2Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 5
Introduction and Safety
Introduction
Purpose of this manual
The purpose of this manual is to provide necessary information for:
• Installation
• Operation
• Maintenance
CAUTION:
Read this manual carefully before installing and using the product. Improper use of the
product can cause personal injury and damage to property, and may void the warranty.
NOTICE:
Save this manual for future reference, and keep it readily available at the location of the
unit.
Introduction and Safety
Safety
WARNING:
• The operator must be aware of safety precautions to prevent physical injury.
• Any pressure-containing device can explode, rupture, or discharge its contents if it is
over-pressurized. Take all necessary measures to avoid over-pressurization.
• Operating, installing, or maintaining the unit in any way that is not covered in this manual
could cause death, serious personal injury, or damage to the equipment. This includes
any modification to the equipment or use of parts not provided by Xylem. If there is a
question regarding the intended use of the equipment, please contact an Xylem
representative before proceeding.
• This manual clearly identifies accepted methods for disassembling units. These methods
must be adhered to. Trapped liquid can rapidly expand and result in a violent explosion
and injury. Never apply heat to impellers, propellers, or their retaining devices to aid in
their removal.
• Do not change the service application without the approval of an authorized Xylem
representative.
CAUTION:
You must observe the instructions contained in this manual. Failure to do so could result in
physical injury, damage, or delays.
Safety terminology and symbols
About safety messages
It is extremely important that you read, understand, and follow the safety messages and
regulations carefully before handling the product. They are published to help prevent
these hazards:
• Personal accidents and health problems
• Damage to the product
• Product malfunction
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual3
Page 6
Introduction and Safety
Hazard levels
Hazard levelIndication
Hazard categories
DANGER:
WARNING:
CAUTION:
NOTICE:
Hazard categories can either fall under hazard levels or let specific symbols replace the
ordinary hazard level symbols.
Electrical hazards are indicated by the following specific symbol:
A hazardous situation which, if not avoided, will result in
death or serious injury
A hazardous situation which, if not avoided, could result
in death or serious injury
A hazardous situation which, if not avoided, could result
in minor or moderate injury
• A potential situation which, if not avoided, could
result in undesirable conditions
• A practice not related to personal injury
Electrical Hazard:
These are examples of other categories that can occur. They fall under the ordinary hazard
levels and may use complementing symbols:
• Crush hazard
• Cutting hazard
• Arc flash hazard
Environmental safety
The work area
Always keep the station clean to avoid and/or discover emissions.
Waste and emissions regulations
Observe these safety regulations regarding waste and emissions:
• Appropriately dispose of all waste.
• Handle and dispose of the processed liquid in compliance with applicable
environmental regulations.
• Clean up all spills in accordance with safety and environmental procedures.
• Report all environmental emissions to the appropriate authorities.
4Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 7
Electrical installation
Recycling guidelines
User safety
General safety rules
Introduction and Safety
WARNING:
Do NOT send the product to the Xylem manufacturer if it has been contaminated by any
nuclear radiation. Inform Xylem so that accurate actions can take place.
For electrical installation recycling requirements, consult your local electric utility.
Always recycle according to these guidelines:
1. Follow local laws and regulations regarding recycling if the unit or parts are
accepted by an authorized recycling company.
2. If the first guideline is not applicable, then return the unit or parts to your Xylem
representative.
These safety rules apply:
• Always keep the work area clean.
• Pay attention to the risks presented by gas and vapors in the work area.
• Avoid all electrical dangers. Pay attention to the risks of electric shock or arc flash
hazards.
• Always bear in mind the risk of drowning, electrical accidents, and burn injuries.
Safety equipment
Use safety equipment according to the company regulations. Use this safety equipment
within the work area:
Electrical connections
Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local regulations. For more information about
requirements, see sections dealing specifically with electrical connections.
Hazardous liquids
The product is designed for use in liquids that can be hazardous to your health. Observe
these rules when you work with the product:
• Hard hat
• Safety goggles, preferably with side shields
• Protective shoes
• Protective gloves
• Gas mask
• Hearing protection
• First-aid kit
• Safety devices
NOTICE:
Never operate a unit unless safety devices are installed. Also see specific information
about safety devices in other chapters of this manual.
• Make sure that all personnel who work with biologically hazardous liquids are
vaccinated against diseases to which they may be exposed.
• Observe strict personal cleanliness.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual5
Page 8
Introduction and Safety
Wash the skin and eyes
Follow these procedures for chemicals or hazardous fluids that have come into contact
with your eyes or your skin:
ConditionAction
Product warranty
Coverage
Limitations
Chemicals or hazardous
fluids in eyes
Chemicals or hazardous
fluids on skin
Xylem undertakes to remedy defects in products from Xylem under these conditions:
• The faults are due to defects in design, materials, or workmanship.
• The faults are reported to an Xylem representative within the warranty period.
• The product is used only under the conditions described in this manual.
• The monitoring equipment incorporated in the product is correctly connected and in
use.
• All service and repair work is done by Xylem-authorized personnel.
• Genuine Xylem parts are used.
• Only Ex-approved spare parts and accessories authorized by Xylem are used in Exapproved products.
The warranty does not cover defects caused by these situations:
• Deficient maintenance
• Improper installation
• Modifications or changes to the product and installation made without consulting
Xylem
• Incorrectly executed repair work
• Normal wear and tear
Xylem assumes no liability for these situations:
• Bodily injuries
• Material damages
• Economic losses
1.Hold your eyelids apart forcibly with your fingers.
2.Rinse the eyes with eyewash or running water for at least 15 minutes.
3.Seek medical attention.
1.Remove contaminated clothing.
2.Wash the skin with soap and water for at least 1 minute.
3.Seek medical attention, if necessary.
Warranty claim
Xylem products are high-quality products with expected reliable operation and long life.
However, should the need arise for a warranty claim, then contact your Xylem
representative.
Spare parts
Xylem guarantees that spare parts will be available for 15 years after the manufacture of
this product has been discontinued.
6Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 9
Transportation and Storage
Inspect the delivery
Inspect the package
1. Inspect the package for damaged or missing items upon delivery.
2. Note any damaged or missing items on the receipt and freight bill.
3. File a claim with the shipping company if anything is out of order.
If the product has been picked up at a distributor, make a claim directly to the
distributor.
Inspect the unit
1. Remove packing materials from the product.
Dispose of all packing materials in accordance with local regulations.
2. Inspect the product to determine if any parts have been damaged or are missing.
3. If applicable, unfasten the product by removing any screws, bolts, or straps.
For your personal safety, be careful when you handle nails and straps.
