Flybox Fuel L-P Installation And User Manual, Safety Instructions And Warning Booklet

FLYBOX
®
1
®
Flybox
Omnia57 Fuel L-P - Installation and User Manual,
(Omnia57 family)
Safety Instructions and Warning Booklet
Rev. 1.0
Installation and User Manual, Safety
Instructions and Warning Booklet
This product is not TSO’d and cannot be installed into
traditional FAA Part 23 and similarly Type-Certificate Aircraft
Document A2019FUEL L-P
Revision#1.0, 02/2019
For firmware version 1.0
SECTIONS
INTRODUCTION
IMPORTANT NOTICE AND WARNINGS
INDEX
OMNIA57 FAMILY SYSTEM OVERVIEW
MECHANICAL INSTALLATION
ELECTRICAL INSTALLATION
INSTRUMENT SETTINGS
OPERATING INSTRUCTIONS
TECHNICAL SPECIFICATIONS
WARRANTY
DISCLAIMER
Examples of different configurations
®
Introduction
Thank you for purchasing a Flybox® Omnia57 instrument.
Our intent in developing the Omnia57 instrument family was to create a light and compact product, powerful and easy to install and use.
The Omnia57 instrument family is equipped with a state-of-the-art highly visible display, a powerful 32 bit microcontroller and the latest generation of solid state sensors to ensure reliability and accuracy over time.
The owner has the possibility to keep the instrument software up-to-date by downloading the latest available revision from the www.flyboxavionics.it website and installing it using a USB pen drive.
We are confident our products will be satisfactory and will make your flying experience a pleasant one.
FLYBOX
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
FLYBOX
®
Symbols used in the Installation and User Manual,
Safety Instructions and Warning Booklet
NOTE: Used to highlight important information.
CAUTION: Used to warn the user, it indicates a
potentially hazardous situation or improper use of the product.
WARNING: Used to indicate a dangerous situation that can cause personal injury or death if the instruction is disregarded.
Important notices & warnings
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
®
Important notices & warnings
WARNING: These instructions must be provided to users
before use, and retained for ready reference by the user. The user must read, understand (or have explained) and heed all instructions and warnings supplied with this product and with those products intended for use in association with it. Always keep a copy of the Installation and User Manual, Safety Instructions and Warning Booklet on the aircraft. In case of change of ownership, the Installation and User Manual, Safety Instructions and Warning Booklet must be delivered together with all of the other papers.
WARNING: Read the Installation and User Manual, Safety Instructions and Warning Booklet before installing the device on your aircraft and follow the procedure described therein.
WARNING: This device is intended to be installed on NON-TYPE CERTIFIED AIRCRAFT ONLY, as it does NOT require any air operator’s certificate. Refer to your national aviation authorities to check if this device can be installed on your aircraft.
FLYBOX
WARNING: It is the owner’s responsibility to test this device before operating the aircraft and to make sure nobody is using it unless properly instructed and authorized to do so.
WARNING: Once the installation process is completed, it is extremely important to test the device before taking off to make sure it works properly. Therefore, we strongly suggest to double check all of the electronic instruments available on the aircraft and to turn them on to verify they function correctly.
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
FLYBOX
®
WARNING: This device is operated through a software which from time to time can be updated and/or subject to change. Please, always refer to the Installation and User Manual, Safety Instructions and Warning Booklet for the last updated version of the software available at www.flyboxavionics.it
WARNING: It is the responsibility of the installer to properly install the device on the aircraft. In case of calibration, or any technical or functional customization of the device, the responsibility lies with the individual who carried out such operation.
FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY
OR DEATH.
WARNING: If this product is not used correctly, or it is
Important notices & warnings
subjected to additions or alterations, the effectiveness of this device may be considerably reduced.
WARNING: Alterations, additions, or repairs not performed by the instrument manufacturer or by a person or organization authorized by the manufacturer shall negate any warranty.
WARNING: Do NOT rely on the Omnia57 Fuel L-P device ONLY to determine the level of the fuel available in the tanks.
WARNING: The unit isn’t waterproof. Serious damage could occur if the unit is exposed to water or spray jets.
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
®
Important notices & warnings
NOTE: The consumer decides of his own free will if the
purchased product is suitable and safe for his need. If the consumer does not agree with the notices contained in this Installation and user Manual, Safety Instructions and Warning Booklet, do not install this instrument in his aircraft.
NOTE: Flybox Avionics reserves the right to change or
improve its products as well as terms, conditions, and notices under which their products are offered without prior notice.
NOTE: The Installation and User Manual, Safety Instructions and Warning Booklet will be updated annually if needed.
All changes or updates will be published on our website www.flyboxavionics.com in the "support" section.
