FMI GWN10A, GWN10TA, GWP10A, GWP10TA, VSHN10M Safety Information And Installation Manual

...
Page 1
VENT-FREE GAS HEATER
PFS
®
US
SAFETY INFORMATION AND INSTALLATION MANUAL
MODELS
GWN10A, GWP10A, GWN10TA, GWP10TA, VSHN10M, VSHP10M,
VSHN10T, VSHP10T
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
— Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
For more information, visit www.fmiproducts.com
Page 2
Safety .................................................................. 2
TABLE OF CONTENTS
Local Codes......................................................... 4
Product Identication ........................................... 4
Unpacking............................................................ 4
Product Features ................................................. 4
Air For Combustion and Ventilation ..................... 5
Installation ........................................................... 7
Operation ........................................................... 13
Inspecting Heater .............................................. 15
SAFETY
Cleaning and Maintenance ................................ 16
Troubleshooting ................................................. 17
Specications .................................................... 21
Replacement Parts ............................................ 21
Service Hints ..................................................... 21
Technical Service............................................... 21
Parts .................................................................. 22
Warranty ..............................................Back Cover
WARNING: Improper
installation, adjustment,
alteration, service or main-
tenance can cause injury or property damage. Refer
to this manual for correct
installation and operation­al procedures. For assis-
tance or additional infor-
mation consult a qualied installer, service agency or the gas supplier.
WARNING: This is an
unvented gas-red heat­er. It uses air (oxygen)
from the room in which
it is installed. Provisions for adequate combustion
and ventilation air must
be provided. Refer to Air for Combustion and Ven­tilation section on page 5
of this manual.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
www.fmiproducts.com
This appliance may be in­stalled in an aftermarket,*
perma n ently locat e d, manufactured (mobile) home, where not prohib­ited by local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
WARNING: This product con-
tains and/or generates chemicals
known to the State of California
to cause cancer or birth defects or other reproductive harm.
IMPORTANT: Read this owner’s manual carefully and completely be for e t rying to assemble, operate or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock and carbon monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning resemble the
u, with headaches, dizziness or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more af­fected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the inu­ence of alcohol and those at high altitudes.
125326-01A2
Page 3
SAFETY
Continued
Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odor­making agent is added to these gases. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.
Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater.
WARNING: Any change to
this heater or its controls can
be dangerous.
WARNING: Do not use a
blower insert, heat exchanger insert or other accessory not ap­proved for use with this heater.
Due to high temperatures, the appliance should be located out of trafc and away from furniture and draperies.
Do not place clothing or other ammable material on or near the appliance. Never place any objects on the heater.
Surface of heater becomes very hot when running heater. Keep
children and adults away from
hot surface to avoid burns or clothing ignition. Heater will
remain hot for a time after shut-
down. Allow surface to cool before touching.
Carefully supervise young chil-
dren when they are in the room
with heater.
Make sure grill guard is in place before running heater.
125326-01A 3
www.fmiproducts.com
Keep the appliance area clear and free from combustible ma­terials, gasoline and other am­mable vapors and liquids.
1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors.
3. Do not install 10,000 Btu units in a bathroom.
4. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not
use any phone in your building
• immediately call your gas supplier from
a neighbor’s phone. Follow the gas sup­plier’s instructions
• if you cannot reach your gas supplier,
call the re department
5. This heater needs fresh, outside air ven­tilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and Ventilation, page 5.
6. Always run heater with control knob at the locked positions or ON position. Never set control knob between locked positions. Poor combustion and higher levels of carbon monoxide may result.
7. Keep all air openings in front and bot­tom of heater clear and free of debris. This will insure enough air for proper combustion.
8. If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.
9. Do not run heater
• where ammable liquids or vapors are used or stored
• under dusty conditions
10. Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furni­ture.
Page 4
11. Do not use heater if any part has been
Control Knob
Ignitor Button
Glass Panel
Front Panel
Heater Cabinet
Grill Guard
under water. Immediately call a qualied service technician to inspect the room
heater and to replace any part of the
control system and any gas control which has been under water.
12. Turn off and let cool before servicing. Only a qualied service person should service and repair heater.
13. Operating heater above elevations of 4,500 feet (1,371 m) could cause pilot outage.
14. To prevent performance problems, do not use propane/LP fuel tank of less than 100 lbs. (45 kg) capacity.
15. Provide adequate clearances around air
openings.
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel
Gas Code ANSI Z223/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
National Fire Protection Association, Inc.
State of Massachusetts: The installa­tion must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.
Sellers of unvented propane or natural gas-red supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
1430 Broadway
New York, NY 10018
Batterymarch Park Quincy, MA 02269
SAFETY
Continued
PRODUCT
IDENTIFICATION
Figure 1 - Vent-Free Gas Heater
(actual heater may vary from illustration
PRODUCT FEATURES
SAFETY DEVICE
This heater has a pilot with an Oxygen Deple­tion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system re­quires no matches, batteries or other sources to light heater.
