Fluke Calibration Fluke Calibration 2638A/05 120 Brochure

99 Washington Street Melrose, MA 02176
Phone 781-665-1400 Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
Data Acquisition
Where you need it When you need it How you need it
• Accurate
• Flexible
• Easy-to-use
• Portable
• Expandable to thousands of channels
Fluke data acquisition solutions adapt to your needs
Get the data you want, where, how and when you want it.
Fluke gives you a broad choice in how you collect and transfer data for process monitoring and laboratory test systems. You can choose a stationary or portable system. Transfer data to internal memory, to a removable memory card, or to your PC. Choose a standalone or distributed networked units. And you can expand your system from 20 to more than 2,000 channels.
Regardless of which you choose you’ll always get Fluke’s well known accuracy, reliability, speed, and ease of use. All Fluke data acquisition products feature unique, built-in universal signal condi­tioning and a plug-in Universal Input Module to enable you to measure virtually any type of signal without having to purchase extra equipment. Plus, powerful FlukeDAQ application software supports easy configuration, trend analysis, remote viewing, email notifications and enables you to quickly build human-machine-interfaces without any programming.
Any data acquisition application that requires high accuracy, easy setup, and convenience calls for Fluke data acquisition products, which is why you’ll find them widely used for:
R &D applications
Environmental testing
Product testing and process validation
Troubleshooting
Manufacturing test systems
Whether you’re gathering data at a high-voltage substation, a nuclear power plant, in a clean room, on a production line, or on an automotive test track, Fluke data acquisition products can make your job easier by delivering the data you need, when and where you need it.
Accuracy, flexibility and ease of use come standard
From a single 20 channel Hydra™ Series III portable data logger to a 2,000+ channel preci­sion temperature measurement 2680A data acquisition system, Fluke data acquisition prod­ucts share several unique advantages.
Built-in signal conditioning saves time and
money. Fluke’s data acquisition
products were the first to integrate signal
conditioning directly into the instrument.
Assign any measurement function— thermo-
couple, RTD, volts, frequency, or ohms—to
any or all channels.
Removable universal input module
connects any signal. Our unique, patented
Universal Input Module allows you to connect
and measure virtually any electrical or phys-
ical parameter. Thermocouple reference junc-
tion compensation occurs automatically by
sensing the temperature of the input module’s
isothermal block. Virtually any combination of
sensor or signal lines may be connected to the
input module, which is plugged into the back
of the data acquisition unit. You can pre-wire
extra input modules at each test site and move
your data acquisition units from one location to
another.
Rugged design for reliable performance.
Fluke data acquisition products are designed
to stand up to rugged industrial environ-
ments with some models operating from -20°C
to 60°C. A sturdy metal chassis effectively
shields against electromagnetic interference so
you can maintain high measurement accuracy
on low-level signals regardless of surrounding
noise. They are tested to stringent shock and
vibration standards and to withstand surges of
up to 1500 V input on most models. All units
conform to IEC, CSA, and CE standards.
Isolated circuitry for top accuracy. Fluke analog measurement circuitry is fully isolated channel to channel, input to output, and input to ground, supporting direct measurement of voltages up to 300 V ac rms and are certified to international Category II electrical safety standards
Scan triggers, including interval, push button, external, and alarm triggers, scan all defined channels.
Mx+B scaling is available on each channel.
Math Channels. All Fluke data acquisition
products have available math channels to allow real-time calculations to your data file based on results of other channel readings.
Two alarms can be set for each channel.
Real-time clock offers precise time stamping
of data.
Closed-case calibration delivers reliability and traceability.
2
The Fluke 2680 Series: Precise and versatile standalone or networked data acquisition
The Fluke 2680 Series delivers the precision necessary for meticulous lab work along with the rugged flexibility to meet the ever changing needs of industrial applications. Run one standalone data logging system with 20 to 120 universal chan­nels or connect several networked data acquisition systems to serve 2,000+ channels on your LAN.
The Fluke Hydra™ Series III: Price-performance breakthrough in a stand-alone data acquisition system
The Fluke Hydra Series III brings a new dimension to viewing data on your instrument with its graph color display with real-time charting capabilities. Measurement accuracy at 0.0024 % continues the Hydra series legacy of precision, multichannel data acquisition.
The Fluke NetDAQ® Series: Distributed, networked data acquisition that works with what you have
Distributed Fluke NetDAQ units plug right into your existing networks to send data directly to a PC. This saves the cost of setting up a new network and allows multiple users to simultaneously view data in real time. NetDAQ units can also be used as a portable dedicated system connected to a laptop computer for maintenance, product validation,
Hydra Series III NetDAQ 2680 Series
Universal signal conditioning
Basic dc accuracy
PC interface USB; Ethernet Ethernet Ethernet
Channels per mainframe/ system
Max channels/ second
research, and troubleshooting applications.
Yes Yes Yes
0.0024 % 0.01 % 0.01 %
66/2000+ 20/2000+ 120/2000+
46 1000 1000
Versatile software for easy setup
Powerful, flexible, and easy-to-use Fluke DAQ software (2680A-APSW) included with
every 2680 Series and NetDAQ models, and makes it easy to instantly configure your Fluke Data Acquisition System with any mix of Hydra SeriesIII, NetDAQ or 2680A Series product. Over 2000 channels can be configured with this system. Fluke DAQ software can schedule and record scan data to remote file locations, allow multiple viewing via web browser and email alerts to operators.
Optional Trend Link for Fluke software
provides comprehensive trend plotting, batching, and analysis capabilities for the Hydra SeriesIII, NetDAQ and 2680A systems using Fluke DAQ software. It combines the look and feel of a chart recorder with the analytical power of a PC.
33
2638A Hydra Series III Data Acquisition System
The Fluke 2638A Hydra Series III: Key features
DC accuracy of 0.0024 %
• Thermocouple accuracy of
0.5°C
Up to 66 universal differential isolated inputs
On-screen color trend graphing of up to four channels at a time
asy-to-use menu system for
E setup and data management
ulti-channel real-time data
M display
nput types: ac V, dc V, ac I, dc
I I, thermocouple, PRT (2, 3, 4 w), thermistor, resistance (2-4 w), frequency
.5-digit bench DMM function
6 for front-panel inputs
onitor function for real-time
M viewing and charting between scans
20 on-board math channels
One-button screen capture of chart or data displays
6 channels/second basic dc
4 scan rate
nternal 75,000 scan/setup file
I memory
USB flash drive support
Data security features
CAT II 300 V input safety rated
Industrial grade, precision data acquisition
DC measurement accuracy of
0.0024%, basic 0.5 °C thermo­couple accuracy, full-color display, easy-to-use menu system and international Category II safety ratings put the 2638A in a category of its own as a truly industrial grade, precision data acquisition system. The dedicated 6.5 digit digital multimeter (DMM) mode adds additional utility and value.
