Flytech POS 600, POS 605 Technical Manual

Page 1
POS600/605
with B55 M/B
Installation Guide
48200142
July 2003 (V2.0)
Point-of-Sale
Page 2
1. Accessory
External Floppy Cable
VFD Cable VGA Cable (optional for second display)
Drivers Bank Warranty Card
The following drivers in the folders of Driver Bank are necessary for driver installation:
Folder Driver Function
Acrobat Acrobat Reader Installation
BIOS Tool BIOS Update Tool
Common
B55
Test Utility
 When using B55 Mainboard, the Touch Screen was set on COM5. The Netmos driver
must be loaded to enable COM5 & COM6 before installing ELO touch driver to COM5.
CDROMDrv CDROM driver installation (for DOS)
Elo_Touch Touch screen driver Installation LAN_drive LAN driver installation
Netmos Enable COM5/COM6
Smart Card Smart Card driver installation
Audio Audio driver Installation
UDMA UDMA driver installation
VGA VGA driver installation Card Reader Card Reader Test Program Cash Drawer Cash Drawer Test Program
VFD Customer Display Test Program
Power Cable
2
Page 3
9
7
5 8
1
3 4
2
6
1
2. I/O Function
2.1 Front View
1
3
# Function # Function
1 Power Switch 5PCMCIA slot 2 CD-ROM Drive 6Smart Card slot 3 MIC/Line-In/Line-Out 7 Key Lock 4 USB 3 & 4
2.2 Rear View
# Function # Function 1 DC Output 24V/2.0A 8 COM4(optional 2nd VGA port) 2 PS/2 Mouse 9 Cash Drawer 1 3 PS/2 Keyboard 10 Cash Drawer 2 4 LPT 11 LAN 5 COM1 12 USB1&2 6 COM2 13 AC Inlet 7 COM3
4
2
5
6
11
12
10
7
13
Note: If you installed second display of COM4 , the Card Reader must be use keyboard type.
2.3 Side View
# Function 1 Compact Flash Slot
2 External FDD Connector
2
3
Page 4
3. Specification
Item Description Core Logic SiS 630ST Single Chip CPU Supports Intel® Socket 370 CPUs Celeron® /PIII ® FC-PGA /FC-PGA2
FSB 66/100/133Mhz Internal Cache Built-in CPU External Cache Built-in CPU System RAM 2 x 168-pin DIMM sockets, up to 1GB FSB 66/100/133MHz BIOS Award PnP BIOS Video Display Built-in Core Logic Video RAM SMA 2MB/4MB/8MB/16MB/32MB/64MB IDE controller UDMA33/66/100 One primary 40-pin 2.54 pitch & one 44-pin 2.0 pitch I/O Controller Built-in Core Logic SiS 630ST supports USB x 2
W83697HF x 1, supports PS2 Keyboard / PS2 Mouse x 1,
COM1&2/LPT x 1
W83697HF x 1, supports COM3&4, Netmos/PCI 9835 COM5&6 Audio Controller Built-in Core Logic supports AC97 2.1 w/CODEC LAN controller RTL8139C 10/100Mbps Fast Ethernet I/O Connector Port Audio(Line-in, Line-out, MIC), 24V2A DC output x1, RJ-45 LAN x1
USB x 4, Printer x1, COM x 4 ,pin1/pin9 w/5V/+12V selectable
Cash Drawer x2 12V/24V selectable Cash Drawer Port Two Ports, output address 200H/input address 201H Compact Flash Socket supported HDD drive One 3.5" HDD (optional) CD-ROM drive One slim CD-ROM/DVD/CD-RW (optional) FDD connector Ext. 40-pin connector with DC power PCMCIA/Smart Card Slot Internal Speaker Built-in two speakers x 1W LCD Panel
Card Reader Options keyboard and serial interface type (3-track) Customer Display Options Fix type customer display supports LED/VFD/LCD type
Second display Optional 8.4”/10.4”/12.1” TFT LCD display Power Supply FT-8150 internal ATX 150W (+12V/4A, -12V/0.3A, -5V/0.2A,
Operation Temp. 5° ~ 35°
System Dimension 332 (W) x 344 (D) x 204-302(H) mm (POS600)
Weight N.W. 7.5kgs/ G.W 9kgs (POS600)
Bundled at factory site (optional)
12.1“ TFT LCD Panel, resolution 800x600
resistive touch panel view angle 0°- 60°(POS600)
15“ TFT LCD Panel, resolution 1024x768
resistive touch panel view angle 0°- 60°(POS605)
Pole display supports LED/VFD/LCD type
5Vsb/1.5A, +5V/14A & 3.3V/10A max 100W)
CE Class-A EMI/EMS
FCC(This device complies with part 15 of the FCC rules. Operation is
subject to the following two condition: (1)This device may not cause
harmful interference and (2) This device must accept any interference
received, including interference that may cause undesired operation. )
379(W) x 346.5 –362.5 (D) x 212.6 – 323.5 (H ) mm (POS605)
N.W. 8.0kgs/ G.W 9.5kgs (POS605)
4
Page 5
3.1 System Memory Combination
POS600/605 RAM Size
Slot DIMM1 X 128 128 256 X 256 512 X 512 DIMM2 128 X 128 X 256 256 X 512 512
Please note that DIMM1 of POS600 does not support RAM over 29 mm in height.
