Model 922-MES
Managed Ethernet Switch
User Manual
MOOG PROPRIETARY AND CONFIDENTIAL INFORMATION
THIS TECHNICAL DATA/DRAWING/DOCUMENT CONTAINS INFORMATION THAT IS PROPRIETARY TO, AND IS THE EXPRESS PROPERTY OF MOOG
INC., OR MOOG INC. SUBSIDIARIES EXCEPT AS EXPRESSLY GRANTED BY CONTRACT OR BY OPERATION OF LAW AND IS RESTRICTED TO USE
BY ONLY MOOG EMPLOYEES AND OTHER PERSONS AUTHORIZED IN WRITING BY MOOG OR AS EXPRESSLY GRANTED BY CONTRACT OR BY
OPERATION OF LAW. NO PORTION OF THIS DATA/DRAWING/DOCUMENT SHALL BE REPRODUCED OR DISCLOSED OR COPIED OR FURNISHED
IN WHOLE OR IN PART TO OTHERS OR USED BY OTHERS FOR ANY PURPOSE WHATSOEVER EXCEPT AS SPECIFICALLY AUTHORIZED IN WRITING
BY MOOG INC. OR MOOG INC. SUBSIDIARY.
Page 2
Model 922-MES – User Manual
Document
Revision
Details of Revision
Author(s)
Date
[yyyy-mm-dd]
Rev. 1
Initial release.
ACC
2018-01-29
Document Number
Document Title and Description
922-2005-00
Configuration Drawing: Model 922-MES
922-0408-00
Model 922-MES GUI Software
922-0673-00
MES Core Features Manual
922-0673-01
MES Diagnostics Manual
922-0673-02
MES Diagnostics Protocol Manual
Document Revision History
Reference Documents
Focal Technologies Corporation Page ii
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Figure 9-2: Sample .NET GUI for Modbus TCP Access to Model 922-MES ..................................................... 9-3
Focal Technologies CorporationPage iv
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 5
Model 922-MES – User Manual
ACRONYMS AND ABBREVIATIONS
Bidi Bidirectional SFP transceiver
BER Bit Error Rate
CWDM Coarse Wavelength Division Multiplexing
DHCP Dynamic Host Configuration Protocol
DSL Digital Subscriber Line
EEPROM Electrically Erasable Programmable Read-Only Memory
GbE Gigabit Ethernet
GUI Graphical User Interface
IC Integrated Circuit
ICMP Internet Control Message Protocol
IP Internet Protocol
IGMP Internet Group Management Protocol
IWIS Intelligent Well Interface Standardisation
LED Light Emitting Diode
MAC Media Access Control (Ethernet)
MES Managed Ethernet Switch
MTBF Mean Time between Failures
MIB Management Information Base
MRC Media Redundancy Client
MRM Media Redundancy Manager
MRP Media Redundancy Protocol
MTBF Mean Time between Failures
OEM Original Equipment Manufacturer
PCB Printed Circuit Board
PCBA Printed Circuit Board Assembly
PLC Programmable Logic Controller
PLM Power Line Modem
PPP Point-to-Point Protocol
PTP Precision Time Protocol
PRBS Pseudo-Random Bit Sequence
QoS Quality of Service
RSTP Rapid Spanning Tree Protocol
RTU Remote Terminal Unit
SCM Subsea Control Module
SEM Subsea Electronics Module
SELV Safety Extra Low Voltage
SFP Small Form-factor Pluggable (Transceiver)
SHDSL Symmetrical High-Speed Digital Subscriber Line
Focal Technologies CorporationPage v
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 6
Model 922-MES – User Manual
SMT Surface Mount Technology
STP Spanning-Tree Protocol or Shielded Twisted Pair (cable)
TCP Transmission Control Protocol
TTL Transistor-Transistor Logic
uC Microcontroller
UDP User Datagram Protocol
VLAN Virtual Local Area Network
WDM Wavelength Division Multiplexer
Focal Technologies CorporationPage vi
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 7
Model 922-MES – User Manual
1.0 Introduction
A highly reliable managed Ethernet switch is required for use in subsea control networks to provide both copper
and optical links for 10/100/1000 Mbps communications using standard open protocols.
Focal’s Model 922-MES board is a layer 2 managed Ethernet switch (MES) with ten ports capable of
10/100/1000 Mbps link speeds. Two of these ports can be equipped with small form factor (SFP) transceivers
that support Fast (100Base-FX) and Gigabit Ethernet (1000Base-X).
The MES provides a configurable managed switch for use in subsea distribution units or Subsea Electronics
Modules (SEMs). Interchangeable fiber optic transceivers allow for port configuration as low-power optical links
to tie-ins and other subsea nodes or as high-power optical links to the surface via long optical umbilical cables.
Complete redundancy can be achieved using multiple cards within a distribution unit or SEM. Redundancy
protocols supported by the MES include MRP (Media Redundancy Protocol) and RSTP (Rapid Spanning Tree
Protocol).
Advanced diagnostics provide real time health monitoring of the system and include optical SFP information,
temperature, voltage, current, humidity, Ethernet link status, and Ethernet switch configuration. The MES
provides diagnostics access via Telnet and Modbus TCP.
Focal’s subsea qualified fiber-optic SFP transceivers are recommended for use with this board. Options available
include bidirectional transceivers and CWDM transceivers with support for 50 km, 100 km and up to 200 km
range.
The following features and processes are used to ensure reliability and increase product life:
Conductive cooling and detailed thermal analysis
Advanced diagnostics and health monitoring via Modbus TCP
Use of industrial temperature range electronic components
No fuses, electrolytic or tantalum capacitors
Environmental stress screening
Full qualification testing per API 17F / ISO 13628-6
Traceable components
Use of field-proven electrical and optical components
Design for vibration, shock and EMC
Focal Technologies Corporation Page 1-1
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Figure 1-1: Model 922-MES
Page 8
Model 922-MES – User Manual
Ethernet Interfaces (SIIS Level 3)
No. Ports
8 x Copper (via DIN connector)
2 x Optical (via SFP cages)
ESD and transient suppressors (TVS)
500 Vrms isolation
Ethernet Switch
Layer 2 Functions
Includes broadcast storm protection,
802.1q VLAN, 802.1p port priority, port
mirroring, aging
Time
Synchronization
IEEE 1588v2 PTP (E2E)
One step end-to-end transparent clock
IP Configuration
DHCP with configurable static IP fallback
Diagnostics
and Control
Parameters
Includes temperature, humidity, voltage,
current draw, optical power (Tx/Rx), on
time and power off events, Ethernet port
status/configuration, MIB counters, card
mfr. data (s/n, p/n, F/W revision)
Redundancy
RSTP, MRP (manager, client)
Options
HSR, PRP
Optical1
Wavelengths
1310 nm and 1550 nm standard
CWDM wavelengths (1471 to 1611 nm)
Optical Power
Budget
20 to 45 dB, depending on SFP installed
Range
10 to 200 km, depending on SFP
installed
Options
Bidirectional (single fiber) transceivers
1
See Subsea Qualified SFP Modules datasheet for available optical transceivers.
Factory Acceptance Test (FAT)
At Tmin and Tmax design temperatures
Qualification
ISO 13628-6, API 17F (Q1 Levels)
Includes 30 g shock, 5 g vibration
Firmware Update
Failsafe remote firmware update
Options
Environmental Stress Screening (ESS)
Custom qualifications per OEM
specification
Environmental
Temperature
-18 °C to +70 °C (design and operation)
-40 °C to +85 °C (storage)
Humidity
5% to 85 % RH, non-condensing
2.0 Specifications
Table 2-1: Specifications
Focal Technologies Corporation Page 2-1
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 9
Model 922-MES – User Manual
MODEL 922
MANAGED
ETHERNET
SWITCH
(MES)
CU1
CU2
CU3
CU4
CU5
CU6
CU7
CU8
SFP1
SFP2
MEDIA TYPES
(COPPER)
10BASE-T
100BASE-TX
1000BASE-T
MEDIA TYPES
(OPTICAL)
100BASE-FX
1000BASE-X
SFP
CU1
CU2
CU3
CU4
CU5
CU6
CU7
CU8
SFP1
SFP2
96-PIN HEADER
POWER CIRCUITRY
PHYs & QUAD
MAGNETICS
PHYs & QUAD
MAGNETICS
+24VDC
DIAG-uC
MES
CORE
P2
P3
P4
P5
P6
P7
P8
P9
P0
P1
P11
P10
3.0 Architecture Overview
The Model 922-MES may be configured with optical links for long distance connections from subsea to surface
or long distance optical links (up to 200 km) connecting between subsea nodes. Copper ports support links to
short distance (up to 100 m) sensors and PLCs.
