Fluke Networks DSX-PC5ES, DSX-PC6S, DSX-PC6AS User Manual

DSX-PCxx
Patch Cord Adapters
Users Manual
February 2014, Rev. 1 3/2018 ©2014, 2018 Fluke Corporation All product names are trademarks of their respective companies.

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke Networks product is warranted to be free from defects in material and workmanship under normal use and service unless stated otherwise herein. The warranty period for the mainframe is one year and begins on the date of purchase. Parts, accessories, product repairs and services are warranted for 90 days, unless otherwise stated. Ni-Cad, Ni-MH and Li-Ion batteries, cables or other peripherals are all considered parts or accessories. The warranty extends only to the original buyer or end user customer of a Fluke Networks authorized reseller, and does not apply to any product which, in Fluke Networks’ opinion, has been misused, abused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke Networks warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non­defective media. Fluke Networks does not warrant that software will be error free or operate without interruption.
Fluke Networks authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke Networks. Warranty support is available only if product is purchased through a Fluke Networks authorized sales outlet or Buyer has paid the applicable international price. To the extent permitted by law, Fluke Networks reserves the right to invoice Buyer for repair/replacement when a product purchased in one country is submitted for repair in another country.
For a list of authorized resellers, visit www.flukenetworks.com/wheretobuy. Fluke Networks warranty obligation is limited, at Fluke Networks option, to refund of the purchase price,
free of charge repair, or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke Networks authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB destination). Fluke Networks assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB destination). If Fluke Networks determines that failure was caused by neglect, misuse, contamination, alteration, accident or abnormal condition of operation or handling, or normal wear and tear of mechanical components, Fluke Networks will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping point).
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE NETWORKS SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.
4/15
Fluke Networks PO Box 777 Everett, WA 98206-0777 USA

Contents

Title Page
Introduction .....................................................................................................1
Kit Contents ......................................................................................................1
DSX-PC5ES ...................................................................................................1
DSX-PC6S .....................................................................................................1
DSX-PC6AS ..................................................................................................1
Contacting Fluke Networks .............................................................................2
Additional Resources for Cable Testing Information ....................................2
WSafety Information ..................................................................................2
DSX Software Requirements ...........................................................................3
Characterize the Performance of the Adapters .............................................3
How to Do Tests on Patch Cords .....................................................................3
How to Set Up the Tester ...........................................................................3
How to Do the Patch Cord Test ................................................................. 5
Patch Cord Test Results ....................................................................................6
Why Patch Cords Fail .................................................................................. 6
Wire Map Failures .................................................................................7
Return Loss Failures ...............................................................................7
NEXT Failures .........................................................................................7
Is the Cable Bad or is the Plug Bad? ..........................................................8
Mechanical Stress Tests for Patch Cords .........................................................10
When to Replace the Jacks in the Adapters ...................................................10
How to Monitor the Number of Insertions for a Jack .............................. 11
How to Order Replacement Jacks .............................................................. 11
i
DSX-PCxx Patch Cord Adapters
Users Manual
Replacement Parts ...................................................................................... 11
How to Replace the Jacks .......................................................................... 12
Specifications ...................................................................................................13
Appendix A: How to Characterize and Verify the Adapters’ Performance ..15
ii

Introduction

The DSX-PCxx Patch Cord Adapters let you use a DSX CableAnalyzer™ tester to
make sure that patch cords comply with ANSI/TIA and ISO/IEC standards. The
adapters have RJ45 jacks that Fluke Networks selects specifically for tests on Cat
5e and 6 patch cords as specified in TIA-568-C.2 and IEC 61935-2, and Cat 6A patch
cords as specified in IEC 61935-2.
Standards organizations can add amendments to standards. Contact the applicable standards organization for details. For general information on standards and for DSX software updates that include updated standards, contact Fluke Networks.

Kit Contents

A DSX-PCxxS Patch Cord Adapter Set comes with these items:
Note

DSX-PC5ES

Two DSX-PC5E Cat 5e Patch Cord Adapters
DSX-PCxxS Product Manuals CD-ROM

DSX-PC6S

Two DSX-PC6 Cat 6 Patch Cord Adapters
DSX-PCxxS Product Manuals CD-ROM

DSX-PC6AS

Two DSX-PC6A Cat 6A Patch Cord Adapters
DSX-PCxxS Product Manuals CD-ROM
If something is missing or damaged, contact the place of purchase immediately.
1
DSX-PCxx Patch Cord Adapters
Users Manual

Contacting Fluke Networks

Note
If you contact Fluke Networks about your tester, have the
tester's software and hardware version numbers available if
possible.
www.flukenetworks.com/support
info@flukenetworks.com 1-800-283-5853, +1-425-446-5500
Fluke Networks 6920 Seaway Boulevard, MS 143F Everett WA 98203 USA
Fluke Networks operates in more than 50 countries worldwide. For more contact information, go to our website.

Additional Resources for Cable Testing Information

For more information on the DSX CableAnalyzer, see the Versiv Series manuals available on the Fluke Networks website.
The Fluke Networks Knowledge Base answers common questions about Fluke Networks products and provides articles on cable testing techniques and technology.
To access the Knowledge Base, log on to www.flukenetworks.com, then click SUPPORT > Knowledge Base.

WSafety Information

WWarningX
To prevent possible fire, electric shock, personal injury,
damage to equipment, or inaccurate test results, read the
safety information in the Versiv Series manuals before you
use the tester.
2

DSX Software Requirements

The DSX main and remote testers need Versiv software version 2.3 or later to do
tests with the DSX-PCxx adapters.
To see the software versions in your main and remote testers
1
Connect the main and remote testers together with permanent link and channel adapters or two channel adapters and a patch cord.
2
Turn on both testers.
3
On the main tester tap TOOLS, then Version Information.
The latest DSX software version is available at no charge on the Fluke Networks
web site. Download the update file from the website, then use LinkWare™
software to install new software into the DSX testers. See the Versiv Series
manuals or the online help in LinkWare for instructions.
DSX Software Requirements

Characterize the Performance of the Adapters

When you first get the patch cord adapters, characterize their performance.
Later, the test results can help you see if the adapters need new jacks. See
Appendix A.

How to Do Tests on Patch Cords

WCaution
Testing patch cords that have poorly crimped plugs can reduce the life of the patch cord adapter's jacks or make them unusable.

How to Set Up the Tester

1
Attach the DSX-PCxx adapters to the main and remote DSX testers.
2
On the home screen, tap the test setup panel.
3
On the CHANGE TEST screen, tap NEW TEST.
-continued-