The 2638A is expandable from 22 to 66 channels of differential analog inputs. A flexible, 22-channel Universal Input Connector lets you connect and disconnect any type of input to any channel, quickly and easily. Selectable inputs include dc voltage, ac voltage, resistance, ther­mocouple, RTD, thermistor, frequency and dc and ac current. You can also use the 2638A with FlukeDAQ soft­ware and other Fluke data loggers to create a flexible, customized data acquisition system with an almost unlimited number of channels.
4
Universal input connector
The 2638A incorporates the Fluke Universal Input Connector to bring more accuracy to thermocouple measurements than most other instru­ments in its class. The Universal Input Connector supports 14 worldwide thermocouple types. Temperature­focused menu selections make the 2638A especially suitable for temperature validation applications. If you need to “zero” a large number of thermocouples to a known reference temperature before starting a temper­ature profiling or validation test, the 2638A will normalize all readings to your reference channel at the push of a button and store the offsets for reference in a supporting data file. If you are conducting chamber tests, heat treating tests under ASM guidelines, or validating temperature devices under 21 CFR regulations, Hydra Series III makes it that much easier to comply.
The Universal Input Connector plugs into any open slot in the 2638A that contains a relay card. The Universal Input Connector has 22 input channels (20 universal inputs and 2 dedicated, low-burden input current channels). Each input connector contains a CJC (cold junc­tion compensation) device, which is calibrated at the factory. The calibra­tion date and input connector serial number are programmed into the
input connector and are read by the 2638A when installed. This informa­tion is saved in the test setup data file, which is available for review with any associated scan data from a test setup. This feature is a valuable form of traceability if you are working in a regulated industry.
Wiring a test or system setup for 20 to 60 or more channels can be time consuming. With the inexpensive plug-in Universal Input Connector, you can wire your system once, quickly disconnect the connector from your Hydra, and then reconnect the Hydra to another input connector for use in a different area.
Other data loggers require you to wire your inputs directly to an expensive “plug-in” active component signal conditioning module. If you need your instrument at another loca­tion for another test, you must remove your wiring or use another expensive plug-in signal conditioning module. With Hydra Series III, all your signal conditioning is inside the mainframe, not in your input connector.
Using multiple low-cost Universal Input Connectors gives you the flex­ibility to leave your input connector at the test site, completely wired, and ready to use. When you need data from that site, simply “plug in” and load your saved setup file. It’s that simple!
Expandable channel capacity
Each 2638A has three slots in the rear panel. Each slot can hold a relay card and a 22-channel Universal Input Connector. Three models are available, from 22 channels to 66 channels per mainframe. Select a base model with 22 channels and add 22-channel expansion kits when needed. The low cost per channel makes a 2638A a good value for any budget.
5
5
Ordering information
2638A/60 Data Acquisition Unit/DMM: 60 universal
channels (includes 3 relay boards, 2638A-RLY and 3 2638A-100 connectors
2638A /40 Data Acquisition Unit/DMM: 40 universal
channels (includes 2 relay boards, 2638A-RLY and two 2638A-100 connectors
2638A/20
ata Acquisition Unit/DMM: 20 universal
D channels (includes one relay board, 2638A-RLY and one 2638A-100 connector
Power selection: Specify 100 V, 120V, 220 V, 240 V power when ordering (power setting may be changed by the end user)
Each 2638A is shipped with the relay boards and Universal Input Connectors installed, one DMM style test lead set, product manual, safety information and warranty registration on CD, power cord, screwdriver, a traceable calibration report with data, and 2680A-APSW/L Fluke DAQ Lite Software.
Options and accessories
2638A-20chkit 20-channel Expansion Kit for 2638A:
(includes one relay board 2638A-RLY and 2638A-100 connector)
2638A-100
Extra Universal Input Module for 2638A 2638A-RLY
xtra Relay Board for 2638A
E (Replacement)
Y2638
-inch Rackmount, Single/Dual
19 Mounting
2638A-101 10 ohm Shunt Resistors (quantity 10 each) 100 mA max, 0.08 %
2638A-1GB
B USB Flash memory drive
1 G
2638A/CASE
638A Transit Case
2
Accredited Calibration Certificate 17025: add option/C to model
Software
2680A-APSW/LU Upgrade from Lite version to full version of Fluke DAQ Software, 2680A-APSW
2680A-904 Trend Link for Fluke Data Acquisition
Products (requires 2680A-APSW)
On-board math channels
The 2638A has 20 on-board math channels with two alarms per channel to allow you to perform conversions and other calculations as your data is scanned. All channel results are stored in the data file for later analysis plus you have the ability to set alarms on the calcu­lated results of a math channel. Math functions available:
S
quare root
Polynomial (6th order)
Exponent
• Absolute value
R
eciprocal
Multiply/Divide
Add/Subtract
• Average (up to 10 channels)
• Minimum (up to 10 channels)
Maximum (up to 10 channels)
Log 10
Natural Log
Graphical color display with easy-to-use menus
Never get lost again in a complex menu tree while configuring chan­nels or setting up a test. The large, full color, thin film diode (TFD) display enables the Hydra SeriesIII to display comprehensive easy-to­understand data and easy menu navigation. Back-lighted function keys quickly confirm the active menu selection. The “Record” key illumi­nates to indicate when the 2638A is recording data in scan, monitor or DMM mode. You always have visible confirmation when your data is being recorded.
Copy-and-paste channel functions make repetitive channel setups a simple task. Top-of-screen menu bar headings always let you know where you are in the setup process.
View your data with the push of a button. Page through all channel data and alarms in a quick view mode or scroll through channels and channel statistics individually. Statistics include rate of change, min, max, standard deviation, average, sample size and peak-to-peak information.
Language support
All displayed text in the menus and data display area are translated to eight languages. You can change the language under the instrument setup area with the push of a button. French, Spanish, Japanese, German, Korean, English, Portuguese, Chinese and Russian are all supported languages in the 2638A.
DMM mode adds functionality and value
The Hydra Series III is based on a
6.5 digit (22-bit) precision digital multimeter measurement engine with exceptional measurement quality and resolution—so when you are not using your Hydra to collect multi-channel data, you can use it as a digital multimeter. Front-panel “DMM-style” input jacks and dedicated DMM menu selections enable you to measure dc voltage, dc resistance, ac voltage, ac resistance, ohms, frequency, and temperature (thermocouples, RTDs and thermistors). Record DMM measurements to a separate DMM data file for later viewing. The 2638A also displays measurement statistics and graphs measurements right on the main display.