4. Contact your sales representative if anything is out of order.
Transportation and Storage
Transportation guidelines
Precautions
WARNING:
• Stay clear of suspended loads.
• Observe accident prevention regulations in force.
Position and fastening
The unit can be transported either horizontally or vertically. Make sure that the unit is
securely fastened during transportation, and cannot roll or fall over.
Lifting
WARNING:
• Crush hazard. The unit and the components can be heavy. Use proper lifting methods
and wear steel-toed shoes at all times.
• Lift and handle the product carefully, using suitable lifting equipment.
• The product must be securely harnessed for lifting and handling. Use eyebolts or lifting
lugs if available.
• Always lift the unit by its lifting handle. Never lift the unit by the motor cable or by the
hose.
• Do not attach sling ropes to shaft ends.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual7
Page 10
Transportation and Storage
Lifting equipment
Lifting equipment is always required when handling the unit. It must fulfill the following
requirements:
• The minimum height (contact Xylem for information) between the lifting hook and the
• The lifting equipment must be able to hoist the unit straight up and down, preferably
• The lifting equipment must be securely anchored and in good condition.
• The lifting equipment must support weight of the entire assembly and must only be
• Two sets of lifting equipment must be used to lift the unit for repair work.
• The lifting equipment must be dimensioned to lift the unit with any remaining pumped
• The lifting equipment must not be oversized.
floor must be sufficient to lift the unit.
without the need for resetting the lifting hook.
used by authorized personnel.
media in it.
NOTICE:
Oversized lifting equipment could cause damage if the unit should stick when being
lifted.
Temperature ranges for transportation, handling and storage
Handling at freezing temperature
At temperatures below freezing, the product and all installation equipment, including the
lifting gear, must be handled with extreme care.
Make sure that the product is warmed up to a temperature above the freezing point before
starting up. Avoid rotating the impeller/propeller by hand at temperatures below the
freezing point. The recommended method to warm the unit up is to submerge it in the
liquid which will be pumped or mixed.
NOTICE:
Never use a naked flame to thaw the unit.
Unit in as-delivered condition
If the unit is still in the condition in which it left the factory - all packing materials are
undisturbed - then the acceptable temperature range during transportation, handling and
storage is: –50°C (–58ºF) to +60°C (+140ºF).
If the unit has been exposed to freezing temperatures, then allow it to reach the ambient
temperature of the sump before operating.
Lifting the unit out of liquid
The unit is normally protected from freezing while operating or immersed in liquid, but the
impeller/propeller and the shaft seal may freeze if the unit is lifted out of the liquid into a
surrounding temperature below freezing.
Units equipped with an internal cooling system are filled with a mixture of water and 30%
glycol. This mixture remains a flowing liquid at temperatures down to –13°C (9°F). Below –
13°C (9°F), the viscosity increases such that the glycol mixture will lose its flow properties.
However, the glycol-water mixture will not solidify completely and thus cannot harm the
product.
Follow these guidelines to avoid freezing damage:
8Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 11
1. Empty all pumped liquid, if applicable.
2. Check all liquids used for lubrication or cooling, both oil and water-glycol mixtures, for
the presence of water. Change if needed.
Storage guidelines
Storage location
The product must be stored in a covered and dry location free from heat, dirt, and
vibrations.
NOTICE:
• Protect the product against humidity, heat sources, and mechanical damage.
• Do not place heavy weights on the packed product.
Long-term storage
If the unit is stored more than 6 months, the following apply:
• Before operating the unit after storage, it must be inspected with special attention to
the seals and the cable entry.
• The impeller/propeller must be rotated every other month to prevent the seals from
sticking together.
Transportation and Storage
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual9
Page 12
Product Description
Product Description
Pump Design
Intended Use
The product is intended for moving wastewater, sludge, raw and clean water. Always
follow the limits that are given in Application limits (page 56). If there is a question
regarding the intended use of the equipment, please contact a Xylem representative
before proceeding.
WARNING:
In explosive or flammable environments, only use Ex- or MSHA-approved pumps.
NOTICE:
Do NOT use the pump in highly corrosive liquids.
10Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 13
Parts
1
2
3
8
7
6
5
4
12
11
10
9
13
WS003673A
15
7
9
14
14
13
Product Description
Figure 1: Section view, top view and exploded view of hydraulic parts.
PositionPartDescription
1Terminal board
2Support bearingTwo-row ball bearing
3ShaftStainless steel, with an integrated rotor
4Rotor
5Main bearingsTwo-row angular contact ball bearing in O-arrangement
6Seal housingContains inner and outer mechanical seals. Includes a coolant that lubricates
and cools the seals; the housing acts as a buffer between the pumped fluid
and the electric motor
7Propeller
8Seal ring
9Bell mouthWith integrated relief groove
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual11
Page 14
2
131214
22
21
20
171819161591011
8
7
6
5
4
3
1
23
24
Product Description
PositionPartDescription
10Pump housing
11StatorEquipped with temperature sensors in windings
12Electrical lead-through
unit
13Cable entry
14Lifting handle
15Guide vanes
Spare part requirements
The following applies when servicing or repairing the pump:
• Modifications to the unit or installation should only be carried out after consulting with
Xylem.
• Original spare parts and accessories authorized by Xylem are essential for compliance.
The use of other parts can invalidate any claims for warranty or compensation. For
more information contact your Xylem representative.
The monitoring equipment
MiniCAS II
The table below shows the parameters which can be tracked with the MiniCAS II
monitoring system.
ParameterSensorStandard or optional
Stator winding temperatureOne of the following choices:
Standard
• 3 thermal switches (standard), or
• 3 PTC-thermistors (optional)
Leakage in the inspection chamberFloat Switch Leakage Sensor (FLS)Standard
Leakage in the junction boxFloat Switch Leakage Sensor (FLS)Optional
The data plate
The data plate is a metal label located on the main body of the products. The data plate
lists key product specifications. Specially approved products also have an approval plate.
12Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
1.Curve code/Propeller code
2.Serial number, see Product denomination (page 14)
3.Product number
4.Country of origin
Page 15
5.Additional information
6.Phase; type of current; frequency
7.Rated voltage
8.Thermal protection
9.Thermal class
10. Rated shaft power
11. International standard
12. Degree of protection
13. Rated current
14. Rated speed
15. Maximum submergence
16. Direction of rotation: L=left, R=right
17. Duty class
18. Duty factor
19. Product weight
20. Locked rotor code letter
21. Power factor
22. Maximum ambient temperature
23. Read installation manual
24. Notified body. Only for EN-approved Ex-products
Figure 2: The data plate
Approvals
Product approvals for hazardous locations
PumpApproval
Product Description
EN approval plate
7030.090European Norm (EN)
• ATEX Directive
• EN 60079-0, EN 60079-1, EN 1127-1
•
II 2 G Ex d IIB T3
IEC
• IECEx scheme
• IEC 60079–0, IEC 60079–1
• Ex d IIB T3
EN approval for cable entry:
• Certificate number: INERIS 02ATEX9008 U
•
II 2 G Ex d IIC or I M2 Ex d I
Factory Mutural (FM)
• Class I. Div 1. Group C and D
• Dust ignition proof for use in Class II. Div 1. Group E, F and G
• Suitable for use in Class III. Div 1. Hazardous Locations
This illustration describes the EN approval plate and the information contained in its fields.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual13
Page 16
123
4
5
67
8
910
12
11
13
14
15
WS003972A
WS001279B
21
876
3
4
59
10
11
12
13
1
2
WS003973A
Product Description
IEC approval plate
1.Approval
2.Approval authority +
approval number
3.Approval for Class I
4.Approved drive unit
5.Stall time
6.Starting current/Rated
current
7.Duty class
8.Duty factor
9.Input power
10. Rated speed
11. Controller
12. Additional information
13. Maximum ambient
temperature
14. Serial number
15. ATEX marking
This illustration describes the IEC approval plate and the information contained in its fields.
International Norm; not for EU member countries.
1.Approval
2.Approval authority +
approval number
3.Approved for drive unit
4.Stall time
5.Starting current/Rated
current
6.Duty class
7.Duty factor
8.Input power
9.Rated speed
10. Controller
11. Additional information
12. Max. ambient temperature
13. Serial number
FM approval plate
This illustration describes the FM approval plate and the information contained in its fields.
1.Temperature class
2.Maximum ambient
temperature
Product denomination
14Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 17
Sales denomination
1
NP 3085
23
3085.183
12
NP
1
NP 3085.183 - 951 0163
23 4
Product code
Serial number
Product Description
The sales denomination consists of the four-digit sales code and two letters that indicate
the hydraulic end and type of installation.
This is an example of a sales denomination, and an explanation of its parts.
1.Hydraulic part
2.Installation type
3.Sales code
The product code consists of nine characters divided into two parts.
This is an example of a product code, and an explanation of its parts.
1.Sales denomination
2.Version
The serial number is used for identification of an individual product, and is divided into
four parts.
This is an example of a serial number, and an explanation of its parts.
1.Product code
2.Production year
3.Production cycle
4.Running number
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual15
Page 18
Installation
Installation
Fasteners
WARNING:
• Only use fasteners of the proper size and material.
• Replace all corroded fasteners.
• Make sure that all fasteners are properly tightened and that there are no missing
fasteners.
Requirements for the cable handling system
When the pump is installed in a discharge tube, it is critically important that a proper cable
support and protection system is used, especially with long power cables and closed
discharge tubes.
Checklist
This table shows the requirements to be fulfilled by the cable handling system.
RequirementCheck
Cables must be supported in such a way, so that they do not come in contact with any hard
surface which could abrade the cable sheathing. Examples of surfaces include pump and tube
components, lifting cables or wires and any other hardware.
Cables should be bundled together, using components that will not cut or abrade the cables.
Proper strain relief and support at prescribed intervals should be provided.
Spring-controlled tensioning and an integrated guide wire system is recommended for long
cables, to protect the cable from movement which can cause damage.
Install the pump
Consult the nearest Xylem representative regarding the following topics:
• Sizing of the pump, piping station, and access frame
• Choice of auxiliary equipment
• Other aspects of installation
WARNING:
• Note that special rules apply to installation in explosive atmospheres.
• Do not install the starter equipment in an explosive zone unless it is explosion-proof
rated.
• Check the explosion risk before welding or using electric hand tools.
• Provide a suitable barrier around the work area, e.g. a guard rail.
• Before installing the pump, check that the cable and cable entry have not been
damaged during transportation.
• A certified electrician must supervise all electrical work. Comply with all local codes and
regulations.
• Make sure that the unit cannot roll or fall over and injure people or damage property.
NOTICE:
• Do not run the pump dry.
• Never force piping to make a connection with a pump.
16Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 19
WS001675A
Installation
The pump is usually installed in a vertical discharge tube on a pump seat, which is
incorporated in the lower end of the tube. No anchoring is required because the weight of
the pump is sufficient to keep it in place. The pumps are equipped with anti-rotation
devices.
Figure 3: Pump in discharge tube (generic propeller pump shown)
When the pump is installed in a discharge tube, the following must be considered:
• A suitable cable support and protection system must be used.
Before installation, check the following:
• The propeller must rotate in the correct direction.
If the rotation is not in the correct direction, then the pump may lift and start rotating
inside the tube. This can seriously damage the equipment.
• The rubber seal ring underneath the pump is in place.
• There is no damage to, or debris on, the pump seat.
• There is no large construction debris under the pump tube (at the pump intake). If
debris is present then there is a risk that it can get sucked into the pump and cause
propeller damage.
• The pump control is set to turn the pump off at or above the minimum operating water
level for this pump installation.
1. After cable preparation, lower the pump into the pump column.
Make sure that the pump does not tilt on the stop vanes, which are at the bottom of the
column.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual17
Page 20
1
2
3
WS001677A
WS001678A
WS003676A
Installation
CorrectIncorrect
1Discharge column
2Antirotation gusset (stop vanes)
3Pump seat
2. Lower the pump to its bottom position, at the same time carefully moving it back and
forth between the nearest anti-rotation gusset.
Figure 4: Lowering pump while moving between anti-rotation gussets (generic propeller pump
shown)
3. Lift the pump slightly again, approximately 2-3 cm (1 in.), and turn it counterclockwise
until the anti-rotation device on the hydraulic end lands against the nearest adjacent
vanes.
18Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 21
2–3 cm (0.8–1.2 in.)
WS003677A
Figure 5: Turning pump until anti-rotation device is in place (generic propeller pump shown)
WS001680A
4. Lower the pump to its final bottom position.
No additional anchoring of the pump is required. Maximum permissible submersion
depth is 20 m (65 ft).
Installation
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual19
Figure 6: Lowering pump to final bottom position (generic propeller pump shown)
5. If the recommended cable handling system is used, then follow the instructions for
finishing the cable connection. See the document "Mounting Instructions, Flygt Cable
Handling System."
6. If the recommended cable handling system is not used, then fasten the power cables
on the cable holder, and run them to the electric junction box.
Make sure that the cables have no sharp bends, are not pinched, and do not disturb
the water flow.
