Follett U155N Series, U155NR400A, U155NR400W, U155NR800A, U155NR800W Installation, Operation And Service Manual

Page 1
Order parts online www.follettice.com
U155N Series
Ice and Water Dispensers
Installation, Operation and Service Manual
Manual load units Automatic load units
with one icemaker
Automatic load units
with two icemakers
Following installation, please forward this manual
801 Church Lane • Easton, PA 18040, USA Toll free (800) 523-9361 • (610) 252-7301 Fax (610) 250-0696 • www.follettice.com
208599R01
Page 2
Contents
Welcome to Follett. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Before you begin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Field wiring diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installing dispenser in counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installing remote icemaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
User Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Cleaning Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Disassembly for cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Disassembly for service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Dispenser troubleshooting guide . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Replacement parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Dispenser exterior . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Dispense assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Hopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Auger motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Electrical components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Page 3
Welcome to Follett
Follett ice and water dispensers enjoy a well-deserved reputation for excellent performance, long-term reliability and outstanding after-the-sale support. To ensure that this dispenser delivers that same degree of service, we ask that you take a moment to review this manual before beginning the installation of the dispenser. Should you have any questions or require technical help at any point, please call our technical service group toll free at (800) 523-9361 or (610) 252-7301.
Before you begin
• After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If damage is found, notify the shipper immediately and contact Follett Corporation so that we can help in the filing of a claim, if necessary.
• Check your paperwork to determine which model you have. Follett model numbers are designed to provide information about the type and capacity of Follett ice dispensing equipment. Following is an explanation of the different model numbers in the U155 series.
U155NR400AR
Ice dispense chute location – R = right side, L = left side
Condenser type – A = air-cooled, W = water-cooled
Remote icemaker(s) capacity and refrigerant – 400 = 400 lbs (181kg)/day, R404A 800 = 800 lbs (363kg)/day, R404A absence of = manual fill unit
N = ice and water only, no beverage rail or valves
Approximate storage capacity in lbs
Dispenser configuration – U = undercounter
Important cautions
• Storage area of dispenser contains mechanical, moving parts. Keep hands and arms clear of this area at all times. If access to this area is required, power to unit must be disconnected first.
• Follett manual load dispensers can accommodate most cube/cubelet ices up to 1" square, or Follett compressed nugget ice. Crushed, flake, bagged, nugget or congealed ice cannot be used. Use of these ices can jam dispenser and void warranty. Separate any “waffle-like” sections of cubes before adding to dispenser. For ice compatibility questions, please call Follett customer service toll free at (800) 523-9361 or (610) 252-7301.
• Follett recommends use of an activated carbon filter for units equipped with icemakers.
• Ice is slippery. Maintain counters and floors around dispenser in a clean and ice-free condition.
• Ice is food. Follow recommended cleaning instructions to maintain cleanliness of delivered ice.
Specifications
Electrical
Each icemaker and dispenser requires separate circuit with electrical disconnect within 10 feet (6m). Equipment ground required. Standard electrical - 115V, 60Hz, 1 phase. Max. fuse dispenser – 15 amps; each
icemaker – 20 amps
Model Icemaker Dispenser number amperage amperage
U155N - - 2.4 amps U155NR400A/W 11.0 amps 2.4 amps U155NR800A/W 11.0 amps ea (2) 2.4 amps
3
Page 4
Plumbing
Dispenser 3/4" PVC slip joint for hopper drain
3/4" PVC pipe nipple for beverage drain pan 3/8" ID red line tubing for water in
304mm run) slope on drain line run.
Icemaker Refer to Icemaker Installation Manual packed with icemaker
1/4" FPT water in 1/2" MPT drain 3/8" FPT condenser inlet (water-cooled condenser only) 1/2" FPT condenser drain (water-cooled condenser only) Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units.
