FMI VVCC36N, VC36N, VC36P, VCC36P, VVC36P Owner's Operation And Installation Manual

...
DIRECT-VENT FIREPLACE
P F S
®
USC
OWNER’S OPERATION AND INSTALLATION MANUAL
Patent Pending
NATURAL GAS MODELS (V)VC36N, (V)VCC36N AND CGCDV36NR
SERIES
PROPANE/LP GAS MODELS (V)VC36P, (V)VCC36P AND
CGCDV36PR SERIES
followed exactly, a re or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
— Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com
TAbLE OF CONTENTS
Safety .................................................................. 2
Product Identication ........................................... 4
Local Codes......................................................... 5
Product Features ................................................. 5
Pre-Installation Preparation ................................. 5
Location of Termination Cap ................................ 8
Venting Installation .............................................. 9
Fireplace Installation.......................................... 19
Operation ........................................................... 28
Inspecting Burners............................................. 30

SAFETy

Cleaning and Maintenance ................................ 31
Troubleshooting ................................................. 33
Specications .................................................... 37
Replacement Parts ............................................ 37
Service Hints ..................................................... 37
Technical Service............................................... 37
Parts .................................................................. 38
Accessories ....................................................... 42
Warranty ..............................................Back Cover
WARNING: Improper
installation, adjustment,
alter a tion, s ervice or maintenance can cause
injury or property dam­age. Refer to this manual
for correct installation
and operational proce­dures. For assistance or
additional information consult a qualified in­staller, service agency or
the gas supplier.
This appliance may be in-
stalled in an aftermarket,*
per mane ntly l oca t ed, manufactured (mobile) home, where not prohib­ited by local codes.
This appliance is only for use with the type of gas
indicated on the rating
plate. This appliance is not convertible for use
with other gases, unless
a certied kit is used.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
State of Massachusetts:
The installation must be made by a licensed plumber or gas tter in the Common­wealth of Massachusetts.
WARNING: This product
cont a i n s an d / or generates chemicals known to the State of California to cause cancer or
birth defects or other reproduc­tive harm.
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, op­erate or service this log set. Improper use of this log set can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
This replace must be installed by a qualied (certied or licensed) service person. It has a sealed gas combustion chamber that uses a coaxial pipe (pipe within a pipe and having the same center) venting system. It brings in fresh air for combustion through the outer pipe and combustion gases are exhausted through the inner pipe. If the glass door assembly and venting pipe are not properly seated, con­nected and sealed, carbon monoxide leakage (spillage) can occur.
www.fmiproducts.com
116200-01N2
SAFETy
Continued
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the u, with headaches, dizziness or nausea. If you have these signs, the replace may not be working properly. Get fresh air at once! Have replace serviced. Some people are more affected by carbon monoxide than oth­ers. These include pregnant women, people with heart or lung disease or anemia, those under the inuence of alcohol and those at high altitudes.
Natural and Propane/LP Gas: Natural and propane/LP gas are odorless. An odor-making agent is added to the gas. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this replace.
WARNING: Any change to
this replace or it’s controls can be dangerous. Do not modify this replace under any circum­stances. Any parts removed for servicing must be replaced prior to operating replace.
WARNING: Do not allow fans
to blow directly into the replace. Avoid any drafts that alter burner ame patterns.
Due to high temperatures, the appliance should be located out of trafc and away from furniture and draperies.
Do not place clothing or other ammable material on or near the appliance. Never place any objects on the appliance.
Do not use this replace to cook food or burn paper or other am­mable material.
This replace reaches high tem­peratures. Keep children and
adults away from hot surface to
avoid burns or clothing ignition. Fireplace will remain hot for a time after shutdown. Allow sur­face to cool before touching.
WARNING: Do not use a
blower insert, heat exchanger
insert or other accessory not
Carefully supervise young chil­dren when they are in the room
with replace.
approved for use with this re­place.
Keep the area around your replace clear of combustible
WARNING: This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases unless
a certied kit is used.
116200-01N 3
www.fmiproducts.com
materials, gasoline and other
ammable vapor or liquids. Do not run replace where these are used or stored.
1. For propane/LP replace, do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. capacity.
SAFETy
Continued
2. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in your building
• immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier's instructions
• if you cannot reach you gas supplier, call the re department.
3. Never install the replace
• in a recreational vehicle
• in windy or drafty areas where curtains or other com bus ti ble (fl ammab le) objects can make contact with the replace front
• in high trafc areas
4. Turn fireplace off and let cool before servicing, installing or repairing. Only a qualied service person should install, service or repair this replace. Have re­place inspected annually by a qualied service person.
5. You must keep control compartments, burners and circulating air passages clean. More frequent cleaning may be needed due to excessive lint and dust
from carpeting, bedding material, etc. Turn off the gas valve and pilot light before cleaning replace.
6. Have venting system inspected annually by a qualied service person. If needed, have venting system cleaned or repaired. See Cleaning and Maintenance, page 31.
7. Do not use any solid fuels (wood, coal, paper, cardboard, etc.) in this replace. Use only the gas type indicated on re­place nameplate.
8. This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22.1.
9. Do not use replace if any part has been exposed to or under water. Immediately call a qualied service person to arrange for replacement of the unit.
10. Do not operate replace if any log is broken.
11. Do not operate replace with glass door removed, cracked or broken.
12. Provide adequate clearances around air openings.