Page 22
Installation
Make the electrical connections
General precautions
Electrical Hazard:
• A certified electrician must supervise all electrical work. Comply with all local codes and
regulations.
• Before starting work on the unit, make sure that the unit and the control panel are
isolated from the power supply and cannot be energized. This applies to the control
circuit as well.
• Leakage into the electrical parts can cause damaged equipment or a blown fuse. Keep
the end of the motor cable above the liquid level.
• Make sure that all unused conductors are insulated.
• There is a risk of electrical shock or explosion if the electrical connections are not
correctly carried out or if there is fault or damage on the product.
WARNING:
Do not install the starter equipment in an explosive zone unless it is explosion-proof rated.
Requirements
Cables
CAUTION:
If the pump is equipped with automatic level control and/or internal contactor, there is a
risk of sudden restart.
These general requirements apply for electrical installation:
• The supply authority must be notified before installing the pump if it will be connected
to the public mains. When the pump is connected to the public power supply, it may
cause flickering of incandescent lamps when started.
• The mains voltage and frequency must agree with the specifications on the data plate.
If the pump can be connected to different voltages, then the connected voltage is
specified by a yellow sticker close to the cable entry.
• The fuses and circuit breakers must have the proper rating, and the pump overload
protection (motor protection breaker) must be connected and set to the rated current
according to the data plate and if applicable the cable chart. The starting current in
direct-on-line start can be up to six times higher than the rated current.
• The fuse rating and the cables must be in accordance with the local rules and
regulations.
• If intermittent operation is prescribed, then the pump must be provided with
monitoring equipment supporting such operation.
These are the requirements to follow when you install cables:
• The cables must be in good condition, not have any sharp bends, and not be pinched.
• The sheathing must not be damaged and must not have indentations or be embossed
(with markings, etc.) at the cable entry.
• The minimum bending radius must not be below the accepted value.
• The voltage drop in long cables must be taken into account. The drive unit’s rated
voltage is the voltage measured at the cable connection point in the pump.
20Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 23
Earthing (Grounding)
1
2
WS003675A
3
4
5
5
4
4
4
6
7
8
Cable entry parts
Installation
Electrical Hazard:
• You must earth (ground) all electrical equipment. This applies to the pump equipment,
the driver, and any monitoring equipment. Test the earth (ground) lead to verify that it is
connected correctly.
• If the motor cable is jerked loose by mistake, the earth (ground) conductor should be the
last conductor to come loose from its terminal. Make sure that the earth (ground)
conductor is longer than the phase conductors. This applies to both ends of the motor
cable.
• Risk of electrical shock or burn. You must connect an additional earth- (ground-) fault
protection device to the earthed (grounded) connectors if persons are likely to come
into physical contact with the pump or pumped liquids.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual21
Page 24
Installation
CAUTION:
Leakage into the electrical parts can cause damaged equipment or a blown fuse. Keep the
end of the motor cable above the liquid level.
For more information about the cable entry, see the Parts list.
1. Remove the entrance cover and the O-ring from the stator housing.
This provides access to the terminal board.
2. Check the data plate to see which connections are required for the power supply.
3. Arrange the connections on the terminal board in accordance with the required power
supply.
Links (jumper strips) are not used with the Y/D start.
4. Connect the mains leads (L1, L2, L3, and earth (ground)) according to the applicable
cable chart.
The earth (ground) lead must be 120 mm (4.8 in.) longer than the phase leads in the
junction box of the unit.
5. Make sure that the pump is correctly connected to earth (ground).
6. Connect the control leads to the applicable terminal board, and twist the leads
together.
7. Make sure that any thermal contacts incorporated in the pump are properly connected
to the terminal board.
8. Install the entrance cover and the O-ring on the stator housing.
9. Fasten the screws on the entrance flange so that the cable insertion assembly bottoms
out.
Connect the motor cable to the starter and monitoring equipment
WARNING:
Do not install the starter equipment in an explosive zone unless it is explosion-proof rated.
1. If thermal contacts are included in the pump installation, connect the T1 and T2 control
conductors to the MiniCAS II monitoring equipment. Twist the monitoring wires
together.
2. If thermistors are included in the pump installation, and screened or auxiliary cable is
used, then connect T1(1) and T2(2) to thermistor relay, and T3(3) and T4 (4) to
MiniCAS II.
3. Connect the mains leads (L1, L2, L3, and earth [ground]) to the starter equipment.
For information about the phase sequence and the color codes of the leads, see Cable
charts (page 23).
4. Check the functionality of the monitoring equipment:
a) Check that the signals and the tripping function work properly.
b) Check that the relays, lamps, fuses, and connections are intact.
Replace any defective equipment.
22Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 25
Power cable phase sequence
L2
L1L2L3
L3L1
WS000578B
1
2
3
4
8
T2T1
7
6
5
In the following figure, the triangle marked “L1,” “L2” and “L3” shows the phase sequence.
Figure 7: Correct phase sequence
ItemDescriptionColor of cable lead
1L1 cable leadBrownBrown
2L2 cable leadBlackBlack
3L3 cable leadGreyGrey
4Earth PE or Ground cable leadGreen/YellowScreen from leads
5Functional groundIn cables with both power cores
6T1 cable lead (control
7T2 cable lead (control
8Power cable to pump
element)
element)
and control element.
In cables with both power cores
and control element.
In cables with both power cores
and control element.