The 922-MES supports:
Two (2) SFP Ethernet ports for 100BASE-FX / 1000BASE-X operation
Eight (8) Copper Ethernet ports for 10BASE-T /100BASE-TX / 1000BASE-T operation
The Ethernet ports and media types available for the MES is shown in the figure below.
The 922-MES PCB has a Eurocard form factor with a 96-pin DIN header at the back for access to eight copper
ports (CU1 to CU8) and power. The two SFP transceiver cages at the front provide access to SFP1 and SFP2
ports.
Figure 3-2: Model 922-MES Block Diagram and Ports
Focal Technologies Corporation Page 3-1
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Figure 3-1: Model 922-MES Ethernet Ports
Page 10
Model 922-MES – User Manual
Port
Connected To
Connection Type
P0
SFP1
User-External
P1
SFP2
User-External
P2
CU1
User-External
P3
CU2
User-External
P4
CU3
User-External
P5
CU4
User-External
P6
CU5
User-External
P7
CU6
User-External
P8
CU7
User-External
P9
CU8
User-External
The MES core chip has the following port connections.
Table 3-1: MES Core Port Connections
Connection types shown as “User-External” (CU1-8 and SFP1-2) can be changed by the user as required to
accommodate system-specific requirements. The user must ensure that any switch configuration changes are
valid BEFORE saving it in EEPROM and that communications through all ports is as expected after
configuration.
Focal Technologies CorporationPage 3-2
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 11
Model 922-MES – User Manual
4x SMF
TO SURFACE
ENET
SWITCH
TX1
RX1
TX2
RX2
BACKPLANE
SENSOR 1
SENSOR 2
SENSOR 3
PLC
SERIAL
SERVER
CAT 5e
CAT 5e
CAT 5e
CAT 5e
1x SMF
TO SURFACE
l1, lll3, 5, 7
8-CHANNEL
CWDM
OPTICAL
MODULE
NODE 1
ENET
SWITCH
TX1
RX1
TX2
RX2
NODE 2
ENET
SWITCH
TX1
RX1
TX2
RX2
l1
l2
l3
l4
l5
l6
l7
l8
l2, lll4, 6, 8
3.1 Example Optical Topologies
The Ethernet switch-based architecture and the configuration adopted for the 922-MES can be used to satisfy
a number of different subsea operational requirements.
For example, more than one MES Ethernet modem can be used to provide full card redundancy. Alternatively,
configuring each card to connect to separate copper Ethernet devices provides additional throughput capacity.
Lastly, connecting a copper Ethernet channel between two modems (i.e. electrically daisy-chaining the second
card), can provide a second pair of optical connections for other subsea nodes. With RSTP functionality enabled
in the MES the copper ports can also be used to electrically daisy chain multiple cards using multiple copper
ports. The figures below illustrate some alternative optical topologies supported by this modem.
Figure 3-3: Many sensors transmitting via separate or redundant optical links
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 12
Model 922-MES – User Manual
2x SMF TO
NEXT NODE
2x SMF
TO SURFACE
l1
NODE 1
ENET
SWITCH
TX1
RX1
TX2
RX2
NODE 2
ENET
SWITCH
TX1
RX1
TX2
RX2
NODE 3
ENET
SWITCH
TX1
RX1
TX2
RX2
l1
l1
l1
l1
l1
l1
l1
Figure 3-5: Optical daisy chain of multiple Modems
Configuration and use of the optical and copper ports on the switch are set by a combination of installed optical
transceivers and switch register settings. The Ethernet switch settings may be changed from their default
settings using a Modbus TCP connection to the MES over any of the 8 copper or 2 optical Ethernet ports.
Focal Technologies CorporationPage 3-4
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 13
Model 922-MES – User Manual
Option
MES Core P/N
Description
Notes
1
922-1008-50
MRP (SFP1-2) + RSTP (CU1-8)
As-built. Factory default.
2
922-1008-55
RSTP All Ports (SFP1-2 + CU1-8)
Option per customer request.
4.0 Configuration
On power up, the 922-MES starts a boot-up sequence that includes hardware and software initialization of the
Ethernet switching functions. This initialization period typically takes about 1.5 minutes and during this time all
Ethernet ports are disabled. After this period the switch configuration is loaded from an EEPROM with factory
default settings which are listed in section 4.1. These default settings can be changed via any Ethernet port
using a Modbus or Telnet connection and also saved to the EEPROM by the user to accommodate specific
switch functions and network topologies.
MES cards with diagnostics firmware ≥0xA3 support saving the user’s switch configuration to EEPROM via
Telnet and Modbus. In addition to the standard boot-up process previously described, cards with uC DIAG FW
≥0xA3 have a second layer verification to ensure the MES core loads its configuration correctly. This layer of
verification consists of monitoring the MES core and ensuring the card boots-up correctly on power-up and that
the MES core operating system is running correctly. In the unlikely event that a failure is detected such that the
MES core cannot access the user EEPROM to load its configuration or the MES core stops responding, the card
will attempt to fix the problem on its own by self-rebooting (up to 3 times) and in where needed it will attempt to
re-load factory default backup switch configurations depending on the error detected. Note that error codes are
embedded in Modbus data and UDP heartbeat packets which are sent automatically by the card every 5 seconds
(factory default).
The MES card also includes a remote firmware upgrade feature which offers an upgrade path to support future
protocols or application specific requirements.
The card’s default Ethernet port settings are as follows:
Copper ports CU1-CU8 are 10BASE-T /100BASE-TX / 1000BASE-T with auto-negotiation and auto
MDI/MDI-X enabled.
SFP ports SFP1-SFP2 are 1000BASE-X.
Supported packet sizes are standard Ethernet frames (64-1518 bytes), Ethernet II type frame (1536
The configuration options for the card that are saved in non-volatile memory EEPROM include the following:
Ethernet Switch Settings
o Link speed, duplex and negotiation mode (per port)
o MRP mode (MRM or MRC) for SFP ports SFP1-SFP2.
o RSTP for copper ports CU1-CU8 (global)
Diagnostic Settings
o Network, IP configuration
o DHCP mode
o UDP heartbeat frame rate and type
o Serial diagnostics
Diagnostic interfaces to the card include Ethernet ports (any copper or SFP) for full diagnostics and control of
the board and a factory serial diagnostics interface via a 3.5 mm non-isolated RS-232 port which provides
basic read-only card configuration information and board status intended for factory bench testing.
The MES card is fully programmed at the factory (core, diagnostics, EEPROMs, etc.). MES core firmware options
are shown in the table below. By default the card is shipped with core firmware P/N: 922-1008-50 unless
otherwise requested or specified by the customer. The MES card’s diagnostics firmware (uC DIAG) P/N 9221008-00 is the same for both MES core FW options.
Focal Technologies CorporationPage 4-1
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Table 4-1: MES Core Firmware Options
Page 14
Model 922-MES – User Manual
Name
Parameter
Default Setting
Ethernet CU1-CU8 (Software)
Link Speed
10BASE-T /100BASE-TX / 1000BASE-T
10BASE-T /100BASE-TX / 1000BASE-T
Duplex Mode
Full-Duplex or Half-Duplex
Full Duplex
Negotiation
Autonegotiation Enabled / Disabled
Autonegotiation Enabled
RSTP
All ports On / Off
On
Ethernet SFP1-SFP2 (Software)
Link Speed
100BASE-FX / 1000BASE-X
1000BASE-X
Duplex Mode
Full-Duplex
Full Duplex
MRP
MRP: On / Off
Mode: MRC / MRM
MRP On, MRC mode (client)
Boot up (Hardware)
JP1
Factory Use Only
Open
JP2
Open: Normal operation (Internal Flash)
Close: uC DIAG code reset (on power-up
load from Factory Flash)
Open
JP3
Factory Use Only
Shorted
JP4
Factory Use Only
Shorted
Diagnostics – uC DIAG (Software)
Network
IP address
192.168.0.100*
Subnet
255.255.255.0
Gateway
192.168.0.254
Primary DNS
194.25.2.129
Secondary DNS
194.25.2.130
DHCP
Enable / Disable
Enable
Timeout (1-10 min)
5 min.
UDP Heartbeat
Format: Short (Normal) / Long
Short (Normal)
Interval (1-254)
5 seconds
4.1 Factory Default Settings
The card is shipped from the factory with default configuration settings as shown below and are applicable to
MES core FW P/N 922-1008-50 and diagnostics microcontroller FW P/N: 922-1008-00. Settings type marked
as “software” mean that they can only be changed via a diagnostics link to the card. Settings type marked as
“hardware” mean that they can only be changed via hardware modifications on the board.
