fomex HD150, HD600, HD200, HD400, HD900 User Manual

...
HD SERIES
HD150 / 200 / 400 / 600 / 900 / 1000 / 1200
User Manual
Before using
1. Be sure to use the lighting only after understanding manual.
3. Do not move it nor give impact while the power is on (Lamp filament can become disconnected)
4. Be sure to use the grounded socket as a power.
5. When using accessories like reflector or snoot, install or separate it after turning off halogen lamp and cooling the heat enough.
6. There could be risk of fie if you use softbox made from combustible material, so use softbox has over certain grade or is made out of incombustible material like glass fiber.
7. Be careful against electric shock when using in a damp place.
8. Keep out of children’s reach.
Warning
The lamp must be changed if it has become damaged or thermally deformed.
• Shields, lenses, or screens must be changed if they have become visibly damaged
(cracks or deep scratches) to such extent that their effectiveness is impaired,
Symbol for minimum distance from lighted objects e.g. Symbol for indoor use
Symbol required according to WEEE
HD SERIES
2
HD SERIES
Procedure
3
Before using
Name of each part
Name and function of control panel
Operating way
Specifications
Method of managing and keeping
Countermeasure on breakdown
page
2
4
5
6
7
8
9
HD SERIES
Name of each part
4
① Protection cap
Modeling(Halogen) lamp
Flash tube(Xenon tube)
Accessory disassembling and
assembling locking knob
Slave sensor
Lighting knob
Stand stud joint fastening bolt
Stand stud joint part
Prop fastening bolt
Knob for fastening.
Control panel
HD SERIES
Name and function of panel
5
Sound ON/OFF button : It makes signal sound on flash electrification or electric
discharge.
Test PUSH button : It’s pressed on flash electric discharge or flash test.
Flash power control volume : It controls power of flash(strobe).
Modeling lamp control volume : It controls the brightness of modeling(halogen) lamp.
Synchro ‘X’ : It’s a terminal that connects synchro cord.
Slave sensor : It has function to slave the light of other lighting.
Slave ON/OFF button : It’s a function to select whether to slave with other lighting.
(ON : Slave, OFF : Unslave)
Overheat signaling lamp : It turns on when inside circuit of lighting is overheated, and
on this case, turn off the power and cool the lighting before using.
Power switch : It has function of turning off and on the lighting.
AC input : Connecting part of power cord.
Operation
6
1. When released from the factory, halogen control volume is in off position.
2. Fit the modeling lamp into the lighting.
3. After checking if modeling lamp control volume(MODEL) of control panel and output control volume are at minimum position and if power switch is OFF, connect the power cord to input socket.
4. Connect synchro cord to synchro socket.
5. Turn on the power button and power indicator lamp should come on
6. Control the brightness of modeling lamp with modeling lamp control volume.
7. Control the power with power control volume.
8. If you want to tune this with other lighting, turn on the slave button.
9. If you change the power from high to low, ready lamp might flicker. If so, discharge by pressing ready button before using.
10. Sound lamp turns on when you press the sound button. Sound is generated according to the change of power. If power is changed to lower power, it will start beeping. If you press the ready button at this time, the sound stops.
Way of checking whether flash is charged when not using sound function.
During charging : Modeling lamp is OFF Completion of charging : Modeling lamp is ON
HD SERIES
HD SERIES
Specifications
7
Model
Item
HD150 HD200 HD400 HD600 HD900 HD1000 HD1200
Maximum Output(W/s)
150 200 400 600 900 1000 1200
Input Voltage
AC 110/220V 50/60Hz
Charging Time(sec)
0.1~1.0 0.1~1.2 0.2~1.5 0.2~1.5 0.3~1.8 0.3~2.0 0.3~2.5
Power Control Range
F2.8~F22 (6f-stops)
F2.83~F22
3
(6f-stops)
F45~F32
5
(6f-stops)
F5.6~F45 (6f-stops)
F5.6
8
~F45
8
(6f-stops)
F8~F64
(6f-stops)
F82~F64
2
(6f-stops)
Color Temperature
5500˚K(±150˚K)
Ready Charge
LED Light/Buzzer(ALARM ON), Modeling Lamp Blinking(ALARM OFF)
Modeling Lamp
GX6.35 Base
Modeling Control Analog Dial Volume
Triggering Methode Synchro Sensor, Ready Button, Svnchro Cord
Triggering Voltage
DC 8V
Over Temp’ Warning
O.T(Red LED)Blinking, Buzzer Warning Sound
Size(W×L×H)mm
235×140×170 280×140×170 350×140×170
Weight
2.3kg/5.1lbs 2.5kg/5.5lbs 2.7kg/5.9lbs 3.7kg/8.1lbs 3.9kg/8.6lbs
Cooling Form
DC Cooling Fan(Ball Bearing Type)
Slave(Infrared Sensor)
ON/OFF
Sound
ON/OFF
HD SERIES
Directions for replacing parts
8
1. Replacing the modeling lamp (BASE: GX-6.35)
- After cooling the lamp enough, maneuver it left and right to separate it from the socket.
- Maneuver the new lamp left and right to install it onto the socket.
- Be careful not to let any finger print or dust stain the lamp, and clean the lamp with soft cloth or tissue lightly dampened with alcohol after replacing the lamp.
2. Replacing the fuse
- Separate the power cord from the AC socket
- Eject the fuse holder using a straight (-) screwdriver
- Remove the existing fuse and install the spare fuse, which is also inside the fuse holder.
- Be sure not to let dust stain the discharge tube and modeling lamp with replacing the fuse.
- If dust or other materials get stuck to the discharge tube or lamp, it can shorten the life of the lamp and deteriorate the color temperature, thus clean any impurities with a soft cloth.
Reference :
When input voltage is lower than rated voltage, there can be cases where it’s not charged fully for maximum output. So in this case, check the input voltage.
HD SERIES
Countermeasure on breakdown
9
Status Expected cause Point of checking and action
Slave is
impossible.
Slave button is turned OFF. Check if slave button is turned ON.
Slave sensor is out of the light
of flash.
After turning the lighting by 180° so as for turning sensor to be shown, and than operate it again.
Too strong light is on slave sensor.
Block direct ray of light or bright light from slave sensor.
Synchro Cord
doesn’t become tuned.
Due to dust or other material on
synchro jack, it causes contact’s
defective.
After checking synchro jack, remove
other material.
Synchro cord has defective contacts
and is disconnected.
Replace synchro cord.
(Check if it can radiate by pressing ready button.)
There’s no
reaction at all.
Power supply is blocked.
• Check if power cord is well connected.
• Check if the contact of socket is loose.
• Check if fuse is disconnected.
Others Contact our company or its seller.