6
2638A Hydra Series III specifications
General specifications
Mains voltage
100 V Setting: 90 V to 110 V 120 V Setting: 108 V to 132 V 220 V Setting: 198 V to 242 V 240 V Setting: 216 V to 264 V
Line frequency
47 Hz to 440 Hz
Power consumption
36 VA peak (24 W average)
Temperature
Operating: 0 °C to 50 °C Storage: -20 °C to 70 °C Warm-up: 1 hour to full accuracy specifications
Relative humidity (non-condensing)
Operating: 0 °C to 28 °C <90 %
28 °C to 40 °C <75 % 40 °C to 50 °C <45 %
Storage: -20 °C to 70 °C <95 %
Input protection
Front panel: 300 V CAT II Input module: 150 V CAT II, 250 V rms with maximum transient voltage of 1000 V peak.
Channel capacity
Universal channel: 61 (1 on front panel) Current channels: 2 per input module (1 on front panel) Digital I/O: 8 bits Totalizer: 1 Alarm outputs: 6 Trigger input: 1
Math channels
Number of channels: 20 Operations: Add, subtract, multiply, divide, average, polynomial, log, exponent, absolute value, minimum, maximum, reciprocal, square root
Trigger types: Interval, external (trigger input), alarm, remote (bus), manual
LAN: Ethernet 10/100, TCP/IP USB: (virtual serial port) full speed; rear port Type B USB: Front port; Type A
Memory
Scan data RAM: 1 Mb Data flash memory: 10 Mb Setup flash memory: 10 Mb
Scan rate
Fast: 46 channels per second max (dc) Medium: 17 channels per second Slow: 3 channels per second Display resolution: 4.5 to 6.5 digits, depending on function and sample rate
Trigger
Absolute voltage range: -4 V to 30 V Minimum logic high: 2.0 V Maximum logic low: 0.7 V Minimum pulse width: 100 μs Maximum latency: 100 ms
Alarm Output
Absolute voltage range: -4 V to 30 V Output type: Open drain active low Output logic low: 0 V to 0.7 V Maximum sink current: 100 mA
Digital I/O
Absolute voltage range: -4 V to 30 V Input minimum logic high: 2.0 V Input maximum logic low: 0.7 V
Totalizer
Minimum pulse width: 100 μs Maximum frequency: 10 kHz Debounce time: 5 ms Maximum count: 1048575
Hydra Series
Input Range Resolution Accuracy
DC volts 100 mV to 300 V 0.1 µV to 1 mV 0.0024 % DC current 100 µA to 100 mA 0.1 nA to 100 nA 0.015 % AC volts 100 mV to 300 V 0.1 µV to 1 mV 0.11 % AC current 100 µA to 100 mA 0.1 nA to 100 nA 0.3 % Resistance 100 Ω to 100 MΩ 0.1 m Ω to 100 Ω 0.01 % Frequency 20 Hz to 1 MHz 0.01 Hz to 1 KHz 0.01 % RTD (pt) -200 °C to 600 °C 0.001 °C 0.016 °C Thermistor -40 °C to 150 °C 0.001°C 0.007 °C
Thermocouple type
K -270 °C to 1372 °C 0.01 °C 0.15 °C 0.50 °C
T -270 °C to 400 °C 0.01 °C 0.11 °C 0.41 °C
R -50 °C to 1768 °C 0.01 °C 0.47°C 0.52 °C
S -50 °C to 1768 °C 0.01 °C 0.54 °C 0.60 °C
J -210 °C to 1200 °C 0.01 °C 0.12 °C 0.53 °C
N -270 °C to 1300 °C 0.01 °C 0.17 °C 0.44 °C
E -270 °C to 1000 °C 0.01 °C 0.09 °C 0.45 °C
B 100 °C to 1820 °C 0.01 °C 0.55 °C 0.55 °C
C 0 °C to 2315 °C 0.01 °C 0.33 °C 0.54 °C
D 0 °C to 2315 °C 0.01 °C 0.32 °C 0.44 °C
G 0 °C to 2315 °C 0.01 °C 0.32 °C 0.33 °C
L -200 °C to 900 °C 0.01 °C 0.12 °C 0.48 °C
M -50 °C to 1410 °C 0.01 °C 0.14 °C 0.41 °C
U -200 °C to 600 °C 0.01 °C 0.11 °C 0.40 °C
W 0 °C to 2315 °C 0.01 °C 0.32 °C 0.33 °C
Range Resolution Accuracy
(External) CJC
Accuracy (Internal) CJC
7
2680 Series
2686A Data Logging System
Key features
120 channel capacity chassis designed for small- and large­scale precision data acquisition applications.
User-scalability from 20 to 120 universal analog input channels, which can include
digital input/output and alarm contact outputs in a single chassis.
Universal input modules provide precision measurement of thermocouples, dc voltage, ac voltage, ohms, RTDs, thermis­tors, current, frequency. Connect any input type to any channel to match your application require­ments—no “wasted” channels.
S
uperior thermocouple
measurement accuracy
(J, K, R, S, T, N, L, U, C, B)
M
ultiple speed and scan
selections
Universal input conditioning for any input, on any channel, any time (V dc, V ac, ohms, frequency, RTD, thermocouple, thermistor or current).
Optional precision, high-isola-
tion analog universal input module (PAI) or fast scanning analog universal input module (FAI) to connect and measure
virtually any electrical or phys­ical parameter.
Computed channels, in addition to the 20 analog channels, each mainframe has 60 math channels that perform custom calculations using addition, subtraction, multi­plication, division, log, natural log, exponent, square root, absolute value, and integer func­tions. Math channels feature the same alarm capability as analog channels, which saves having to perform separate post calcula­tions on channel data. It is also especially useful for monitoring and alarming on real-time calcu­lated values such as power, flow, volumes, pressure, and more.
F
luke DAQ software which
controls all functions and data files, communicates with and controls Fluke 2680A Series, NetDAQ products and provides real-time and historical trending.
20 digital I/O and 8 form C,
1 A relay output module
for hard control of equipment.
Multiple power sources: 100 V to 240 V and 9 V dc to 45 V dc.
®
and Hydra Series III
Top precision and scalability for standalone or networked data acquisition
The Fluke 2680 Series data acqui­sition systems combine the best of lab precision with the rugged flexibility required in rapidly changing industrial applications. Whether you choose the 2680A Data Acquisition System with high-speed 10/100BaseT Ethernet network support or the 2686A Data Logging System, you can seamlessly expand your system any time, from 20 to more than 2,000 channels, just by adding modules and chassis.
Both models feature six slots in each chassis that you can fill with modules as needed to meet your application requirements. Five slots in each chassis are available for any combination of 2680 Series 20-channel analog input modules. The sixth slot is reserved for a 2680 Series digital I/O relay module to add control capabilities to your system. If you don’t need the sixth slot for control, you can plug in an additional analog input module, increasing your channel count to 120 in a single chassis.
You can also link multiple 120 channel systems together seamlessly for the widest possible view of your data. And with TCP/IP connectivity you can connect to existing LANs to distribute information wherever it needs to go. Whether you need speed and throughput, isolated precision, or digital I/O and relays, the Fluke 2680 Series can scale up to thousands of channels to meet your needs.