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 15
Model 922-MES – User Manual
Name
Parameter
Default Setting
Ethernet Switch
Settings
On power-up load settings from:
(A) EEPROM (user/factory configuration)
or
(B) Fail-safe factory
Option A
Future Use – Factory Reserved Parameters (Software)
Reserved
Network
IP address
192.168.0.201*
Subnet
255.255.255.0
Gateway
192.168.0.1
Primary DNS
194.25.2.129
Secondary DNS
194.25.2.130
Reserved
DHCP
Enable / Disable
Disable
* Unique IP addresses should be assigned / configured for each MES card used on the same network.
Focal Technologies Corporation Page 4-3
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 16
Model 922-MES – User Manual
Cfg.
Description
Telnet Command
1
EEPROM Save: MRP ON in MRC mode
save mrp mode mrc
2
EEPROM Save: MRP ON in MRM mode
save mrp mode mrm
3
EEPROM Save: MRP OFF
save mrp mode off
Cfg.
Description
Telnet Command
1a
EEPROM Save: SFP 1 set for 1000BASE-X
save sfp mode sfp1 1000
1b
EEPROM Save: SFP 2 set for 1000BASE-X
save sfp mode sfp2 1000
2a
EEPROM Save: SFP 1 set for 100BASE-FX
save sfp mode sfp1 100
2b
EEPROM Save: SFP 1 set for 100BASE-FX
save sfp mode sfp2 100
Cfg.
Description
Telnet Command
1
EEPROM Save: uC DIAG IP
(e.g. IP = 192.168.0.100)
set ip 192.168.0.100
2
EEPROM Save: SW Core IP
(e.g. IP = 192.168.0.201)
set fpga ip 192.168.0.201
4.2 Initial User Setup
The card is fully operational with factory default settings shown in Table 4-2. The following settings are typically
reviewed by the end user and are changed as required depending on the network topology where the card will
be used.
SFP Port Mode of Operation (redundant or daisy chain):
MRP: ON / OFF
Mode: MRC / MRM
Note: In redundant operation (e.g. ring topology) where two MES cards can be connected together using both SFP ports, normally
MRP is ON with MRM mode at the surface card and MRP is ON with MRC mode at the subsea card. For daisy chain operation (two
SFPs active at the same time) the cards can be left in MRC mode or with MRP OFF.
SFP Media Type (link speed):
100BASE-FX / 1000BASE-X
Note: No changes are required for factory-provided SFPs. In cases where the end user installs third party SFPs, changes might be
required depending on the SFP type. It is highly recommended to use Focal approved SFPs to ensure reliable performance of the
card.
Network Settings:
Diagnostics
Factory reserved parameters
Note: Diagnostics is served by a microcontroller (uC DIAG) and provides access to all diagnostic options and management of the
card. The factory reserved parameters are intended for future use and could be used by a secondary microcontroller embedded in
the MES switch core.
4.2.1 Initial Card Configuration via Telnet
1. Connect a standard Ethernet cable between your PC and CU1 (or any other copper port) of the card under
configuration.
2. Power up the card (+24 VDC).
Note: The card boot-up time is about 1.5 minutes and on-board LEDs will indicate a physical link after this period of time. The user can
run continuous pings (IP: 192.168.0.100) to the card as a way to verify once a Telnet link can be established. By default, DHCP is
enabled and this might increase the time between power-up and initial ping responses.
3. Using a terminal emulator program, such as TeraTerm, establish a Telnet connection to the card using:
a. Host: 192.168.0.100
b. TCP Port #: 23
4. The “Model922 MES>” prompt will appear after a connection has been established. At this point Telnet
commands can be used to change and save new user settings. It is recommended to record the new settings
for future reference. Typical configuration options are shown below.
a. SFP port mode of operation.
b. SFP media type.
c. Network settings.
Note: For a complete list of available telnet commands refer to the “Telnet Interface” section of this document.
5. Power cycle the card for all changes to take effect.
Focal Technologies CorporationPage 4-4
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 17
Model 922-MES – User Manual
4.2.2 Initial Card Configuration via GUI
MES cards with diagnostics FW 922-1008-00 (uC DIAG) version ≥ 0xA4 can be configured using Focal’s sample
922-MES GUI P/N 922-0408-00. More details of the GUI are shown in the “Graphical User Interface (GUI)”
section of this document.
The card configuration procedure using the GUI is similar to the Telnet procedure. However, when using the
GUI the user should following steps.
1. Connect a standard Ethernet cable between your PC and CU1 (or any other copper port) of the card under
configuration.
2. Power up the card (+24 VDC).
3. Run the 922-MES GUI and follow the steps below in sequential order:
a. Add a new card configuration by clicking the top left corner “+” button (default factory diagnostics IP
address is 192.168.0.100).
b. Click the “Connect” button.
c. Click System Maintenance Boot Config Open Boot Config Editor. The “Model 922 Boot Config
Editor” window will appear.
d. Make the desired card configuration changes. E.g. SFP settings, MRP (if available), RSTP changes,
etc.
Note that in the “Model 922 Config Editor” window, changes made by the user will only take effect after
the “Save Configuration” button is pressed and after one subsequent power cycle.
To make experimental volatile changes (not saved in EEPROM) the “Ethernet Switch Settings” section
of the GUI should be used.
e. Click the “Save Configuration” button to save the new card settings to EEPROM.
f. Power-cycle one (1) time ONLY the card under configuration.
g. Wait for GUI reconnection.
h. Verify the card’s functionality and that the changes are as expected.
i. A GUI message will appear asking the user to confirm if the changes are ok.
i. If the user accepts the changes then the card will keep the new user configuration.
ii. If the user ignores the changes and does not confirm the changes via the GUI then the card will
revert to the last known configuration on the next power-cycle.
4. Change the diagnostics IP address via Telnet (if required) following the steps shown in the previous section
4.2.1 step 4c.
5. Power cycle the card for the changes to take effect.
6. (Optional) Reconnect with the GUI and then re-open the “Model 922 Boot Config Editor” window and click
“Export Configuration” to save a copy of the new user configuration to your local PC.
7. Done! The initial card configuration is completed.
Focal Technologies CorporationPage 4-5
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 18
Model 922-MES – User Manual
Card P/N
Description
Configuration Drawing
922-5012-97
Managed Ethernet Switch (MES), No SFPs, 6HP Front Panel,
DIN Code Strip
922-2005-00
922-5012-98
Managed Ethernet Switch (MES), No SFPs, 4HP Front Panel
922-2005-00
922-5012-99
Managed Ethernet Switch (MES), No SFPs, No Front Panel
922-2005-00
5.0 Hardware
The 922-MES can be ordered using the card level part numbers shown in the table below. Refer to configuration
drawing 922-2005-00 for more details.
Table 5-1: Card Ordering Part Numbers
The 922-5012-xx cards include a 922-0208-00 PCB assembly (PCBA) which is a standard 3U Eurocard form
factor of 100 mm x 160 mm.
This PCBA is designed for interfacing with a custom backplane in a Eurocard sub-rack (card cage) or wiring
harness using a 96-pin DIN 41612 connector. This connector provides the interface for power and eight (8)
copper Ethernet ports. On the front of the PCBA are two (2) SFP ports and a factory diagnostics port. Key part
locations are shown in section 6.1.
5.1 Card with Front Panel
Card P/N: 922-5012-98
This card includes a 4 HP front panel as shown in the figure below. This card will fit in a 4 HP wide slot (0.8 in
or 20.32 mm) in a 3U Eurocard sub-rack. The front panel covers the front end of the PCBA and includes a handle
to allow for ESD safe handling and installation via rack card guides. Front panel cutouts allow access to the SFP
ports and a factory diagnostics port. This PCBA also includes a heat plate for improved conductive heat
dissipation. The 922-5012-97 PCBA includes a code strip which is installed on the DIN connector and a 6HP
front panel (1.2 in or 30.48 mm). Note that SFPs are not included in the card assembly.
Figure 5-1: Model 922-MES PCBA with 4HP Front Panel
Focal Technologies Corporation Page 5-1
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 19
Model 922-MES – User Manual
5.2 Card with No Front Panel
Card P/N: 922-5012-99
This card does not include a front panel and is intended for bolt down installation on a metal plate, in which case
a dedicated wiring harness is needed for connection to the DIN header. Top and front views of this card are
shown in the figure below.
Figure 5-2: Model 922-MES PCBA with No Front Panel
5.3 General Board Handling
The 922-MES PCBA does not require forced air convective cooling. Generally heat from the card is conducted
through the mounting hardware, such as metal standoffs, or via the front panel to rack connections. If the card
is intended to be used for extended periods beyond +40 C ambient, other heat dissipation or heatsink options
should be considered to extended product life. Contact the factory for more information.