Note: Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per
Clearance and access information
• 51" (1296mm) above counter
• 12" (305mm) on side opposite tower, below counter
• Counter front or rear panel must be removable for service access to both sides of dispenser and icemaker(s), if any
• Below counter access to drain clean-out required on utility side of dispenser
Side view - right hand dispenser
(side opposite dispense tower)
27.375"
(696mm)
12"
(305mm)
ice transport tube entrance
3.5"
(89mm)
26"
(661mm)
plain water connection
air break:
do not connect to drain system
26"
(661mm)
3/4" PVC slip joint drain
5.25"
(134mm)
two remote icemakers models U155NR800A/W
17" (432mm)
Front view
one remote icemaker models U155NR400A/W
18.875" (480mm)
6" min (153mm)
12" min (305mm)
plain water
electric conn.
and drain clean-out
Automatic load units with 1 icemaker
Automatic load units with 2 icemakers
31.25
(794mm)
Manual load units
12"
(305mm)
21.75"
"
(553mm)
49.75" (1264mm)
28" (712mm)
4
Page 5
Electrical hookup information
Model
U155N
U155NR400A/W
U155NR800A/W
Electrical Connection
• Hard-wiring of dispenser required.
• Dispenser power – hard wiring required.
• Bin signal – cord and plug supplied.
• Icemaker – cord and plug supplied on power and bin signal.
• Dispenser power – hard wiring required.
Circuit(s) required
115V, 60Hz, 1 phase Max. fuse dispenser – 15 amps.
115V, 60Hz, 1 phase (2) circuits required
• Dispenser – 15 amps max. fuse size.
• Icemaker – 20 amps max. fuse size.
115V, 60Hz, 1 phase (3) circuits required
• Dispenser – 15 amps max. fuse size.
• Bin signal – cord and plug supplied.
• Icemaker – cord and plug supplied on power and bin signal.
• (2) icemakers – 20 amps max. fuse size each.
Note: equipment must be wired according to local and NEC codes.
Attention – Should local codes require a hard-wired connection and/or shielded wiring,
!
eliminate the cord(s) and plug(s) and follow the appropriate field wiring diagram on the following page.
See icemaker Installation and Operation manual for recommended junction box preparation of
hard-wired remote icemaker(s).
5
Page 6
Field wiring diagrams
Manual load units
IMPORTANT
Field wiring diagram is intended to aid electrician or technician in understanding how equipment works. All field wiring must be installed in accordance with NEC and local electrical codes.
LEGEND
Wirenut field connections Equipment
X
ground
BL - black
W - white
GRN - green
Automatic load units
Electric power source
(115 volts)
GND
GRN
BL W
X
Standard electrical - 115V, 1 Ph, 60Hz, max. fuse size 15 amps
U155 dispenser
15 amp fused disconnect
Left junction box
GND GRN
W
BL
Right junction box
BL
Y
NOT USED
R
Field wiring diagram is intended to aid electrician or technician in understanding how equipment works. All field wiring must be installed in accordance with NEC and local electrical codes.
IMPORTANT
Electric power source
(115 volts)
BL W
GND
X
GRN
15 amp fused disconnect
Standard electrical - 115V, 1 Ph, 60Hz, max. fuse size 15 amps
U155 dispenser
Left junction box
W
GND GRN
(115 volts) (24 volts)
On all models with remote icemaker(s), the black wire on the icemaker control board’s(s’) LINE VAC terminal must be moved to the 24V terminal.
Right junction box
BL
LEGEND
Wirenut field connections
Equipment
X
ground
GND - ground BL - black
W - white GRN - green B - blue R - red
Y - yellow
B
Y
R
Icemaker #1
Lower junction box
BL
W
(24 volts)
Icemaker #2 (optional)
Lower junction box
W
BL
(24 volts)
(115 volts)
Electric power source
GND
BL W
GRN
X
15 amp fused disconnect
BL W
GND
X
GRN
15 amp fused disconnect
Upper junction box
W
BL
GRN
X
GND
Upper junction box
GND
BL
GRN
X
W
6
Page 7
Installation
Installing U155 dispenser in counter
All U155 dispensers must be installed level in both directions and supported from
!
below with 6" - 9" (153 – 229mm) adjustable leg accessory provided, or channels installed on site. DO NOT hang dispenser on flange.
1. Check that dispenser location meets all requirements in this manual and cut counter as shown.
2. Block up area below counter cut-out to support dispenser when lowered into place.
3. For automatic load dispensers, disconnect ice transport tube from bracket in storage area of dispenser.
(Since this tube must be reinstalled in bracket after dispenser is dropped into counter, note how tube is held
by bracket tabs before disconnecting.)
