The Ice Manager diverter valve system automatically delivers ice
from ONE Follett Horizon Elite™ ice machine to TWO separate
dispensers or bins. The system includes a control panel, diverter
valve, and components to connect two ice storage units chosen.
RIDE® remote ice delivery equipment
- deliver ice automatically through a tube to where you need it,
instead of manually transporting
- reduce handling to provide more sanitary ice and prevent
safety issues for employees and customers
- install ice machine and diverter valve up to 75' (22.8 m) away
from the bin
- create a more aesthetically appealing dining area with less heat
and noise around your customers
Flexibility with a wide choice of bins and dispensers
- Follett ice storage bins, Ice Transport Systems (ITS), and
Ice•DevIce
- Follett Vision™ low-profile ice and beverage dispensers and
Symphony Plus™ 110CM ice and water dispensers
- countertop ice and beverage dispensers manufactured by
others (see approved list on page 2)
- other ice storage containers (contact factory)
Ecient use of equipment
- fill two bins or dispensers with only one ice machine
- reduce the number of ice machines in your operation, or
eliminate manual filling
- keep one machine running more eciently instead of two
machines that may idle frequently
- service and maintain only one machine instead of two
Factory-arranged installation and start-up
- turn-key system installation with factory-trained installers
- full operational demonstration to end-user
Warranty
- 3 years parts and labor on all components
™
ice storage and dispensing systems
Job
Item
801 Church Lane | Easton, PA 18040, USA
1.800.523.9361 | 1.610.252.7301 | follettice.com
Page 2
Configuring the Ice Manager diverter valve system
1. Select Horizon Elite ice machine model
Using the model configuration table below, determine the Horizon Elite ice machine that will best suit your needs. For more specifications on
Horizon Elite ice machine models, see form# 7030, 7035, 8180 and 3311. Existing Horizon series ice machines may be retrofitted to integrate
with the Ice Manager diverter valve system. Based on model# and serial#, determine the retrofit kit to order using the table below.
Horizon Elite 1010, 1410, 1810 and 2110 Series Ice Machine Model Number Configurations
for use with Ice Manager Diverter Valve System
IcemakerVoltageSeriesCondenser
HC Horizon
Chewblet
C 208-230/60/1 (icemaking head)
Self-contained only.
D 115/60/1 (icemaking head)
Self-contained and remote.
If remote unit, high side is208-230/60/1.
F 115/60/1 (icemaking head)
Remote only. High side is
208-230/60/3.
A Air-cooled, self-contained
1010
W Water-cooled, self-contained
1410
R Air-cooled, remote condensing unit
1810
N Air-cooled, no condensing unit for
2110
connection to parallel rack system
2. Select two dispensers or bins to be filled
Choose two approved units for ice storage. If exact model is not
known, note type of unit. Lane 1 is the primary lane and should
be assigned to bin or dispenser with highest demand.
Lane 1: ___________________________________
Lane 2: ___________________________________
If desired unit is not listed below, contact factory.
Follett Ice Transport and Storage
New Follett ice storage bin or transport system model.
See form# 8590 for models. When ordering bin, specify bin top to be cut for
IceManager diverter valve system. If ice machine will be top mounted on bin,
see Step 3.
Existing Follett ice storage bin or transport system model.
Requires replacement top cut for Ice Manager diverter valve system.
Seeform# 4025 for item numbers. If ice machine will be top mounted on bin,
seeStep3.
Follett Symphony Plus Ice and Water Dispenser 110CM
Follett Vision Ice and Beverage Dispensers
New Follett Vision 155 and 300 ice and beverage dispenser model. VU155N
models are available via Special Quote Request (SQR).
See form# 4025 for models. Order Vision with VUIMDVKIT to be configured for
Ice Manager diverter valve system.
Existing Vision 155 serial# must be greater than B50001.
Existing Vision 300 serial# must be greater than B50005.