PRODUCT IDENTIFICATION

Upper Louver Panel (VC36 Series)
Screen Mesh (VCC36 Series)
Figure 1 - Direct-Vent Fireplace with Millivolt Ignition
Nailing Flange
Glass Door Assembly
Lava Rock
Lower Louver Panel (VC36 Series)
Control Valve with Piezo Ignitor
www.fmiproducts.com
Glowing Embers
Flue Collar
Log Set
Burner Assembly
Switch Bracket for Optional Remote and Blower
116200-01N4
D
RW
FW
Install and use replace with care. Follow all

LOCAL CODES

local codes. In the absence to local codes, use the current National Fuel Gas Code ANSI
Z223.1/NFPA 54* (USA) or the current CSA­B149.1 Installation Code (Canada).

PRODUCT FEATURES

These are a few facts that can help you under­stand and enjoy your direct-vent replace:
• The venting system may be routed to the outside of your home in several ways. It may vent through the roof (vertical) or it may vent to an outside/exterior wall (hori­zontal). The vent pipe installation is very important to allow for proper operation. You must follow the venting instructions very carefully for either vertical or horizontal applications.
• This replace may be installed in any room of your house provided all local codes and these installation instructions are followed.
• This replace requires a wall switch, hand­held remote or wall thermostat (millivolt) for operation (see Accessories, page 42).
• This replace does not require electricity to operate.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
• Only the blower requires electricity if in­stalled and if you plan to install the blower at a later date, do not forget to wire the outlet at the bottom of the replace when framing.
• A piezo ignitor and ceramic electrode cre­ate spark to ignite the pilot light. It does not require any matches, batteries or any other sources of ignition to light the pilot.
• Each time you turn on your replace, you may notice some amount of condensation on the inside of the replace glass. This is normal and will disappear after 10-20 minutes of operation.
• Your dire ct-vent gas fireplace system (replace and venting) is a balanced and sealed gas operating unit. It requires ap­proximately 10-20 minutes of operating time before the ame pattern stabilizes.
• Fireplaces with the sufx of -HA have been designed to operate at altitudes of 4000 feet and above.

