Self-contained and remote. If remote
unit, high side is 208-230/60/1.
E 230/50/1 (icemaking head)
Self-contained only.
F 115/60/1 (icemaking head)
Remote only. High side is
208-230/60/3.
400 up to
454 lbs
(206kg)
1000 up to
1036 lbs
(471kg)
1400 up to
1450 lbs
(658kg)
1650 up to
1580 lbs
(717kg)
CondenserSeriesVoltageIcemaker
A Air-cooled, self-contained
W Water-cooled, self-contained
R Air-cooled, remote condensing unit
N Air-cooled, no condensing unit for
connection to parallel rack system
V Vision™
H Harmony™
B Ice storage bin
J Drop-in
M Ice Manager
diverter valve
system
ConfigurationApplication
S RIDE™
(RIDE remote
ice delivery
equipment)
T Top-mount
2
self-contained VISION • RIDE Technology
Page 3
Read and complete the following 8 installation steps
Unpack
1
Dispenser preparation
3
Ice transport tube
5
Site preparation
2
Louvered docking assembly
4
External connection
6
Internal connection
7
Front cover
8
VISION • RIDE Technology self-contained
3
Page 4
Carefully unpack and inspect the contents of your Follett ice machine.
1/2"
1/2"
➊➋
➌➍
➎➏
Unpack
1
1. 1
Unpack ice machine
4
self-contained VISION • RIDE Technology
Page 5
Site preparation
Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet (2m) of ice
machine in accordance with local and national codes. Outdoor installation is
not recommended and will void warranty.
• The drain line from the ice machine must have at least 1/4" per foot pitch (6,4mm/0,3m)
VISION • RIDE Technology self-contained
‡
5
Page 6
Prepare the dispenser.
Dispenser preparation
3
2.1
3.1
Bin Signal Installation
➏
➎
➏
24"
(610 mm)
➌
➍
➋
Ground
➊
➌
• Mount the electrical box to the side of the Vision dispenser ➊ to establish a ground connection.
Note: If a 4 x 4 box is mounted to a non-grounded surface, connect ground wire at an
appropriate ground.
• Connect the bin signal plug on the electrical box to the bin signal cord on the bin
• Insert 24" (609,6mm) of the long bin signal cable ➌ into the hole in the back of the louvered
docking station
• After sliding the ice machine module into the louvered docking station, disconnect the shuttle
plug
• Complete normal installation procedure for the ice machine using the installation manual that
shipped with the ice machine.
• Connect the bin signal plug
6
from the ice machine control box.
➎
and secure in place with strain relief provided.
➍
into the ice machine control box.
➏
self-contained VISION • RIDE Technology
➋
Page 7
VISION • RIDE Technology self-contained
7
Page 8
Louvered docking assembly
Install the louvered docking assembly.
WARNING
• Docking station must be secured in accordance with these instructions to ensure ice machine
stability.
• Ventilation openings in the louvered docking station should be clear of obstruction
Wall bracket accessoryMachine stand accessory
4
• Mount louvered docking assembly to wall
bracket accessory
4.1
DOCKING STATION: Horizon 1000 & 1400 water- and air-cooled models
• Position and screw louvered docking assembly to the bottom of counter inside of access panel/
• The mounting surface for the louvered docking assembly must be solid.
• There must be no lip or edge that would hinder the ice machine from sliding in or out of the
INTAKE AND EXHAUST GRILLE PLACEMENT: Horizon 1000 & 1400 air-cooled models only
• Position the intake grille cut out in the access panel/door
• Left edge of cutout should be 1.75" (45mm) from the left side of the ice machine
• Bottom edge of cutout should be 1.875" (48mm) from the bottom of the ice machine
• Position supplied exhaust grille at least 18" (458mm) away from intake grille ➎.