8
Fluke 2680 Series chassis and module selection chart
Chassis Analog
channels/ chassis
2680A 120 none Ethernet 20 DIO + 8 relay
2686A 120 ATA Flash to
Module Readings/
sec (max)
2680A-FAI 1000 20/universal analog 50/0.02 % 0.8 °C 2680A-PA I 100 20/universal analog 150/300/0.01% 0.4 °C 2680A-DIO N/A 20/digital; 8/relay 30 N /A
On board memory PC interface DIO/ch assis
DPST relays
1 GB
Channels/type Max voltage/
Ethernet 20 DIO + 8 relay
accuracy
DPST relays
Basic TC accuracy (type K)
Choose your chassis for standalone or networked data acquisition
The Fluke 2680 Series offers the choice of networked data acquisi­tion, stand-alone data logging, or a combination of both. Choose from two basic chassis models—the 2680A Data Acquisition System or the 2686A Data Logging System and then add the modules as needed to meet your requirements.
2680A Data Acquisition System chassis
The Fluke 2680A Data Acquisition System is the choice for multichannel applications requiring reliable Ethernet communications. It features a front-end style data acquisition system that communicates and distributes data anywhere you need it to go. The 10/100 LAN communica­tions interface makes it compatible with both older and newer network platforms.
2686A Data Logging System chassis
The Fluke 2686A Data Logging System writes data to a memory card for easy retrieval and storage, making it ideal for remote locations and mobile or non-computer assisted data logging applications. The system comes with a 1 GB flash memory card, and supports memory cards of up to 4 GB to log data in standalone mode for easy storage and retrieval. The 2686A is easily configured for stand-alone data logging operations by simply selecting a preset configu­ration from the memory card. It can also be used in networks in tandem with the 2680A to provide the extra data security of a memory card.
Choose your modules
You can equip each 2680 Series chassis with up to six modules of the same type or combine fast analog input (2680A-FAI) and precision analog input modules (2680A-PAI) along with a digital I/O (2680A-DIO) and relay module. Both the 2680A­FAI and the 268A0-PAI modules support a wide range of inputs including dc volts, ac volts, RTD, Ohms, thermocouple, thermistor, dc current, ac current, and frequency. Other sensors and transducers, such as load cells, pressure sensors, and displacement sensors can be easily incorporated into your measurement system. Buy just the modules you need in the combinations you need them and expand your system as your requirements grow.
2680A-FAI: The speed to capture dynamic process changes
The Fluke 2680A-FAI module is a perfect choice when you need a lot of information in a hurry and still need to maintain a high degree of accuracy for your measurements. The 2680A-FAI module provides chassis throughput rates of more than 3,000 channels-per-second. Specially manufactured field effect transistors (FETs) allow up to + 50 V input, well above the 15 V industry norm, and channel-to-channel isolation to give you more confidence in the integrity of your measurements.
2680A-PAI provides high preci­sion and high isolation for the most demanding jobs
The Fluke 2680A-PAI 20-channel high precision, high isolation module serves the most demanding jobs where precision and isolation are critical. Some of the most notable applications for this module include temperature measurement in semi­conductor and pharmaceutical manufacturing, as well as nuclear plant performance monitoring. The 2680A-PAI module offers 300 V of isolation on two channels and 150V on 18 channels, as well as 18 bit resolution and excellent thermo­couple accuracy, all in a scalable system.
2680A-DIO: Digital I/O and relay outputs add control
For data acquisition systems that also require control functionality, the Fluke 2680A-DIO digital I/O and relay output module provides 20 digital I/O and eight hard-contact 1 A relays to provide the security and control you need. This equips each chassis to respond to a wide range of alarm or control situations. The 2680A-DIO also includes an up/ down counter with preset count capability, so you don’t need to begin all counts at zero.
9
Model 2680A-PAI Module
Input Range Resolution Accuracy (3-Sigma)
DC Volts 90 mV to 150/300 V 0.3 mV to 1 mV 0. 01 %
2
AC Volts
300 mV to 150/300 V 10 mV to 100 mV 0.3 % Resistance 300 Ω to 3 MΩ 1 mΩ to 10 Ω 0 .015 % Frequency 15 Hz to 1 MHz 0.01 Hz to 100 Hz 0.05 % RT D ( Pt100) -200 °C to 600 °C 0.003 °C 0.06 °C
Thermocouples
J -100 °C to 760 °C 0.02 °C 0.35 °C K -100 °C to 1372 °C 0.02 °C 0.4 °C T -100 °C to 400 °C 0.02 °C 0.3 °C
Other Thermocouple types R, S, B, C, E, N, L, U
Model 2680A-FAI Module
Input Range Resolution Accuracy (3-Sigma)
DC Volts 90 mV to 50 V 3 mV to 10 mV 0.02 %
2
AC Volts Resistance 300 Ω to 3 MΩ 10 mΩ to 100 Ω 0.02 % Frequency 15 Hz to 1 MHz 0.01 Hz to 100 Hz 0.05 % RT D ( Pt100) -200 to 600 °C 0.03 °C 0.16 °C
Thermocouples
J -100 °C to 760 °C 0.2 °C 0.7 °C K -100 °C to 1372 °C 0.2 °C 0.8 °C T -100 °C to 400 °C 0.2 °C 0.7 °C
Other Thermocouple types R, S, B, C, E, N, L, U
1
Total instrument accuracy for 90 days following calibration and ambient temperature range of 18 to
28 °C. Includes A/D errors, linearization conformity, initial calibration error, isothermality errors, refer­ence junction conformity and power line voltage effects within the range from 107 V ac to 264 V ac.
2
Accuracies for crest factor to 2.0.
300 mV to 30 V 10 mV to 1 mV 0.3 %
1
1
2686A active channels and memory card capacity (scans)
Memory usage/ Active channels
128 M B 800,000 528,000 400,000 320,000 264,000 224,000 256 MB 1.6 M 1.056M 800,000 640,000 528,000 448,000 512 MB 3.2 M 2 .112 M 1.6 M 1.28 M 1.056 M 896,000 1 GB 6.2 M 4.224 M 3.2 M 2.56 M 2 .112 M 1.792 M
Estimating space: 80 bytes/scan + 4 bytes/channel scanned. (Allow 4.5 % overhead for card formatting)
20 ch 40 ch 60 ch 80 ch 100 ch 120 ch
10
2680 Series DIO Module and Universal Input Module
2680 Series specifications
Universal input module: Connect 20 analog inputs or virtually any sensor type without external signal conditioning
2680A Series interfacing: Ethernet; uses TCP/IP protocol via RJ45 connector, Cat 5. RS-232 input for calibration.