UNPACkING
1. Remove heater from carton.
2. Remove all protective packaging applied to heater for shipment.
3. Check heater for any shipping damage. If heater is damaged call FMI PRODUCTS,
LLC at 1-866-328-4537 for replacement
parts before returning to dealer.
www.fmiproducts.com
125326-01A4
Page 5
AIR FOR COMBUSTION AND VENTILATION
WARNING: This heater shall
not be installed in a room or space unless the required volume of in­door combustion air is provided by the method described in the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable lo-
cal codes. Read the following in­structions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy efcient than ever. New materials, increased insulation and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. Dur­ing heating months, home owners want their homes as airtight as possible.
While it is good to make your home energy efcient, your home needs to breathe. Fresh air must enter your home. All fuel-burning ap­pliances need fresh air for proper combustion and ventilation.
Exhaust fans, heaters, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel Gas Code. ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classications:
1. Unusually Tight Construction
2. Unconned Space
3. Conned Space
The information on pages 5 through 7 will help you classify your space and provide adequate ventilation.
Unusually Tight Construction
The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation. However, in buildings of un­usually tight construction, you must provide additional fresh air.
Unusually tight construction is dened as construction where:
a. walls and ceilings exposed to the outside
atmosphere have a continuous water vapor retarder with a rating of one perm
-11
(6x10
kg per pa-sec-m2) or less with
openings gasketed or sealed and
b. weather stripping has been added on
openable windows and doors and
c. caulking or sealants are applied to areas
such as joints around window and door frames, between sole plates and oors, between wall-ceiling joints, between wall panels, at penetrations for plumbing,
electrical and gas lines and at other open-
ings.
If your home meets all of the three criteria above, you must provide additional fresh air. See Ven- tilation Air From Outdoors, page 7.
If your home does not meet all of the three criteria above, proceed to Determining Fresh- Air Flow For Heater Location.
Conned Space and Unconned Space
The National Fuel Gas Code ANSI Z223.1/ NFPA 54 denes a conned space as a space
whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the ag­gregate input rating of all appliances installed in that space and an unconned space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the un­conned space.
* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
125326-01A 5
www.fmiproducts.com
Page 6
AIR FOR COMBUSTION AND VENTILATION
Continued
DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION
Determining if You Have a Conned or Unconned Space
Use this work sheet to determine if you have a conned or unconned space.
Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms.
1. Determine the volume of the space (length x width x height).
Length x Width x Height =__________cu. ft.
(volume of space)
Example: Space size 20 ft. (6.1m) (length) x
16 ft. (4.88m) (width) x 8 ft. (2.44 m) (ceiling height) = 2,560 cu. ft. (72.49 m2)(volume of space)
If additional ventilation to adjoining room
is supplied with grills or openings, add the volume of these rooms to the total volume of the space.
2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
________ (volume of space) x 20 = (Maxi-
mum Btu/Hr the space can support)
Example: 2,560 cu. ft. (72.49 m2) (volume of
space) x 20 = 51,200 (maximum Btu/Hr the space can support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free heater _________ Btu/Hr Gas water heater* _________ Btu/Hr Gas furnace _________ Btu/Hr Vented gas heater _________ Btu/Hr Gas heater logs _________ Btu/Hr Other gas appliances* + _________ Btu/Hr Total = _________Btu/Hr * Do not include direct-vent gas appliances.
Direct-vent draws combustion air from the outdoors and vents to the outdoors.
Example:
Gas water heater _________ Btu/Hr Vent-free heater + _________Btu/Hr Total = _________Btu/Hr
4. Compare the maximum Btu/Hr the space can support with the actual amount of Btu/ Hr used.
_______ Btu/Hr (maximum can support) _______ Btu/Hr (actual amount used) Example: 51,200 Btu/ Hr (ma ximum the
space can support)
60,000 Btu/Hr (actual amount of
Btu/Hr used)
40,000 20,000
60,000
www.fmiproducts.com
The space in the example is a conned space because the actual Btu/Hr used is more than the maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an
adjoining room. If the extra space provides an unconned space, remove door to adjoining room or add ventilation grills between rooms. See Ventilation Air From Inside Building.
B. Vent room directly to the outdoors. See
Ventilation Air From Outdoors, page 7.
C. Install a lower Btu/Hr heater, if lower Btu/Hr
size makes room unconned.
If the actual Btu/Hr used is less than the maxi­mum Btu/Hr the space can support, the space is an unconned space. You will need no additional fresh air ventilation.
WARNING: If the area in which
the heater may be operated does not meet the required volume for indoor combustion air, combus­tion and ventilation air shall be provided by one of the methods described in the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code,
or applicable local codes.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconned space. When ventilating to an adjoining unconned space, you must provide two permanent openings: one within 12" (30.5 cm) of the ceiling and one within 12" (30.5 cm) of the oor on the wall connecting the two spaces (see options 1 and 2, Figure 2, page
7). You can also remove door into adjoining room (see option 3, Figure 2, page 7). Follow
the National Fuel Gas Code, ANSI Z223.1/ NFPA 54, Air for Combustion and Ventilation
for required size of ventilation grills or ducts.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" (30.5 cm) of the ceil­ing and one within 12" (30.5 cm) of the oor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the Na-
tional Fuel Gas Code, ANSI Z223.1/NFPA 54,
Air for Combustion and Ventilation for required size of ventilation grills or ducts.