PRE-INSTALLATION PREPARATION

LOCATION AND SPACE REQUIREMENTS
Determine the safest and most efcient loca­tion for your FMI PRODUCTS, LLC direct-vent replace. Make sure that rafters and wall studs are not in the way of the venting system. Choose a location where the heat output is not affected by drafts, air conditioning ducts, windows or doors. Figure 2 shows some com­mon locations. Be aware of all restrictions and precautions before deciding the exact location for your replace and termination cap.
When deciding the location of your replace, follow these rules:
• Do not connect this replace venting to a chimney ue serving a separate solid-fuel burning replace or appliance.
• Due to high temperatures, do not locate this replace in high trafc areas, windy or drafty areas or near furniture or draperies.
• Proper clearances must be maintained.
116200-01N 5
www.fmiproducts.com
Figure 2 - Common Fireplace Locations
Figure 3 - Fireplace Bottom Dimensions
Flush with a wall
Through exterior wall enclosed in a chase
Corner installation
29"
21 1/8"
41"
PRE-INSTALLATION PREPARATION
Continued
• If your replace is to be installed directly on carpeting, vinyl tile or any combustible ma­terial other than wood, it must be installed on a metal or wood panel extending the full width and depth of the replace. See Figure 3, page 5.
• Your replace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the back, sides or top of your replace, except where standoff spac­ers are integrally attached. If standoff spac­ers are attached to your replace, these spacers can be placed directly against wall or framing material. See framing details on page 7.
• If you plan on installing a television or enterta in ment center recessed above your replace, it is recommended that you maintain a minimum 18" above top of louver opening.
• When locating termination cap, it is impor­tant to observe the minimum clearances shown in Figure 7, page 8.
• If recessing into a wall, you can avoid extra framing by positioning your replace against an already existing framing member.
• Do not recess termination cap into a wall or siding.
• You may paint the termination cap with 450º F (232º C) heat-resistant paint to coordinate with the exterior nish.
• There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24" from the front of the termination cap.
• Do not locate termination cap where exces­sive snow or ice build up may occur. Be sure to clear vent termination area after snow falls to prevent accidental blockage of venting system. When using snow blowers, do not direct snow towards vent termination area.
• For horizontal installations above 2,000 feet, it is recommended that a 12" extension pipe be added before starter elbow and a round horizontal termination be used (see High Altitude Installation, page 17).
CLEARANCES
Minimum clearances to combustibles for the replace are as follows:
*Back and sides 0" Perpendicular walls 6" Floor 0" Ceiling to louver opening 42" Front 36" Top of Standoffs 0" Vent (See venting instructions
for specic venting clear-
ances.) Combustible material with a maximum thick­ness of 5/8" may be ush with the top front of replace.
* For back and sides of replace, do not pack with insulation or other materials. 0" clear­ance to combustible materials are for framing purpose only.
NOTICE: This replace is in­tended for use as supplemental heat. Use this replace along with your primary heating sys­tem. Do not install this replace as your primary heat source.
If you have a central heating
system, you may run system’s circulating blower while using replace. This will help circulate the heat throughout the house. In the event of a power outage, you can use this replace as a heat source.
FRAMING AND FINISHING
Figure 4 shows typical framing of this replace. Figure 5 shows framing for corner installation. All minimum clearances must be met.
