2. Features
● The built-in laser pointer increases the target accuracy ● Adjustable em issivity: 0.11.0
● Max/Min record ● Backlight LCD display
● Automatic tr igger off ● Auto power off
● Automatic m easurement range sele ction with resolution 0.1/0.1℉﹤1000 1/1≥1000
3. Application
These unit s are widely used in Food preparation, Safety and Fire inspection, Plastic molding , Asphalt, Mar ine, Printing ink
and dryer temperature, Diesel and Fleet maintenance, etc.
4. Safety
● Use extreme caution when the lase r beam is turned on.
● Do not point the beam toward anyone or any animals.
● Do not allow the beam to strike the eye from a reflective surface.
● Do not use the laser near explosive gases.
Safety Symbol
Comply with EMC
5. Field of View
The meter's field of view is 30:1, for example, if the m eter is 30 inches
from the target spot, the diameter of the target m ust be at least 1 inch.
Other distance ratios are shown below in the field of view diagram.
6. Specifications
Range
-50℃~650;-58℉~1202
-50℃~850;-58℉~1562
-50℃~1050;-58℉~1922
Accuracy
-50℃~0/-58℉~32℉:±4/9; Above 0/32:1.5% ±2/4
Optical Resolution
D:S=30:1
Emissivity
Adjustable: 0.101.0
Resolution
0.1/0.1℉﹤1000 1/1≥1000
Response Time
250 ms
Spectral Response
814um
Operating Temp.
0to 50/ 32to 122
Storage Temp.
-20to 60/ -4to 140
Relative Humidity
Operating:10 to 95%RH Storage:80%RH
Auto Power Off
Auto shuts off after 20Sec. of inactivity
Polarity Display
Auto display, "-" indicates negative, while positive with no sign.
Diode Laser
Output1mW630670nm, class 2()
Power Supply
9V battery
Weight
171g
Dimensions(L*W*H)
155.5*98.8*27.5mm
7. Meter Description
A. Laser Pointer Beam B. IR Sensor
C. LCD Display D. /Switch Button
E. Laser pointer/Backlit Button F. MODE Button
G. Measurement Trigger H. Battery Compartment Cover
8. LCD Display Description
1 Me asurement Icon
2 Data Hold Icon
3 Em issivity Icon
4 Backlit Icon
5 Las er Icon
6 Low Battery Indication
7 Temperature Unit (/ )
8 Max/Min Record
9 Me asurement Reading
10 Max/Min Icon
9. Operating Instruction
A. Operating steps:
1 Hold the meter by its handle grip and point it toward the surface to be measured.
2 Pull and hold the Trigger to turn the meter on, the "SCAN" icon will appear and begin testing.
3 The surface temperature being tested will be displayed on the LCD screen.
4 Release the trigger, the "HOLD" icon will appear, and the reading will be held for several seconds.
5 The meter will automatically shut off after 20 seconds of inactivity.
Measurement NoteIf the meter used in an ambient temperature with wide temperature change, awaiting at least 30
minutes to adjust it.
The laser is designed for aiming only; it can be shut off while operating in short distance to save the battery.
B. Button Function
1
/button: In Measurement Mode, press button “ ”to switch the temperature unit or ℉.
2
Laser pointer/Ba cklight button: In Measurement Mode, press button " " to turn on/off backlig ht; In “HOLD” Mode,
press button “ ” to turn on/off laser pointer.
3
During measuring, press button “ ” to display MAX/MIN readings.
During m easuring, press button “ ” until“ ”icon flashes on the screen, then loose button“ ”, enter into
Emissivity Mode, press button “ ” and“ ”to adjust emissivity value, then keep pressing button " " return
to the normal measurement mode.
C.Battery Replacem ent
1
When the low battery icon“ ”appears, replace the meter's battery.
2
Open the battery compartment, replace the 9V battery and close the battery compartment
10. Notes
Work Principle
● The infrared thermometer is designed for measuring surface temperature of an object.
● The optical sensor can emit, reflect and transmit energy, which is collected and focuse d on a detector, then translate it
into the temperature reading by electronics and displayed on the LCD screen.
● The laser is used for aiming the target object only.
Field of View
● The object under test should be larger than the spot size calculated by the field of view diagram.
● The smaller the target object is, the closer the meter should be to it for accurate measuring.
● When accuracy is critica l, make sure the target is at least twice as large as the spot size.
Distance & Spot Size
● As distance (D) from the object incr eases, the spot size (S) of the area measured by the unit becomes larger.
Locating a hot spot
● To find a hot spot, first aim the thermometer to the outside of target area, then scan across in a n up and down motion
until the hot spot is located.
Notice
● Not recommend for measuring shiny or polished metal surfaces like stainless steel, aluminum, etc.
● Do not make m easurement through transparent surface suc h as glass.
● If the surface of the object under test is covered with frost, oil, grime, etc., clean before taking measurement.
Maintenan ce
● Do not use volatile liquids to clean the unit, swipe it with dry soft cloth.
● Do not disassemble the unit, repair it by qualified personnel
● Do not immerse it in water.
● Do not store it in high temperature or humidity.
Emissivity
● Most (90%) organic ma terials and painted or oxidized surfaces have an emissivity of 0.95 (pre-set in the unit).
11. Accessories
● User's manual ● 9V Battery
Emissivity Table
Substance
Thermal emissivity
Substance
Thermal emissivity
Aluminum
0.30
Glass
0.90 to 0.95
Asphalt
0.95
Iron oxides
0.78 to 0.82
Concrete
0.95
Lacquer
0.80 to 0.95
Leather
0.95
Plastic
0.85 to 0.95
Ceramic
0.95
Paper
0.70 to 0.94
Copper
0.50
Sand
0.90
Brick
0.90
Rubber
0.95
Carbon
0.85
Timber
0.94
Fat-lute
0.94
Textiles
0.94
Frozen food
0.90
Lead
0.50
Hot food
0.93
Marble
0.94
Ice
0.98
Cloth(black)
0.98
Snow
0.90
Plaster
0.8 0to 0.90
Human skin
0.98
Water
0.93