FLYBOX
NOTE: Upon receipt of the instrument it is advisable to register on our website www.flyboxavionics.it in the "product registration" section.
The Registration data will be used only to send important news or information about available firmware updates or to communicate safety information about the instrument.
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
FLYBOX
®
i
Index
INDEX
SECTION 1 - Omnia57 Family System overview..………… 1
1.1 - Construction Features …….…………………………..…. 1
1.2 - Ergonomics………...…...………….……………………. 1
1.3 - Interconnection Ability ………...…...…………..……….. 2
1.4 - Easy Software Update ………...…...………….…………. 3
1.5 - Easy Datalog Saving ………...…...………….…………… 3
1.6 - Interfaces ……..…...…...………….……………………… 4
SECTION 2 - Mechanical installation….……………………… 5
2.1 - Mechanical Dimensions……………..….………………… 5
2.2 - Fuel Level Sensors Installation………..………………….. 7
2.3 - Important Considerations..………..………………….….. 8
SECTION 3 - Electrical Installation.…...…….….….….……… 10
3.1 - Rear Panel Connections…………..…….….………..…… 10
3.2 - 22 Pole Female Connector Wiring……………………… 11
3.3 - 22 Pole Connector Table……………………………….… 12
3.4 - Sensors Electrical Connections….…..…..…..…....……… 13
3.5 - CAN bus Connection Wiring.………….………………… 14
3.6 - CAN Bus Connector Tables……………………………… 15
SECTION 4 - Instrument settings……….………….…………. 16
4.1 - Minimum Settings Before First Use.…..….….…….…… 16
4.2 - Panel Indicators And Commands…..…….………….…. 17
4.3 - Setup Menu Navigation……….…….…..…….………… 18
4.4 - Main Setup Menu… ………………………….………… 19
4.4.1 - Gauges Submenu…….. …………………….………… 21
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
®
ii
Index
FLYBOX
4.4.2 - Televels Submenu…….. …………………….………… 22
4.4.3 - Main Tank Submenu……….……….…………………… 24
4.4.4 - Main Tank Calibration..…………………………………. 26
4.5 - Fuel Pressure Submenu.….…….……….…………….…… 35
4.6 - Backlight Submenu….………….………………………… 39
4.7 - Fuel Level Sensors Checking.…………………………… 42
SECTION 5 - Operating Instructions……….…………………… 43
5.1 - Firmware Upgrade..……………..…..….….…….………. 43
5.2 - Backup/Restore……………….…..…….………….….…. 46
5.3 - Use Of The Instrument……….…….…..…….……………. 48
5.4 - Logger…..………. ………………………….……………. 50
TECHNICAL SPECIFICATIONS…………………………… 51
WARRANTY…………………………………………………… 53
CLEANING…………………………………………………….. 51
TERM OF USE AND DISCLAIMER………………………… 54
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
FLYBOX
®
1
Omnia57 Family System Overview
OMNIA57 FAMILY SYSTEM OVERVIEW
The Omnia57 instrument family has many innovative features, common to all models as described below.
1.1 CONSTRUCTION FEATURES
Omnia57 instrument family is built from solid aluminum alloy, CNC milled and powder coated to last a long time over the years always showing a new appearance.
1.2 ERGONOMICS
- Large 2.4 inch TFT display, 320x240 Pixels, 1000 nits, antiglare surface, sunlight readable, wide temperature range.
- A high quality knob encoder with push button for easy access to all features.
- Backlight auto dimming feature with one optional sensor for all the Omnia57 installed in the panel.
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
®
2
Omnia57 Family System Overview
FLYBOX
1.3 INTERCONNECTION ABILITY
All the instruments of the Omnia57 family can be connected together to form a communication network, making some data exchange operations simpler.
The software update of a Omnia57 instrument connected in group takes place through the CAN bus communication with the instrument that has the USB pen drive connected. This means that the USB connection is made to a single instrument, and the information will be forwarded via CAN bus to or from all the others in the group.
Up to 16 Omnia57 can be connected together through the CAN 1 bus.
The configuration data and the data logger of the interconnected instruments are saved or restored via CAN bus on the same USB pen drive. A single brightness sensor can provide information to all the connected instruments to automatically adjust the backlight intensity.
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
FLYBOX
®
3
Omnia57 Family System Overview
1.4 EASY SOFTWARE UPDATE
The user can download any new firmware, when available, from Flybox website, connect a USB pen drive to the instrument and freely update it with the last features.
With one USB connection only, it will be possible to update every instrument installed in the panel. If more Omnia57 are installed and properly connected, they will search for the right firmware through the CAN bus.
1.5 EASY DATALOG SAVING
Easy logging of the data for debug purpose. If needed, each Omnia57 unit can save a last flight log on the USB pen drive. The user can then send the log via e-mail to Flybox support for a help/support request.