125326-01A6
Page 7
Or
Remove Door into Adjoining
Room,
Option 3
Ventilation Grills
Into Adjoining Room,
Option 2
12"
12"
Ventilation
Grills into Adjoining
Room,
Option 1
Outlet Air
Ventilated Attic
Outlet Air
Inlet Air
Inlet Air
Ventilated
Crawl Space
To
Crawl
Space
To Attic
AIR FOR COMBUSTION AND VENTILATION
Figure 2 - Ventilation Air from Inside
Building
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri­mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
WARNING: A qualied ser­vice person must install heater. Follow all local codes.
CHECK GAS TYPE
Use only the correct gas type (natural or propane/LP) for your unit. If your gas supply is not correct, do not install heater. Call dealer where you bought heater for proper type heater.
Continued
IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat­controlled power vent. Heated air entering the attic will activate the power vent.
Figure 3 - Ventilation Air from Outdoors
WARNING: This appliance is equipped for either natural gas or propane/LP gas but not both. Gas type is indicated on the rating plate. Field conversion is not permitted.
INSTALLATION ITEMS
Before installing heater, make sure you have the items listed below.
• for propane/LP gas, external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• ground joint union
• sediment trap
• tee joint
• pipe wrench
• for natural gas, test gauge connection*
* An equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. The optional equipment shutoff valve can be purchased from your dealer.
125326-01A 7
www.fmiproducts.com
Page 8
INSTALLATION
36" (91.5 cm)
3" (7.7 cm)
FLOOR
CEILING
Minimum
6"
(15.3 cm)
Minimum From Sides Of Heater
Right Side
Left Side
36"
(91.5 cm)
Minimum To
Top Surface Of
Carpeting, Tile Or
Other Combustible
Material
Continued
LOCATING HEATER
This heater is designed to be mounted on a wall.
WARNING: Maintain the
minimum clearances shown
in Figure 4. If you can, provide greater clearances from oor, ceiling and joining wall.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, cloth­ing or other ammable objects are less than 36" (91.5 cm) from the front, top or sides of
the heater
• as a replace insert
• in high trafc areas
• in windy or drafty areas
CAUTION: If you install the
heater in a home garage
• heater pilot and burner must be at least 18" (45.7 cm) above oor
• locate heater where moving
vehicle will not hit it
CAUTION: This heater creates
warm air currents. These currents
move heat to wall surfaces next
to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, to­bacco smoke, aromatic candles, cleaning uids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.
IMPORTANT: Vent-free heaters add mois­ture to the air. Although this is benecial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, page 5.
For convenience and efciency, install heater
• where there is easy access for operation, inspection and service
• in coldest part of room
THERMOSTAT SENSING BULB
(Thermostat Models Only)
The thermostat sensing bulb is located below the heater. Do not move this bulb during instal­lation or operation of the heater.
Figure 4 - Mounting Clearances As
Viewed From Front of Heater
www.fmiproducts.com
125326-01A8
Page 9
INSTALLATION
Mounting
Screw
Locations
8
7
/8"
(22.5 cm)
Minimum To
Maintain 6"
(15.3 cm) Clearance From Wall
FLOOR
JOINING WALL
7 3/4"
(14.7 cm)
20 1/4"
(51.4 cm)
Minimum To
Maintain 3"
(7.7 cm)
Clearance
From Floor
Thin or Thick Wall (thick wall shown)
Solid Wall
1/16" (1.6 mm) Space
Keyhole Slots
Continued
INSTALLING HEATER TO WALL
Marking Screw Locations
WARNING: Maintain minimum
clearances shown in Figure 8. If you can, provide greater clearanc­es from oor and joining wall.
1. Determine where you will locate heater.
2. Mark two mounting screw locations on wall (see Figure 5).
3. Insert wall anchor (wings rst) into hole. Tap anchor ush to wall.
4. For thin walls [1/2" (1.3 cm) or less], insert red key into wall anchor. Push red key to “pop” open anchor wings (see Figure 7).
IMPORTANT: Do not hammer key! For
thick walls [over 1/2" (1.3 cm) thick] or solid walls, do not pop open wings.
5. Tighten two screws until 1/16" (1.6 mm) space (thickness of penny) is between screwheads and wall (see Figure 8).
Figure 6 - Folding
Anchor
Figure 7 - Popping
Open Anchor Wings
for Thin Walls
Figure 5 - Mounting Screw Locations
Installing Two Mounting Screws
Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater.