4. Carefully lower dispenser into counter until it rests on support blocks.
5. Adjust height from below until dispenser flange rests flush with counter.
6. Apply a bead approximately 1/4" (6mm) in diameter of NSF listed silicone sealant (Dow-Corning RTV-732
or equivalent) around perimeter of dispenser where it meets counter and smooth sealant to a 1/8" (4mm)
radius.
7. Install a hard drain line, maintaining at least a 1/4" per foot (20mm per 1m) slope, and insulate line to
prevent condensation.
PVC pipe is suggested. Care must be taken in sweating any metal drain pipe used. Excessive heat applied while sweating metal pipe may melt plastic fitting on
!
dispenser.
8. Make electrical connections in accordance with applicable wiring diagrams provided, as well as NEC and local codes. Provide disconnects within 10 ft (3m) of dispenser and icemaker for servicing.
Counter cut-out
30.375"
(772mm)
+.125"
- .125"
+3 mm
- 3 mm
26.25"
+ .125"
- .125"
(667mm)
+3 mm
- 3 mm
Front of counter
7
Page 8
Installing remote icemaker (automatic load units only)
Correct installation of remote icemaker(s) is critical to proper performance of
!
icemaker and dispenser.
Check to make sure bin signal on icemaker control board is switched to 24 volt connection.
Refer to installation manual packed with icemaker for important details on ice transport tube run, ventilation requirements and other installation requirements.
Failure to comply with instructions will void warranty.
1. Position icemaker in desired location.
2. Push one end of ice transport tube(s) through hole(s) provided in side of dispenser.
3. Route tube into ice tube bracket inside dispenser and engage bracket tabs in holes located in end of ice
transport tube(s). (See drawings below.)
4. Proceed with ice transport tube installation from dispenser to icemaker in compliance with instructions
contained in icemaker installation manual packed with icemaker.
Ice tube retainer bracket
thermostat
ice tube
thermostat
Front view
tabs in ice tube retainer bracket engage holes in ice tube and hold tube in place
1"(25mm)
ice tube
Side view
8
Page 9
To start-up and operate dispenser
1. Follow detailed cleaning instructions in service manual before operating dispenser.
2. For manual load units, remove front drain pan or rear lid and fill storage area with compatible ice.
Follett manual load dispensers can accommodate most cube/cubelet ices up to
!
1" square and Follett compressed nugget ice. Crushed, flake, nugget, bagged or congealed ice cannot be used. Use of these ices can jam dispenser and void warranty. Separate any “waffle-like” sections of cubes before adding to dispenser. For questions about ice compatibility, call Follett’s customer service group toll free at (800) 523-9361 or (610) 252-7301.
3. Turn power switch located on control box to ON position.
4. For automatic fill units, follow detailed instructions in icemaker installation section of installation manual,
then turn icemaker (bin signal) switch(es) located on control box to ON position and begin to make ice.
5. When dispenser has at least 6" (153mm) of ice in storage area, press “PUSH FOR ICE” lever or button to
ensure that dispenser is operating properly.
Note: If additional start-up information is needed, call Follett Corporation at (800) 523-9361.
User information
How the dispenser works
Follett’s U155N series ice and water dispensers are available in manual load configurations (using ice from another source) or automatic load configurations, fed from one or two Follett 400 lb (181kg)/day remote icemakers.
In all models, ice is stored below the counter in the dispenser storage area. When the dispense lever or button is pushed, the dispense motor is activated. This causes the wheel assembly in the storage area to turn, moving ice to the vertical auger assembly, which carries ice up to the dispense chute where it drops by gravity into the container.
In automatic load units, ice is manufactured in either one or two Follett remote icemakers. These icemakers may be located up to 20 ft (6m) away from the dispenser. As water freezes to the inside walls of the icemaker evaporator, a rotating stainless steel auger removes ice and carries it to the top of the evaporator assembly where it is compressed and extruded through an outlet port. The extruded ice is then pushed through the tube to the storage compartment of the dispenser. A level fill circuit maximizes fill in the storage area by rotating the wheel at intervals until the bin is completely filled. When the bin is filled, a bin stat shuts the icemaker off to avoid overfilling of the bin. The icemaker will restart after 20 minutes if the bin is calling for ice.