• External trigger: Activate scanning with real-world events
Totalizer: Pre-settable starting count up/down counter
• Alarm outputs: Flag out-of-limit conditions to external devices
Power: Accepts 100 V ac to 240 V ac, or 9 V dc to 45 V dc. Can
operate from both simultaneously for fail-safe power operation
Channel capacity (2680A or 2686A)
20 to 120 channels per chassis (6 analog input modules of 20 channels each) One master alarm (open collector) per chassis Communications: 10BaseT/100 BaseT, TCP/IP via RJ45 connector, CAT V
Math functions
In addition to its analog and digital input channels, each system supports 60 computed channels. Calculations include time and rate, addition, subtraction, multiplication, division, log, natural log, exponent, square root, absolute value, integer function and average.
Measurement speed (2680A-PAI)
Slow: 6 readings/second nominal Medium: 41 (50 Hz), 48 (60 Hz) read­ings/second nominal Fast: 143 readings/second nominal (5 readings/second for V ac nominal, 140 readings/ second on 300 Ω range, 37 readings/second on 3 MΩ range)
Measurement speed (2680A-FAI)
Slow: 45 (50 Hz), 54 (60 Hz) read­ings/second nominal Medium: 200 readings/second nominal Fast: 1000 readings/second nominal (5 readings/second for V ac nominal, 370 readings/ second on 300 Ω range, 44 readings/second on 3 MΩ range)
Analog to digital converter
2680A-PAI: 18 bit, multi-slope type 2680A-FAI: 16 bit, multi-slope type
Common mode rejection
2680A-PAI:
2680A-PAI: AC: ≥120 dB (50/60 Hz, ± 0.1 % max 1 kΩ source imbalance) DC: ≥120 dB
2680A-FAI:
2680A-FAI: AC: ≥100 dB (50/60 Hz, ±0.1 % max 1 kΩ source imbalance) DC: ≥100 dB
Normal mode rejection
50 dB @ 50/60 Hz, ± 0.1 %
Common mode voltage maximum
2680A-PAI: 300 V dc or V ac rms (channels 1,11); 150 V dc or V ac rms (all other channels) 2680A-FAI: 50 V dc or 30 V ac rms (all channels)
2680A-DIO
Totalizing input
Pre-settable starting count up/down counter DC coupled, non-isolated, max +30 V, min -4 V Max count: 4,294,967,295 Minimum signal: 2 V peak Threshold: 1.4 V Rate: 0 kHz to 5 kHz (debounce off) Hysteresis: 500 mV Input debouncing: None or 1.66 ms
Digital inputs/outputs: 20
Threshold: 1.4 V Hysteresis: 500 mV Maximum input: +30 V, min -4 V; non-isolated Logical “zero” output:
0.8 V max |out = -1.0 mA (1 LSTTL load equivalent) 1.8 V max |out =
-20 mA 3.25 V max |out = -50 mA Logical “one” output: Output voltage depends on external load 3.8 V min|out = 0.05 mA (1 LSTTL load equivalent)
Relays
Quantity: 8 Type: Form C; DPST Current: 1 amp, non-inductive Operation time: 75 ms
Alarm associations
Each Digital I/O may be randomly assigned as a digital input, status output, or alarm output (associated with any input channel or channels)
Trigger input
Minimum pulse: 5 µs Minimum latency: 100 ms Input “High”: 2.0 V min,
7.0 V max Input “Low”: -0.6 V min, 0.8 V max non-isolated, contact closure and TTL compatible
Clock
Accurate to within 1 minute/month for 0 °C to 50 °C range
11
Ordering information
Hardware
2680A Data Acquisition System Chassis, 6 slots 2686A Data Logging System Chassis, 6 slots, with
ATA Flash memory drive, includes 1 GB ATA flash memory card
2680A-FAI
Fast Analog Input Module 20 universal channels, 50 V max isolation. 1000 ch/sec scan rate, 16 bit resolution
2680A-PAI
Precision Analog Input Module 20 Universal Channels, 300 V max isolation, 18 bit resolution 140 ch/sec scan rate
2680A-DIO
Digital I/O and Relay Module, 20 DIO, 8, 1 A Contacts, Totalizer (one per chassis max)
2680 Series Chassis
General specifications
Software
2680A-APSW
Fluke DAQ Configuration Software and extra license for 2680 Series (included with 2680A and 2686A)—Full Version
2680A-904
Trend Link for Fluke
Accessories
2680A-180 Universal Input Module, Extra Connector 2680A-102 2680A-DIO Connector Module, Extra
Connector 2620A-101 Shunt resistor set (12 ea), 10 W, 0.1 %
2680A-810
1 GB ATA Flash Memory Card for 2686A
Y2680
19-inch Rack Mount Kit for 2680 Series
Power
100 V ac to 240 V ac, 50 Hz or 60Hz 100 VA max, or 9 V dc to 45 V dc (50 W max—all slots filled + memory card installed) (if both sources are applied simultaneously, the greater of ac or dc is used.), at 120 V ac the equivalent dc voltage ~14.5 V
Temperature, humidity (non-condensing)
Operating:
-20 °C to 28 °C, ≤90 % RH; 28 °C to 40 °C, ≤75 % RH; 40 °C to 60 °C, ≤50 % RH Storage:
-40 °C to 70 °C, 5
% to 95 % R
H
Altitude
Operating: 2000 m Storage: 12,200 m
Standards
All inputs: IEC Measurement Category II Product conforms to the following safety and emission standards: EN610000-4-2,3,4,6,8 EN61326 EN61010-1, CAT II CAN/CSA C22.2 No. 61010-1:2004
Size
473 mm x 423 mm x 237 mm (18.6 in x 17 in x 9.3 in)
Weight
2680A/2686A chassis only:
8.47 kg (18.86 lbs.) 2680A-FAI: 0.79 kg (1.74 lbs.) 2680A-PAI: 1.21 kg (2.66 lbs.) 2680A-DIO: 0.80 kg (1.75 lbs.)
Interfaces
Ethernet: Conforms to IEEE 802.3 Ethernet standard, compatible with 100 BaseT and 10 BaseT standards, uses TCP/IP protocol RS-232C: For calibration only
System Requirements
Processor 32/64 bit, 1 GHz
Microsoft Windows
8 GB RAM
3 GB free hard disk space
VGA or SVGA display, 100 %
IBM compatible with 2 MB Video RAM (VRAM)
CD-ROM drive
®
Vi sta /7/8
12
Operating temperature
-20 °C to 60 °C (-4 °F to +140 °F)
Storage temperature
-40 °C to 70 °C (-40 °F to +158 °F)
NetDAQ® Series
Fluke NetDAQ
NetDAQ® is designed to fit into your system
The versatile NetDAQ system offers flexible options for data distribution.
Configure a dedicated system. Simply connect your NetDAQ unit to your desktop or notebook PC for quick, easy data collection.
