IMPORTANT NNOTES
This fire is an Inset Live Fuel Gas Fire providing radiant and convected warmth. It is designed to operate on
Natural Gas following factory set adjustments. See Data Plate on appliance for gas type and pressure.
It is the LAW that all gas appliances and fittings are installed by a competent person (such as a CORGI registered fitter) and in accordance with the Gas Safety (Installation and Use) Regulations 1998, the relevant British
Standards for Installation, Codes of Practice and in accordance with the Manufacturers' Instructions. The
installation shall also be carried out in accordance with the following regulations:
The Building Regulations issued by the Department of the Environment, the Building Standards (Scotland)
(Consolidation) Regulations issued by the Scottish Development Department.
BS 5440 part 1, BS 5871 part 1, BS 6891
Note: For Republic of Ireland, reference should be made to the relevant standards governing installation.
Failure to comply with these regulations could lead to prosecution and deem the warranty
invalid.
This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space. The appliance does not use room air for combustion or operation
of the flue, but a supply of fresh air is advisable to maintain temperatures within limits. The
combustion air supply for this appliance is ducted from the outside air by an integral flue
system. The terminal of this flue system must always be kept clear of vegetation, new buildings, conservatories, extensions, sheds or other potential obstructions and able to perform
its function correctly.
Consult ALL instructions before installation and use of this appliance.
This appliance is provided with its own integral flue system and must only be used as
described in these instructions with that flue system alone. NEVER connect to, open up,
extend or in any other way modify the flue system and terminal other than shortening it for
installation as described in these instructions.
This appliance is free from any asbestos material. Refractories and coal bed are constructed
from ceramic fibre.
Secction Contentss Pagge NNo.
1.0 Important NNotes 1
2.0 Appliance DData 2
3.0 Installation RRequirements 3
4.0 Terminal LLocation 4
5.0 Site RRequirements 5
5.1 Ventilation 5
6.0 Unpacking tthe AAppliance 6
6.1 Component Checklist 6
7.0 Appliance IInstallation 7
7.1 Preparing the Appliance 7
7.2 Preparing the Wall Location 8
7.3 Outside Wall Apeture 8
7.4 Gas Supply Routes 9
7.5 Installation Method 1 10
7.6 Installation Method 2 10
7.7 Installation Method 3 11
7.8 Flue Preparation 12
Secction Contentss Pagge NNo.
8.0 Gas SSupply 13
9.0 Fitting CCavity BBox 14
9.1 Cable Fixing 15
10.0 Fuel BBed LLayout 16
11.0 Decorative FFrame aand HHood 17
12.0 TTesting aand CCommissioning 18
12.1 Operating the Appliance 19
12.2 Spark Failure 19
12.3 Setting Pressure 19
13.0 Briefing tthe CCustomer 20
14.0 Servicing 21
14.1 Cleaning the Coals 21
14.2 Dismantling/Servicing the Burner 22
14.3 Removing the Firebox 23
14.4 Pilot Assembly 23
14.5 Testing for Firebox Leakage 24
15.0 Troubleshooting GGuide 25