Cleaning
Warning: Always disconnect power before cleaning dispenser.
!
Using solutions below, clean and sanitize storage area and beverage lines before starting up unit and on a routine
basis as noted below.
Solution A: Prepare a cleaning solution (200 ppm of available chlorine content) of Ecolab Mikro-chlor
Cleaner or equal chlorinated detergent. Cleaning solution temperature must be at
75˚ – 125˚F (24˚ to 52˚C).
Solution B: Prepare a sanitizing solution (50 ppm of available chlorine content) of Ecolab Mikro-chlor
Cleaner or equal chlorinated detergent. Sanitizing solution temperature must be at
75˚ – 125˚F (24˚ to 52˚C).
9
Page 10
Cleaning bin before use
1. Wipe storage area with Solution A.
2. Rinse thoroughly with clear, potable water.
3. Wipe with Solution B to sanitize.
Periodic cleaning of dispenser
Recommended daily cleaning of drain pan
DO NOT run plastic parts (drain pan, dispense chute cover, dispense wheel)
!
through a dishwasher.
1. Remove all debris from drain pan.
2. Pour 1 gallon (4L) hot water into drain pan to keep drain lines clear.
Recommended weekly cleaning
1. Remove drain pan and grille and wash with Solution A. Rinse thoroughly.
2. Pour a solution of one cup (8oz/237ml) household bleach mixed with one gallon (3.8L) hot water into drain
pan to help prevent algae growth in drain lines.
Recommended quarterly cleaning (every 3 months)
On push-button units, remove dispense switch from dispense chute cover
!
before cleaning chute cover.
1. Turn power switch to OFF position and remove top from dispenser.
2. Remove ice from storage area.
3. Remove dispense chute cover, chute, auger motor assembly, auger and auger tube (page 11).
4. Remove drain pan, grille, dispense wheel and cover plate (page 12).
5. Clean all components and bin storage area with Solution A, rinse thoroughly with clear water and sanitize
with Solution B.
6. Remove clean-out plug from drain line tee on side opposite dispense tower and let bath drain.
7. Use a bottle brush to clean coil with Solution A, then rinse and sanitize with Solution B.
8. Reinstall clean-out plug in drain line tee.
9. Pour potable water into bath to submerge coil.
Putting unit back in service after quarterly cleaning
1. Reassemble components.
2. For manual load units, fill unit with an approved ice (see caution statement on page 3).
3. For automatic load units with R400A/W (R404A refrigerant) icemakers, turn bin signal switch(es) and
dispenser power switch to ON position and allow storage area to fill.
4. Push dispense button or lever to test that dispenser is functioning properly.
Quarterly cleaning of icemaker system
Units equipped with icemakers require cleaning of icemaker system at least every three months, and more often if local water conditions dictate. Failure to clean icemaker system will result in decreased performance and potential damage to icemaker. Refer to Icemaker Operation and Service Manual.
10
Page 11
Disassembly instructions for periodic cleaning
Dispense chute cover removal
1. Remove top cover.
2. Push chute cover up vertically to slip off
holding tab.
3. After clearing tab, pull chute cover forward
to remove.
Dispense mechanism assembly removal
1. Remove top cover.
2. Remove chute cover (see above).
3. Remove auger motor assembly (see
above).
4. Remove quick release pins from the ice chutes
and gates, then unplug wires from solenoids.
5. Lift dispense mechanism up and off auger tube.
drain pan assembly
Auger and auger tube removal
(Fig. 3)
1. Remove auger motor and dispense mechanism
assembly (see above).
2. Pull auger upward to clear auger tube.
3. Lift auger tube upward to clear dispenser top.
4. Slide tube and bearing plate through auger
tube gasket.
Fig. 1
Fig. 2
Front View
right-hand unit
top cover
WATER ICE
Dispense assembly, top View
right-hand unit
chute cover
dispense chute
Dispense wheel removal
1. Remove drain pan assembly and bin access cover.
2. Remove center thumbnut and threaded rod on
dispense wheel assembly and lift wheel out front access opening.
