68
HES Folger Adam 310-6-X Electric Strike
Dimensions
Electric Strikes68Electric Strikes
310-
6-X
310- 6- 8
C
B
A
C
A
C
ABCDE
310 -6 -1
310 -6 -2
310 -6 -3
310 -6 -30
310 -6 -8
NOTE: Double-door models are available with four different center-to-center dimensions between latchbolt keepers. Keepers are wide enough to compensate for vertical-rod exit bolts, which may be as much as 3/8" (10mm) off center-to-center dimension, either way.
NOTE: When using an electric strike in conjunction with a vertical-rod exit device:
1. The bottom rod of the exit device must be removed or made inoperative.
2. The latchbolt of the exit device must be the Pullman or beveled type.
3. The latchbolt must be free-latching and remain projected while the door is open. Mechanisms that hold the latchbolt retracted while the door is open, and automatically release it when the door is closed, must be removed or made inoperative.
NOTE: The electric strike will not operate with a deadbolt style vertical rod.
14 -1/2"
[368.3mm]
15-1/ 8 "
[384. 2mm]
15- 3/4 "
[40 0.0 5mm]
13-1/ 8"
[333.4mm]
10-7/ 8"
[276.3mm]
4-3/8"
[111.1 25 m m]
5"
[127m m]
5-5/8"
[142 .8 m m]
3"
[76.2mm]
1-13/16" [46 mm]
1-13/16" [46 mm]
1-13/16" [46 mm]
1-13/16" [46 mm]
1-13/16"
[46 .mm]
1-3/4"
[44 .45 mm]
1-3/4"
[44 .45 mm]
1-3/4"
[44 .45 mm]
1-3/4"
[44 .45 mm]
1-3/4"
[44 .45 mm]
E
D
1-3/4"
[44 .45 mm]
1-3/4"
[44 .45 mm]
1-3/4"
[44 .45 mm]
1-3/4"
[44 .45 mm]
1-3/4"
[44 .45 mm]
Specifications
Certifications
UL 1034, burglary-resistant listed
UL 294 listed
ANSI/BHMA A156.31, Grade 1
RoHS compliant
Electrical (Continuous Duty)
510 mA at 12 VDC/250 mA at 24 VDC
310 -6 -1
For both leaves of a pair of doors when spacing of the vertical rods is be tween 4" [101.6mm] and 4-3/4" [120.65mm]
PK keeper standard
310 -6 -2
For both leaves of a pair of doors when spacing of the vertical rod s is b etween 4 -5/8" [117.475mm] and 5 -3/8" [136.525mm]
PK keeper standard
310 -6 -3
For both leaves of a pair of doors when spacing of the vertical rods is bet ween 5-1/4" [133.35mm] and 6" [152.4mm]
PK keeper standard
310 -6 -8
For only the active leaf of a pair
PK keeper standard
310 -6 -30
For both leaves of a pair of doors when spacing of the vertical rods is between 2-5/8" [66.7mm] and 3-3/8" [85.7mm]
PK keeper standard
How to Order
Series Fail Secure / Safe Voltage Finish Option (s)
310-6-X F – 24D – 612 –LCBMA
Complete Pacs
1 For use with vertical rod spacing
between 4" and 4-3/4"
2 For use with ver tical rod spacing
between 4-5/8" and 5-3/8"
3 For use with ver tical rod spacing
between 5-1/4" and 6"
30 For use with vertical rod spacing
between 2-5/8"and 3-3/8
NOTE: Electric strike compatibility is determined at time of electric strike product release. ASSA ABLOY is not responsible for incompatibility of products that have changed in design or craftsmanship by their respective manufacturers. When compatibility is a concern, contact Customer Support for application assistance.
Canada assaabloydss.ca | 800.461.3007 | sales.dss.ca@assaabloy.com
(blank) Fail Secure
(s ta nd ard )
F Fail Safe 612 Satin Bronze
12D 12 Volt 605 Bright Brass LCBMA Latchbolt &
24D 24 Volt 606 Satin Brass
613 Bronze Toned
629 Bright Stainless Steel
630 Satin Stainless Steel
Copyr ight © 2019, Hanche tt Entr y Systems , Inc., an A SSA ABLOY Group c ompany. All r ights re served . Reproduc tion
in whol e or in part w ithout the e xpress w ritten p ermissio n of Hanchet t Entry Sy stems, Inc . is prohibi ted.
Updated 6/7/19 Patent pending and/or patent www.assaabloydss.com/patents