FMI CL1 User Manual

OVERVIEW: Congratulations. Your Chloritrol® CL System from
Fluid Metering Inc. is the newest patented innovation in 50 years for accurate, low maintenance injection of sodium hypochlorite for water and wastewater treatment. FMI’s CL, along with it’s CTS Chemical Treatment System for caustic soda, are the easiest chemical feed systems for water and waste treatment in the world.
The patented Chloritrol® CL & CTS systems eliminate check valves and/or peristaltic tubing typically present in traditional hypochlorite metering systems, which are the primary sources of downtime and frequent maintenance . The CL & CTS Systems will never lose prime, even against pressure, or air lock. The Chloritrol
®
CL system consists of the CL Pump
Module and C100A Variable Speed Controller.
The CL Pump Module is a unique valveless duplex
FMI CeramPump® and an FMI RO “sipper” pump direct coupled to a single variable speed drive motor. The high-pressure CeramPump® injects the hypochlorite directly into the main water stream, while the RO “sipper” pump removes any gas generated because of chlorine out-gassing, eliminating “gas lock” and/or loss of prime.
CHLORITROL® CL with C100A
Liquid Hypochlorite Injection System
INSTALLATION & OPERATING INSTRUCTIONS
IN-CL-14
3/11/14 HW
The C100A Variable Speed Controller from Fluid
Metering, Inc. is specifically designed to interface
with the Chloritrol® CL Pump Module. This
controller provides a variable 0-90 VDC power source, which is controlled either manually using a panel mounted rotary dial, or electronically via a 4-20 mA control input.*
* Other commercially available controllers may work, however we
recommend contacting FMI for details.
Page 1 of 10
Chloritrol® CL Pump Module
and C100A Variable Speed Controller
Supply Voltage: 0-90 VDC (Supplied by C100A Controller)
CL Supply: 1/4” NPT female CL Recirculation return: 1/4” NPT female CL High Pressure outlet: 1/4” NPT female
Output Volume: CL1: 6.5 GPH max. CL2: 15 GPH max. Output Pressure: 125 psi max.
Environment: Humidity: 100% RH non-condensing Temp: non-freezing to 104°F
Enclosure: Fiberglass Dimensions: 15 1/2” x 13 3/8” x 6 3/4”
Weight: 18.6 lbs. (8.4 kg.)
CL SPECIFICATIONS
CL INSTALLATION & SETUP
The Chloritrol® CL prefers to “lift fluid” and therefore should be located a minimum of 12 inches above supply vessel. It should also be mounted in an accessible location where the cover can be opened freely. Diagram 5 illustrates the recommended mounting location, as well as a typical system configuration.
MOUNTING
Securely fasten the CL to a wall location with its right side convenient to the hypochlorite supply vessel. There are 4 mounting holes (5/16” dia) on each side of the CL enclosure. Utilize at least 2 holes on each side for most secure mounting. Diagram 1 (left) shows the mounting hole locations.
Diagram 2
(Right Side)
Diagram 3
(Left Side)
ELECTRICAL
On the upper left side of the Chloritrol® CL enclosure is a 7/8” conduit opening for the electrical supply (0-90 VDC source from the C100A or FMI approved customer supplied voltage controller).
Note: See page 5 “Wiring Procedure” for additional information regarding wire sizing.
1. With the power off, and the manual speed dial
turned fully counterclockwise to the “0” position, connect the C100A to the 120 VAC power source.
2. Connect the C100A Variable Speed DC Controller
to the Chloritrol® using 3 conductor cable.
3. If electronic speed control is being used, connect
the 4-20 mA source (typically a sensor or analyzer), to the 4-20 mA input of the C100A.
Diagram 4
Terminal Wiring
IMPORTANT NOTE: There are two (2) vent holes located at the top front of the enclosure (under the upper lip of the enclosure cover). Do not close, seal, or obstruct these vent openings. They are designed to prevent hazardous gases from building up in the enclosure over time. See Diagram 1.
Vent
Vent
CL SUPPLY INPUT
ELECTRICAL
CL RETURN TO SUPPLY
CL DISPENSE
IN-CL-14
3/11/14 HW
Page 2 of 10
Diagram 1
Mounting Holes
START UP / PUMP CALIBRATION Mechanical Adjustment: Note: Your CL unit comes factory set at 50% flow.
By adjusting the angle of the high pressure pump head (pump head on right side of drive) using the adjustment knob, piston displacement can be increased and decreased, which in turn will vary flow rate. Diagram 6 shows the minimum (0%), maximum (100%), and factory set (50%) pump head positions.
Electronic Adjustment: The C100A Variable Speed
Controller varies pump speed and has both manual and electronic control modes.
For manual speed adjustment, set the C100A ON/OFF switch to the “ON” position and set the rotary dial to 6. Turn On and measure discharge flow. Adjust flow as necessary.
For speed control from an external 4-20mA source, set the ON/OFF switch to the “AUTO” position.
Diagram 6
FLUIDIC CONNECTIONS
1. Connect the supply tubing from the hypochlorite supply vessel to the 1/4” NPT female CL Supply Inlet fitting of the Chloritrol CL. Supply tubing
should be 1/4” to 3/8” ID semi-rigid translucent tubing, LDPE (low density polyethylene) or
equivalent. Refer to Fluidic Overview Diagram 5.
Important Note: Do not use any fittings having
Buna-N seal elements. Only Viton® should be used.
2. Connect the Return tubing from the 1/4” NPT female CL Return back to the supply vessel.
Return tubing should be 1/4” to 3/8” ID semi­rigid tubing, LDPE (low density polyethylene) or equivalent. Refer to Fluidic Overview Diagram 5.
3. Connect 1/4” OD tubing (semi-rigid suggested), from the CL Dispense (1/4” NPT
female) to the point of chlorination, typically
the groundwater well or water main.
Sodium Hypochlorite
Chlorine Analyzer
or other 4-20 mA source
IN-CL-14
3/11/14 HW
Diagram 5
Fluidic Overview
Page 3 of 10