Auger motor assembly removal
1. Remove top cover.
2. Remove one thumbnut on rear of motor bracket.
3. Lift motor bracket up and unplug electric
quick disconnects.
4. Remove motor assembly.
11
quick release pin
solenoid
gate
ice chute
Page 12
2
Fig. 3
auger motor (side view)
Front view
auger
auger bearing plate
rotating agitator
baffle plate
wheel motor mounting plate
auger tube
dispense wheel
stationary agitator
wheel motor
plain water hook-up
chilled water coil
Disassembly instructions for service requirements only – NOT required for any cleaning procedure
Dispense wheel motor removal (Fig. 3)
1. Remove drain pan, bin access cover and dispense wheel.
2. Remove stainless steel baffle plate under dispense wheel.
3. Remove two screws holding wheel motor bracket on bin.
4. Lift plate and motor up.
5. Unplug electric quick disconnects from motor.
6. Lift motor and mounting plate out front access opening.
Service
12
Page 13
Wiring diagrams
AUGER MOTOR
CLOCKWISE ROTATION
Left hand unit
DISPENSE RELAY
Orn
L2
Wht
Wht
Blk
M1
Red
Red
Pur
R1
Orn
Wht
Blk
PL2-2
Blu
Blu
PL2-3
PL2-1
Pur
47
PL2-2
WHEEL
CLOCKWISE ROTATION
Red
Red
R2
AUTOFILL
Wht
Blk
Pur
Wht
M2
PL3-3
PL3-2
7
1
PL3-3
Blu
Blu
R2AUTOFILL
Orn
PL3-1
96
Wht
LEGEND:
PIN and SOCKET CONNECTION
TERMINAL STRIP CONNECTION
ROTATION
AUGER MOTOR
WATER SOLENOID
WATER SWITCH
Right hand unit
COUNTERCLOCKWISE
Blk
NO
C
Orn
R1
DISPENSE RELAY
Red Red
Pur
Pur
Orn
Blk
Gry
Blk
M1
PL2-1
7
4
NO
C
NO
C
NO
C
Blu
Blu
PL2-3
SWITCH
REAR LID
SWITCH
DRAINPAN
SWITCH
TOP LID
M2
WHEEL
ROTATION
Red Blk
COUNTERCLOCKWISE
Red
PL3-2
R2
7
1
Pur
AUTOFILL
Blu
Blu
PL3-1
R2
9
6
AUTOFILL
Orn
AUTOFILL OPTION
Ye l
Ye l
Brn
R1
9
DISPENSE RELAY
6
Red
DISPENSE SOLENOID
DISPENSE RELAY
24 Volts
DISPENSE SWITCH
Ye l
Brn
Red
A
R1
B
NO
C
Ye l
115 Volts
T1
Red
Blk
R2
AUTOFILL RELAY
Brn
1
2
AutoFill Timer
Blu
3
Red
A
B
Ye l
3
5 SEC ON
18 MIN OFF
2
BIN
T-S TAT
Ye l
ICEMAKER #1
BIN SIGNAL (24V)
Blu
IM_#1
IM_#2
SWITCH NO. 1
ICEMAKER #2
BIN SIGNAL (24V)
24V JUNCTION BOX
Red
SWITCH NO. 2
AUTOFILL OPTION
POWER
BLK
L1
13
Page 14
Before calling for service
1. Check that there is ice in dispenser and that congealed cubes are not causing a jam.
2. Check that circuit breaker and switches are in ON position.
3. Check that drain pan, rear lid and top are on securely. If ajar, dispenser will not operate. When the top is off, auger does not operate, even though the solenoids do.
4. Check that all drains are clear.
Note: For units equipped with Follett compressed nugget icemaker, see Icemaker Operation and Service
Manual for service and troubleshooting information.
Dispenser troubleshooting guide
Symptom
Ice does not dispense.
• Auger motor does not run
• Wheel motor does not run
Ice does not dispense.
• Auger motor runs
• Wheel motor runs
• Gate does not open
Ice does not dispense.
• Auger motor does not run
• Wheel motor runs
Ice does not dispense.
• Auger motor runs
• Wheel motor does not run
No ice in dispenser.