Installation
SUBCABSUBCAB
(screened)
—
Cable charts
Connection locations
The figures in this section illustrate how to interpret the connection strip symbols.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual23
Page 26
L1 L2 L3
T3 T4T1 T2
1
2
3
4
U1
V1
W1
U2
W2
V2
U1
V1
W1
W2
U2
V2
U1
V1
W1
GC
W2
U2
V2
L1
L2
L3
*YE
GN/YE
WH
L1
U1
U2
W2
V2
W1
V1
L3
L2
WS004133B
L1 L2 L3
T3 T4T1 T2
43
21
5
10
8
CLS
6
FLS
7
FLS 10
11
9
WS004134A
Installation
1.Stator leads
2.Terminal board
3.Motor cable leads
4.Stator (internal connection illustrated)
1.Starter equipment and mains leads (L1, L2, L3)
2.Earth (ground)
3.Functional ground
4.Control leads (T1, T2, T3, T4)
5.Thermal contact
6.FLS
7.FLS 10
8.CLS
9.Thermistor
10. Level sensor
11. Capacitor
24Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 27
Colors and markings of leads
WS003909A
Terminal clamps 6 stator leads
Motor Connection
Colors and marking of the main leads
773 29 00/1
COLOR STANDARD
STATOR LEADS
BN = Brown
U1,U5 = RD
BK = Black
U2 = GN
WH = White
V1,V5 = BN
OG = Orange
V2 = BU
GN = Green
W1,W5 = YE
GN/YE = Green-Yellow
W2 = BK
RD = Red
T1,T2 = WH or YE
GY = Grey
BU = Blue
YE = Yellow
*SUBCAB AWG
* * Ground conductor is stranded around core
GC=Ground check
U1
W2
V1
U2
W1
V2
Mains
SUBCAB 7GX
SUBCAB 4GX
3
Screenflex 7GX
Screenflex 4GX
SUBCAB AWG
SUBCAB
Screened
L1
BK 1
BN
RD
BN
L2
BK 2
BK
BK
BK
L3
BK 3
GY
WH
GY
L1
BK 4
-
-
-
L2
BK 5
-
-
-
L3
BK 6
-
-
-
GN/YE
GN/YE
GN/YE
**Screen/PE
from cores
Screen (WH)
Screen (WH)
-
Screen (WH)
GC
-
-
YE
-
Motor Connection
773 29 00/1
COLOR STANDARD
STATOR LEADS
BN = Brown
U1,U5 = RD
BK = Black
U2 = GN
WH = White
V1,V5 = BN
OG = Orange
V2 = BU
GN = Green
W1,W5 = YE
GN/YE = Green-Yellow
W2 = BK
RD = Red
T1,T2 = WH or YE
GY = Grey
BU = Blue
YE = Yellow
*SUBCAB AWG
* * Ground conductor is stranded around core
GC=Ground check
If the propeller rotates in the wrong direction, then the pump lifts up and rotates, which
can damage the cables.
1. Start the motor.
2. Stop the motor after a few seconds.
3. Check the propeller rotation.
The correct direction of propeller rotation is clockwise when you look at the pump
from above.
radius in mm
Weight in kg/mOuter diameter,
minimum-maximum in
mm
Direction of propeller rotation. Generic pump shown.
Figure 21: Top view (A) and side view (B)
4. If the impeller/propeller rotates in the wrong direction, check that the phase leads are
correctly connected. See Power cable phase sequence (page 23).
After re-connecting phase leads, do this procedure again.
32Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 35
Operation
Precautions
WARNING:
• Never operate the pump without safety devices installed.
• Never operate the pump with the discharge valve closed.
• Make sure you have a clear path of retreat.
• Never work alone.
CAUTION:
If the pump is equipped with automatic level control and/or internal contactor, there is a
risk of sudden restart.
Distance to wet areas
Electrical Hazard:
Risk of electrical shock. Make sure no one gets closer than 20 m (65 ft.) to the unit when
being in contact with the pumped or mixed liquid.
Operation
Noise level
NOTICE:
The noise level of the product is lower than 70 dB. However, the noise level of 70 dB may
be exceeded in some installations and at certain operating points on the performance
curve. Make sure that you understand the noise level requirements in the environment
where the pump is installed. Failure to do so may result in hearing loss or violation of local
laws.
Start the pump
WARNING:
• If you need to work on the pump, make sure that it is isolated from the power supply and
cannot be energized.
• Make sure that the unit cannot roll or fall over and injure people or damage property.
• In some installations, the pump and the surrounding liquid may be hot. Bear in mind the
risk of burn injuries.
• Make sure nobody is close to the unit when it is started. The unit will jerk in the opposite
direction of the impeller rotation.
NOTICE:
Make sure that the rotation of the impeller is correct. For more information, see Check the
impeller rotation.
1. Remove the fuses or open the circuit breaker, and check that the impeller can be
rotated freely.
2. Conduct insulation test phase to ground. To pass, the value must exceed 5 megohms.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual33
Page 36
Operation
3. Check that the monitoring equipment works.
4. Start the pump.
34Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 37
Maintenance
Precautions
WARNING:
• Always follow safety guidelines when working on the product. See Introduction and
Safety (page 3).
• Disconnect and lock out electrical power before installing or servicing the pump.
• Make sure that the unit cannot roll or fall over and injure people or damage property.
• Rinse the unit thoroughly with clean water before working on the unit.
• Rinse the components in water after dismantling.
Make sure that you follow these requirements:
• Check the explosion risk before you weld or use electrical hand tools.
• Allow all system and pump components to cool before you handle them.
• Make sure that the product and its components have been thoroughly cleaned.
• Do not open any vent or drain valves or remove any plugs while the system is
pressurized. Make sure that the pump is isolated from the system and that pressure is
relieved before you disassemble the pump, remove plugs, or disconnect piping.
Maintenance
Torque values
All screws and nuts must be lubricated to achieve correct tightening torque. Screws that
are screwed into stainless steel must have the threads coated with suitable lubricants to
prevent seizing.
If there is a question regarding the tightening torques, please contact a sales
representative.
Screws and nuts
Table 5: Stainless steel, A2 and A4, torque Nm (ft-lbs)
For hexagon socket head screws with countersunk head, maximum torque for all property
classes must be 80% of the values for property class 8.8 above.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual35
Page 38
1
2
3
WS003631A
4
1
2
WS003633A
Maintenance
Changing the coolant
This figure shows where the plugs for change of coolant are placed on the unit.
1.Coolant plug
2.Inspection plug
3.Coolant plug
4.Outer screw
Figure 22: With a cooling jacket
Empty the coolant
WARNING:
The seal housing may be pressurized. Hold a rag over the inspection/ filling plugs to
prevent splatter.
1. Remove the outer screw and the inner screw of both coolant plugs, and the inspection
plug, on the hydraulic part.
1.Outer screw
2.Inner screw
36Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 39
WS003632A
WS003632A
Maintenance
2. Thread the hose of the hand-pump through the inner and outer holes into the seal
chamber.
3. Pump out any coolant from the seal chamber.
4. Remove the inspection plug.
5. Pump out any leakage from the inspection chamber.
6. Reassemble the inspection plug with a new O-ring. Remount the plug and tighten.
Tightening torque: 44 Nm (33 ft-lbs)
7. Remount the outer screw for the inspection plug.
Tightening torque: 76 Nm (57 ft-lbs)
Fill with coolant
Use a coolant that is a mixture of 70% water and 30% monopropylene glycol. The coolant
should prevent corrosion and be nonpoisonous (generally recognized as safe by the FDA
as food additives under part 184 and 182).
NOTICE:
Clean water with an anti-corrosive is an acceptable coolant when there is no risk of
freezing.
1. Thread the hose of the hand-pump through both of the holes into the seal chamber.
2. Pump coolant into the seal chamber until it overflows through the opposite hole.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual37
Page 40
WS003634A
WS003635A
Maintenance
Quantity: approximately 2 L (2.2 qt.).