Add NetDAQ high-speed network. Adding
NetDAQ units directly to your existing network saves the time and expense of setting up large dedicated networks and enables you to implement distributed applications with NetDAQ units in multiple locations enabling multiple PC users to monitor data in real time as it is collected.
A
system to your company network. Isolate your data acqui-
sition application from the rest of the network while still allowing multiple-user viewing. This prevents your data acquisition application from being hampered by network operations and protects it from network failure.
Q
The NetDAQ system supports 3,000 rps from multiple instru­ments ensuring high throughput for all units. Plus on-board memory provides a data buffer in case network traffic prevents timely delivery of time-stamped data to the host PC.
®
®
units to your
dd a dedicated NetDAQ
®
uick results you can rely on.
Computed channels save time. In addition to its 20 analog input channels, each NetDAQ unit supports 10 computed channels. The computed channels perform custom calculations using addi­tion, subtraction, multiplication, division, log, natural log, expo­nent, square root, absolute value, and integer functions. Math chan­nels feature the same alarm capa­bility as analog channels which saves having to perform separate post calculations on channel data. It is also especially useful for monitoring and alarming on real-time calculated values such as power, flow, volumes, pressure, and more.
ount more than four billion
C “on/off” events. Both NetDAQ
models include a totalizer input channel which is continuously sampled and recorded.
Key NetDAQ® features
Expandable systems from 20 to 2000 analog channels
High accuracy readings, up to
0.01 %
High throughput, to support up to 1,000 ch/sec
Distributed design enables multiple users to view data remotely with standard browsers
eplaces chart recorders
R
13
A system of up to 2000 channels can be configured by connecting multiple NetDAQ units to one PC
NetDAQ® 2640A
The Fluke NetDAQ 2640A delivers extremely high accuracy and resolution to provide calibration­level performance:
Measures up to 300 V at up to 100 r ps
Offers 0.01 % V dc—0.3 °C TC accuracy
Scans from 6 to 100 channels per second
NetDAQ® 2645A
The NetDAQ 2645A delivers higher speed data acquisition making it ideal for applications that require more dynamic signal capture.
Directly measures multiple inputs of up to 50 V at 1,000 rps
Delivers 0.01 % V dc - 0.3 ºC TC accuracy
cans 48 to 1,000 channels per
S second
Fluke NetDAQ® rear panel (Universal Input Module removed)
Choose the NetDAQ Model that matches your requirements
Model Reading/sec
(Max)
2640A 100 0.3 mV 15 0/30 0 0.5 °C 2645A 1,000 3.0 mV 50 0.7 °C
Distributed data acquisition where and
when you need it
A Fluke NetDAQ networked data acquisition system is a powerful combination of hardware and FlukeDAQ software (2680A-APSW) that seamlessly delivers data directly over your network. These systems, along with optional Trend Link soft­ware, enable multiple users to view just the information they need in real time, from anywhere on the system. View current, temperature, voltage, and more on the same screen at the same time. You can also monitor several units simultaneously making it ideal for small-to-medium sized equipment monitoring, product testing, and process validation appli­cations. A NetDAQ unit can also be used as a portable dedicated system connected to a notebook computer for maintenance, product valida­tion, research, and troubleshooting applications.
Resolution (Volts dc)
Max. Input (Volts dc)
Basic TC Accuracy (Type T)
Combine from one to twenty NetDAQs into an integrated system of up to 2000 channels within FlukeDAQ software. Two NetDAQ models offer a choice of scan speeds of 100 channels/second or 1,000 channels/second, and accuracy (up to 0.01 %) to meet your needs. And both NetDAQ models use Fluke’s patented Universal Input Module which accepts any combination of analog input types for each of its 20 channels—without requiring external signal conditioning.
With all these capabilities NetDAQ addresses the escalating need for measurement, recording, and anal­ysis tools that enable you to improve quality, maximize process efficiency and meet regulatory requirements.
14
NetDAQ specifications
Universal input module: Connect 20 analog inputs of virtually any sensor type without external signal conditioning
NetDAQ interfacing: Ethernet network cabling. RS-232 input for calibra­tion
• External trigger: Activate scanning with real-world events
Totalizer: Count on/off events, value reported with every scan
Alarm outputs: Flag out-of-limit conditions to external devices
Power: Accepts 107 to 264 V ac,or 9 to 16 V dc. Can operate from both
simultaneously for fail-safe power operation
NetDAQ® 2640A/2645A
Channel capacity
Analog inputs: 20
Measurement rate (2640A)
Slow: 6 Rdgs/s nominal Medium: 41 (50 Hz), 48 (60 Hz) Rdgs/s nominal Fast: 100 Rdgs/s nominal (5 Rdgs/s for V ac nominal, 140 Rdgs/s on 300 Ω range, 37 Rdgs/s on 3 MΩ range)
Measurement rate (2645A)
Slow: 45 (50 Hz), 54 (60 Hz) Rdgs/s nominal Medium: 200 Rdgs/s nominal Fast: 1000 Rdgs/s nominal (5 Rdgs/s for V ac nominal, 370 Rdgs/s on 300Ω range, 44 Rdgs/s on 3 MΩ range
Analog to digital converter
2640A: Multi-slope type, linear to 18 bits 2645A: Multi-slope type, linear to 16 bits
Common mode rejection
2640A: AC: ≥120 dB (50/60 Hz, ±10.1 % max 1 kΩ source imbal­ance); DC: ≥120 dB 2645A: AC: ≥100 dB (50/60 Hz, ±10.1 % max 1 kΩ source imbal­ance); DC: ≥100 dB
Normal mode rejection
50 dB @ 50/60 Hz, ±10.1 % Common mode and normal mode voltage maximum 2640A: 300 V dc or V ac rms (chan­nels 1,11); 150 V dc or V ac rms (all other channels) 2645A: 50 V dc or 30 V ac rms (all channels)
Model 2640A NetDAQ
Input Range Resolution Accuracy (3-Sigma)
DC Volts 90 mV to 150/300 V 0.3 µV to 1 mV 0. 01 % AC Volts Resistance 300 Ω to 3 MΩ 1 mΩ to 10 Ω 0.015 % Frequency 15 Hz to 1 MHz 0.01 Hz to 100 Hz 0.05 % RT D ( Pt100) -200 to 600ºC 0.003 ºC 0.06 ºC
Thermocouples
J -100 ºC to 760 ºC 0.02 ºC 0.35 ºC K -100 ºC to 1372 ºC 0.02 ºC 0.4 ºC T -100 ºC to 400 ºC 0.02 ºC 0.3 ºC
Other Thermocouple types R, S, B, C, E, N
2
300 mV to 150/300 V 10 µV to 10 mV 0 .3 %
Model 2645A NetDAQ
Input Range Resolution Accuracy (3-Sigma)
DC Volts 90 mV to 50 V 3 µV to 10 mV 0.02 %
2
AC Volts Resistance 300 Ω to 3 MΩ 10 mΩ to 100 Ω 0.02 % Frequency 15 Hz to 1 MHz 0.01 Hz to 100 Hz 0.05 % RT D ( Pt100) -200 ºC to 600 ºC 0.03 ºC 0.16 ºC
Thermocouples
J -100 ºC to 760 ºC 0.2 ºC 0.7 ºC K -100 ºC to 1372 ºC 0.2 ºC 0.8 ºC T -100 ºC to 400 ºC 0.2 ºC 0.7 ºC
Other Thermocouple types R, S, B, C, E, N
Detailed specifications are available on request.