Attaching To Wall Stud Method
For attaching mounting bracket to wall studs
1. Drill holes at marked locations using 9/64" drill bit.
2. Insert mounting screws into wall studs.
3. Tighten screws until 1/16" (1.6 mm) space
Figure 8 - Tightening Anchors
Placing Heater On Mounting Screws
1. Locate two keyhole slots on back panel of heater (see Figure 9).
2. Place large openings of slots over scre­wheads. Slide heater down until screws are in small portion of slots.
(thickness of penny) is beween screw­head and wall.
Attaching to wall anchor method
Follow instructions below to attach mounting screws to hollow walls (wall areas between studs) or solid walls (concrete or masonry).
1. Drill holes at marked locations using 5/16"
2. Fold wall anchor (see Figure 6).
125326-01A 9
drill bit. For solid walls (concrete or ma­sonry), drill at least 1 1/4" (3.2 cm) deep.
www.fmiproducts.com
Figure 9 - Location Of Keyhole Slots On
Back Panel Of Heater
Page 10
INSTALLATION
Continued
Removing Front Panel Of Heater
1. Remove two screws near bottom corners of front panel.
2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4".
3. Pull bottom of front panel forward, then down.
Figure 10 - Removing Front Panel Of
Heater
Installing Bottom Mounting Screw
1. Locate bottom mounting hole. This hole is near bottom on back panel of heater (see Figure 11).
2. Mark screw location on wall.
3. Remove heater from wall.
4. If installing bottom mounting screw into hollow or solid wall, install wall anchor. Follow steps 1 through 5 under Attaching To Wall Anchor Method, page 9. If install­ing bottom mounting screw into wall stud, drill hole at marked location using 9/64" drill bit.
5. Replace heater on wall.
6. Insert bottom anchor screw through back
panel into bottom anchor or drilled hole
(see Figure 11).
7. Tighten screw until heater is rmly se­cured to wall. Do not over tighten.
Note: Do not replace front panel at this
time. Replace front panel after making gas connections and checking for leaks (see pages 10 through 13).
Figure 11 - Installing Bottom Mounting
Screws
www.fmiproducts.com
CONNECTING TO GAS SUPPLY
WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.
WARNING: A qualied service person must connect heater to gas supply. Follow all local codes.
WARNING:
For natural gas, never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.
IMPORTANT: For natural gas, check gas line pressure before connecting heater to gas line. Gas line pressure must be no greater than
10.5" W.C.. If gas line pressure is higher, heater regulator damage could occur.
CAUTION: For propane/LP gas, never connect heater di­rectly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply.
For propane/LP gas, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11" and 14" W.C.. If you do not reduce incoming gas pres­sure, heater regulator damage could occur. Install the external regulator with the vent pointing down as shown in Figure 12, page 11. Pointing the vent down protects it from freezing rain or sleet.
CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of large enough diameter to allow proper gas vol­ume to heater. If pipe is too small, undue loss of volume will occur.
125326-01A10
Page 11
Installation must include equipment shutoff
Cap Pipe Te e Nipple Joint
Tee Joint
Reducer Bushing to 1/8" NPT
1/8" NPT Plug Ta p
Pressure Regulator
Test Gauge Connection*
Heater Cabinet
Sediment Trap
Equipment Shutoff Valve *
3" Min.
Ground Joint Union
3/8" NPT Pipe Nipple
Natural Gas
From Gas Meter (7" W.C. to 10.5" W.C. Pressure)
Propane/LP
From External Regulator (11" W.C. to 14" W.C. Pressure)
valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).
IMPORTANT: Install an equipment shutoff valve in an accessible location. The equip­ment shutoff valve is for turning on or shutting off the gas to the appliance.
Check your building codes for an special requirements for locating equipment shutoff valve to heater.
Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.
sealant that is resistant to liquid petroleum (LP) gas.
Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sediment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.
IMPORTANT: Hold the pressure regulator with wrench when connecting it to gas pip­ing and/or ttings. Do not over tighten pipe connection to regulator. The regulator body could be damaged.
Propane/LP Supply Tank
Figure 12 - Equipment Regulator with
125326-01A 11
INSTALLATION
Continued
WARNING: Use pipe joint
External
Regulator with Vent
Pointing
Down
Vent Pointing Down
www.fmiproducts.com
Figure 13 - Gas Connection
* An equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional equipment shutoff valve from your dealer.
Page 12
INSTALLATION
Equipment Shutoff Valve
Propane/LP Supply Tank
Thermostat Gas Valve
Equipment Shutoff Valve
Gas Meter
Thermostat Gas Valve
CHECKING GAS CONNECTIONS
WARNING: Test all gas piping
and connections, internal and external to unit, for leaks after
installing or servicing. Correct all leaks at once.
WARNING: Never use an
open ame to check for a leak. Apply a noncorrosive leak detec­tion uid to all joints. Bubbles forming show a leak. Correct all leaks at once.
Continued
2. Pressurize supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.
3. Check all joints from gas meter for natural gas (see Figure 16)) or propane/LP supply tank for propane/LP to equipment shutoff valve (see Figure 15 or 16). Apply a non­corrosive leak detection uid to all joints. Bubbles forming show a leak.