Ice and Beverage Dispensers
Coca-Cola Freestyle 9000
Coca-Cola Freestyle 7000
Coca-Cola Freestyle 9100
Cornelius ED/DF150 SeriesLancer FS-22NServend MD250
Cornelius ED/DF175 SeriesLancer FS-30NServend MDH302
Cornelius ED/DF200 SeriesLancer FS-44NServend MDH302
Cornelius ED/DF250 SeriesLancer Sensation 30"/44" Servend MDH402
Cornelius ED/DF300 SeriesLancer TouchpointServend SV175
Cornelius IDC215Lancer BevarietyServend SV200
Cornelius IDC255/Pro/Fast GatePepsi Spire 3.0/5.0/4.1
Cornelius Flavor Fusion/Overload Servend FRP-250
1
Consult with dispenser provider to be sure the dispenser is ready to dispense nugget ice.
2
Consult with Coca-Cola and Follett to qualify application prior to ordering.
Requires DVF30 top kit ordered separately from Follett and top adapterkit 46412 and ice kit
46430, which must be ordered from Coca-Cola.
Requires DVF26 top kit ordered separately from Follett.
Approved only for Pepsi Spire 3.0, 5.0 and 4.1 designed for top mount ice machines. Requires
DVP22 top kit for 3.0 and DVP30 top kit for 5.0 and 4.1, ordered separately from Follett. For
manual fill versions of Pepsi Spire 3.0, 5.0 and 4.1, contact factory.
HCD1010/1410 and HCF1010/1410/211000997098
HCC1010 and HCC1410 01085455
Machine StandItem #
HCC1010 and HCC141001085463
HCD1010/1410/1810/2110 and HCF1010/1410/1810/211000997080
Follett Bin - Top Mount
New bin, see form# 8590 for models.
When ordering bin, specify bin top to be cut for Ice Manager diverter valve
system and ice machine
Existing bin, see form# 4025 for bin top listing.
Requires replacement top cut for Ice Manager diverter valve system and
icemachine when ordering
Other
Specify what the Horizon series ice machine will be mounted on.
1
See drawings on page 3 for min. bin width and required clearances.
1
1
.
1
.
Ice Manager diverter valve system
Page 3
Configuring the Ice Manager diverter valve system (Continued)
4. Evaluate site for location of equipment
Lane 1 and Lane 2 dispensers or bins
• Refer to dispenser or bin specifications for required clearances
• See drawings below for required clearances for Ice Manager
diverter valve system
Follett Horizon Elite ice machine
• 10' (3 m) maximum distance from Horizon Elite ice machine to
diverter valve
• See spec sheets 7030, 7035, 8180 and 3311 for utility
requirements anddimensions
Diverter valve
• 8' (2.4 m) maximum distance from diverter valve module to
electricoutlet
• 75' (22.8 m) maximum distance from diverter valve to Lane 1 and
Lane 2 dispensers or bins
• Drain required, 15' (4.6 m) drain tube provided
Control panel
• 30' (9.2 m) max. distance from control panel to diverter valve
5. Determine length of ice transport tubes
Lane 1: (approx. length): ____________________
Lane 2: (approx. length): ____________________
Use the following guidelines to determine length of the
icetransport tube run from the diverter valve to each bin
ordispenser.
• Length of ice transport tube from diverter valve module to each
dispenser or bin can be specified in 5' (1.5 m) increments from
10' - 75' (3.0 m - 22.8 m) ¹
• Maximum vertical rise of ice transport tube – 10' (3 m)
• Horizontal run should be pitched so that melt water drains back
todiverter valve module. Run must have 1⁄4" per foot pitch.
• No dips or traps in the tube run
¹ Lengths to include any bends and turns needed to connect components.
6. Site plan drawings
Installation may be performed by an authorized installer
contracted by Follett. Contact factory for details.