1
Total instrument accuracy for 90 days following calibration and ambient temperature range of 18 to 28 °C. Includes A/D
errors, linearization conformity, initial calibration error, isothermality errors, reference junction conformity and power line voltage effects within the range from 107 V ac to 264 V ac.
2
Accuracies for crest factor to 2.0.
300 mV to 30 V 10 µV to 1 mV 0. 3 %
Isolation
2640A: Analog input to analog input, and analog input to any digital input; meets IEC measurement category II, ANSI/ISA 61010-1 (82.02.01) :2004,
®
®
Current measurements
AC or dc current measurements up to 100 mA may be accomplished using the 2620A-101 10 Ω Current Shunt
Strip CAN/CSA C22.2 No. 61010-1:2004 for 150/300 V reinforced 2645A: Analog input to any digital input; meets IEC measurement cate­gory II, ANSI/ISA 61010-1 (82.02.01) :2004, CAN/CSA C22.2 No. 61010­1:2004 for 150/300 V reinforced
Totalizing input
DC coupled, non-isolated, max +30
V, min -4 V
Max count: 4,294,967,295
Minimum signal: 2 V peak
Threshold: 1.4 V
Rate: 0-5 kHz (debounce off)
Hysteresis: 500 mV
Input debouncing: None or 1.66 ms
1
1
15
Ordering information
2640A NetDAQ Data Acquisition Unit (100 rps) 2645A NetDAQ Data Acquisition Unit (1,000 rps) Includes: Instrument, FlukeDAQ Software,
Universal Input Module, manual on CD, power cable.
Application software
2600A-904 Trend Link for Fluke
2680A-APSW
Fluke DAQ Software and extra license (one license included with 2680 Series, 2640A, 2645A)
Options and accessories
2620A-100 Extra Universal Input Module
2620A-101 Current Shunts, 10 Ω, for 0 to 100 mA, Qty (12)
Y2641 19 in Rack Mount Kit, Single/Dual
Digital inputs
Threshold: 1.4 V Hysteresis: 500 mV Maximum input: +30 V, min -4 V; non-isolated
Digital/master alarm outputs
The open collector output lines are non-isolated, TTL compatible
Digital I/O and alarm outputs
8 total; totalizer: 1
Alarm associations
Digital I/O may be used as a digital input or alarm status output (asso­ciated with any input channel or channels)
Trigger input
Minimum pulse: 5 μs Minimum latency: 2 ms Repeatability: 1 ms Input “High”: 2.0 V min, 7.0 V max Input “Low”: -0.6 V min, 0.8 V max non-isolated, contact closure and TTL compatible
Clock
Accurate to within 1 minute/month for 0 °C to 50 °C range
Power
107 V ac to 264 V ac, 50 Hz or 60 (<15 watts), or 9 to 16 V dc (<6 watts). (If both sources are applied simultaneously, the greater of ac or dc is used.) At 120 V ac the equivalent dc voltage ~14.5 V.
Temperature, humidity (non-condensing)
Operating:
-20 °C to 28 °C, ≤90 % RH 28 °C to 40 °C, ≤75 % RH 40 °C to 60 °C, ≤50 % RH Storage: -40 °C to 70 °C, 5 to 95 % RH
Altitude
Operating: 2000 m (6,500 ft) Storage: 12,200 m (40,000 ft)
Electromagnetic Interference (EMI)
Passes FCC EMI Class B Equipment, Vfg. 243, European Norms EN50081-1 and EN50082-1, CE approved
Safety
Complies with applicable sections of CE, IEC/EN 61010-1:2001, ANSI/ ISA-61010-1 (82.02.01) :2004, CAN/ CSA C22.2 No. 61010-1:2004, and CSA standards as noted under “Isolation”
Weight
3.7 kg (8.2 lbs)
Dimensions (HxWxD)
9.3 cm x 21.6 cm x 39.4 cm (3.67 in x 8.50 in x 15.50 in)
Battery life
10 years minimum for real-time clock
Interfaces
Ethernet: Conforms to IEEE 802.3 Ethernet standard. Compatible with 10Base-T standards. Uses TCP/IP protocol. RS-232C: For calibration only. The optional NetDAQ Service Manual provides step-by-step cali­bration instructions.
Data buffer memory
Each scan consists of computed channels, time stamp, all defined analog input channels, the status of the eight digital I/O, and the totalizer count. The number of stored scans varies with the number of channels configured ranging from 6400 scans for 1 configured channel to 1,896 scans for 20 configured channels.
Fluke data acquisition systems are supported by a wide variety of optional software and development tools to support almost any research or industrial application.
16
Fluke DAQ Software
The Fluke DAQ application is praised by users for its versatile handling of data acquisition and logging. Improved trending, file handling, web interface, web control, and convenient print functions for charts make this version of Fluke DAQ a feature-rich program. Fluke DAQ 6.0 is truly a program you can trust with your important data and analysis needs.
Fluke DAQ comes in two basic versions, Full and Lite, to accommo­date your data collection needs and best match program features to your instrument usage.
2686A-APSW (Full)
One full version license is included with the purchase of the 2640A, 2645A or 2680A Series mainframe. This version has all the features you might expect from a distributed Ethernet-based instrument system including remote web viewing, OPC connectivity, exporting of historical chart data and other premium system type features.
2680A-APSW/L (Lite)
The Lite version is included with each 2638A Data Acquisition Unit and 1586A Precision Temperature Scanner. The Lite version realizes the need for simple data collection and a file creation program typical of the usage model of smaller stand­alone data logging systems, as well as the advanced user interface of these models, which minimizes the need for an extensive computer inter­face. Single instrument operation, configuration and data file creation are the focuses of this Lite version for quick and easy .CSV file creation and retrieval. If you find you need more advanced features for a larger system at a later date, upgrades are easily available to a Full version.