For available accessories for this replace, see Accessories on page 42. If you are using a separate combustible mantel piece, refer to Figure 6 for proper installation height. You can install noncombustible mantels at any height above the replace.
Note: Noncombustible mantels may dis­color!
www.fmiproducts.com
116200-01N6
A
B
E
F
G
H
D
C
Nailing Tabs
C
B
A
D
E
F
G
T o p of Louver
Opening
3
2
1
4
5
6
7
Wa ll
PRE-INSTALLATION PREPARATION
1
36
/8"
1
41
/4"
21" Horizontal Vent
1
/2" Vertical Vent
24
Figure 4 - Framing Clearances for
Installation Against an Exterior Wall
15"
103/8"
35 3/4"
3
/4"
13
41" 41 1/4" 68 1/2"
Figure 5 - Framing Clearances for Corner
Installation
49 5/8"
Continued
Nailing Tabs
Figure 6 - Clearances for Combustible
Mantel from
Ref.
Mantel
Depth Ref.
Top of Louver
Opening
1 14" A 16" 2 12" B 14" 3 10" C 12" 4 8" D 10" 5 6" E 8" 6 4" F 6" 7 2" G 4"
Mantels
116200-01N 7
www.fmiproducts.com
Fixed
Closed
Openable
Fixed
Closed
V
V
V
V
V
V
V
V
X
X
V
X
G
G
J
F
B
B
K
N
H
I
A
N
E
L
D
B
M
A
C
B
V
V
A
G
G
B
TERMINATION CAP
AIR SUPPLY INLET
GAS METERRESTRICTED AREA
(TERMINATION PROHIBITED)
A = clearance above grade, veranda, porch, deck, or balcony [*12" (30.5 cm) minimum] B = clearance to window or door that may be opened [6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US if between 10,000 and 50,000, 12" (30 cm) in Canada if between 10,000 and 100,000; 12" (30 cm) in US if greater than 50,000, 36" (91 cm) in Canada if greater than 100,000] C = clearance to permanently closed window [minimum 12" (30.5 cm) recommended to prevent condensation on window] D = vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24" (61 cm) from the center-line of the terminal [18" (45.7 cm) minimum] E = clearance to unventilated soffit [12" (30.5 cm) minimum] F = clearance to outside corner (see below) G = clearance to inside corner (see below) H = *not to be installed above a meter/regulator assembly within 36" (91.4 cm) horizontally from the center line of the regulator
I = clearance to service regulator vent outlet [*72" (182.9 cm) minimum] J = clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other fireplace [6" (15 cm) min. for 10,000 Btu or less; 9" (23 cm) in US if between 10,000 and 50,000, 12" (30 cm) in Canada if between 10,000 and 100,000; 12" (30 cm) in US if greater than 50,000, 36" (91 cm) in Canada if greater than 100,000] K = clearance to a mechanical air supply inlet [*In Canada, 6 ft. (1.83m) minimum; In US 3 ft. (91 cm) above if within 10 ft. (3 m) horizontally] L = † clearance above paved side-walk or a paved driveway located on public property [*84" (213.3 cm) minimum] M = clearance under veranda, porch, deck [*12" (30.5 cm) minimum ‡] N = clearance above a roof shall extend a minimum of 24" (61 cm) above the highest point when it passes through the roof surface and any other obstruction within a horizontal distance of 18" (45.7 cm)
† vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* ‡ only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor* * as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.
Note: Local codes or regulations may require different clearances
A = 6" (15.2 cm)
Inside Corner
V
B
E
V
B = 6" (15.2 cm)
C = Maximum depth of 48" (121.9 cm) for recessed location D = Minimum width for back wall of recessed location ­ Combustible - 38" (965 mm) Noncombustible - 24" (61 cm) E = Clearance from corner in recessed location­ Combustible - 6" (15.2 cm) Noncombustible - 2" (5.1 cm)
Outside Corner Recessed Location
G
H
G = 12" (30.5 cm) minimum clearance
Balcony with No Side Wall
V
J
Combustible & Noncombustible H = 24" (61 cm) J = 20" (50.8 cm)
Balcony with Perpendicular Side Wall
C
D
C
Termination Clearances for Buildings with Combustible and Noncombustible Exteriors
Openable