4. Correct all leaks at once.
Equipment Shutoff Valve
Open
PRESSURE TESTING GAS SUPPLY PIPING SYSTEM
Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)
1. Disconnect appliance with its appliance
2. Cap off open end of gas pipe where equip-
3. Pressurize supply piping system by either
4. Check all joints of gas supply piping system.
5. Correct all leaks at once.
6. Reconnect heater and equipment shutoff
Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see Fig-
CAUTION: For propane/LP units, make sure external regula­tor has been installed between propane/LP supply and heater. See guidelines under Connecting to Gas Supply, page 10.
main gas valve (control valve) and equip­ment shutoff valve from gas supply piping. Pressures in excess of 1/2 psig will dam­age heater regulator.
ment shutoff valve was connected.
opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas or using compressed air.
Apply a commercial leak detection solution to all joints. Bubbles forming show a leak.
valve to gas supply. Check reconnected ttings for leaks.
ure 14).
www.fmiproducts.com
Closed
Figure 14 - Equipment Shutoff Valve
Figure 15 - Checking Gas Joints for
Natural Gas (actual heater may vary from
illustration)
Figure 16 - Checking Gas Joints for
Propane/LP Gas (actual heater may vary
from illustration)
125326-01A12
Page 13
INSTALLATION
Continued
PRESSURE TESTING HEATER GAS CONNECTIONS
1. Open equipment shutoff valve (see Figure
15).
2. For natural gas, open main gas valve lo­cated on or near gas meter. For propane/ LP gas, open propane/LP supply tank valve.
3. Make sure control knob of heater is in the OFF position.
4. Check all joints from equipment shutoff valve to thermostat gas valve (see Figure 16 or 17). Apply a noncorrosive leak de­tection uid to all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operation page 15). Check all other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appliance, page 16).
8. Replace front panel.
OPERATION
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a re or explosion may result causing property damage, per­sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next to the oor because some gas is
heavier than air and will settle on the
oor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas sup­plier’s instructions.
• If you cannot reach your gas supplier, call the re department.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualied service technician or gas supplier. Force or attempted repair may result in a re or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a qualied service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
125326-01A 13
www.fmiproducts.com
1. STOP! Read the safety information above.
2. Make sure equipment shutoff valve is fully open.
3. Turn off any electric power to the appliance if service is to be performed.
4. Turn control knob clockwise to the OFF position.
5. Wait ve (5) minutes to clear out any gas. Then smell for gas, including near the oor. If you smell gas, STOP! Follow “B” in the safety information, column 1. If you don’t smell gas, go to the next step.
6. Turn control knob counterclockwise to the PILOT position. Press in control knob for ve (5) seconds.
7. With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. Note: You may be running this heater for the rst time after hooking up to gas supply. If so, you may need to press in control knob for 30 seconds or more. This will allow air to bleed from the gas system. If needed, keep pressing ignitor button until pilot lights. If ignitor does not light pilot, refer to Troubleshooting, page 17 or contact a qualied service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 14.
8. Keep control knob pressed in for 30 sec­onds after lighting pilot. After 30 seconds, release control knob.
• If control knob does not pop out when released, contact a qualied service person or gas supplier for repairs.
LIGHTING
INSTRUCTIONS
Page 14
Control Knob
O
O
T
Control Knob
Note: If pilot goes out, repeat steps 4
Thermocouple
Ignitor Electrode
Pilot Burner
9. Turn control knob counterclockwise
10. To shut off burners only and leave pilot lit,
manual control heaters at the
locked positions. Operation between these positions may create a possible health hazard if used in a poorly ventilated room. Read owner’s manual for complete instructions.
Figure 19 - Pilot (actual pilot may vary)
just heating levels by using the equipment shutoff valve.
OPERATION
Continued
through 7. Wait one (1) minute before light­ing pilot
to desired heating level. The main burner should light.
turn control knob clockwise to the PILOT position.
WARNING: Always operate
Figure 17 - Control Knob in the OFF
Position for Manual Control Models
Figure 18 - Control Knob in the OFF
Position for Thermostat Models
CAUTION: Do not try to ad-
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise to the OFF position.
2. Turn off all electric power to the appliance if service is to be performed.
2. Close equipment shutoff valve (see Figure 15, page 13).
MANUAL LIGHTING
PROCEDURE
1. Remove front panel (see Figure 6, page 9).
2. Follow steps 1 through 5 under Lighting Instructions, page 15.
3. With control knob pressed in, strike match. Hold match to pilot until pilot lights.
4. Keep control knob pressed in for 30 sec­onds after lighting pilot. After 30 seconds, release control knob. Now follow step 9 under Lighting Instructions, page 15.
5. Replace front panel.
THERMOSTAT CONTROL
OPERATION
Thermostat models only
The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any comfort level between 1 and 5. All plaques will turn off and on.
