SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re­placement parts or accessory items when needed. Keep it with your other important papers.
This replace is approved for use as a wood burning re­place or for use with a vented gas log approved to ANS Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. A FMI PROD­UCTS, LLC hood must be installed when using a vent-free log heater (see , page 18).
This wood burning replace complies with UL127­CAN/ULC-S610-M87 standard as a FACTORY BUILT
APPLIANCE.
FOR CANADA: The authority having jurisdiction (such
as the municipal building department, re department,
etc.) should be contacted before installation to deter­mine the need to obtain a permit.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com
Safety .................................................................. 2
TABLE OF CONTENTS
Specications ...................................................... 3
Fireplace Installation............................................ 4
Venting Installation .............................................. 7
Optional Gas Line Installation............................ 13
SAFETY
Operation and Maintenance .............................. 14
Technical Service............................................... 15
Replacement Parts ............................................ 15
Parts .................................................................. 16
Accessories ....................................................... 18
WARNING: Improper instal­lation, adjustment, alteration, service or maintenance can cause injury, property damage or loss of life. Refer to this manual for assistance or additional in-
formation. Consult a qualied
installer or local distributor.
IMPORTANT: Check local codes
before installing this replace.
Before beginning installation of this replace, read these instructions through completely.
• This FMI PRODUCTS, LLC replace and its components are safe when installed according to this installation manual. Unless you use FMI PRODUCTS, LLC components, which have been designed and tested for the replace system, you may cause a re hazard.
• The FMI PRODUCTS, LLC warranty will be voided by and FMI PRODUCTS, LLC disclaims any responsibility for the following actions.
a. Modification of the fireplace, com-
ponents, doors, air inlet system and damper control.
b. Use of any component part not manufac-
tured or approved by FMI PRODUCTS, LLC in combination with a FMI PROD-
UCTS, LLC replace system. Proper installation is the most important step in ensuring safe and continuous operation of replace. Consult the local building codes as to the particular requirements concerned with the installation of all factory built replaces.
WARNING: Do not install a
replace insert in this box unless
the manufacturer's instructions
with the insert specically state this replace has been tested for
use with this insert.
FOR YOUR SAFETY
• Do not store or use gasoline or any other ammable vapors
or liquids in the vicinity of this or any other appliance.
• Due to high temperatures, the
appliance should be located
out of trafc and away from
furniture and draperies.
• Do not place clothing or other ammable materials on or near
the appliance.
• Never leave children unat­tended when a re is burning in the replace.
WARNING: Use solid wood
or processed solid fuel re logs
only. When processed wood
fuel re logs are used, do not
poke or stir the logs while they
are burning. Use only re logs
that have been evaluated for
the application in replace and refer to re log warnings and
caution markings on packaging prior to use.
This replace is not intended to
be used as a substitute for a fur­nace to heat an entire home. Use for supplemental heat only.
www.fmiproducts.com
109036-01M2
SPECIFICATIONS
1" AIRSPACE TO COMBUSTIBLE MATERIAL
0" TO
TOP SPACERS
3/4" AIR SPACE BACK AND SIDES
OUTSIDE AIR
(LEFT SIDE
ONLY)
0" TO BOTTOM
21.125"
0.625"
12"
EACH SIDE
28.5"
44"
NO COMBUSTIBLE MATERIAL ON FACE
HEARTH EXTENSION 66" X 20"
14"
GAS LINE
KNOCK OUTS
COMBUSTIBLE WALL BOARD
NOT LESS
THAN 14" TO
PERPENDICULAR
SIDEWALL
AIR KIT
KNOCK OUT
10.375"
25.375"
38.85"
RIGHT SIDE
KNOCK OUTS
LEFT SIDE
8.25"
7"
GAS LINE
8.25"
7"
13"
14.438"
1.375"
ROUND TOP TERMINATION
1"
37.5" 33"
6.5"
42"
1"
109036-01M 3
44"
www.fmiproducts.com
21.5"
32"
1.75"
SQUARE CHASE-TOP
TERMINATION
FIREPLACE INSTALLATION
SELECTING LOCATION
To determine safest and most efcient location for replace, you must take into consideration the following guidelines:
1. Location must allow for proper clearances
(see Figures 1 and 2).
2. Consider a location where replace will
not be affected by drafts, air conditioning ducts, windows or doors.
3. A location that avoids cutting of joists or
roof rafters will make installation easier.
4. An outside air kit is available with this
replace (see Optional Outside Air Kit on page 7).
MINIMUM CLEARANCE TO COMBUSTIBLES
Back and sides of replace 3/4" minimum* Floor** 0" minimum Perpendicular wall to opening 12" minimum Top spacers 0" minimum Mantel clearances see Mantels, page 6 Chimney outer pipe surface 1" minimum
* Not required at nailing anges ** See step 2 of Framing
WARNING: Do not pack re­quired air spaces with insulation or other materials.
Minimum/Maximum Chimney Height
Minimum height of chimney, measured from base of replace to ue gas outlet of termina­tion, is 14.5 feet for straight ue or a ue with one elbow set. Maximum distance between elbows is 6 feet. For systems with two elbow sets, minimum height is 22 feet. Maximum height of any system is 50 feet. This measure­ment includes replace, chimney sections and height of termination assembly at level of ue gas outlet (see Figure 18, page 11).