Possible cause
1. Power switch faulty or in OFF position; loose connection.
2. Faulty dispense switch.
3. Faulty transformer.
4. Drain pan ajar.
5. Faulty drain pan safety switch.
1. Loose electrical connection.
2. Linkage problem between solenoid and gate.
3. Faulty solenoid.
1. Loose electrical connection.
2. Faulty auger motor.
3. Faulty run capacitor.
1. Loose electrical connection.
2. Faulty wheel motor.
3. Faulty run capacitor.
1. Power switch in OFF position or faulty.
2. Bin signal switches in OFF position or faulty.
3. Faulty bin thermostat.
4. Faulty transformer.
5. Icemaker related problem.
6. Faulty run capacitor.
Solution
1. Turn power switch to ON position; check connections.
2. Replace switch.
3. Replace transformer.
4. Check pan and reseat.
5. Replace switch.
1. Check connections.
2. Check linkage.
3. Replace solenoid.
1. Check connections.
2. Check auger motor.
3. Check run capacitor.
1. Check connections.
2. Check wheel motor.
3. Check capacitor.
1. Check switch and replace if necessary.
2. Check switch and replace if necessary.
3. Replace bin thermostat.
4. Replace transformer.
5. Refer to icemaker Operation and Service Manual for diagnosing.
6. Check for power and bin signal on icemaker PC board.
If problems persist after following this basic troubleshooting guide, call Follett’s technical
service department toll free at (800) 523-9361 or (610) 252-7301.
14
Page 15
Dispenser exterior
Top view
unit with right hand (RH) tower
Replacement parts
Front view
right hand (RH) tower
(push-button dispensing)
6
8
2
5
18
10
WATER ICE
14
3
1
4
Reference # Description Part #
1 Label, “Follett” 502438 2 Top cover (includes label) 502606
3 Drain pan 502446 4 Grille, drain pan 502450 5 Cover, electrical components 502593
6 Lid, rear access 502594
Not shown Cover, ice storage (under drain pan) 502453 7 Label, ice, dispense cover, push-button 502623 Not shown Label, ice, dispense cover, lever 502622 8 Label, water, dispense cover, push-button 502617 Not shown Label, water, dispense cover, lever 502616
9 Cover, dispense chute, push-button operation (includes button and label), ice 502440 Not shown Cover, dispense chute, lever operation, ice 502439 10 Cover, dispense chute, push-button operation (includes button and label), water 502620 Not shown Cover, dispense chute, lever operation, water 502619 11 Chute, focus, clear plastic 502459 Not shown Push pin, clear chute 502618 Not shown Lever, dispense for water and ice 501953
12 Switch, push-button operation, for ice (includes label) 502441 13 Splash shield, right hand unit 502612 Not shown Splash shield, left hand unit 502613 14 Thumbscrew, splash shield, 10-32 x 1/2 501100 Not shown Switch, dispense lever for ice and water 502505 15 Panel, access, right hand and left hand units 502585 16 Panel, front, dispense mechanism, ice, right hand unit 502588 Not shown Panel, front, dispense mechanism, ice, left hand unit 502589 17 Panel, front, side, back wrap, water dispense, right hand unit 502634 Not shown Panel, front, side, back wrap, water dispense, left hand unit 502592 Not shown Panel, rear, motor support, right hand unit 502586 Not shown Panel, rear, motor support, left hand unit 502587 Not shown Clip, Tinnerman, 10-32 502621 Not shown Screw, 10-32 x 1/2 502287 Not shown Legs, 6" (153mm) adjustable to 9" (229mm), set of 4 502454 18 Switch, water dispense, push-button operation (includes label) 502648 Not shown Plug 2 lead, male 502333 Not shown Plug 2 lead, female 502334
3
13
17
7
9
12
11
15
16
15
Page 16
Dispense assembly
Dispense assembly side view
(RH unit shown)
9
1
9
6
7
5
3
Top view
2
11
4
10
Reference # Description Part #
