-30 C Undercounter Plasma Freezer
Order parts online
www.follettice.com
Installation, Operation and Service Manual
Serial numbers C45184 and above
Following installation, please forward this manual
to the appropriate operations person.
801 Church Lane • Easton, PA 18040, USA
Toll free (800) 523-9361 • (610) 252-7301
Fax (610) 250-0696 • www.follettice.com
00193482R00
Welcome to Follett
Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and
outstanding after-the-sale support. To ensure that this product delivers that same degree of service, we ask that
you take a moment to review this manual before beginning the installation. Should you have any questions or
require technical help at any point, please call our technical service group at (800) 523-9361 or (610) 252-7301.
Before you begin
After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If
damage is found, notify the shipper immediately and contact Follett Corporation so that we can help in the ling
of a claim, if necessary.
Speci cations
Series speci cations
FZR5-PL
34" height for freestanding use or installation below standard 36" (915mm) high counter
2 drawers - up to 40 (350ml) plasma cartons
Maximum drawer load - 35 lbs (16kg) each.
Electrical speci cations
115V, 60Hz, 1 phase
Full load amps: 8.0
Minimum circuit ampacity: 15 amp
Maximum size of branch circuit overcurrent device: 15 amp
Refrigeration speci cations
Refrigerant – R404A
Charge size – 10 oz
Maximum design pressures:
High side – 383psi
Low side – 175psi
Installation speci cations
Ambient temperature must not exceed 30 C (86 F).
The front louvered panel must be kept free of any cabinet trim or obstructions to ensure proper ventilation of the
refrigeration system.
Important cautions
• Equipment must be wired according to local and NEC codes.
• Always disconnect power before servicing freezer.
3
Installation
Fig. 1
Installing legs – required
1. Remove legs from plastic bag packed inside freezer.
2. Tip freezer back and screw legs in all the way to stop (they will extend
1/8" below base of freezer).
3. Adjust legs as needed to level freezer in both directions. To access
legs, remove the lower front panel. Turn legs clockwise to extend legs.
Temperature surveillance module
Follett’s all-in-one temperature alarm and chart recorder module (manufactured for Follett by Dickson) may be
included with your FZR5-PL. Please refer to the Dickson instructions packed with this module for set-up and
operation instructions.
Follett’s monitoring bottle and temperature probe has already been installed in the Follett FZR5-PL. Simply
connect the loose end of the probe wire on the back of the unit to the surveillance module to complete the install.
A box of sixty (60) -50 to +50 7-day charts have also been included with this module. Replacement charts and
pens can be ordered from Follett by calling Technical Service at 800-523-9361:
Item # 00162099 — Box of sixty (60), -50 to +50, 7-day replacement charts
Item # 00162081 — Box of six (6) replacement red pens
Charts with different temperature scales are also available. Contact Dickson at www.dicksondata.com
4
Reversing the door swing – optional
NOTICE
When reinstalling latch and hinge screws, 242 blue Loctite* MUST be
applied to screws. Torque screws to 25 in-lbs.
1. Remove screws and latch from refrigerator cabinet (Fig. 2.1).
2. Use at screwdriver to carefully remove (do not scratch) hinge
covers (Fig. 3.1).
Fig. 2
3. Support door and remove screws attaching hinge to refrigerator
cabinet (Fig. 3.2).
4. Cover hinge screw holes with screw hole plugs removed from
opposite side.
5. Reverse door. Apply 242 blue Loctite to hinge screws and reinstall
torqued to 25 in-lbs.
6. Reinstall latch on opposite side.
7. Remove screws and handle from door (Fig. 4.1).
8. Rotate handle (Fig. 4.2).
9. Apply 242 blue Loctite to latch screws and reinstall torqued to 25 in-lbs.
1
2
Fig. 3
Fig. 4
*Loctite is a registered trademark of Henkel Corporation in the United States and other countries.
5