.
INTENDED USE AND REQUIREMENTS
This unit is to be used for warming only.
Unit must be installed level.
5
Loading...
+ 11 hidden pages