Care must always be taken during the handling of PCBAs to ensure product integrity. The following guidelines
should be adhered to in working with PCBAs:
Always handle boards by the edges and do not touch any connector pins or other exposed interface
contacts.
Handle boards at an ESD safe workstation with a clean surface. Maintain ESD precautions during
installation.
Store each card in a separate, ESD protective package.
Do not flex boards during handling or when mounted. The mounting surface needs to be flat and even
such that the board is not flexed when bolted down.
Do not cause unnecessary shock and vibration, such as dropping or rough handling of the boards.
Focal Technologies CorporationPage 5-2
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 20
Model 922-MES – User Manual
REF.
DESCRIPTION
SFP1-2
SFP CAGES
(ETHERNET SFP1-2)
JP2
uC DIAG CODE RESET
J3
FACTORY
DIAGNOSTICS
CONNECTOR
(RS-232)
J5
LED HEADER (I2C)
J11
DIN 41612 BACKPLANE
96-PIN CONNECTOR
(POWER AND
ETHERNET CU1-8)
D2-3,
D5-9,
D12-27
DIAGNOSTIC LEDS
M17
SENSOR (TEMP. AND
HUMIDITY)
J10
EXPANSION CONN.
(FUTURE USE)
J4/6/7/9
JP1/3/4
FACTORY USE
J4 SFP1 SFP2
JP2
JP3
JP1
J5
JP4
J10
D5 D9
D12 D27
J3
D2 D3
J6
J9
M17
J7
J11
6.0 Connectors and Pin Descriptions
6.1 Part Locations
Refer to the figure below for location of connectors, hard wired jumpers and on-board diagnostic LEDs on the
card. Note some factory testing headers and jumpers may not be exactly as shown.
Figure 6-1: Model 922-MES Part Locations (Top View)
Focal Technologies Corporation Page 6-1
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 21
Model 922-MES – User Manual
S/N
MAC-PL
MAC-UC
MAC-PS
The 922-MES card has three (3) unique MAC addresses used for diagnostics (MAC-UC) and Ethernet switching
functions (MAC-PS and MAC-PL). The location of the serial number and MAC addresses labels are shown in
the figure below.
Figure 6-2: Model 922-MES Part Locations (Bottom View)
Focal Technologies Corporation Page 6-2
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 22
Model 922-MES – User Manual
Table 6-1: On-Board Diagnostic LEDs
LED
LED Name
Note
D2
SFP2 LOS
1
D3
SFP1 LOS
1
D5
POWER
2
D6
SFP1 LINK
3
D7
SFP1 ACTIVITY
4
D8
CU1 LINK
3
D9
CU1 ACTIVITY
4
D12
SFP2 LINK
3
D13
SFP2 ACTIVITY
4
D14
CU2 LINK
3
D15
CU2 ACTIVITY
4
D16
CU3 LINK
3
D17
CU3 ACTIVITY
4
D18
CU4 LINK
3
D19
CU4 ACTIVITY
4
D20
CU5 LINK
3
D21
CU5 ACTIVITY
4
D22
CU6 LINK
3
D23
CU6 ACTIVITY
4
D24
CU7 LINK
3
D25
CU7 ACTIVITY
4
D26
CU8 LINK
3
D27
CU8 ACTIVITY
4
Jumper
Name
Note
JP1
FACTORY USE
OPEN: Default
JP2
uC DIAG
CODE RESET
This jumper is only checked by the software on power up.
OPEN (default): Diagnostics uC runs in normal operation.
SHORTED: Revert uC DIAG firmware to factory version.
JP3
FACTORY USE
SHORTED: Default
JP4
FACTORY USE
SHORTED: Default
D16
D5
D7
D9
D17
D18
D19
D20
D21
D22
D23
D24
D25
D26
D27
D13
D15
D6
D8
D12
D14
D2D3
6.2 Diagnostic LEDs
The table below describes the on-board diagnostic LEDs on the card. LEDs are intended for bench level
verification as typical status from installed equipment is accessed via Ethernet.
Notes:
1. Green: ON Solid = No loss of optical signal (No LOS). OFF = Loss of optical signal (LOS)
2. Green: ON Solid = Board is ON. OFF = Board is OFF.
3. Yellow: ON Solid = Ethernet Link Up. OFF = No Ethernet Link
4. Green: ON Solid = Ethernet Link Up. Blinking = Ethernet TX/RX Activity. OFF = No Ethernet Link.
6.3 Jumpers
The table below describes the hardware jumpers on the card.
Focal Technologies CorporationPage 6-3
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Table 6-2: Hardwire Jumper (as-built)
Page 23
Model 922-MES – User Manual
On-board Connector
Mating Connector
Ref
Description
Manufacturer
Manufacturer Part Number
Manufacturer Part Number
J11
96-Pin DIN 41612
Harting
0903-196-6921
09032966824 (Vert. PCB Mount)
J3
3.5 mm Stereo Jack
CUI Inc.
SJ1-3523NG
SP-3501
Pin
Name
Row A
Row B
Row C
1
DA+_CU1
REF_CU1
DB+_CU1
2
DA-_CU1
REF_CU1
DB-_CU1
3
DC+_CU1
DB+_CU5
DD+_CU1
4
DC-_CU1
DB-_CU5
DD-_CU1
5
DA+_CU5
DC+_CU5
DD+_CU5
6
DA-_CU5
DC-_CU5
DD-_CU5
7
VIN1+
VIN1+
VIN1+
8
VIN2+
VIN2+
VIN2+
9
DC-_CU2
DC+_CU2
REF_CU5
10
VIN-
VIN-
VIN-
11
VIN-
VIN-
VIN-
12
DD+_CU2
DD-_CU2
REF_CU5
13
DA+_CU2
DB+_CU2
REF_CU2
14
DA-_CU2
DB-_CU2
REF_CU2
15
DA+_CU3
DB+_CU3
REF_CU3
16
DA-_CU3
DB-_CU3
REF_CU3
17
DA+_CU6
DD+_CU3
DC+_CU3
18
DA-_CU6
DD-_CU3
DC-_CU3
19
DC+_CU6
DB+_CU6
REF_CU6
20
DC-_CU6
DB-_CU6
REF_CU6
21
DA+_CU7
DB+_CU7
DD+_CU6
22
DA-_CU7
DB-_CU7
DD-_CU6
23
DC+_CU7
REF_CU7
DD+_CU7
24
DC-_CU7
REF_CU7
DD-_CU7
25
DA+_CU8
DB+_CU8
DD+_CU8
26
DA-_CU8
DB-_CU8
DD-_CU8
27
DC+_CU8
DC+_CU4
REF_CU8
28
DC-_CU8
DC-_CU4
REF_CU8
29
DA+_CU4
DB+_CU4
REF_CU4
30
NC
NC
DD+_CU4
31
DA-_CU4
DB-_CU4
REF_CU4
32
NC
NC
DD-_CU4
C
B
A
132
6.4 Connector Part Numbers
The 922-MES connectors and their mating connector part number is shown below.
Table 6-3: Connector/Mating Connector Part Numbers
6.5 96-pin DIN 41612 Backplane Connector (J11)
A 96-pin DIN 41612 backplane connector provides access to eight (8) copper ports (CU1-CU8) and power
interface.
Figure 6-3: DIN 41612 (96-pin) Backplane Connector (Front View)
Table 6-4: DIN 41642 (96-pin) Backplane Connector Pin-out
Notes:
1. NC = No Connect
2. VIN1+ (24V INPUT1+) and VIN2+ (24V INPUT2+) are independent power inputs, each with reverse protection diodes and can be
connected to separate power supplies or both from one power supply.
Focal Technologies CorporationPage 6-4
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 24
Model 922-MES – User Manual
CAUTION
This RS-232 serial diagnostics port is non-isolated and it is intended for bench testing and factory
debugging purposes only. This port is not intended for final installations.
6.6 3.5 mm Jack Factory Diagnostics Port (J3)
The factory diagnostics port (J3) shown in Figure 6-1 is an RS-232 serial port. This port is non-isolated and it is
intended for bench testing and factory debugging purposes only.
This port outputs basic diagnostic information on power-up which includes network settings, MAC addresses
and other configurations of the card. The signal levels on this port are compatible with RS-232 levels and can
be directly connected to a PC or other terminal device for bench testing and debugging purposes. This port is
an output only and writing to this port is not supported and will have no effect.
When serial diagnostics is enabled a continuous stream of hexadecimal data separated by commas is sent via
the serial port. By default serial diagnostics is disabled and Telnet commands can be used to enable or disable
this function.