LOCATION OF TERMINATION CAP

Figure 7 - Minimum Clearances for Termination Cap
www.fmiproducts.com
116200-01N8

VENTING INSTALLATION

NOTICE: Read these instruc-
tions completely before attempt­ing installation.
These models are tested and approved for use with FMI PRODUCTS, LLC (direct-vent) pipe components and terminations.
The venting system must terminate on the out­side of the structure and can not be attached to a chimney or ue system serving a separate solid fuel or gas burning appliance. A direct-vent appliance must have its own venting system. DO NOT common vent this appliance.
These models are approved to be vented either horizontally through an outside wall or vertically through a roof or chase enclosure using the following guidelines:
• When venting system terminates horizon­tally on an outside wall, you may install a standoff if the termination cap is to be installed directly on a combustible nish such as vinyl, wood, stucco, etc.
• Never run the vent downward as this may cause excessive temperatures which could cause a re.
• Vent pipe air space clearances to com­bustibles are 1" on all sides except on the horizontal sections, which requires 2" clear­ance from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required.
• Snorkel terminations are required when minimum clearance to grade cannot be met (see Figure 16 on page 13).
• Have replace and selected vent compo­nents on hand to help determine the exact measurements when elbowing or offsetting. Always use wall restops when penetrating walls and restops when penetrating ceil­ings or attic spaces.
• If using a venting conguration of only horizontal venting with no vertical run, a 1/4" rise for every 12" of run toward the termination is required.
• For installation of replace at elevations of 4000 feet or greater, pay special attention to venting requirement recommendations.
WARNING: Read all instructions
completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life.
NOTICE: Failure to follow these instructions will void the war-
ranty.
NOTICE: Do not seal termination
cap to vent pipe. Cap must be removable for vent inspection and maintenance.
INSTALLATION PRECAUTIONS
• Wear gloves and safety glasses for pro­tection
• Use extreme caution when using ladders or when on roof tops
• Be aware of electrical wiring locations in walls and ceilings
The following actions will void the warranty on your venting system:
• Installation of any damaged venting com­ponent
• Unauthorized modication of the venting sys­tem (Do not cut or alter vent components)
• Installation of any component part not manufactured or approved by FMI PROD­UCTS, LLC
• Installation other than as instructed by these instructions
WARNING: This gas replace and vent assembly must be vented directly to the outside.
The venting system must NEVER
be attached to a chimney serv­ing a separate solid fuel burning appliance. Each direct-vent gas appliance must use a separate vent system. Do not use com­mon vent systems.
WARNING: Vent pipe air space clearances to combus­tibles are 1" on all sides except
on the horizontal sections,
which require 2" clearances from the top of the pipe. Where the termination cap penetrates a combustible wall, 1" air space clearance is required.
116200-01N 9
www.fmiproducts.com
INSTALLATION PLANNING
(Framing
Detail)
11
1
/2"
(29.2 cm)
11 1/2" Inside Framing
(29.2 cm)
11
1
/2"
(29.2 cm)
8 1/2"
(21.6 cm)
Ve nt Opening
Combustible Wall
Ve nt Opening
Noncombustible Wall
There are two basic types of direct-vent installation:
• Horizontal Termination
• Vertical Termination
Horizontal Termination Installation
IMPORTANT: Horizontal square terminations require only inner portion of wall restop. Hori­zontal installations using round termination require exterior portion of wall restop (see Figure 14, page 12).
1. Set replace in its desired location and determine route your horizontal venting will take. Do not secure replace until all venting has been installed. Some instal­lations require sliding replace in and out of position to make nal venting connec­tions. Figures 14 through 18 on pages 12 through 14 show different congurations for venting with horizontal termination that will help you decide which application best suits your installation. Check to see if wall studs or roof rafters are in the path of your desired venting route. If they are, you may want to adjust location of replace.