3. Replace the O-rings with new ones.
4. Remount the oil plugs and tighten.
Tightening torque: 44 Nm (33 ft-lbs)
5. Remount the outer screws for the coolant plug.
Tightening torque: 76 Nm (57 ft-lbs)
Preparing for work on the hydraulic end
Some maintenance work on the hydraulic end of the pump, such as changing the impeller
or replacing zinc anodes, requires that the pump be turned upside-down. This section
provides instructions for removing the connection house and attaching an assembly and
dismantling stand in its place.
Remove the entrance cover
1. Remove the entrance cover screws.
2. Disconnect the motor cable leads.
3. Lift off the entrance cover.
38Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 41
WS003636A
Attach the assembly and dismantling stand
WS003637A
WS003666A
Two lifting devices are required for this task.
1. Bolt the assembly/dismantling stand (605 70 00) in position. Secure it using the screws
for the entrance cover.
Maintenance
2. Attach lifting straps as shown in the following figure, and lift the pump.
3. Place the drive unit upside down on the stand.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual39
Page 42
WS003638A
2
3
1
5
4
6
WS003614A
Maintenance
Replacing the propeller
Required tools:
• Stand 605 70 00
• 14 mm hexagon bit adapter with an extension bar
• Trim tool (17 mm hexagon bit adapter with an extension bar)
• Rod (wood or plastic) for locking the impeller in place.
WARNING:
A worn impeller and/or pump housing can have very sharp edges. Wear protective gloves.
During this procedure the pump is upside down. The stand 605 70 00 is used to support
the pump in the upside down position. For instructions for attaching the stand, see
Preparing for work on the hydraulic end (page 38).
The propeller parts are shown in the following figure.
1.Propeller screw
2.Washer
3.Propeller
4.Adjustment screw
40Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 43
5.Conical sleeve
2
1
3
WS000587A
6.Conical shaft end
Measure the clearance
Depending on the type of media that is being pumped the pump will more or less be
exposed to wear, mainly in the gap between the propeller blades and the pump housing.
The clearance between the propeller blades and the pump housing will increase. The
effect of this is that the capacity as well as the efficiency will drop. It should be noted that
these effects are not linearly proportional to the size of the clearance, but progressive.
Operating the pump when the blade–housing clearance has reached or exceeded the
clearance threshold will result in a loss of capacity (flow) and pump efficiency.
It is therefore recommended that the blade–housing clearance be checked at routine
inspections and worn parts be replaced as necessary. If the measured blade–housing
clearance exceeds the critical limit, then we recommend that the efficiency drop be
evaluated and replacement of worn parts be considered.
1. Measure the clearance between the propeller blades and the pump housing in a few
places to get an average value.
The blade–housing clearance can vary slightly as the propeller might not be perfectly
centered due to manufacturing tolerances.
Maintenance
1.Propeller
2.Pump housing
3.Critical clearance
Figure 23: Critical clearance
PumpClearance threshold for efficiency drop, mm (in)
70301.3 (0.051)
70351.2 (0.047)
70401.6 (0.063)
If the measured clearance is less than the threshold value given in the table above,
then the rest of the steps in this section can be omitted. If the measured clearance is
greater than the threshold value in the table above, then proceed as follows:
2. Measure the wear in the pump housing with a thickness gauge by placing the edge of
a ruler across the surface of the housing.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual41
Page 44
1
2
WS000589A
WS003620A
Maintenance
1.Ruler
2.Wear
3. Replace parts according to the table.
PumpWear measured, mm (in)Action
70300.3 (0.012)Replace the propeller
70350.3 (0.012)Replace the propeller
70400.4 (0.016)Replace the propeller
Remove the propeller
CAUTION:
Wear heavy work gloves when you handle impellers. The sharp edges can cause physical
injury.
1. Lock the propeller in place by inserting a rod or piece of wood through the pump
housing outlet.
1.0 (0.039)Replace the bell mouth
0.9 (0.035)Replace the bell mouth
1.2 (0.047)Replace the bell mouth
2. Loosen the propeller:
a) Remove the propeller screw and washer.
42Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 45
WS003615A
WS003619A
WS003617A
Maintenance
b) Turn the adjustment screw counterclockwise until the propeller breaks free from the
shaft.
Use the trim tool.
3. Remove the propeller and the propeller sleeve.
Install the propeller
1. Mount the propeller:
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual43
Page 46
WS003613A
WS003612A
WS003621A
1.5 mm
Maintenance
a) Make sure that the end of the shaft is free from burrs.
Polish off any flaws with a fine emery cloth.
b) Grease the shaft end.
NOTICE:
Surplus grease can cause the impeller to become loose. Remove surplus grease
from conical and/or cylindrical surfaces of shafts and/or sleeves.
c) Grease the conical sleeve and the threads of the adjustment screw.
d) Turn the adjustment screw 3/4 of a turn, so that it juts out from the sleeve 1.5 mm.
Use the trim tool.
e) Fit the sleeve onto the shaft.
f) Carefully fit the propeller to the shaft.
44Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 47
Make sure that the sleeve and propeller are pushed on straight onto the shaft. If not
WS003618A
WS003616A
they might get stuck part way on.
2. Fit the propeller screw and washer.
Maintenance
3. Tighten the propeller screw.
4. Tighten the propeller screw a further 1/8 turn (45°).
5. Check that the propeller can rotate freely.
Replace the bell mouth
1. Remove the 3 hexagonal screws securing the bell mouth.
If there are zinc anodes, then 6 hexagonal screws must be removed.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual45
Page 48
1
2
3
WS003763A
WS003667A
Maintenance
1.Hexagonal screws
2.Bell mouth
3.Pump housing
2. Lift off the bell mouth.
3. Put the new bell mouth in place.
4. If zinc anodes are used, then remount them.
5. Fasten the screws.
Replace the zinc anodes
1. Loosen the hexagonal screws securing the zinc anodes at the inlet.
2. Replace the zinc anodes and fasten the screws.
3. Loosen the hexagonal screws securing the anodes at the outlet.
46Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 49
WS003668A
4. Replace the zinc anodes and fasten the screws.
Service the pump
Maintenance
Type of servicePurposeInspection interval
Initial inspectionTo make a check up of the pump
condition by an authorized Xylem
service representative and, based
on the result and findings from
these measures, to determine the
intervals for periodical inspection
and major overhaul for the specific
installation.
and machine breakdown. Measures
to secure performance and pump
efficiency are defined and decided
for each individual application. It
can include such things as impeller
trimming, wear part control and
replacement, control of zinc-anodes
and control of the stator.
