![](/html/d1/d16a/d16a599b9b38e77e28dd180b415c39e9b3d8021ea92a99d062905611cf0f6f26/bg1.png)
User’s Manual Mini Infrared Thermometer
1. Introduction
Congratulations on your purchase of our professional non-contact infrared thermometers.
These units can provide fast, easy and accurate temperature readings. With the non-contact (infrared) technology, they can
be used to measure the surface temper ature of hard-to-reac h objects like electrified equipment or moving objects without
any damage or pollution to them.
2. Features
● Fast and easy m easurement ● Precise non-contact measurement
● The built-in laser pointer increases the target accuracy ● Adjustable em issivity: 0.1~1.0
● Max/Min record ● Backlight LCD display
● Automatic tr igger off ● Auto power off
● Automatic m easurement range sele ction with resolution 0.1℃/0.1℉﹤1000 1℃/1℉≥1000
3. Application
These unit s are widely used in Food preparation, Safety and Fire inspection, Plastic molding , Asphalt, Mar ine, Printing ink
and dryer temperature, Diesel and Fleet maintenance, etc.
4. Safety
● Use extreme caution when the lase r beam is turned on.
● Do not point the beam toward anyone or any animals.
● Do not allow the beam to strike the eye from a reflective surface.
● Do not use the laser near explosive gases.
Safety Symbol
Comply with EMC
5. Field of View
The meter's field of view is 30:1, for example, if the m eter is 30 inches
from the target spot, the diameter of the target m ust be at least 1 inch.
Other distance ratios are shown below in the field of view diagram.
-50℃~0℃/-58℉~32℉:±4℃/9℉; Above 0℃/32℉:1.5% ±2℃/4℉
0.1℃/0.1℉﹤1000 1℃/1℉≥1000
-20℃ to 60℃ / -4℉ to 140℉
Operating:10 to 95%RH Storage:<80%RH
Auto shuts off after 20Sec. of inactivity
Auto display, "-" indicates negative, while positive with no sign.
Output<1mW,630~670nm, class 2(Ⅱ)
7. Meter Description
A. Laser Pointer Beam B. IR Sensor
C. LCD Display D. ℃/℉ Switch Button
E. Laser pointer/Backlit Button F. MODE Button
G. Measurement Trigger H. Battery Compartment Cover
8. LCD Display Description
○
1 Me asurement Icon
○
2 Data Hold Icon
○
3 Em issivity Icon
○
4 Backlit Icon
○
5 Las er Icon
○
6 Low Battery Indication
○
7 Temperature Unit (℃/ ℉)
○
8 Max/Min Record
○
9 Me asurement Reading
○
10 Max/Min Icon
![](/html/d1/d16a/d16a599b9b38e77e28dd180b415c39e9b3d8021ea92a99d062905611cf0f6f26/bg2.png)
9. Operating Instruction
A. Operating steps:
○
1 Hold the meter by its handle grip and point it toward the surface to be measured.
○
2 Pull and hold the Trigger to turn the meter on, the "SCAN" icon will appear and begin testing.
○
3 The surface temperature being tested will be displayed on the LCD screen.
○
4 Release the trigger, the "HOLD" icon will appear, and the reading will be held for several seconds.
○
5 The meter will automatically shut off after 20 seconds of inactivity.
Measurement Note: If the meter used in an ambient temperature with wide temperature change, awaiting at least 30
minutes to adjust it.
The laser is designed for aiming only; it can be shut off while operating in short distance to save the battery.
B. Button Function
℃/℉button: In Measurement Mode, press button “ ”to switch the temperature unit ℃ or ℉.
Laser pointer/Ba cklight button: In Measurement Mode, press button " " to turn on/off backlig ht; In “HOLD” Mode,
press button “ ” to turn on/off laser pointer.
During measuring, press button “ ” to display MAX/MIN readings.
During m easuring, press button “ ” until“ ”icon flashes on the screen, then loose button“ ”, enter into
Emissivity Mode, press button “ ” and“ ”to adjust emissivity value, then keep pressing button " " return
to the normal measurement mode.
C.Battery Replacem ent
○
1
When the low battery icon“ ”appears, replace the meter's battery.
○
2
Open the battery compartment, replace the 9V battery and close the battery compartment
10. Notes
⑴ Work Principle
● The infrared thermometer is designed for measuring surface temperature of an object.
● The optical sensor can emit, reflect and transmit energy, which is collected and focuse d on a detector, then translate it
into the temperature reading by electronics and displayed on the LCD screen.
● The laser is used for aiming the target object only.
⑵ Field of View
● The object under test should be larger than the spot size calculated by the field of view diagram.
● The smaller the target object is, the closer the meter should be to it for accurate measuring.
● When accuracy is critica l, make sure the target is at least twice as large as the spot size.
⑶ Distance & Spot Size
● As distance (D) from the object incr eases, the spot size (S) of the area measured by the unit becomes larger.
⑷ Locating a hot spot
● To find a hot spot, first aim the thermometer to the outside of target area, then scan across in a n up and down motion
until the hot spot is located.
⑸ Notice
● Not recommend for measuring shiny or polished metal surfaces like stainless steel, aluminum, etc.
● Do not make m easurement through transparent surface suc h as glass.
● If the surface of the object under test is covered with frost, oil, grime, etc., clean before taking measurement.
⑹ Maintenan ce
● Do not use volatile liquids to clean the unit, swipe it with dry soft cloth.
● Do not disassemble the unit, repair it by qualified personnel
● Do not immerse it in water.
● Do not store it in high temperature or humidity.
⑺ Emissivity
● Most (90%) organic ma terials and painted or oxidized surfaces have an emissivity of 0.95 (pre-set in the unit).
11. Accessories
● User's manual ● 9V Battery
Emissivity Table