FRAMING
1. Frame opening for replace using dimen­sions shown in Figures 1 and 2.
2. If replace is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood ooring, replace must be installed upon a metal or wood panel extending full width and depth of replace.
3. Set replace directly in front of this open­ing and slide unit back until nailing anges touch side framing.
4. Check level of replace and shim with sheet metal if necessary.
5. Before securing fireplace to prepared framing, ember protector must be placed between hearth extension (not included) and under bottom front edge of replace to protect against glowing embers falling through. If replace is to be installed on a raised platform, a Z-type ember protec­tor (not included) must be fabricated to t your required platform height. Ember protector should extend under replace a minimum of 1 1/2". Ember protector should be made of galvanized sheet metal (28 gauge minimum) to prevent corrosion.
6. Using screws or nails, secure replace to framing through anges located on sides of replace.
37.625"
44.25"
22"
Figure 1 - Framing Dimensions
Maintain 3/4" Clearance at
7
Sides and
/8"
15
Back of
22
52 1/2"
1
/2"
3/4" Clearance Not
Required at Nailing Flanges
72
7
/8"
Fireplace
Figure 2 - Corner Installation
www.fmiproducts.com
109036-01M4
FIREPLACE INSTALLATION
HEARTH EXTENSION
A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of replace opening is required to protect combustible oor construction in front of replace. Fabricate a hearth extension using a material which meets the following specications: a layer of noncombustible, inorganic material having a thermal conductiv­ity of K=0.84 BTU IN/FT, HR. F (or less) at 1" thick. For example, if material selected has a K factor of 0.25, such as glass ber, the following formula would apply:
0.25 x 1.0" = 0.30" thickness required
0.84 Thermal conductivity "K" of materials can be
obtained from manufacturer or supplier of noncombustible material. If hearth extension is to be covered, use noncombustible mate­rial such as tile, slate, brick, concrete, metal, glass, marble, stone, etc. Provide a means to prevent hearth extension from shifting and seal gap between replace frame and hearth extension with a noncombustible material (see Figure 3).
WARNING: Hearth extension
is to be installed only as shown in Figure 3.
Fireplace Front
Ember Protector
Seal Gap
NO
Do Not Block Louver
Extension
Fireplace Front Elevated
Ember Protector
Hearth Extension, Circulating Modes
Fireplace Front
Ember Protector
Fireplace Front Raised Hearth
Ember Protector
Fireplace Front Elevated
Seal Gap
Seal Gap
Extension
Seal Gap
Hearth
Hearth
Ember Protector
Hearth Extension, Noncirculating Models
Figure 3 - Hearth Extension
109036-01M 5
www.fmiproducts.com
FIREPLACE INSTALLATION
Ref.
Continued
MANTELS
A mantel may be installed if desired (see Figure 4). Woodwork such as wood trims, mantels or any other combustible material projecting from front face must not be placed within 12" of replace opening (and within 9" of top louver opening). Combustible materi­als above 12" and projecting more than 1 1/2" from replace must not be placed less than 12" from top opening of replace (NFPA STD 211, Sec. 7-3.3.3).
Mantels or any other combustible material may come up to side edge of black metal face of replace if projection from front face falls within limits shown in Figure 5.
FAN/BLOWER KIT ASSEMBLY
Fan or blower kit is optional with this replace (for circulating models only). Use of blowers or fans other than those manufactured by FMI PRODUCTS, LLC voids warranty. Fan is operated by pressing rocker switch (see Figure 6) in lower right hand corner of replace face. Blower is operated by turning control knob (not shown).
Fan/blower kit electrical connections are made through electrical cover plate on side of replace a shown in Figure 6.
Sheet
Metal
Screws
12 1/4" Ref.
6"
33°
3" Nom.
15"
Min.
12"
Min.
Fireplace Opening
1 Max.
9"
Min.
Top of
Louvered
Opening
1
/2"
Upper Section
Figure 4 - Mantel Clearances to
Combustible Material
FIREBOX
Top View of Fireplace
SAFE ZONE
8"
33°
1"
Min. 12" from
Perpendicular Side Wall
Figure 5 - Side Mantel Clearance
Combustible Material
Safe Zone For Projection of Combustible Materials
*Note: Drawing
Not To Scale
of Circulating
Fireplace
0.625" Max.
Rocker Switch
Electrical Housing
Electrical
Bushing
Wire Nut (3x) (Not Supplied)
Electrical Cover Plate
Outer Wrapper of Fireplace
Power Source Wiring (Not Supplied)
To Power Source
Electrical Cover
Receptacle (Supplied)
Prewired Receptacle and Ground
Plate and Electrical Bushing
Fireplace Chassis Ground
Figure 6 - Fan Switch-Electrical Bushing
Wiring Instructions
1. Remove electrical cover plate with bush­ing from replace by removing 2 sheet metal screws as shown in Figure 6.
2. Slide power source wiring through electri­cal bushing opening and electrical cover plate and make all necessary connec­tions.
3. Slide all wiring connections in electrical housing as shown in Figure 6.
4. Secure electrical cover plate with screws previously removed.
Note: Electrical housing and cover plate have sharp edges. Wear protective gloves.