FLY E145 Service Manual

T69_Maintenance Instruction
Prepared by : xiaoyu wan Approved by: Date: 2009-11-02
TABLE OF CONTENTS
No power on Shut off automatically
Dead halt No charge Quantity of electricity faulty detection No display LED NG (on the LCD) LED NG (on the keyboard) Key NG No ring No receiving voice
Innovating Customer Value
No sending voice or the voice is small No vibration SIM Card inefficacy Camera inefficacy Bluetooth inefficacy TF card inefficacy Earphone inefficacy FM inefficacyG-senser inefficacy
2
Battery CONN
Adapter CONN
TF card
BT area
Camera FPC
Antenna
Earphone CONN
Socket of SIM card
CPU
Flash
RF PA
Transceiver
Audio PA
K/B FPC
FM area
Power supply chip
LCD
Receiver
G_senser
¾No power on
No power on
Check whether the
battery voltage is
higher than 3.4V
Y
Check whether the battery and the key pad of
oxidized or there is
anything else on it
N
Check whether the
connection of K/B &
M/B is OK
N
Take out the LCD and
SPK, Check whether it is
powered on
J404 is
N
Y
Y
Y
Charge the battery
Wipe off the thing
or clean the key pad
reweld the K/B
Cross-testing the
LCD&SPK,
Change the defective
N
A
5
A
C127:2.8V, the capacitor: C127; C128:2.8V, the capacitor: C128: C139:2.8V, the capacitor: C129; C130:2.8V, the capacitor: C130; C131:2.8V, the capacitor: C131; C133:1.5V, the capacitor: C133.
\Check whether
D501,R548(10K) is
broken
N
Connect with the battery,
press “NO” key, check
whether the output voltage
of U
101 is normal
Y
Check whether the
output frequency of
X100 is 32.768K
Y
Check whether the
output voltage of U
pin3 is
1.13V around
605
Y
Change the
FLASH(
U300) of the
main module, check
whether it is OK
Y
Change D501,R548
Replace a earthed
N
capacitor corresponding to
the defective pin, Check
N
Change U101
whether it is OK
N
Change X100,
C100,C101
N
Check whether U604
pin
16 has an voltage
Y
Change U605
of 2.8V around
N
Change U101
N
Change the
CPU(U100)
OK
Innovating Customer Value
7
Innovating Customer Value
8
¾Shut off automatically
Innovating Customer Value
Shut off
automatically
D/L the latest edition,
Check whether it is OK
N
Replace with a
good battery, Check
whether the
primary cell is broken.
N
Check whether the
rubber, used to fix the
battery, is lost or at the
other location
N
Check whether the battery and the key pad of J
oxidized or there is
anything else on them
407 is
Y
Y
Change the battery
Y
Y
Reassemble the
Wipe off the thing
or clean the key pad
OK
rubber
N
C
13
Innovating Customer Value
C
Check whether the
battery connector
void-welded or broken
N
Check whether the
connection of
&K/B FPC is OK,FPC is
void-welded
Y
Check whether there
is any pin of the
connector
( M/B &K/B) broken
N
Check whether X100
output frequency is
32.768K exactly
‘J407’ is
J408
J404
Y
N
Y
N
Re-weld or
change J501
Reassemble the K/B
Or change the FPC
Change J404
ChangeX100,
C100,C101
Y
Refer to the maintenance
method of ‘No power on’
OK
14
Innovating Customer Value
15
¾Dead halt
Innovating Customer Value
Death halt
D/L the latest edition,
Check whether it is OK
N
Replace with a good
battery, Check whether
the primary cell is broken
N
Check whether the problem is resulted
from ‘KEY NG’
N
Check whether the problem is resulted from the LCD itself
Y
Y
Y
Y
Change the battery
reassemble or change
OK
Clean the K/B, the metal dome
Change the LCD
N
D
16
Innovating Customer Value
D
Check whether the
output frequency of
X100 is 32.768 exactly
Y
Check whether the
connection of
&K/B FPC is OK,FPC is
void-welded
Y
Check whether there is
any pin of the connector
J404’ ( M/B &K/B)
broken N
Replacing with the
programming FLASH,
check whether it is OK
J404
N
Re-weld or change
X100,C100,C101
N
Y
Reassemble or
change the FPC
Change J404
N
Refer to the servicing
method of ‘No power on’
OK
17
¾No charge
No charge
Replace with a
good battery, Check
whether the
primary cell is broken.
N
Replace with a good
adaptor, Check
whether the primary
adaptor is broken
N
Innovating Customer Value
Y
Y
Change the battery
Change the adaptor
Check whether the
battery connector
is oxidized or is broken
N
Check whether the
connector
void-welded or
broken
N
E
‘J407
J304’ is
Y
Y
Clean or
change J
Re-weld or
change
407
J304
18
E
Plug in, Check whether
it has an voltage of 1V
R
Y
115
114 and
between R
Innovating Customer Value
N
Change R114(24K),
R115(100K)
Check whether there
is anyone broken of
R118A~R118D(100K)
Y
Check whether there
is anyone broken of
Q100,R100
N
Change U101, check
whether it is OK
N
Change the
CPU(U100)
N
Y
Change the defective
Change Q100,
R100(0.39ohm)
OK
19
¾Quantity of electricity faulty detection
Quantity of electricity
faulty detection
Replace with a
good battery, Check
whether the
primary cell is broken.
Innovating Customer Value
Y
N
Change the battery
Check whether there is
anyone broken of
R118D(100K)
N
Change U101, check
whether it is OK
N
Change the CPU
OK
R118A-
Y
Change the battery
20
Loading...
+ 36 hidden pages