128MB 256MB 512MB 1024MB
4. Install External Device
4.1 Install System FDD
a. Connect the FDD cable from 40 pin FDD
connector left side of LCD module..
c.Move the arrow key downward to the
"Onboard Super IO Device" item
b. Enter "Integrated Peripherals" of the
Main Menu of BIOS CMOS Setup Utility.
d. Move the arrow key downward to the
"FDC Controller" item. Use "Page Up" or "Page Down" key change to “Enable”
5
Page 6
e. Enter "Standard CMOS Features" of the
Main Menu of BIOS CMOS Setup Utility.
f. Move the arrow key downward to the
"Drive A" item.
g. Use "Page Up" or "Page Down" key for
FDD Installation. Make sure you save the changes by pressing F10 key or moving to "Save & Exit Setup."
6
Page 7
4.2 Install the Magnetic Card Reader Module (optional)
The MCR unit is tested and can be supplied at your request. This MCR is removed during
transportation and can be connected by the user. There are two types of MCR Module,
either by the COM type or keyboard type. If the product barcode is P0700300, then the
system you order is a COM type, and P0700400 stands for a keyboard type.
Card
Reader
a. Push into the MCR module at the right side of System LCD Module then lock it with two screws.
b. If you select K/B Wedge MCR, we provide a Terminator for you to insert into K/B PS2 for simulate PS2 K/B so you can
Ter mi na to r
use K/B Wedge MCR under NT/2K/XP OS.
4.3 Install the Card Reader with I-button
Push into the MCR module at the right side of System LCD Module then lock it with two screws.
7
Page 8
4.4 Install Cash Drawer
Please confirm the pin assignment before installing a cash drawer through the cash drawer port
4.4.1 Cash Drawer Pin Assignment
Pin Signal Pin Signal
1 GND 7 GND 2 DOUT bit0 8 DOUT bit2 3 DIN bit0 9 DIN bit1 4 12V/24V 10 12V/24V 5 DOUT bit1 11 DOUT bit3 6 GND 12 GND
Data out address(200h)
Data in address(201h)
4.5 Install Customer Display
a. Insert the RS232 cable into any of the Com ports.
b. Insert the other end of the RS232 cable into the RJ45 connector of the Customer Display module.
c. Fasten the two screws at the right and left of the Customer Display module.
4.6 Install 2nd VGA.
For 2nd VGA installation, please refer to our "Second Display Installation Guide."
8
Page 9
5.Driver Installation
The following procedures are for Windows 2000. Other platforms are similar.
5.1 Netmos
a. Click "COMMON" on the POS driver window.
b. Click “OK” on the Files Needed window. c. Indicate the location of the Netmos driver.
d. Choose “Nm2kMf” in the Locate File
window.
e. Click “OK” on the Files Needed window.
f. Now the Netmos driver is installed.
9
Page 10
5.2 Elo_Touch
a. Click "COMMON" on the POS driver window.
b. Click "Elo_Touch" on the COMMON
window.
c. Choose the OS to be installed with Elo
_Touch driver.
d. Click “Setup” on the EloWin2000
window.
e. Click “Next” on the Elo MonitorMouse for
Windows 2000 Setup window.
d. Choose “COM5” and click “Next” on the
Elo MonitorMouse for Windows 2000 Setup window.
e. Click “Finish” on the Elo MonitorMouse
for Windows 2000 Setup window.
10
Page 11
f. Click “Yes” on the System Settings
Change.
g. After the computer restarted, touch the
targets with your finger for alignment.
h. Click “Yes” on the Check Video
Alignment window.
i. Click “Finish” on the “Elo TouchSystem
Setup window.
j. If the cursor is not in sync with your finger
tip, click “Align…” to execute the alignment procedure again, or click “OK”
k. Now the Elo_Touch driver is installed.
11
Page 12
5.3 Smart Card
a. Click "COMMON" on the POS driver window.
b. Click “SmartCard” on the COMMON
c. Click “EZ100PR” on the Setup window.
window.
d. Click “EzprSetup”on the EZ100PR
window.
e. Click “Yes” on the EZ100 PR Setup
window.
f. Click "OK" on Notice window. g. Click "OK" on the EZ100PR PC/SC
Smart Card Reader window.
h. Now the Smart Card driver is installed.
12
Page 13
5.4 VGA
a. Click “B55” on the POS driver window. b. Click “VGA” on the B55 window.
c. Click “Win2000” on the VGA window. d. Click “SETUP” On the VGA2000 window.
e. Click “Next” on the Welcome window. f. Click "Next" on the Setup Type window.
13
Page 14
g. Click "Next" on the Select Program Folder window..
i. Click "Finish" on the Setup Complete
window.
h. Click "Next" on the Select Copying Files
window.
j. Now the VGA driver is installed.