2. Direct vent pipe sections and components are designed with special twist-lock con­nections.
Twist-Lock Procedure: Female ends of
pipes have locking lugs (indentations). These lugs will slide straight into match­ing slots on male ends of adjacent pipes. Push pipe sections together and twist one section clockwise approximately one­quarter turn until sections are fully locked (see Figure 8).
Note: Horizontal runs of vent must be sup-
ported every three feet. Use wall straps for this purpose.
3. Use a 45° elbow to connect venting sys­tem to replace ue collar. The elbow is designed to be twist-locked onto ue collar as described in step 2. IMPORTANT: Do not attempt to alter conguration of elbow by cutting, twisting, bending, etc.
4. Assemble desired combination of pipe and elbows to replace ue collar. If there are long portions of venting run, pre­assembled pipe sections may be installed as subassemblies for convenience.
VENTING INSTALLATION
Continued
5. Carefully determine location where vent pipe assembly will penetrate outside wall. Center of hole should line up with center line of horizontal vent pipe. Mark wall for a 11 1/2" x 11 1/2" square hole. Cut and frame square hole in exterior wall where vent will be terminated. If wall being penetrated is constructed of non­combustible material, such as masonry block or concrete, a 8 1/2" hole with zero clearance is acceptable (see Figure 9).
Female Locking Lugs
Figure 8 - Vent Pipe Connections
Figure 9 - Vent Opening Requirements
www.fmiproducts.com
Male Slots
Center of Hole
116200-01N10
VENTING INSTALLATION
Continued
WARNING: Do not recess
vent termination into any wall. This will cause a re hazard.
6. Noncombustible Exterior Wall: Position horizontal vent cap in center of 8 1/2" round hole and attach to exterior wall with four wood screws provided. Before attaching vent cap to exterior wall, run a bead of non-hardening mastic (pliable sealant) around outside edges to make a seal between it and the outside wall.
Note: Four wood screws provided should
be replaced with appropriate fasteners for stucco, brick, concrete or other types of sidings.
Combustible Exterior Wall: For vinyl
siding, stucco or wood exteriors, a siding standoff may be installed between vent cap and exterior wall. Siding standoff prevents excessive heat from damaging siding materials. Siding material must be cut to accommodate standoff. Bolt vent cap to standoff. Apply non-hardening mastic around outside edge of standoff. Position standoff/cap assembly in center
1
of 11
/2" square hole and attach to exte­rior wall with wood screws provided (see Figure 11). Siding standoff must sit ush against exterior fascia material.
7. Connecting Vent Cap with Horizontal Vent Pipe: Slide wall restop over vent pipe before connecting horizontal run to vent cap (see Figure 12).
Carefully move replace, with vent as-
sembly attached, toward wall and insert vent pipe into horizontal termination. Pipe overlap should be a minimum of 1 Figure 13, page 12).
Slide wall restop against interior wall
surface and attach with screws provided. See Figure 13, page 12, for horizontal termination details.
Place replace into position and shim with
noncombustible material if needed. Nail or screw side anges to framing to secure unit in place. IMPORTANT: Make sure re- place is level before securing. If replace is not level it will not work properly.
116200-01N 11
1
/4" (see
www.fmiproducts.com
Figure 10 - Installing Horizontal Vent Cap
(Noncombustible Exterior)
Apply Mastic to All Four Sides
Figure 11 - Installing Siding Standoff
(Combustible Exterior Wall)
Vent Cap (Horizontal Termination)
Screw
Figure 12 - Connecting Vent Cap with
Horizontal Vent Pipe
Apply Mastic to All Four Sides
Vent Cap
Wood Screw
Cut Siding Away to Fit Standoff
Standoff
Wood Screw
Vent Cap
Screws
Interior Wall Surface
Wall Firestop
Horizontal Vent Pipe
VENTING INSTALLATION
Continued
Minimum Pipe Overlap 1