Note: The thermostat sensing bulb mea­sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation location, room size, open air temperatures, etc.) Frequent use of your heater will let you determine your own comfort levels.
www.fmiproducts.com
125326-01A14
Page 15
1
/2 Glass
Height
1
/2 Glass
Height
Blue Flame
Yellow Tipping
1
/2 Glass
Height
Yellow Tipping
INSPECTING HEATERS
Thermocouple
Pilot Burner
Pilot Burner
Thermocouple
Blue Flame
Yellow Flame
Check pilot ame pattern and burner ame patterns often.
PILOT FLAME PATTERN
Figure 20 shows a correct pilot ame pattern. Figure 21 shows an incorrect pilot ame pat­tern. The incorrect pilot ame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.
If pilot ame pattern is incorrect, as shown in Figure 21
• turn heater off (see To Turn Off Gas to Ap- pliance, page 14)
• see Cleaning and Maintenance, page 16
Note: The pilot ame on natural gas units will
have a slight curve, but ame should be
blue and have no yellow or orange color.
Figure 20 - Correct Pilot Flame Pattern
BURNER FLAME PATTERN
WARNING: If yellow tipping occurs, your heater could pro­duce increased levels of carbon monoxide.
NOTICE: Do not mistake orange ames with yellow tipping. Dirt or other ne particles enter the heater and burn causing brief patches of orange ame.
Figure 22 shows a correct burner ame pattern. Figure 23 shows an incorrect burner ame pat­tern. The incorrect burner ame pattern shows yellow tipping of the ame. It also shows the ame higher than 1/2 the glass panel height.
If burner ame pattern is incorrect, as shown in Figure 23
• turn heater off (see To Turn Off Gas to Ap- pliance, page 14)
• see Cleaning and Maintenance, page 16
Figure 21 - Incorrect Pilot Flame Pattern
125326-01A 15
Figure 22 - Correct Burner Flame Pattern
Figure 23 - Incorrect Burner Flame
Pattern
www.fmiproducts.com
Page 16
CLEANING AND MAINTENANCE
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep control areas, burner and circu­lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualied service person. Heater may need more frequent clean­ing due to excessive lint from carpeting, bedding material, pet hair, etc.
WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.
ODS/PILOT AND BURNER
Use a vacuum cleaner, pressurized air or small, soft bristled brush to clean.
BURNER PILOT AIR INLET
The primary air inlet holes allow the proper amount of air to mix with the gas. This pro­vides a clean burning ame. Keep these holes clear of dust, dirt and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a qualied service person.
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store or
home center may carry compressed air in a
can. If using compressed air in a can, please follow the directions on the can. If you don’t follow directions on the can, you could dam­age the pilot assembly.
1. Shut off unit, including pilot. Allow unit to cool for at least thirty minutes.
2. Inspect burner, pilot and primary air inlet holes on orice holder for dust and dirt (see Figure 26).
3. Blow air through the ports/slots and holes in the burner.
4. Never inset objects into the pilot tube.
5. Blow air into the primary air holes on the orice holder.
Clean pilot assembly also. A yellow tip on the pilot ame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about 2" from where the pilot ame comes out of the pilot assembly (see Figure 26). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
Pilot Assembly
Pilot Air
Inlet Hole
Figure 26 - Pilot Inlet Air Hole
CABINET
Air Passageways
Use pressurized air to clean.
Exterior
Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to re­move dust.
www.fmiproducts.com
125326-01A16
Page 17
TROUBLESHOOTING
WARNING: Turn off and unplug heater and let cool before servicing.
Only a qualied service person should service and repair heater.
CAUTION: Never use a wire, needle or similar object to clean
ODS/pilot. This can damage ODS/pilot unit.
Note: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM
Whe n i g n i t or butt o n i s pressed, there is no spark at ODS/pilot
POSSIBLE CAUSE
1. Ignitor electrode positioned wrong
2. Ignitor electrode broken
3. Ignitor electrode not con-
nected to ignitor cable
4. Igni tor cable pinched or wet
5. Broken ignitor cable
6. Bad piezo ignitor
REMEDY
1. Replace pilot assembly
2. Replace pilot assembly
3. Reconnect ignitor cable
4. Free ignitor cable if pinched by any metal or tubing. Keep
ignitor cable dry
5. Replace ignitor cable
6. Replace piezo ignitor
When ignitor button is pressed in, there is a spark at ODS/Pilot but no ignition
1. Gas supply turned off or equipme nt shu to ff valve
closed
2. Control knob is not in pilot
position
3. Cont r o l knob n o t ful l y pressed in while pressing ignitor button
4. Air in gas lines when in-
stalled
5. Depleted gas supply (pro­pane/LP gas)
6. ODS/pilot is clogged
7. Gas regulator setting is not
correct
1. Turn on gas supply or open equipment shutoff valve
2. Turn control knob to pilot
position
3. Turn to PILOT/IGN posi­tion. Fully press in control knob while pressing ignitor button
4. Cont inu e holdi ng do wn control knob. Repeat ignit­ing ope ra ti on until a ir is removed
5. Contact local propane/LP
gas company