1 Gate, dispense 502455 2 Linkage pin, gate/solenoid 502456 3 Pin, quick release, 5.53" (141mm), dispense gate 502102 4 Solenoid (includes linkage pin) 00126607 5 Dispense mechanism assembly, right hand unit 502458 Not shown Dispense mechanism assembly, left hand unit 502496 6 Spring, dispense mechanism (1 per side) 501950 7 Chute, ice 502457 8 Wrap, dispense mechanism 502607 9 Bushing, Ni liners 501249 10 Screw, 8-32 x 5/16 502625 11 Pin, spring 502624
8
16
Page 17
2
Hopper
5
1
7
Side view
9
3
8
11
2
6
10
4
left-hand unit shown
Reference # Description Part #
1 Auger, LH unit (black, stamped with “1”) 502491 Not shown Auger, RH unit (gray, stamped with “2”) 502492 2 Plate, auger bearing 501696 Not shown Tube, auger, right hand unit 502487 Not shown Tube, auger, left hand unit 502488 3 Wheel, dispense (includes stud and rotating agitator) 501681 4 Baffle (under dispense wheel) 501684 Not shown Drive bar (under dispense wheel) 501682 5 Motor, vertical auger 502476 6 Motor, wheel 502560 Not shown Seal, wheel motor 501333 Not shown Spacer, wheel motor 501768
Not shown Capacitor, wheel motor 501782
7 Agitator, rotating, 21" (534mm) long 502484 8 Plate, wheel motor mounting 502615 9 Agitator, stationery 502490 Not shown Bracket, ice tube, double tube 502497 Not shown Ice transport tube (sold by the foot) 500366 Not shown Ice transport tube, 10 ft 502522 Not shown Ice transport tube, 20 ft 502523 Not shown Insulation, transport tube (sold by the foot) 501176 10 Coil, plain water 502461 11 Tubing, water (sold by the foot) 502356 Not shown Cover, blank ice entry 502674 Not shown Gasket, ice entry 502672 Not shown Plate, ice entry, 2 holes 502673
17
Page 18
Auger motor
Side view
7
6
6
9
1
8
5
Top view
3
10
4
2
11
Reference # Description Part #
Auger motor/drive assembly, vertical (includes all items below) 502493
1 Motor, vertical auger (includes gearbox and capacitor) 502476
2 Chain, auger drive #35, 40p 502477
3 Sprocket 35#, 22T 5/8 bore 502478
4 Sprocket 35#, 12T 5/8 bore 502479
5 Drive shaft 502480
6 Bearing, auger, upper and lower 501314
7 Cover and bearing, chain drive (includes 501314) 502481
8 Capacitor, 25mf, 270V 501550
9 Key, Woodruff 502482
10 Washers, thrust (4) 501765
11 Mounting plate, auger motor (includes 501314) 502483
18
Page 19
Electrical components
14
12,16,19
6
11
13
1
5
2
Reference # Description Part #
1 Transformer, 24V 502058
2 Relay, dispense 501826
3 Relay, auto fill 501826
4 Timer, auto fill (automatic fill units) 502471
5 Strip, terminal 502472
6 Tube, water dispense, stainless steel 502356
7 Bracket, water solenoid 502611
8 Fitting, outlet, 1/8 MPT x 3/8, compression 502562
9 Valve, solenoid, water 502243
10 Fitting, inlet, plastic, 1/4 barb 502637
11 Tubing, water (sold by the foot) 502356
12 Switch, safety 502511
13 Switches (power and icemaker) 502209
14 Bracket, switch, mounting (power and icemaker) 502638
15 Chute, focus, clear plastic 502459 Not shown Switch, safety, rear cover assembly, left hand unit 502498 16 Switch, safety, rear cover assembly, right hand unit 502499 Not shown Switch, safety, drain pan assembly, left hand unit 502500 17 Switch, safety, drain pan assembly, right hand unit 502501 Not shown Switch, dispense, lever 502505 18 Bracket, safety switch, drain pan, right hand unit 502609 Not shown Bracket, safety switch, drain pan, left hand unit 502610 19 Bracket, safety switch, rear 502608 Not shown Thermostat, bin level 500514
4 3 7 6 15
12
9
12,17,18
15
7
8
9
10
11
19
Page 20
801 Church Lane • Easton, PA 18040, USA Toll free (800) 523-9361 • (610) 252-7301 Fax (610) 250-0696 • www.follettice.com
208599R01
02/06