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
®
4
Omnia57 Family System Overview
FLYBOX
1.6 INTERFACES
All the Omnia57 instruments have the following common interfaces:
2 separate CAN BUS: they can be used to connect the Omnia57 instruments together, to interface them with
other Flybox instruments or with external devices like Engines ECUs or new devices that will be possibly developed in the future.
2 RS232 serial ports: used to connect the Omnia57 instruments to an external GPS (when applicable). This feature appears in some models only.
1 Sensor Light Input: if connected, it allows the automatic light intensity adjustment, one sensor for all the instruments.
2 Power outputs for sensors: one 12 V 500mA@60°C and the other 5 V 350 mA@60°C, both protected from short circuit.
If the current on one of the outputs is too high, a caution message will appear.
1 Alarm output: all the Omnia57 instruments can activate an external warning device like a lamp or a small relay through this NPN transistor output.
Caution!
High current PIN 2
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
FLYBOX
®
5
Omnia57 Family System Overview
MECHANICAL INSTALLATION
2.1 MECHANICAL DIMENSIONS
The Omnia57 Fuel L-P instrument fits in a standard 2 ¼” (57 mm) panel cutout; it's recommended to choose a position that permits optimal display visibility. It's furnished with four M4 screws to install it to the panel, if you use other screws consider that the maximum thread length inside the instrument body is 10mm (see the picture below).
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
®
6
Mechanical installation
FLYBOX
NOTE: For an installation without interference, consider making a hole of at least 57.5 mm diameter
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
FLYBOX
®
7
Mechanical installation
2.2 FUEL LEVEL SENSORS INSTALLATION
Omnia57 Fuel L-P has 4 fuel level inputs that can be connected to both resistive sensors (with max resistance of 300 ohm) and capacitive sensors (with output voltage range 0~5 Volt).
Resistive sensors can be of two types, both supported by the device: resistive sensors that increase resistance as you add fuel and resistive sensors that decrease resistance as you add fuel. If you don't know what type of sensors are installed please see chapter 4.7 “Fuel level sensors checkings”.
It's also possible to install a mixed type of sensors (i.e. 2 resistive + 2 capacitive).
CAUTION: All fuel level sensors connected to the Omnia57 Fuel L-P must not be connected to any other instrument.
Disconnect any previously used instrument.
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
®
8
Mechanical installation
FLYBOX
2.3 IMPORTANT CONSIDERATIONS
NOTE: Be advised that many fuel level sensors might not
be able to accurately measure the capacity of the tank and that one of the following issues might occur (please, see chapter 2.2 “Fuel level sensors installation”):
In the example of pic.1 of next page, a tank contains 7 litres but the fuel sensor cannot measure that lower part of the tank, so Omnia57 Fuel L-P will display "0" (zero) for a fuel level of 7 litres or less.
In the example of pic.2 of next page, a tank can hold 50 liters of fuel but at 35 liters the fuel sensor is at his upper position, the maximum quantity that Omnia57 Fuel L-P will display is 35 liters.
The first situation described above, or the second one, or both, can occur very often, especially for tanks installed in the wings due to the angle of dihedral.
NOTE: If your fuel sensor is not able to measure the fuel level from empty to full, while planning your flights, you may need to keep in mind the amount of fuel that the instrument is unable to measure. Keep in mind that this can happen even with an analog indicator, where the sensor can not measure, the instrument can not give
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
FLYBOX
®
9
Pic.1
Pic.2
7 LT
Mechanical installation
35 LT
Not measurableNot measurable
It takes a considerable amount of fuel before the sensor starts moving when adding fuel to an empty tank.
It takes a considerable amount of fuel before the sensor starts moving from the top when draining fuel from a filled up tank.
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
®
10
Electrical installation
FLYBOX
ELECTRICAL INSTALLATION
3.1 REAR PANEL CONNECTIONS
2 x 2 - p o l e connectors, Molex Micro­Fit for CAN 1
bus
22 pole female connector, Molex Micro-Fit. See the table chapter 3.3
Upper
Lower
Upper
Lower
2 x 2 - p o l e co n nectors, Molex Micro­Fit for CAN 2
bus
USB 2.0 port
The required connectors and terminals are supplied with the instrument.
The manufacturer’s codes are:
Molex P/N 43025-0200 (2 pole housing) Molex P/N 43025-2200 (22 pole housing) Molex P/N 43030-0007 (female crimp terminal)
The terminals can be crimped with:
- Flybox Professional Crimping Tool cod. 603000
- Molex tool P/N 63819-0000
Omnia57 Fuel L-P - Installation and User Manual,
Safety Instructions and Warning Booklet
Rev. 1.0
Loading...
+ 47 hidden pages