ACTUATION
ELECTRIC QUARTER-TURN ACTUATORS
FNW offers electric actuators for quarter-turn valves such as ball, plug, and buttery valves. Actuators can be supplied with numerous options including, but not limited to, electro-mechanical brakes (200E and larger), auxiliary position switches, feedback potentiometers, 4-20mA and 0-10Vdc positioners, alternate motor voltages, spring return action, and explosion proof housings. Contact FNW with your specic application needs.
Standard Features
FNW 100E, 200E, 300E, & 400E
• -40°F to 150° Temperature Range (Optional heater required below 0°F)
• CSA Certied Nema 4 Enclosure
• Single 1/2” NPT Conduit Entry
• 300 Series Stainless Steel Output Drive
• 300 Series Stainless Steel Captive Enclosure Fasteners
• ISO Standard Bolting and Drive Dimensions
• Friction Brake Standard
• Non-Declutching Manual Override (400E has Declutching Manual Override Hand Wheel)
• Dome Position Indicator
• Permanently Lubricated
• Mountable in Any Position
• Thermally Bonded Polyester Powder Coated
FNW 600E, 1000E, & 1600E
• -40°F (with Standard Heater Activated) to 140° Temperature Range
• CSA Certied Enclosure Conforms to Nema 1, 2, 3, 3R, 4, 4X, and 12
• Motor Thermal Overload Protection
• Dual 1/2” NPT Conduit Entries
• Heater & Thermostat
• Hardened Steel Spur Gear and Output Drive
• Captive Hex Head Enclosure Fasteners
• ISO Standard Bolting and Drive Dimensions
• Declutching Manual Override with Indicator
• Permanently Lubricated
• Mountable in Any Position
• Polyester Coated
Standard Specications
Output Torque (In-Lbs) 100 200 300 400 600 1000 1600
Cycle Time (Seconds) 2.5 5 5 10 15 15 30
Duty Cycle (120VAC) 25% 25% 25% 25% 30% 100% 100%
Lock Rotor Current (Amps) 0.55A 0.75A 0.99A 0.75A 0.57A 0.69A 0.35A
Weight (Lbs) 6 10 10 18 18 18 18
Standard Specications
Model Number
100E 200E 300E 400E 600E 1000E 1600E
www.fnw.com
1.75
Model 100E Dimensions
0.91
4.72
4.13
1.31
1.97 B.C.
1.42 B.C.
1/2-14 NPT
5.75
2.39
DOME INDICATOR
OVERRIDE
ALLOW 2.5"
CLEARANCE
FOR COVER
1.47
0.25
MANUAL
REMOVAL
2.87
1/4-20 x 0.44 (deep) (x4)
10-24 x 0.44 (deep) (x4)
0.91
5.39
0.43 (0.39 deep)
Model 200E & 300E Dimensions
DOME INDICATOR
MANUAL
OVERRIDE
ALLOW 3" CLEARANCE FOR COVER
REMOVAL
2.43
6.88
0.375
1/2-14 NPT
1.00
2.88
4.25
1.42 B.C.
1.97 B.C.
2.76 B.C.
0.55 (0.63 deep)
5/16-18 x 0.5 (deep) (x4) 1/4-20 x 0.44 (deep) (x4)
10-24 x 0.44 (deep) (x4)
9.03
Model 400E Dimensions
DOME INDICATOR
MANUAL OVERRIDE
PUSH & ROTATE TO ENGAGE
PUSH 2ND TIME TO DECLUTCH
ALLOW 4"
CLEARANCE
FOR COVER
REMOVAL
7.09
2.76 B.C.
1/2-14 NPT
2.81 2.38
7.00
0.67 (0.63 deep)
Model 600E to 1600E Dimensions
0.70
1.76
2.63
7.00
5/16-18 x 0.4 (deep) (x4)
FLAG INDICATOR
MANUAL OVERRIDE
PULL UP & USE
WRENCH ON FLATS
8.00
2.44
1.63
1.63
4.02 B.C.
4.02 B.C.
2.76 B.C.
2.76 B.C.
1/2-14 NPT (x2)
2.50 3.75
9.75
ALLOW 6"
CLEARANCE
FOR COVER
REMOVAL
9.59
3.87
7.75
3/8-16 x 0.60 (deep) (x4)
5/16-18 x 0.50 (deep) (x4)
0.67 (0.75 deep)
Model 100E to 400E Standard Wiring Diagram
Model 600E to 1600E Standard Wiring Diagram
DOC: FNWELECQT05 Ver. 1/2013
© 2013 - FNW. All rights reserved. The FNW logo is a trademark of Ferguson Enterprises, Inc., PL Sourcing, PO Box 2778, Newport News, VA 23609
The contents of this publication are presented for information purposes only, and while ef warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specications of our products at any time without notice. Always verify that you have the most recent product specications or other documentation prior to the installation of these products.