Note: For more information on the use of this interface please contact the factory.
6.7 LED Connector J5
The 922-MES card has the capability of driving an array of external LEDs on a PCBA via a connection to J5.
Typically this configuration is used on the topside card with a front panel that includes an LED PCBA. Contact
factory for details and options.
Focal Technologies CorporationPage 6-5
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 25
Model 922-MES – User Manual
6.8 Electrical Interfaces
This section shows the schematics of the user accessible interface circuits, which are the +24V power input and
copper Ethernet interfaces.
6.8.1 +24V Power Input
The power input interface schematic in the figure below shows the input protection diodes, common mode EMC
filter and DC-DC converter. Power input must be within +20VDC to +28VDC. Ideal input voltage is +24VDC and provided by a supply with a Safety Extra Low Voltage (SELV) rating. See section 2.0 for specification
details.
Figure 6-4: Power Input Interface Schematic
6.8.2 Ethernet Interface
The Ethernet interface schematic shown in the figure below, is identical for all Ethernet copper ports. This
schematic shows the transformer isolation, REF (shield), and termination used.
Figure 6-5: Copper Ethernet Interface Schematic
Focal Technologies Corporation Page 6-6
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 26
Model 922-MES – User Manual
MOUNTING HOLES: A
(CHASSIS CONNECTION)
A
A
A
A
A
AA
A
CONNECTOR
MOUNTING
HOLES
(ISOLATED)
6.8.3 Isolation and Grounding
A “chassis ground” is provided on the printed circuit board for EMC and ESD performance. It is accessible via
eight mounting holes, as shown in the figure below, and may be connected to a metal enclosure or mounting
plate with appropriate conductive hardware. As the card is not intended for use with primary circuits or other
hazardous voltages, the chassis node is a functional earthing point and is not intended as a protective earth
(PE) terminal.
The two isolated mounting holes on the 96-pin DIN connector are intended solely for mechanical support. If
required these two holes can be accessed by removing the existing connector mounting hardware. The five
mounting holes “A” close to the DIN connector are normally used to hold a heat plate in place. If required these
five holes can also be accessed by reconfiguring the heat plate hardware. Please consult the factory for
recommendations.
Figure 6-6: Mounting Holes Locations
Reference (REF) lines are provided with each copper port and may be used as shield reference connections for
shielded twisted pair (STP) cabling. Typically, unshielded twisted pair (UTP) cabling should be used, such as
Cat 5e or better. If STP cabling is required, shields may need to be terminated and connected to the enclosure
entry point. Note that the REF lines are connected to chassis through a parallel capacitor and 10 MΩ bleed
resistor.
The 922-MES is intended for use with SELV rated power supplies and Ethernet Environment A, as defined by
IEEE 802.3 section 27.5.3. Extension of copper Ethernet segments that cross Environment B boundaries may
require additional isolation or use of the optical links for such connections. Note that the 24 VDC power lines
VIN+ and VIN-, are isolated from chassis.
Focal Technologies CorporationPage 6-7
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 27
Model 922-MES – User Manual
Observe the bend radius of fiber optic cables at all times
When mounting, disassembling, or reassembling the cards, ensure that no fibers are subjected to bends in
excess of those held by the natural routing of the fibers. The minimum bend radius of standard singlemode
SMF-28e fibers should generally be no less than 25 mm, though single loops may be less than this – as low
as 15 mm – without damaging the fibers. Keep in mind that allowable values are dependent on the type of
fiber and the environment, and cable manufacturers typically specify the minimum bend radius. Avoid even
temporary bends with a radius less than 15 mm, which may induce cracks that affect long-term reliability of
the fibers. Use bend insensitive fibers where tight bends are expected during installation or operation.
Ensure fiber optic components are of the same type
All jumpers, cables, connectors, couplers, and Fiber Optic Rotary Joints (FORJs) used in the external
optical system connecting the card must use the same type of fiber, i.e. all components in the fiber link
should be singlemode. A single mismatched jumper in the system may cause intermittent or persistent
optical link errors. Do not rely on cable jacket or connector colors alone to determine the type of optical
fiber.
7.0 Optical Interface
7.1 Optical Transceivers and Wavelength
The Model 922-MES card communicates optically using one or two small form-factor pluggable (SFP)
transceivers per card. The device can be ordered with a wide selection of qualified SFPs, depending on the
application distance, optical budget, and fiber count requirements. Depending on the SFPs selected, the card is
able to function on one (1) to four (4) fibers. The MES supports SFPs with 100 Mb/s and 1 Gb/s optical data
rates. In general, lower optical data rates have higher optical power budget and longer range.
Standard, API qualified, SFPs utilize two separate fibers, typically one transmitting in each direction at 1310 nm
for shorter links (< 50 km), or 1550 nm for longer links, up to 200 km at 100 Mb/s.
Bidirectional SFPs, or “Bidis”, are available with integrated wavelength division multiplexing (WDM) optical
components, providing bidirectional operation using two wavelengths on a single fiber (e.g. 1550/1490 nm or
1310/1550 nm). Bidi SFPs are typically limited to a range of 50 km.
SFP transceivers with CWDM wavelengths (1471 nm to 1611 nm) may be used to combine up to four sets of
modems (i.e. 8 CWDM wavelengths) on the same fiber. CWDM systems require additional optical modules that
may include power splitters, for redundancy, and/or CWDM couplers for combining or separating wavelengths.
Optical modules are available from the factory in a variety of packaging options. Note that the combination of
multiple wavelengths on a single fiber may cause the combined optical power levels to exceed Class I power
limits.
Typical 1 Gb/s SFP options include a Bidi version (1550/1490 nm) with 50 km range and a CWDM version
(1551 nm) with 100 km range. Contact the factory for qualified SFP options and for instructions on installation.
7.2 Optical Fiber
The card communicates using up to two SFP transceivers per card, which requires up to four fibers. The fiber
must be singlemode, such as SMF-28e (9/125 μm) or equivalent. For links over 100 km, dispersion shifted
singlemode fiber (SMF-DS), should be considered to minimize dispersion on the 1550 nm wavelength.
Bend-insensitive jumpers with reduced boot-lengths may be used to allow for fiber routing to the card within
confined spaces, such as in subsea pressure housings. These jumpers are available from the factory or third
party vendors. Regardless of the fiber types used, the following handling guidelines should be followed:
Focal Technologies Corporation Page 7-1
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 28
Model 922-MES – User Manual
Active optical outputs should NEVER be viewed with a magnifying
device of any kind (e.g. fiber microscope).
Always turn off all transmitters before inspecting fibers, optical
connectors, or optical bushings.
7.3 Optical Budget, Range, and Bit Error Rate (BER)
A variety of approved and tested SFP transceivers are available from Focal Technologies for maximum
distances from 10 km to 200 km. The optical power budget is dependent upon the SFPs selected, but typically
varies from 16 dB to 45 dB with an optical bit error rate (BER) of 1 x 10
of available, API qualified transceivers.
Optical receivers will experience errors if the received optical power is too low (i.e. below the receive sensitivity
of the photo detector). Ensure the total optical losses of the components in the external cable system (jumpers,
cables, connectors, couplers, etc.) are less than the specified optical power budget of the SFP combination
used. For detailed measurements or trouble-shooting, a calibrated optical power meter is recommended.
Optical receivers can also saturate and experience errors if the received optical power is too high. This is more
likely to occur (especially in a lab environment) when using high power transceivers. Use a 5 or 10 dB fixed
attenuator in line with each fiber during bench tests or with short, low loss links to ensure a minimum level of
attenuation is present. A variable optical attenuator (VOAT) can be used for simulating system losses or testing
the maximum insertion loss supported. In some high power systems, receivers can actually be damaged by
excessive optical power, so a fixed attenuator is recommended even when using a VOAT to ensure a minimum
attenuation at all times.
Adding attenuators for bench testing simulates only the insertion loss of a field system. Dispersion effects are
not simulated with attenuators and should be verified with spools of test fiber matching the length of the system
being designed. Dispersion effects con incur a power penalty of 1-2 dB. Please contact the factory for assistance
with optical system analysis and recommendations.
-12
. Contact the factory for the current list
7.4 Return Loss Tolerance
The optical system external to the card should have a minimum of 20 dB return loss. Excessive optical reflections
may degrade optical budget and/or reduce transceiver lifetime.
For systems with bidirectional optical transmission on a single fiber, sufficient reflected optical power on one
wavelength can interfere with received power on another wavelength and cause data errors. Return loss
specifications for systems with WDM or CWDM couplers must be determined based on a more detailed analysis
of the maximum link attenuation, optical levels, and filter characteristics, but typically 25-30 dB return loss is
sufficient to ensure reflected optical power does not cause link errors.
