ID650
Ice Dispensing System
Installation, Operation and Service Manual
Click for Cleaning and Sanitizing Instructions
Following installation, please forward this manual
totheappropriate operations person.
801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com
Order parts online:
www.follettice.com
00925818R02

Contents
Welcome to Follett. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Ambient Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Electrical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Drain Plumbing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Clearance and Accessibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Ice Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Detailed Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Cleaning and Sanitizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Exterior Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Interior Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Recommended Semi-Annual Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Front Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Dispense Auger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Upper Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Lower Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Base and Drain Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Electrical System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2 ID650 Ice Dispensing System

Welcome to Follett
Icemaker Model Number Configurations
Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability, and outstanding
after-the-sale support. To ensure that this product delivers that same degree of service, we ask that you take a
moment to review this manual before beginning the installation. Should you have any questions or require technical
help at any point, please call our technical service group at (877) 612-5086 or +1 (610) 252-7301.
Before You Begin
After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If
damage is found, immediately notify the shipper and contact Follett Corporation so that we can help in the ling of
a claim, if necessary.
Check your paperwork to verify that you received the correct dispenser. Follett conguration numbers are designed
to provide information about the type of dispenser you are receiving. The following is an explanation of the model
number.
650ID
Icemaker Series
Ice Dispensing Bin
650 650 lb (295 kg)
maximum bin capacity
Important Safety Information
Please read and adhere to the following safety information while installing, using, or servicing your Follett ID650
Ice Dispensing System.
1. Always disconnect power before cleaning or servicing the dispenser.
2. The storage area of the dispenser contains mechanical, moving parts. Keep hands and arms clear of this
area unless performing maintenance.
3. The dispenser can accommodate Horizon Chewblet® ice only. Cube, crushed, ake, other nugget,
bagged or fused ice cannot be used. Use of these ice types can jam or damage the dispenser and void
the warranty. For questions about ice compatibility, call Follett's technical service toll free at
(877)612-5086or +1(610) 252-7301.
4. Ice is slippery. Maintain counters and oors around dispenser in a clean and ice-free condition.
5. Ice is food. Follow the recommended cleaning instructions to maintain cleanliness of delivered ice.
ID650 Ice Dispensing System 3

Specications
Dimensions
ID650
Width 36.2" (919.5 mm)
Depth 46.9" (1191.3 mm)
Height 77.75" (1974.9 mm)
Unit Shipping Weight 540 lb (245 kg)
Ambient Information
NOTICE!
The ID650 is recommended for indoor use only.
Maximum Minimum
Air Temperature 100 F (38 C) 40 F (4 C)
Electrical
§ The ID650 dispenser and its accompanying icemaker require separate electrical circuits, and the equipment
must be grounded.
§ 220 V, 60 Hz, 1 phase, 5A max, 15A circuit, NEMA 6-15 receptacle
§ 7 ft. ( 2.13 m) power cord with plug provided
Drain Plumbing
§ Two (2) 3/4" PVC socket ttings (one for bin drain, one for drain pan) run to oor drain.
§ DO NOT reduce sizing.
§ Drains must be hard-piped and insulated.
§ Maintain at least a 1/4" per foot (1 cm per 31 cm) slope on the drain line runs.
§ DO NOT tee drains together or into icemaker drain line.
Clearance and Accessibility
§ 12" (305 mm) minimum to right of dispenser for service.
§ 4" (102 mm) minimum behind the dispenser for drain connection.
§ A door opening no less than 34.625" (879.5 mm) wide and an unobstructed path to the installation site.
Ice Type
§ The dispenser can accommodate Horizon Chewblet® ice only. Cube, crushed, ake, other nugget, bagged
or fused ice cannot be used. Use of these ice types can jam or damage the dispenser and void the
warranty. For questions about ice compatibility, call Follett's technical service toll free at (877) 612-5086 or
+1(610)252-7301.
4 ID650 Ice Dispensing System

Specications
Detailed Drawing
(continued)
46.9" (1191 mm)
30.75" (781 mm)
4" (102 mm)
drain
clearance
(2) 3/4"
PVC fittings
for drains
10.25
"
(260 mm)
77.75
(1975 mm)
"
36.2" (919 mm)
29.75" (756 mm)
9" (229 mm)
43
"
(1092 mm)
12" (305 mm)
service
clearance
SIDE VIEW
FRONT VIEW
NEMA 6-15 plug with 7 ft. (2.13 m) cord
ID650 Ice Dispensing System 5