Direct-Vent Pipe
Wall Firestop
Maintain 1" Minimum Air Space Around Outer Pipe When Penetrating a Wall
1
11
/2" x 11 1/2"
Framed Opening
Figure 13 - Typical Horizontal
Termination Cap Mounting with
Additional Siding Standoff Installed
Horizontal Termination Congurations
Figures 14 through 18 show different con­gurations and alternatives for venting with horizontal termination. Each gure includes a chart with critical minimum and maximum dimensions which MUST be met. IMPORTANT: If using a venting conguration of only horizontal venting with no vertical run, a 1/4" rise for every 12" of run toward the termination is required.
1
/4"
Exterior Wall with Vinyl Siding
NOTICE: Do not seal termination
cap to vent pipe. Cap must be removable for vent inspection and maintenance.
Siding Standoff
Screws
High Wind Termination
Apply Mastic to Outside Edge of Standoff
GROUND FLOOR INSTALLATION
Recommended Applications:
• Installation using cabinet surrounds
• Through the wall using round or square termination (up to 12" adjustable pipe)
• NOT FOR CORNER INSTALLATION
Horizontal High Wind Square Termination
45° Elbow
Adjustable Pipe 12" Max.
Wall Firestop
Square Termination
Vertical (V) Horizontal (H)
32 3/4" min. 17" max.
Wall Firestop
45° Elbow
Exterior Portion of Wall Firestop (Round Termination Only)
Horizontal Round Termination
Round
Termination
WARNING: Never run vent
downward as this may cause
excessive temperatures which could cause a re. Operation of improperly installed and main-
tained venting system could
result in serious injury, property damage or loss of life.
www.fmiproducts.com
* If installing this replace at altitudes of 4000 feet and above, it is recommended that an additional vertical height of 6" be added to the vent system.
Figure 14 - Horizontal Termination
Conguration for Square or Round
Terminations
116200-01N12
VENTING INSTALLATION
Continued
CORNER INSTALLATION
Recommended Applications:
• Corner ground oor installation
• Ground oor installation where pipe vents horizontally through wall (over 12" horizon­tal pipe)
• Basement installation where one foot clear­ance from ground to termination is possible
Not to Exceed (H) Limits
Square Termination
90° Elbow
As Required for (V), See Chart for Pipe Section Required
Vertical (V) Vertical Pipe Horizontal (H)
*43 1/2" min. None 30" max.
1
54
/2" min. 1 ft. 48" max.
1
66
/2" min. 2 ft. 60" max.
1
78
/2" min. 3 ft. 84" max.
1
90
/2" min. 4 ft. 20' max.
* Ground Floor Corner Venting
Required
Not to Exceed (H) Limits
90° Elbow
Square Termination
Wall Firestop
Wall Firestop
12" Min.
45° Elbow
45° Elbow
Figure 15 - Horizontal Termination Conguration for Corner Installation Using One
90° Elbow
SNORKEL TERMINATION INSTALLATION
Recommended Applications:
• Installations requiring a vertical rise on building exterior
• Any installation using snorkel termination to achieve one foot above ground
Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building. If installing snorkel termination below grade, you must provide proper drainage to prevent water from entering snorkel termination (see Figure 16). Do not back ll around snorkel termination.
Snorkel Termination
Snorkel Termination
90° Elbow
Snorkel Termination
Wall Firestop
12" Min.
12" Min.
12"
Min.
45° Elbow
Adequate Drainage
Figure 16 - Snorkel Termination Congurations for Below Ground Installation
116200-01N 13
www.fmiproducts.com
VENTING INSTALLATION
Continued
HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS
The following congurations show the minimum vertical rise requirements for a horizontal system using two 90° elbows.
45° Elbow
Venting with Two 90° Elbows
Vertical (V) Horizontal (H
5' min. 2' max. 6' max.
Horizontal (H
)
Horizontal (H
1
6' min. 4' max. 12' max. 7' min. 6' max. 18' max. 8' min. 8' max. 20' max.
20' max. 8' max. 20' max.
Figure 17 - Horizontal Termination Conguration for Venting Using Two 90° Elbows
1
) +
2
)
Venting with Two 90° Elbows
Vertical (V)
5' min. 6' max.
Horizontal (H
Horizontal (H
1
) +
2
)
6' min. 12' max. 7' min. 18' max. 8' min. 20' max.
45° Elbow
20' max. 20' max.
Figure 18 - Horizontal Termination Conguration for Venting Using Two 90° Elbows