7.5 Optical Power
All optical power levels are within Class I limits (eye-safe), however as general safe practice, fiber connectors
should not be held close to the eye for inspection. Note that all of the SFP optical wavelengths used for Model
922 links are infrared and not visible, even at high power levels.
Focal Technologies Corporation Page 7-2
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 29
Model 922-MES – User Manual
Optical Connectors Care:
It is critical to ensure all fiber connectors are clean and free of dirt and debris. Even a small amount of dirt
or fluid contaminant may degrade link performance, and most reported optical link problems are due
simply to poor or contaminated optical connections.
Keep protective dust covers on fiber connectors and bushings when not in use.
Do not touch the white ceramic ferrules of the connectors with bare hands or objects other than
cleaning materials.
Prior to making a fiber connection, clean the barrel and tip of the ferrule using a suitable solvent,
such as reagent grade isopropyl alcohol, and a lint-free optics cleaning tissue, such as Kimwipes®
EX-L. Carefully dab any dirt or debris off the face of the ceramic ferrules. Excessive dirt may need
to be cleared with pressurized air from a can prior to wiping the ferrule to avoid scratching the
fiber itself. Do not used air from a compressor as it may be contaminated with oil.
During mating or un-mating of fiber connectors with bushings, keep the connector aligned as
straight as possible. Avoid side loading the ceramic ferrule, which can crack the internal alignment
sleeve in the bushing.
Each fiber connector should be inspected with a handheld fiber microscope prior to final assembly
to ensure there are no scratches, pits, debris, or fluid contamination on the fiber face. Ensure
connectors do not have any optical power present prior to inspection, e.g. with a handheld power
meter.
Ferrule
Tx
(Optical
Output)
Rx
(Optical
Input)
7.6 Optical Connectors
Optical connectors for the SFPs qualified for use with the 922-MES are LC type. The mating connector for the
LC interface, with a standard boot, is shown in the figure below. Ruggedized (metal) LC compatible connectors,
such as the Molex LC2+ and Diamond F3000, can also be used.
Figure 7-1: LC connector with Standard Boot
Standard SFP optical transceivers typically have a transmit and receive optical bushing (LC type) for dual fiber
operation. The transmit side (Tx) and the receiver side (Rx) of an SFP is shown below.
Figure 7-2: Tx and Rx ports of an LC-type SFP Transceiver
Focal Technologies Corporation Page 7-3
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 30
Model 922-MES – User Manual
8.0 Functionality
The Model 922-MES is a layer 2 managed Ethernet switch (MES) implemented in a fully reconfigurable
FPGA-based platform, including DDR3 memory and two microcontrollers to enable many existing and future
protocols, as well as application specific code.
The MES provides access to ten Ethernet ports capable of 10/100/1000 Mbps link speeds. Two of these ports
can be equipped with small form factor (SFP) transceivers that support Fast Ethernet (100Base-FX) and Gigabit
Ethernet (1000Base-X).
Redundancy protocols supported by the MES include MRP (via two SFP ports) and RSTP (via eight copper
ports). Additional redundancy protocols can be supported, e.g. HSR/PRP. Please contact the factory for
availability.
Ethernet ports are configured manually or through autonegotiation for 10/100/1000M operation on copper ports
and manually for 100/1000M for SFP ports. The card also provides support for advanced timing protocols, such
as IEEE 1588v2 (PTP), which is critical for synchronization in many sensor applications.
A range of subsea-qualified, pluggable, fiber-optic transceivers enables many optical topologies, including dual
fiber mode and bidirectional operation with up to 16 wavelengths on a single fiber using CWDM (Coarse
Wavelength Division Multiplexing) technology. Fiber umbilicals of up to 200 km length are supported.
The Model 922-MES GUI software (P/N 922-0408-00) provides advanced diagnostics via Modbus TCP for
real-time health monitoring of the system as well as easy configuration of all interfaces and modes of operation.
A proven RTOS (Real Time Operating System) and remote firmware upgrade feature increase system reliability
while offering an upgrade path for future protocols or application specific requirements.
8.1 Network Settings and Accessibility
8.1.1 IP Address Configuration
Each 922-MES board is assigned with three unique MAC addresses during factory configuration. The MAC
addresses are marked on the board, as shown in Figure 6-2, and recorded at the factory with cross-reference
to serial number, and thereby customer order, should it ever need to be retrieved.
There are two IP addresses (diagnostics and factory-reserved) for the MES. The diagnostics IP can be assigned
statically or dynamically using DHCP. Either mode can be enabled remotely using a virtual Telnet terminal over
any Ethernet port, followed by powering cycling the board after the changes has been submitted to the card.
The diagnostics IP address provides full diagnostics and control of the card and is served by a master
microcontroller (uC DIAG). The factory-reserved IP address is intended for future use and is normally static and
it is setup by the user on initial card configuration.
By factory default, the MES card obtains its diagnostics IP address using DHCP (i.e. dynamic IP allocation),
configured with a 5 min. timeout. If the connecting network does not support DHCP to provide a dynamic IP
within this time frame, the card will automatically revert to use its locally stored (static) IP address and network
settings. Factory default network parameters are shown in Table 4-2.
8.1.2 IP Connectivity
The MES hosts the following simultaneous IP connections:
Up to four Modbus TCP clients over any Ethernet port, including ‘remotely’ (i.e. from surface card)
via the optical ports. The Modbus TCP connection provides diagnostics information, which can be
accessed using Modbus software (e.g. ModScan or sample 922-MES GUI).
One Telnet over any Ethernet port, including ‘remotely’ via the optical ports. Typically used for initial
card configuration (e.g. redundant operation mode of and network settings), basic card diagnostics
and link status information for copper and SFP ports.
Focal Technologies CorporationPage 8-1
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 31
Model 922-MES – User Manual
MES Core FW P/N:
922-1008-50
SFP1 and SFP2 Only
8.2 Redundancy Configuration
The redundancy protocols supported by the 922-MES are presented in the following subsections.
8.2.1 Media Redundancy Protocol (MRP)
The Media Redundancy Protocol (MRP) is one of the standard solutions for redundancy in networks with a ring
topology. It is designed to react deterministically on a single failure of an inter-switch link or switch in the network,
under the control of a dedicated media redundancy manager (MRM) node. Ring redundancy allows the
implementation of high-availability ring-shaped network structures, and this protocol enables converting a line
structure to a redundant ring structure.
The MRP defines a media redundancy manager (MRM) and media redundancy client (MRC). An MRP ring
consists of one switch in MRM mode and one or more switches in MRC mode. The MRM sends MRP test frames
in both directions of the ring. These test frames contain a special MAC address and are forwarded by the MRC
switch(es) in the ring. The ring is detected as closed if the test frames arrive on both ends back to the MRM in
certain period of time and in this case the MRM opens the ring by changing one of its port states to blocked and
the other to forwarding. This blocked port only sends test and management MRP frames. Data frames are sent
via the port that is in the forwarding state.
The MES supports the MRP protocol in the role of a media redundancy manager (MRM) or the role of a media
redundancy client (MRC). Both protocols are implemented in the MES switch core at the MAC layer. Only the
two SFP ports on the MES support the MRP protocol and when this function is enabled, these two ports are
used as the ring ports. Note that by default the MES cards are shipped from the factory with MRP enabled in
MRC mode which allows the use of the two SFP ports at the same time. When connecting two MES card ports
via both SFP ports for redundancy purposes, ensure that one card is configured as MRM (typically the topside
unit) and the other as MRC (typically the subsea unit).
During normal operation, the network is in a ring-closed state where an actual physical ring topology exists and
one of the MRM ring ports is in a blocked state while the other is in a forwarding state (loop avoidance). The
ring ports of the MRC (or MRCs) in this case would be in a forwarding state. A ring-opened state is entered
when a segment of the ring has a failure and, for example if the failure is between two MRCs, then both ring
ports of the MRM would enter a forwarding state. In both ring-closed and ring-opened states the network logical
topology is a stub.
In MRM mode the card performs the following functions:
Controls the ring state by sending MRP test frames at a configured time period in both directions of the
ring.
Sets one ring port to forwarding state and the other port to blocked state if it receives its own MRP
test frames.
Sets both ports to forwarding if it does not receive its own MRP test frames on both ring ports within a
configured time.
Transmits MRP topology change frames to indicate changes in the ring state to the MRCs.
The ring ports take one of the following port states:
Blocked: Ring ports drop all received frames except MRP control frames.
Forwarding: Ring ports forward all received frames.