6. Clean ODS/pilot (see Clean­ing and Maintenance, page
16) or replace ODS/pilot
assembly
7. Replace gas regulator
125326-01A 17
www.fmiproducts.com
Page 18
OBSERVED PROBLEM
ODS/pilot lights but flame goes out when control knob
is released
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Cont r ol kn o b not f ully
pressed in
2. Control knob not pressed in long enough
3. Equipment shutoff valve not fully open
4. Pilot flame not touchi ng thermocouple, which al­lows thermocouple to cool, causing pilot ame to go out. This problem could be caused by one or both of the following:
A) Low gas pressure B) Dirty or partially clogged
ODS/pilot
5. Thermocouple connection loose at control valve
6. Thermocouple damaged
7. Control valve damaged
REMEDY
1. Press in control knob fully
2. After ODS/pilot lights, keep control knob pressed in 30
seconds
3. Fully open equipment shut­off valve
4. A) Contact local natural or propane/LP gas company
B) Clean ODS/pilot (see
Cleaning and Maintenance, page 16) or replace ODS/
pilot assembly
5. Hand tighten until snug, then tighten 1/4 turn more
6. Replace pilot assembly
7. Replace control valve
Burner does not light after ODS/pilot is lit
Delayed ignition of burner
Burner backring during com­bustion
1. Burner orice clogged
2. Inlet gas pressure is too low
1. Manifold pressure is too low
2. Burner orice clogged
1. Burner orice is clogged or
damaged
2. Damaged burner
3. Gas regulator defective
1. Clean burner (see Cleaning and Maintenance, page 16) or replace burner orice
2. Contact loca l natural or propane/LP gas company
1. Contact loca l natural or propane/LP gas company
2. Clean burner (see Cleaning and Maintenance, page 16) or replace burner orice
1. Clean burner (see Cleaning and Maintenance, page
16)
2. Replace burner
3. Replace gas regulator
www.fmiproducts.com
125326-01A18
Page 19
OBSERVED PROBLEM
Yellow ame during burner combustion
TROUBLESHOOTING
Continued
POSSIBLE CAUSE
1. Not enough air
2. Gas Regulator defective
3. Clogged or dirty burner
REMEDY
1. Clean burner (see Cleaning and Maintenance, page 16)
or replace burner orice
2. Replace damaged burner
3. Replace gas regulator
Slight smoke or odor during
initial operation
Heater produces a clicking/ ticking noise just after burner is lit or shut off
White powder residue forming within burner box or on adja­cent walls or furniture
Heater produces a whistling noise when burner is lit
1. Residues from manufactur-
ing processes
1. Met al exp a ndi ng whi l e heating or contracting while
cooling
1. When heated, vapors from furniture polish, wax, carpet cleaner, etc., may turn into white powder residue
1. Turning control knob to po­sition when burner is cold
2. Air in gas line
3. Air passageways on heater blocked
4. Dirty or partially clogged burner orice
1. Problem will stop after a few hours of operation
1. This is normal with most heat­ers. If noise is excessive, con­tact qualied service person
1. Turn heater off when using
furniture polish, wax, carpet
cleaners or similar products
1. Turn control knob to 1 posi­tion and let warm up for a minute.
2. Operate burner until air is removed from line. Have gas line checked by local natural or propane/LP gas company
3. Observe minimum installa­tion clearances (see Figure 4, page 8)
4. Clean burner (see Cleaning and Maintenance, page 16) or replace burner orice
125326-01A 19
www.fmiproducts.com
Page 20
TROUBLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Fol­low the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the re department.
IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning sup­plies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.
OBSERVED PROBLEM
Heater produces unwanted
odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF position
Gas odor during combustion
Moisture/condensation no­ticed on windows
POSSIBLE CAUSE
1. Heater burning vapors from paint, hair spray, glues, etc. See IM- PORTANT statement above
2. Low fuel supply (propane/ LP gas only)
3. Gas leak. See Wa rning
statement at top of page
1. No t en ou gh fre sh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See Wa rning
statement at top of page
2. Control valve defective
1. Foreign matter between control valve and burner
2. Gas leak. See Wa rning
statement at top of page
1. Not enough combustion/ ventilation air
REMEDY
1. Ventilate room. Stop using odor causing products while
heater is running
2. Rell supply tank
3. Locate and correct all leaks (see Checking Gas Connec- tions, page 12)
1. Open window and/or door for ventilation
2. Contact local natural or pro­pane/LP gas company
3. Clean ODS/pilot (see Cleaning and Maintenance, page 16)
1. Locate and correct all leaks (see Checking Gas Connec- tions, page 12)
2. Replace control valve
1. Take apart gas tubing and remove foreign matter
2. Locate and correct all leaks (see Checking Gas Connec- tions, page 12)
1. Refer to Air for Combustion and Ventilation requirements (page 5)
www.fmiproducts.com
125326-01A20
Page 21
SPECIFICATIONS
GWN10A, VSHN10M
• Natural Gas Only
• 5,500/10,000 Btu/h
• Piezo Ignition
• Pressure Regulator Setting: 3" W.C.
• Inlet Gas Pressure* (in. of water): Maximum - 10.5" W.C., Minimum - 4" W.C.