• If not using supplied grille, air circulation requirements below must be met:
Undercounter installation requirements Horizon 1000 & 1400 series
(See detail drawing on page 9)
door 1.75" (45mm) from the front edge of the cross brace
Do not mount directly onto runners or channels.
louvered docking station
(See detail drawing on page 9)
Note: Ice machine must be aligned with cut out and inside of access panel to provide a tight
seal and prevent recirculation of hot exhaust air.
Where possible, install exhaust grille to the rear or side of the base cabinet.
1000 series: 150 sq. in (967 sq cm) intake air, 150 sq. in (967 sq. cm) exhaust air
1400 series: 175 sq. in (1129 sq. cm) intake air, 175 sq. in (1129 sq. cm) exhaust air
➋
• Mount louvered docking assembly to
machine stand accessory
➊
➌
➍
8
self-contained VISION • RIDE Technology
Page 9
Undercounter installation detail – Horizon 1000 & 1400 series
Front View
1.875"
(48mm)
➍
Top View
CROSSBRACE
➊
➌
1.75"
(45mm)
1000 series - 12"x16" cutout (305x407mm)
1400 series - 16"x16" cutout (407x407mm)
bottom of ice machine
side of ice machine
CAUTION
• Keep ventilation openings in the appliance enclosure clear of obstruction.
• To ensure proper ventilation (if not using supplied grille) carefully review air
circulation speci cations on facing page (4.1)
Access panel/
door on counter
1.75" (45mm)
➎
18" min.
(458mm)
3D Counter View
1000 series - 28.6" min. (727mm)
1400 series - 31.6" min. (303mm)
24.5" min.
(623mm)
CROSSBRACE
16"
(407mm)
No Lip
➋
1000 series - 12" (305mm)
1400 series - 16" (407mm)
VISION • RIDE Technology self-contained
9
Page 10
Install the ice transport tube.
Ice transport tube
5
5.1
Ice transport tube installation.
1/4"
➌
➋
Hot Water
160 F (71 C)
➎
➍
➏
➐
➊
1'
Ice transport tube tips
• Insulate entire length of ice transport tube
• Secure ice transport tube ➋ as needed to prevent dips and traps from forming.
For long tube runs see guide on page 19.
• Pitch tube at least 1/4" per foot (6,4mm/.3m)
• Ice transport tube must drain towards ice machine
Ice transport tube to Ice machine
• Be sure tube ends are square
• Heat end of transport tube in cup of 160 F (71 C) hot water to soften and spread with pliers ➎
before making connection to ease assembly
• Push ice transport tube onto ice machine nipple
• Install hose clamp
10
➐
➍
➊
➌
➏
self-contained VISION • RIDE Technology
Page 11
5.2
Dispenser ice transport tube installation
Ice tube retainer bracket
➋
1" (25mm)
ice tube
retaining
bracket
ice tube
Front View
VU155
➊
ice tube
retaining
bracket
thermostatthermostat
➋
tabs in ice tube
ice tube
retainer bracket
engage holes in ice
tube and hold tube
in place
ice tube
➊
Front View
VU300
➋
ice tube
ice tube
retaining
bracket
tabs in ice tube
retainer bracket
engage holes in ice
tube and hold tube
in place
➊
thermostat
• Check to make sure bin signal on ice machine control board is switched to 24 volt connection
• Push one end of ice transport tube(s) through hole(s) provided in side of dispenser
• Route tube into ice tube bracket inside dispenser and engage bracket tabs in holes located in
end of ice transport tube(s)
• Verify bin thermostat capillary tube is mounted correctly
➊
➋
VISION • RIDE Technology self-contained
11
Page 12
Connect utilities to louvered docking assembly.
External connections
6
6.1
Air-cooled ice machines only
➋
➊
• Remove access panel if necessary
• Install drain line
The rigid drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
• Install ice machine potable water
supply
• Replace access panel
➋
➊
.
6.2
Water-cooled ice machines only
➌
➋
➍
➊
• Remove access panel if necessary
• Install drain line
The rigid drain line from the ice machine
must have at least 1/4" per foot pitch.