14
Page 15
RICOH
CN1
CN2
JP9
6. Jumper Setting
6.1 Location of Main Board
JP3
CN4
CN12
PCI 1
U19ISL6524CB
JP8
U2
U25
Philips
P83C552
EBA/138
JP10
U33 NetMOS NM9835
CV
JP15
BZ
D31
D36
JP13
JP4
BAT1
D33
DIMM2
DIMM1
CN5
CN6
CN7
CN9
CN10
JAPAN
R5C475II
2AA8Q0
U23
WinBon
Bios
U30
6.1.1 Compact Flash IDE Selection *Factory Default Setting Function JP2
Master *ON
Slave OFF
6.1.2 CMOS Operation Mode
Function JP13 JP15
CMOS Normal *1-2 *1-2
CMOS Clear 2-3 2-3
JP2
JP1
CN3
W83
697
HF
CN8
U18
RTL8139C
U27
JP6
15
Page 16
6.1.3 Power Supply Type
Function JP6 Function JP6
ATX Power *2-3 AT Power 1-2
6.1.4 CPU Frequency Ratio SelectionJP1
Ratio 1-2 3-4 5-6 7-8 Na ON OFF ON ON
1.5 ON ON ON OFF 2 OFF OFF OFF OFF
2.5 OFF ON OFF OFF 3 OFF OFF OFF ON
3.5 OFF ON OFF ON 4 OFF OFF ON OFF
4.5 OFF ON ON OFF 5 OFF OFF ON ON
5.5 OFF ON ON ON 6 ON OFF OFF OFF
6.5 ON ON OFF OFF 7 ON OFF OFF ON
7.5 ON ON OFF ON 8 ON OFF ON OFF
6.1.5 CPU-FSB/RAM/PCI Frequency Selection (MHz): JP3
CPU-FS
B
66.6 66.6 33.3 OFF OFF OFF OFF
66.6 100 33.3 OFF OFF ON OFF
66.6 133 33.3 OFF OFF ON ON 100 66.6 33.3 ON OFF ON OFF 100 100 33.3 ON OFF OFF OFF 100 133 33.3 OFF ON ON OFF 100 150 30 ON OFF ON ON 112 112 33.6 OFF OFF OFF ON 124 124 31 ON OFF OFF ON 133 100 33.3 ON ON ON OFF 133 133 33.3 ON ON OFF OFF 138 138 34.5 OFF ON OFF ON 150 100 30 OFF ON ON ON 150 150 30 ON ON OFF ON 160 120 30 ON ON ON ON 166 166 33.3 OFF ON OFF OFF
SDRAM PCI 1-2 3-4 5-6 7-8
16
Page 17
6.2 I/O Connector Jumper Setting
The COM port and Cash Drawer jumpers are located on the bottom of the base unit. Remove the screw of jumper cover to access jumpers.
6.2.1 Location of I/O Connector Board
34
33
COM1
JP1 JP2
24
2
23
1
COM2
Cash Drawer
COM2
COM3 COM4
2
1
6.2.2 COM1/COM2 /Cash Drawer DC Power Jumper SettingJP1
COM1 COM2 Cash Drawer
33-34 31-32 29-30 27-28 25-26 23-24 21-22 19-20 17-18 15-16 13-14 11-12 9-10 7-8 5-6 3-4 1-2
DCD1 ● 5V +12V RI-1
●
5V +12V
DCD2
5V +12V RI-2
●
5V +12V +12V +12V +24V
●
●
+24V
●
PIN1 PIN9 PIN1 PIN9
● Factory Default Setting
6.2.3 COM3/COM4 DC Power Jumper SettingJP2
COM3 COM4
23-24 21-22 19-20 17-18 15-16 13-14 11-12 9-10 7-8 5-6 3-4 1-2
DCD3
●
● Factory Default Setting
5V +12V RI-3 ● 5V +12V DCD4● 5V +12V RI-4 ● 5V +12V
PIN1 PIN9 PIN1 PIN9
17
Page 18
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions carefully. Save these instructions for future reference.
2. Follow all warnings and instructions marked on the product.
3. Do not use this product near water.
4. Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious damage to the product.
5. Slots and openings in the cabinet and the back or bottom are provided for ventilation; to ensure reliable operation of the product and to protect it from overheating, these openings must not be blocked or covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or heat register, or in a built-in installation unless proper ventilation is provided.
6. This product should be operated from the type of power indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company.
7. Do not allow anything to rest on the power cord. Do not locate this product where persons will walk on the cord.
8. Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock. Never spill liquid of any kind on the product.
Caution on Lithium Batteries
Danger of explosion if battery is incorrectly replaced. Replace only with the same or
equivalent type recommended by the manufacturer. Discard used batteries according
to the manufacturer’s instructions.
CD-ROM Safety Warning
DANGER
INVISIBLE RADIATION WHEN OPEN.
AVOID EXPOSURE TO BEAM.
18
Loading...