Major overhaulTo secure a long operating lifetime
for the product. It includes
replacement of key components
and the measures taken during an
inspection.
NOTICE:
Shorter intervals may be required when the operating conditions are extreme, for example
with very abrasive or corrosive applications or when the liquid temperatures exceed 40°C
(104°F).
Within the first year of operation.
Up to 12,000 hours or 3 years,
whichever comes first.
Applies to normal applications and
operating conditions at media
(liquid) temperatures <40°C.
Up to 24,000 hours or 6 years,
whichever comes first.
Applies to normal applications and
operating conditions at media
(liquid) temperatures <40°C.
Inspection
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual47
Page 50
Maintenance
Service itemAction
Cable
1.If the outer jacket is damaged, replace the cable.
2.Check that the cables do not have any sharp bends and are not
pinched.
Connection to powerCheck that the connections are properly tightened.
Electrical cabinetsCheck that they are clean and dry.
Propeller
1.Check the propeller clearance.
2.Replace the propeller, if necessary.
Inspection chamber
1.Drain all liquid, if any.
2.Check the resistance of the leakage sensor.
Normal value approx. 1200 ohms, alarm approx. 430 ohms.
InsulationUse a megger maximum 1000 V.
1.Check that the resistance between the earth (ground) and
phase lead is more than 5 megohms.
2.Conduct a phase-to-phase resistance check.
Junction box
1.General:
Check that it is clean and dry.
If it is wet:
a.Check the cable entry.
b.Replace the O-rings. (New O-rings should be fitted to all
O-ring seal joints opened during inspection.)
2.Terminal board: Check that the connections are properly
tightened.
Level regulatorsCheck the condition and functionality.
Lifting deviceCheck that local safety regulations are followed.
O-rings
1.Replace the coolant plug O-rings.
2.Replace the O-rings at the entrance or junction cover.
3.Grease the new O-rings.
Overload protection and other
Check the correct settings.
protections
Personnel safety devicesCheck the guard rails, covers, and other protections.
Rotation directionCheck the propeller rotation.
Seal housing
1.Fill with new coolant, if necessary.
2.Check that the freezing point is lower than -13°C (9°F).
Terminal boardCheck that the connections are properly tightened.
ThermistorCheck the resistance is between 20–250 ohms and the measured
voltage is maximum 2 V DC.
Voltage and amperageCheck the running values.
48Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 51
Major overhaul
For a major overhaul, take this action in addition to the tasks listed under Inspection.
Service itemAction
Support and main bearingReplace the bearings with new bearings.
Mechanical sealReplace with new seal unit.
Service in case of alarm
Alarm sourceAction
Maintenance
FLS10
The thermistor/thermal contactCheck the start and stop levels.
The overload protectionCheck that the propeller can rotate freely.
1.Drain the fluid in the inspection chamber. Fill with new coolant
if necessary.
2.Check the freezing point (lower than -13°C or 9°F).
Check the inspection chamber again after one week of operation. If
leakage has occurred:
1.Drain the fluid.
2.Change the mechanical seal unit.
3.Replace with new coolant.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual49
Page 52
Troubleshooting
Troubleshooting
Introduction
Follow these guidelines when troubleshooting the pump:
• Disconnect and lock out the power supply except when conducting checks that
require voltage.
• Make sure that no one is near the pump when the power supply is reconnected.
• When troubleshooting electrical equipment, use the following:
• Universal instrument multimeter
• Test lamp (continuity tester)
• Wiring diagram
The pump does not start
WARNING:
Always disconnect and lock out power before servicing to prevent unexpected startup.
Failure to do so could result in death or serious injury.
NOTICE:
Do NOT override the motor protection repeatedly if it has tripped. Doing so may result in
equipment damage.
CauseRemedy
An alarm signal has been triggered
on the control panel.
The pump does not start
automatically, but can be started
manually.
The installation is not receiving
voltage.
Check that:
• The impeller rotates freely.
• The sensor indicators do not indicate an alarm.
• The overload protection is not tripped.
If the problem still persists:
Contact the local Xylem service shop.
Check that:
• The start level regulator is functioning. Clean or replace if necessary.
• All connections are intact.
• The relay and contactor coils are intact.
• The control switch (Man/Auto) makes contact in both positions.
Check the control circuit and functions.
Check that:
• The main power switch is on.
• There is control voltage to the start equipment.
• The fuses are intact.
• There is voltage in all phases of the supply line.
• All fuses have power and that they are securely fastened to the fuse
holders.
• The overload protection is not tripped.
• The motor cable is not damaged.
The impeller is stuck.Clean:
50Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 53
CauseRemedy
• The impeller
• The sump in order to prevent the impeller from clogging again.
If the problem persists, refer to the Flygt Service Guide on the web or contact the local
Xylem service shop. Always state the serial number of your pump when you contact Xylem,
see Product Description (page 10).
The pump does not stop when a level sensor is used
WARNING:
Always disconnect and lock out power before servicing to prevent unexpected startup.
Failure to do so could result in death or serious injury.
CauseRemedy
Troubleshooting
The pump is unable to empty the
sump to the stop level.
There is a malfunction in the levelsensing equipment.
The stop level is set too low.Raise the stop level.
If the problem persists, refer to the Flygt Service Guide on the web or contact the local
Xylem service shop. Always state the serial number of your pump when you contact Xylem,
see Product Description (page 10).
Check that:
• There are no leaks from the piping and/or discharge connection.
• The impeller is not clogged.
• The non-return valve(s) are functioning properly.
• The pump has adequate capacity. For information:
Contact the local Xylem service shop.
• Clean the level regulators.
• Check the functioning of the level regulators.
• Check the contactor and the control circuit.
• Replace all defective items.
The pump starts-stops-starts in rapid sequence
CauseRemedy
The pump starts due to back-flow
which fills the sump to the start
level again.
Check that:
• The distance between the start and stop levels is sufficient.
• The non-return valve(s) work(s) properly.
• The length of the discharge pipe between the pump and the first non-
return valve is sufficiently short.
The self-holding function of the
contactor malfunctions.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual51
Check:
• The contactor connections.
• The voltage in the control circuit in relation to the rated voltages on the
coil.
• The functioning of the stop-level regulator.
• Whether the voltage drop in the line at the starting surge causes the
contactor's self-holding malfunction.
Page 54
Troubleshooting
If the problem persists, refer to the Flygt Service Guide on the web or contact the local
Xylem service shop. Always state the serial number of your pump when you contact Xylem,
see Product Description (page 10).