GWN10TA, VSHN10T
• Natural Gas Only
• 5,000/10,000 Btu/h
• Piezo Ignition
• Pressure Regulator Setting: 3" W.C.
• Inlet Gas Pressure* (in. of water): Maximum - 10.5" W.C., Minimum - 4" W.C.
REPLACEMENT PARTS
Note: Use only original replacement parts. This will protect your warranty coverage for
parts replaced under warranty.
Contact authorized dealers of this product. If they can’t supply original replacement pa r t(s ), ca l l FMI PR ODU CTS , LLC at 1-866-328-4537.
GWP10A, VSHP10M
• Propane/LP Gas Only
• 5,500/10,000 Btu/h
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure* (in. of water): Maximum - 14" W.C., Minimum - 11" W.C.
GWP10TA, VSHP10A
• Propane/LP Gas Only
• 5,000/10,000 Btu/h
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure* (in. of water): Maximum - 14" W.C., Minimum - 11" W.C.
When calling, have ready:
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the factory.
TECHNICAL SERVICE
You may have further questions about installa­tion, operation or troubleshooting. If so, contact FMI PRODUCTS, LLC at 1-866-328-4537. When calling please have your model and serial numbers of your heater ready.
You can also visit our web site at www.fmiproducts.com.
125326-01A 21
www.fmiproducts.com
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specied heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, contact your local natural or propane/LP gas supplier.
SERVICE HINTS
Page 22
PARTS
1
2
3
4*
5
6
7*
8*
9*
10
11
12
13
14
15
16
17
18
19
20
4**
9**
7**
8**
*Manual Models **Thermostat Models
MODELS GWN10A, GWP10A, GWN10TA, GWP10TA, VSHN10M, VSHP10M, VSHN10T, VSHP10T
www.fmiproducts.com
125326-01A22
Page 23
This list contains replaceable parts used in your heater. When ordering parts, follow the
PARTS
instructions listed under Replacement Parts on page 21 of this manual.
KEY
NO. PART NO. DESCRIPTION
GWP10TA
VSHP10T
GWN10TA
VSHN10T
GWP10A
VSHP10M
GWN10A
VSHN10M QTY.
1 099217-02CP Front Panel 1 2 098271-03 Ignitor Cable 1 3 097159-04 Piezo Ignitor 1 4 099413-01 Control Valve 1
099413-02 Control Valve 1
098522-11 Control Valve 1
098522-18 Control Valve 1 5 098508-01 Valve Nut Retainer 1 6 099393-02 Control Knob 1 7 099462-01 Burner Tube 1
104261-01 Burner Tube 1 8 099391-02 Regulator Tube 1
104264-01 Inlet Tube 1 9 099387-17 Pilot Tube 1
099387-11 Pilot Tube 1 10 099317-02 Deector 1 11 NJF 8C Hex Nut 1 12 104259-01 Orice 1
104259-02 Orice 1 104259-05 Orice 1
104259-06 Orice 1 13 104263-03 Burner 1 14 120630-03 ODS/Pilot 1
120630-02 ODS/Pilot 1 15 099318-04 Grill Guard 1 16 099319-02 Top Glass Retainer 1 17 098260-11 Glass Panel 1 18 102017-02 Bottom Glass Retainer 1 19 099415-17 Gas Regulator 1
099415-18 Gas Regulator 20 ** Cabinet Assembly 1
PARTS AVAILABLE - NOT SHOWN
100642-02 Hardware Assembly 1
125332-01 Lighting Instruction 1
125333-01 Control Position Decal 1
107888-06 Control Position Decal 1
099123-01 Thermobulb Clip 1
** Not a eld replaceable part.
125326-01A 23
www.fmiproducts.com
Page 24
WARRANTY
kEEP THIS WARRANTY
Model (
located on product or identication tag
Serial No. (
located on product or identication tag
Date Purchased __________________________
Keep receipt for warranty verication.
FMI PRODUCTS, LLC LIMITED WARRANTIES
Standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects in material and workmanship for a period of four (4) years from the date of rst purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date of rst purchase.
Limited Warranty: FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be free from defects in material and workmanship for 30 days from the date of rst purchase from an authorized dealer provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s warnings and instructions.
The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under this warranty the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only when installed by a qualied installer in accordance with all local codes and instructions furnished with this product.
This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allow­ance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement parts voids this warranty.
Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper installation, lack of proper maintenance, tampering, or alteration(s).
This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all implied warranties, including warranties of merchantability and tness for a particular purpose to four (4) years on new products and 30 days on factory reconditioned products from the date of rst purchase. FMI PRODUCTS, LLC makes no other warranties regarding this product.
FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specic legal rights, and you may also have other rights which vary from state to state.
For information about this warranty contact:
Factory Reconditioned Products
Terms Common to All Warranties
) _____________________________
) __________________________
New Products
2701 S. Harbor Blvd.
Santa Ana, CA 92704
1-866-328-4537
www.fmiproducts.com
125326-01
Rev. A 05/10