In MRC mode the card performs the following functions:
Detects a failure or recovery of a ring port link and notifies the change via both ring ports.
Processes the topology change frames and clears its filtering data base (FDB) if requested in a given
MRP time interval.
Forwards MRP frames such as: test, topology change, link change, in-test, in-link change, in-topology
change and in-link status poll between its ring ports only.
The ring ports take one of the following port states:
Focal Technologies CorporationPage 8-2
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 32
Model 922-MES – User Manual
MES Core FW P/N:
MES Core FW P/N:
922-1008-50
922-1008-55
CU1-8 Only
SFP1-2 and CU1-8
Blocked: Ring ports drop all received frames except MRP control frames.
Forwarding: Ring ports forward all received frames.
The following are some prerequisites for proper MRP operation:
There is only one ring manager in the ring
All ring participants support MRP
Ring participants are connected to each other via the ring ports
All ring participants support the configuration time specified by the manager
8.2.2 Rapid Spanning Tree Protocol (RSTP)
The Spanning Tree Protocol (STP) is a network protocol that enables loop-free switching via the systematic
deactivation of redundant connections. STP allows the inclusion of redundant (spare) links to provide an
automatic backup path if an active link fails.
The Rapid Spanning Tree Protocol (RSTP) uses the same algorithm as STP for determining the tree structure.
RSTP mainly changes and adds new parameters to speed up the reconfiguration process if a link or bridge
(switch) becomes non-functional.
The 922-MES default core FW 922-1008-50 supports the Rapid Spanning Tree Protocol (RSTP) on all eight (8)
copper ports (CU1 – CU8) while also supporting MRP on SFP1-2. MES core FW 922-1008-55 supports RSTP
on all ports (SFP1-2 and CU1-8) and does not provide MRP functionality on the SFP1-2 ports. The RSTP
features included in the MES are:
Very low latency Ethernet packet switching due to hardware-based frame handling.
Hardware-based frame reception, frame filtering based on MAC table, port state and filtering database
and frame transmission.
RSTP algorithm running via embedded software implementation and direct communication to hardware
of state changes (discarding, learning or forwarding)
By default all CU1-8 copper ports on the MES have RSTP enabled. If the RSTP function is not required, this can
be changed via the Telnet interface (refer to the Telnet Commands section of this document for more details) or
via the 922 MES GUI (only available with cards with uC DIAG FW 922-1008-00 ≥ 0xA4).
RSTP global enable/disable function for all ports is available in all MES core firmware versions. RSTP per-port
ON/OFF functionality saved in EEPROM is available in core FW 922-1008-50 ≥ 0xA4 and FW 922-1008-55 ≥
0xA1.
8.2.3 HSR/PRP
The 922-MES card could be upgraded to support additional redundancy protocols such as High-availability
Seamless Redundancy (HSR) or Parallel Redundancy Protocol (PRP). Both of these protocols allow
interruption-free redundancy. Contact factory for details.
8.3 MES Core Features
The MES core support various Ethernet switch features including:
Virtual Local Area Network (VLAN)
Priority
Broadcast Storm Protection
Port Mirroring
Aging
Static MAC Table
Focal Technologies Corporation Page 8-3
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 33
Model 922-MES – User Manual
IEEE 1588 v2 PTP E2E
Management Information Base (MIB) Counters
Detailed description of these features is available in document P/N: 922-0673-00.
Focal Technologies CorporationPage 8-4
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 34
Model 922-MES – User Manual
8.4 System Features
The 922-MES has several special system features to support subsea applications:
Robust remote firmware upgrade with permanent factory code backup
Saving user switch configurations
DHCP enabled/disabled with timeouts
Software reset
Watchdog reset
Automatic user switch configuration loading
Configurable UDP heartbeat with critical card status
Multiple Modbus clients
Validation of IP configuration changes
8.4.1 Remote Firmware Upgrade
The 922-MES card allows users to update the application firmware for the diagnostics microcontroller (uC DIAG)
over a TCP/IP interface using a proprietary protocol with multiple verification stages. Focal provides the
necessary software and instructions for performing infield firmware upgrades.
After the Firmware update of the uC DIAG is completed, the card will automatically reset several times
before finalizing the update. In case of a failure during a firmware update, the card will automatically
load the factory default application firmware.
Future firmware updates to the diagnostics microcontroller enable the possibility of upgrading and adding special
features to the FPGA-based MES Ethernet switch core to meet future market and customer needs using the
same hardware platform.
8.4.2 Saving User Switch Configuration
The card allows the users to load and save Ethernet switch configurations from/into an EEPROM.
The current Ethernet switch configuration can be saved to the EEPROM via a Telnet and/or Modbus TCP/IP
interface. The user can also revert back to the factory default Ethernet switch settings using the Telnet interface.
8.4.3 DHCP Enable/Disable
The 922-MES diagnostics microcontroller (uC DIAG) can obtain its IP address by using the Dynamic Host
Configuration Protocol (DHCP). This feature can be enabled or disabled through the Telnet interface.
If this feature is enabled, then on power up the card sends a DHCP query and waits up to the duration of the
DHCP timeout for a valid response. On receipt of a valid response from a DHCP server, the address specified
by the DHCP response is used as the IP address.
If the card fails to receive a valid DHCP response within the configured timeout period, then the static IP address
saved in the EEPROM is used as the IP address. If the EEPROM access were to fail, the card uses the address
192.168.0.100 as its IP address. Note that by default the DHCP functionality is enabled and the DHCP timeout is 5 minutes (for cards w/ uC DIAG FW 0xA4).
DHCP is enabled by sending one of the following commands through the Telnet interface, “dhcp on short”
or “dhcp on long”or “dhcp on [time in min from 1 to 10]”. These commands will enable DHCP
with a timeout of 1 min, 5 min or 1-10 min respectively. DHCP is disabled by sending “dhcp off”.
Note: Cards with older uC DIAG FW (i.e. <0xA4) P/N 922-1008-01 have DHCP enabled by default with a timeout
of 1 minute and do not support the user-defined timeout range of 1 to 10 min. The only options available in the
older FW versions are 1 or 2 minutes or off.
Focal Technologies CorporationPage 8-5
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 35
Model 922-MES – User Manual
Note that the user has to make sure that they save a valid switch configuration in the EEPROM. Failure
to do so may result in loss of connectivity to the card.
8.4.4 Software Reset
The MES card supports soft resets to the diagnostics microcontroller (uC DIAG) and to the MES switch core for
a full system reset. These soft resets can be applied to the card via Telnet commands.
A uC DIAG soft reset will re-initialize the diagnostics microcontroller interface and peripherals.
An MES switch core soft reset will reset the MES switch. This system reset will re-initialize the MES operating
system and switch fabric and will also re-load the last saved EEPROM configuration. The system reset will cause
an Ethernet link disconnection on all ports of the MES and start a standard boot up sequence that lasts about
1.5 min.
Notes:
1. Any software changes made to the MES not saved in EEPROM will revert back to the last saved state.
2. In the current diagnostics firmware version, an MES switch core reset (Telnet command: bp reboot)
must be followed by a uC DIAG soft reset (Telnet command: reset) 5 sec. (min.) to 10 sec. (max.)
later. Missing this time window will require a power cycle to the card to re-connect to diagnostics.
8.4.5 Watchdog Reset
The card has a built in watchdog timers which are used to trigger a uC DIAG watchdog reset in case of a
diagnostics lock up or to trigger a watchdog reset in case of an MES switch core operating system lock up.
Note: The exact timing parameters of the watchdog reset are beyond the scope of this document.
8.4.6 Automatic User Switch Configuration Loading
The card automatically loads its configuration from EEPROM. The EEPROM is configured at the factory for full
switching functionality. The user can modify most of the factory pre-defined values to accommodate specific
requirements and network topologies.
The initial user configuration of the card can be done via the Telnet interface or via the sample GUI, and changes
can be saved into the EEPROM such that on power up the MES switch core can load its configuration as defined
by the user.
MES cards with uC DIAG firmware 922-1008-00 version ≥ 0xA3
Cards with diagnostics firmware version ≥0xA3 support saving card configuration changes to EEPROM via the
Telnet interface and also via Modbus. EEPROM changes made via Modbus require user confirmation after a
power cycle to take permanent effect, without user confirmation the card will return to the previous state after a
second power cycle. This behavior allows the user a second chance to confirm the full switch functionality of the
card before making them permanent and also allows the user to go back to a previous switch configuration state.