Required clearances for Ice Manager diverter valve system
Diverter valve
Front View
6.00" (15.24 cm)
clearance
mounting
bracket
12.00" (30.5 cm)
clearance
6.00" (15.24 cm)
clearance
Sensor distribution unit
(bins and ice and beverage dispensers only)
Front ViewSide View
12.00" (30.5 cm)
clearance
bin / dispenser topbin / dispenser top
Insulated transport tube
(RIDE applications)
Front ViewSide View
6.00" (15.24 cm)
clearance
Side View
LANE 2
mounting
bracket
Top mount on a bin (minimum bin width)
Front View
Y
X
LANE 1
4.12"
sensor
distribution
unit
min.
2.00"
(5.08 cm)
clearance
Note: For 30.00" (76.2 cm) Follett bin, sensor distribution
unit may be placed behind ice machine.
(10.46 cm)
Horizon Elite ice machine
min.
1. 00" (2.54 cm)
clearance
min.
0.50" (1.27 cm)
clearance
bin top
3.00" (7.62 cm) dia. hole required
to run tubing through walls
Form# 3265
3
Page 4
Specification
Control panel
W1 Width of control panel12.00" (30.5 cm)
D1 Depth of control panel3.75" (9.52)
H1 Height of control panel12.50" (31.8 cm)
Connections30' (9.2 m) cable to diverter valve
Diverter valve with mounting bracket
W2 Width of diverter valve13.62" (34.6 cm)
D2 Depth of diverter valve17.50" ( 44.4 cm)
H2 Height of diverter valve10.38" (26.4 cm)
Connections8' (2.4 m) cord and plug,
15' (4.6 m) drain tubing
C1 Drain3/8" NPT barbed drain fitting
Lane 1insulated ice transport tube and
sensor cable
and connection kit for ice storage
unitused
Lane 2insulated ice transport tube and
sensor cable to diverter valve
and connection kit for ice storage
unitused
Electrical
115 V/60/1
1.5 amps, 8' (2.4 m) cord,
NEMA 5-15 plug
Sensor distribution unit
W3 Width of distribution sensor4.12" (10.46 cm)
D3 Depth of distribution sensor7.75" (19.68 cm)
H3 Height of distribution sensor3.50" (8.89 cm)
to diverter valve ‡,
†
†
‡
,
Dimensional drawing
Control panel
W1
H1
Diverter valve with
mounting bracket
D1
D2
H2
W2
General information
Approximate ship weight of
IceManager with 50' (15.2 m) of
icetransport tube
Operating temperature40 - 120 F (4 - 49 C), relative
‡ Lengths to be specified by customer.
† Follett Vision ships with connection kit factory-installed (item# VUIMDVKIT).
NOTE: For indoor use only
SHORT FORM SPECIFICATION: Ice Manager diverter valve system to be
model IMDV-2. System to direct ice delivery to two bins or dispensers
automatically, utilizing sonic sensors to control level of ice.
Ice machine to be Follett Horizon Elite model __________________.
Lane 1 to fill ____________________ ,
Lane 2 to fill ____________________ .
(ice and beverage dispenser, bin or Vision)
Horizon Elite ice machine to be mounted on __________________
(bin, wall mount bracket or machine stand)
System to include _____ feet of insulated ice transport tube for Lane 1,
and _____ feet of insulated ice transport tube for Lane 2
(75' (22.8 m) max. length for each lane)
Horizon Elite ice machine and Ice Manager NSF, UL, and cUL listed.
System to be installed by Follett.
1
Lengths to be confirmed on-site prior to shipment. Lengths to include any bends and
turns needed to connect components.
120 lb (55 kg)
humidity not to exceed 55%
1
.
C1
16.00"
(40.6 cm)
Sensor distribution unit
H3
D3
W3
HORIZON, HORIZON ELITE, ICE•DEVICE, ICE MANAGER, SYMPHONY PLUS and VISION are trademarks of
Follett LLC.
CHEWBLET, FOLLETT and RIDE are registered trademarks of Follett LLC, registered in the US.
Follett reserves the right to change specifications at any time without obligation. Certifications may vary
depending on country of origin.