The pump runs but the motor protection trips
WARNING:
Always disconnect and lock out power before servicing to prevent unexpected startup.
Failure to do so could result in death or serious injury.
NOTICE:
Do NOT override the motor protection repeatedly if it has tripped. Doing so may result in
equipment damage.
CauseRemedy
The motor protection is set too low.Set the motor protection according to the data plate and if applicable the
cable chart.
The impeller is difficult to rotate by
hand.
The drive unit is not receiving full
voltage on all three phases.
The phase currents vary, or they are
too high.
The insulation between the phases
and ground in the stator is
defective.
The density of the pumped fluid is
too high.
There is a malfunction in the
overload protection.
If the problem persists, refer to the Flygt Service Guide on the web or contact the local
Xylem service shop. Always state the serial number of your pump when you contact Xylem,
see Product Description (page 10).
• Clean the impeller.
• Clean out the sump.
• Check the clearance between the propeller and the pump housing.
• Check the fuses. Replace fuses that have tripped.
• If the fuses are intact, notify a certified electrician.
Contact the local Xylem service shop.
1.Use an insulation tester. With a 1000 V DC megger, check that the
insulation between the phases and between any phase and ground is
> 5 megohms.
2.If the insulation is less:
Contact the local Xylem service shop.
Make sure that the maximum density is 1100 kg/m3 (9.2 lb/US gal)
• Change the impeller, or
• Change to a more suitable pump.
• Contact the local Xylem service shop.
Replace the overload protection.
The pump delivers too little or no water
WARNING:
Always disconnect and lock out power before servicing to prevent unexpected startup.
Failure to do so could result in death or serious injury.
52Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 55
Troubleshooting
NOTICE:
Do NOT override the motor protection repeatedly if it has tripped. Doing so may result in
equipment damage.
CauseRemedy
The impeller rotates in the wrong
See Check the impeller rotation (page 32).
direction.
One or more of the valves are set in
the wrong positions.
• Reset the valves that are set in the wrong position.
• Replace the valves, if necessary.
• Check that all valves are correctly installed according to media flow.
• Check that all valves open correctly.
The impeller is difficult to rotate by
hand.
• Clean the impeller.
• Clean out the sump.
• Check the clearance between the propeller and the pump housing.
The pipes are obstructed.Clean out the pipes to ensure a free flow.
The pipes and joints leak.Find the leaks and seal them.
There are signs of wear on the
Replace the worn parts.
impeller, pump, and casing.
The liquid level is too low.
• Check that the level sensor is set correctly.
• Depending on the installation type, add a means for priming the pump,
such as a foot valve.
If the problem persists, refer to the Flygt Service Guide on the web or contact the local
Xylem service shop. Always state the serial number of your pump when you contact Xylem,
see Product Description (page 10).
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual53
Page 56
Technical Reference
Technical Reference
Product overview
Axial-flow pump for transportation of large volumes of water and wastewater at low heads.
Installation
L-installation
Accessories
Mechanical accessories which are available include the following:
• Cable handling system
• Lifting equipment
Electrical accessories which are available include the following:
• Pump controller
• Control panels
• Starters
• MiniCAS-II monitoring
See your Xylem representative for further information.
Options
The following options are available:
• Zinc anodes for corrosion protection in sea water
• Special coating system (with epoxy base coat) for demanding environments
The following table describes the two variants of paint systems available for the pump,
Standard and Special. The choice of coating system depends upon the service
environment.
Special (option)Epoxy, 2 layersOxirane ester, 2–pack, 1
M0516.2637.04——
Oxirane ester, 2–pack120–350 μm
or
alkyd (solventborne)
layer
ASTM/AISI 431
350–700 μm
Other coating systems are available for special requirements such as drinking water, high
temperature or erosion applications. See the Xylem internal standard M0700.00.0001
(Coating Selection Guidelines).
Mounting-related data
Depth of immersion
The maximum depth of immersion is 20 m (65 ft.).
Weight
The P7030 weighs 450 kg, excluding cables.
Cables
®
SUBCAB
Engineering data
Performance curves, motor data and dimensional drawings are available from your Xylem
representative.
Pump (ball-) throughlet
Table 7: P7030
PumpThroughlet
P7030642.52
Maximum voltage 600–1000 V, intended for drive units up to 1.1 kV. To be
dimensioned by Xylem.
mmin.
Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual55
Page 58
Technical Reference
PumpThroughlet
P7035
P7040793.11
Operational data
Application limits
Table 8: Process data
ParameterValue
Liquid temperatureMax. +40°C (+105°F)
Depth of immersionMax. 20 m (65 ft.)
pH of pumped liquidpH 5.5–14
Liquid densityMax. 1100 kg/m3 (9.17 lb per gal.)
Motor Data
Motor characteristics
Insulation classH (+180°C, +356°F)
Voltage variationMax. +/- 10%
Voltage imbalance between phasesMax. 2%
Number of starts per hourMax. 30
mmin.
501.97
Frequency
Pump50 Hz60 Hz
7030.090, 7030.180XX
7035.090, 7035.180XX
7040.090, 7040.180XX
The monitoring equipment
MiniCAS II
The table below shows the parameters which can be tracked with the MiniCAS II
monitoring system.
ParameterSensorStandard or optional
Stator winding temperatureOne of the following choices:
Leakage in the inspection chamberFloat Switch Leakage Sensor (FLS)Standard
Leakage in the junction boxFloat Switch Leakage Sensor (FLS)Optional
Standard
• 3 thermal switches (standard), or
• 3 PTC-thermistors (optional)
56Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
58Flygt P7030, P7035, P7040 Installation, Operation and Maintenance Manual
Page 61
Page 62
Xylem |’zīləm|
1) The tissue in plants that brings water upward from the roots
2) A leading global water technology company
We're 12,500 people unified in a common purpose: creating
innovative solutions to meet our world's water needs. Developing new
technologies that will improve the way water is used, conserved, and
re-used in the future is central to our work. We move, treat, analyze,
and return water to the environment, and we help people use water
efficiently, in their homes, buildings, factories and farms. In more than
150 countries, we have strong, long-standing relationships with
customers who know us for our powerful combination of leading
product brands and applications expertise, backed by a legacy of
innovation.
For more information on how Xylem can help you, go to xyleminc.com
Xylem Water Solutions AB
Gesällvägen 33
174 87 Sundbyberg
Sweden
Tel. +46-8-475 60 00
Fax +46-8-475 69 00
http://tpi.xyleminc.com
882901_3.0_en.US_2012-06_IOM.7030.7035.7040
Visit our Web site for the latest version of this
document and more information
The original instruction is in English. All nonEnglish instructions are translations of the original
instruction.