Extended User Switch Configuration
In cases where additional switch settings are needed, the diagnostics microcontroller (uC DIAG) allows the
end-user to automatically load extended switch and system configuration options from EEPROM. This
functionality can be enabled or disabled through the Telnet interface by sending a “scfg on” or “scfg off”
command. If this feature is enabled, then on power-up and after the uC DIAG is running and after the basic
switch configuration is loaded, the card will load the extended switch configuration from the EEPROM after ~40
seconds. By default this option is disabled.
Focal Technologies CorporationPage 8-6
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 36
Model 922-MES – User Manual
UDP Heartbeat Packet Example
“Short” Packet (default)
“Extended” Packet
Model 922-MES Card Information
Serial No : 10052036********
Date Code : 20170530********
Assembly No : 922-5012-99*****
FW VER : A4
FPGA FW VER : 00029B31
MAC ADDRESS : 00-09-CC-08-10-14
LOCAL IP : 192.168.0.100
Subnet : 255.255.255.0
Gateway : 192.168.0.254
Prim DNS : 194.25.2.129
Sec DNS : 194.25.2.130
ON Time : 44 Days 6 Hours
Number of OFF Events : 368
Board Temperature(degC) : 38.12
+5V Supply : 4.91
Board Current(A) : 1.05
Humidity(%) : 18
EEPROM Cfg State : 0x03
IO Buffer Values : 0x3EBC
Auto Reboot Count : 0x00
Model 922-MES Card Information
Serial No : 10052036********
Date Code : 20170530********
Assembly No : 922-5012-99*****
FW VER : A4
FPGA FW VER : 00029B31
MAC ADDRESS : 00-09-CC-08-10-14
LOCAL IP : 192.168.0.100
Subnet : 255.255.255.0
Gateway : 192.168.0.254
Prim DNS : 8.8.8.8
Sec DNS : 8.8.4.4
ON Time : 44 Days 6 Hours
Number of OFF Events : 368
Board Temperature(degC) : 38.12
+5V Supply : 4.91
Board Current(A) : 1.05
Humidity(%) : 18
EEPROM Cfg State : 0x03
IO Buffer Values : 0x3EBC
Auto Reboot Count : 0x00
CU 1 Link : Linked
CU 2 Link : Not Linked
CU 3 Link : Not Linked
CU 4 Link : Not Linked
CU 5 Link : Not Linked
CU 6 Link : Not Linked
CU 7 Link : Linked
CU 8 Link : Not Linked
SFP1 Link : Linked
SFP2 Link : Linked
ECODE0 : 00
ECODE1 : 00
ECODE2 : 00
ECODE3 : 00
8.4.7 UDP Heartbeat Packet
The 922-MES card will continuously transmit a broadcast heartbeat User Datagram Packet (UDP) from uC DIAG
with diagnostics information after power-up and card initialization is completed. The data is printed out as comma
separated text (ASCII) and a network capture utility (e.g. Wireshark) can be used to capture this data. The UDP
heartbeat can be used, for example, to identify cards in cases where the IP information has been lost.
The card can output the UDP heartbeat in two different packet lengths: short (normal) and long (extended). Both
the short and long UDP packet contains the following diagnostics information:
On-board sensors (board temperature, humidity, ON time counter, OFF event counter)
uC DIAG data
o Network settings and configuration (IP address, Subnet Mask, Gateway, DNS, DHCP)
o Analog data (on-board 5V voltage rail and board current)
o Board serial information (including serial number, date code, FW version, MAC address)
The long UDP packet includes all the information from the short packet plus the following diagnostics information:
Link status of copper ports CU1-CU8 and SFP1-SFP2.
Device error codes
By default the UDP heartbeat feature is enabled and the card transmits the short UDP packet every five (5)
seconds. This interval can be adjusted to any value between 1 and 253 seconds through Telnet.
The table below shows an example of the diagnostics information contained in each type of UDP packet. The
heartbeat packet type can be changed through Telnet by sending the command “hcfg long” for extended packets or “hcfg short” for short packets.
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 37
Model 922-MES – User Manual
8.4.8 Multiple Modbus Clients
The MES card provides support for up to four Modbus clients. This feature allows the user to establish more
than one Modbus TCP/IP connection to the same card. When more than one connection is established to the
card, some packet collisions and re-transmission are expected. In general, when using multiple TCP connections
to the same card, it is recommended to set the Modbus poll rate to a value greater than 1 second.
8.4.9 IP Settings for Diagnostics (uC DIAG)
The MES card includes an IP validation feature in the Telnet interface. This feature checks for a valid IP and
subnet combination. If an invalid IP Address is entered using the “set ip” command, the Telnet interface will
show the user the valid range of IP addresses within the current subnet. Additionally, subnet validation will
ensure that the user is providing a valid subnet when using the “set subnet” command. Examples of an
invalid IP entry, a valid IP entry and an invalid subnet entry can be seen in the following figures.
IP validation also occurs during the startup procedure. If on startup an invalid IP address or subnet is read
from the EEPROM, these parameters will be set to the factory defaults.
Figure 8-1: Telnet Invalid IP Entry
Figure 8-2: Valid IP Entry
Figure 8-3: Invalid Subnet Entry
Focal Technologies Corporation Page 8-8
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 38
Model 922-MES – User Manual
Diagnostics Type
Description
Ethernet
Telnet
Modbus
UDP
(long)
UDP
(short)
Ethernet Copper Ports
Link speed status (10/100/1000M)
Link speed configuration (10/100/1000M)
Duplex mode
Autonegotiation state
Ethernet SFP Ports
Link speed (100/1000M)
Link speed configuration (100/1000M)
Redundancy Mode
MRP Status (MRC/MRM SFPs only)
MRP configuration
RSTP Status (Copper ports only)
RSTP configuration
Optical SFP
Optical Tx/Rx power levels, Tx bias current, voltage
and temperature
Analog data (on-board voltage rails and board current)
Board serial information (including serial number, date
code, FW version, MAC address)
9.0 Diagnostics and Control
Remotely accessible, real-time diagnostic data and status information is available from the 922-MES. This
information can be used for real-time health monitoring and long-term trending of critical parameters for
predictive analysis.
Ethernet Diagnostics (Modbus TCP/IP and Telnet): The Ethernet interface provides full diagnostics and
control of the card. Diagnostics and status information are retrievable using Modbus TCP/IP and/or Telnet over
any Ethernet port (copper or SFP).
Configuration options include:
Ethernet port control registers (e.g. forcing speed/duplex, rate limiting, aging, broadcast protection,
port priority, virtual local area network (VLAN) configuration, etc.)
Field update of embedded firmware, and user-controlled switching between stored firmware versions.
Factory Serial Diagnostics (RS-232): The RS-232 serial interface provides basic read-only diagnostics
information via a non-isolated interface (J3). It is intended for factory bench testing and debugging purposes
only. See section 6.6 for details.
Diagnostics information and control provided by the card is shown in the table below.
Table 9-1: Diagnostics Information
Notes:
1. Diagnostics data shown is for cards with uC DIAG FW version ≥0xA3 where = Diagnostics capability available. Blank =
Diagnostics capability not available.
Focal Technologies Corporation Page 9-1
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 39
Model 922-MES – User Manual
9.1 Modbus TCP/IP
The Modbus TCP protocol is used to provide diagnostics and user control messages via a TCP/IP connection
to the 922-MES. Local card status and control registers are accessible via Modbus TCP/IP from the topside or
other subsea equipment over any Ethernet port.
Diagnostic information available is shown in Table 9-1. The Modbus TCP register map is provided in the “MES
The 922-MES card implements a Telnet server on port 23. The server can be accessed from a PC-based Telnet
client such as Microsoft Telnet ClientTM or Tera Term by entering the card’s IP address. Once a connection has
been established, the Telnet interface displays a home screen containing a list of the available commands and
also detailed help on using each command.
Typically the Telnet interface is used for convenient configuration of the card. The commands available in the
Telnet interface are shown in the figure below. Detailed help for each command is available from the Telnet
menu by sending the “help” command. A description of all commands is provided in document 922-0673-02.
Figure 9-1: Telnet Interface Commands
Focal Technologies Corporation Page 9-2
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Page 40
Model 922-MES – User Manual
9.3 Graphical User Interface (GUI)
Focal has created a sample version of a .NET graphical user interface (GUI) for use on Microsoft Windows with
a Modbus TCP backend for integration and bench testing the Model 922 Modbus functionality. Typically users
have or develop their own Modbus TCP interfaces for local PLCs and other controllers. A screenshot of the
sample GUI is shown in the figure below. More information on the use of this software can be found in document
922-0673-01.
Figure 9-2: Sample .NET GUI for Modbus TCP Access to Model 922-MES
Focal Technologies Corporation Page 9-3
A Moog Inc. Company Document No. 922-0662-00, Rev 1.0
Loading...