• Connect cooling water supply
return
• Install ice machine potable water
supply
• Replace access panel
➌
➍
➊.
➋
and
12
self-contained VISION • RIDE Technology
Page 13
VISION • RIDE Technology self-contained
13
Page 14
Connect louvered docking assembly to ice machine.
CAUTION
• Plug must be accessible after nal installation.
• H_E1400A/W 230/50/1) requires a 20 amp circuit (4.00 mm
Air-cooled ice machines – follow steps 7.1 through 7.4.
2
wire)
Internal connections
7
7. 1
Ice transport tube
➋
➊
• Slide ice machine into louvered docking
assembly
• Insert ice transport tube all the way into
coupling and tighten nut rmly
➊
➋
7. 2
Potable water and drain lines
➊
• Insert potable water line into valve
• Push drain line over hose barb on
back of evaporator mount
➋
➊
➋
➋
➊
7. 3
• Remove twist tie
• Carefully pass plug thru opening and plug
Power cord
into wall outlet
7. 4
• Position plate into opening and secure
Power cord
with supplied screw
14
self-contained VISION • RIDE Technology
Page 15
➋
➊
Water-cooled ice machines – follow steps 7.5 through 7.10.
7. 5
• Install ice machine cooling water lines to
Cooling lines
Out
In
louvered docking assembly
7. 6
Ice transport tube
➋
➊
• Slide ice machine into louvered docking
assembly
• Insert ice transport tube into coupling and
tighten nut rmly
➊
➋
7. 7
Potable water and drain lines
➊
• Insert potable water line into valve
• Push drain line over hose barb on
back of evaporator mount
➋
➋
➊
➊
➋
7. 8
• Connect cooling water lines to ice
• Water valve is set at the factory. DO NOT
Cooling lines and power
Adjustment will void warranty and may damage equipment.
Do not adjust.
ATTENTION INSTALLER
Valve is preset at factory.
machine
remove seal or adjust water valve
➊
➋
VISION • RIDE Technology self-contained
15
Page 16
7. 9
Power cord
7. 1 0
Power cord
• Remove twist tie
• Carefully pass plug thru opening and plug
into wall outlet
• Position plate into opening and secure
with supplied screw
16
self-contained VISION • RIDE Technology
Page 17
VISION • RIDE Technology self-contained
17
Page 18
Install front cover to ice machine.
Front cover
8
Front cover installation – undercounter
➊
➋
➌
CAUTION
• Keep ventilation openings in the appliance enclosure
clear of obstruction.
• To ensure proper ventilation (if not using supplied grille)
carefully review air circulation speci cations in section
4.1
• Remove and discard plastic grille
• Apply supplied gasket material around
entire opening on skin to prevent air
recirculation
• Attach supplied metal grille to opening in
counter door (see section 4.1)
➋
➊
➌
Normal front cover installation
➋
➊
• Slide ice machine cover over machine
ensuring that tabs on back of cover
slip under louvers on back of louvered
docking assembly
• Insert and tighten two screws through
cover and into louvered docking assembly
➊
➋
18
NOTICE
Ice machine MUST be sanitized prior to operation!
Consult Operation and Service Manual provided with ice machine for sanitizing instructions.
self-contained VISION • RIDE Technology
Page 19
Long tube run recommendations
max. 2 ft (.6m)
➋
• Pitch ice transport tube to allow melt water to drain towards ice machine
• Secure insulated ice transport tube at least every 2 ft (.6m) to prevent dips or traps
1/4"
➊
➊
1'
➋
VISION • RIDE Technology self-contained
19
Page 20
Horizon, Maestro, Harmony, Ice Manager, SafeCLEAN, Sani-Sponge, RIDE and Vision are trademarks of Follett Corporation.
Chewblet is a registered trademark of Follett Corporation, registered in the US.
801 Church Lane • Easton, PA 18040, USA
Toll free (877) 612-5086 • +1 (610) 252-7301
www.follettice.com
00159921R06
3/12
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.