Fluke DAQ 6.0 key features (Full version)
Easy multi-unit configuration for any mix of 2638A Hydra Series III, 1586A Super-DAQ, NetDAQ or 2680 Series models
Full screen trend charting of up to 32 channels with zoom, print and scaling functions
Built-in OPC server software for sharing Fluke DAQ data with popular client programs
Advanced trend display and viewing tools with print functions
ogon security features
L
• Auto start on power interrupt settings
• Primary/secondary configurations available
Alarm logging history with acknowledgement features
• Four web clients for remote viewing and control of systems using secure
login
Automated email of alarm alerts
Over 2000-channel capability
17
Version feature comparison
Features 2680A-APSW
Multi-instrument configuration and operation
Configuration and CSV data file creation
Trend chart and number of viewable trends
Web connect thin client 4 instances
OPC and DDE OPC, DDE DDE
Automated email alerts
Alarm page view
History chart export
One license included with the following mainframe products
Trend Link Interface
System requirements
Operating system (32 or 64 bit)
Microsoft Windows Vista Service Pack 2
Microsoft Windows 7 Service Pack 1
Microsoft Windows 8 (excluding RT)
Microsoft Windows Server 2003 Service Pack 2
Microsoft Windows Server 2008 Service Pack 2
Microsoft Windows Server 2008 R2 Service Pack 1
Microsoft Windows Server 2012
Memory available: 8 GB Processor: 1 GHz or higher Available disk space: 3 GB or larger recommended Application file size: 429 MB
(Full)
Unlimited instruments (to 2000 channels)
32 trends 4 trends
2640A 2645A 2680A 2686A
Trend chart. View up to 32 trends on one graph, with the ability to save and load historical charts and add new chart formats. Chart controls for auto scale, fixed scale, horizontal and vertical zoom and grid division control.
Chart data export. Fluke DAQ makes it easy to extract data from any portion of your historical chart data. Simply select the data you want and export chart data to a convenient CSV file format.
Print capability. Print trend charts and alarm status information from a local PC or from the Fluke DAQ web view.
Web view. In addition to current readings, the web view feature allows users to display trend charts and the alarm screen in a web browser. Four web clients
The versatile and powerful 2680A-APSW
Easy instrument setup. Simply connect your 2638A, 1586A, NetDAQ or 2680A Series to your computer and your current hardware configu­ration will pre-populate in the configuration setup area, ready to edit if needed. The simple copy­and-paste feature makes quick work of setting up multiple channels with similar inputs.
allow password secure connec­tions from up to four remote users simultaneously.
Web control. Instrument scanning can be started and stopped remotely from the Web view screen in a browser, using one of the four thin web clients within Fluke DAQ.
Alarm pages. The Fluke DAQ alarm page gives the operator a full page view of historical and present alarm conditions. The operator has full control over alarm acknowledge­ment function and can select filters for viewing specific channel alarm history by channel or date range. Alarm conditions may also be emailed to users for immediate noti­fication of system status.
2680A-APSW/L (Lite)
One instrument per configuration
2638A 1586A
Off-line operation. Instruments can be left scanning when the Fluke DAQ 6.0 application shuts down. Start the program again and Fluke DAQ 6.0 software reconnects to your instruments and resumes data retrieval and control.
Import/export configuration files. The Fluke DAQ 6.0 software config­uration is saved in XML format, which allows the configuration to be easily imported, exported and edited.
Automatic start scan. Fluke DAQ
6.0 can be easily set to start scan­ning automatically when your computer is started. This allows unattended operation or automatic scan resuming after a power failure.
Multiple language support. Version
6.0 speaks your language and can be switched from one language to another during operation. Languages supported in Fluke DAQ include English, Spanish, Swedish, Russian, Korean, Japanese, Italian, German, French and Chinese.
Ordering information
2680A-APSW v6.0
Fluke DAQ 6.0 Application Software for Fluke data acquisition products
(included with 2640A, 2645A, 2680A and 2686A)
2680A-APSW/L
Fluke DAQ 6.0 Lite-Basic Data Collection Software (included with 2638A and 1586A)
2680A-APSW/LU
Upgrade from Lite to Full Version V6.0
2680A-APSW/U
Upgrade from 2680A-APSW Version 3, 4 or 5 to Full version 6.0
18
Trend Link for Fluke software
Gain advanced trending capabilities
Optional Trend Link for Fluke soft­ware is used in conjunction with FlukeDAQ application software. Trend Link makes it easy to:
Review real-time data in the context of historical data for performance comparisons
Automatically view statistics on any channel and compare multiple channels from different time periods
Zoom in on a particular time span for closer analysis
V
iew multiple windows—each
featuring different process param­eters—in real time
Calculate basic statistics such as mean and standard deviation for any trend
C
reate X-bar R charts and X-Y scatter diagrams for statistical analysis
Import data directly into spread­sheet programs from trend plots
Quickly find specific data
With Trend Link you can quickly scroll through volumes of historical and real-time data looking for key events or changes in the process. The dead-banding feature lets you limit recording to only those readings outside of the range of your normal process limits, saving you valuable disk space. Trend Link time stamps data with millisecond resolution so you can find just the data you’re looking for. Then you can compare multiple traces on the same screen or zoom in on a particular point in time.
Document your results
Cut and paste the data and trend plots you generate with Trend Link software into spreadsheet and word processing programs to generate presentation-quality reports. Or print plots directly for hard copy documentation.
19
Fluke measurement specification philosophy
The accuracy specifications for the Fluke 2680 Series, 2638A Hydra Series III, and NetDAQ Series instru­ments are calculated conservatively so that they include three standard deviations from the nominal value— this is referred to as 3-Sigma. More than 99.7 % of the instruments produced will perform within the error limits. Rigorous screening and testing procedures catch and correct the three out of 1,000 instruments which could have fallen outside their published specifications.
Many other products use a “root­sum-square” scheme, or only specify the error band within one standard deviation (1-Sigma) of nominal. This method produces a specification that appears to be more accurate, but the resulting “typical” specifications correctly characterize only ~66 % of the instruments produced. This method is kind of like knowing how accurate “most of the instruments” will be. The 3-Sigma specifications for the 2680 Series, Hydra, and NetDAQ tell you how accurate ALL of the instruments will be. Note: Listed specifications are summary in nature. Accuracies listed are most favorable within the stated range. You may obtain detailed specifica­tions at www.flukecal.com
For complete product specifica­tions or information on other Fluke products, contact your local Fluke sales representative.
Customer support
Choosing a data acquisition system that meets your specifications is only the first step in making a smart equipment investment. You also need to choose a company that can help you get up and running quickly and easily and that will support you throughout the life of the system. Fluke has addressed these issues by assembling a wide variety of services that are solidly backed by our sales and applica­tion support teams, world-wide service centers, and state-of-the art parts supply system. Our offerings range from comprehensive service programs and technical training to custom programming and system consulting.
Service CarePlans
Fluke offers various service plans to suit you individual needs. SilverCarePlans are warranty exten­sions that add years onto your new product warranty. Gold CarePlans provide extended warranty coverage and annual calibration for your product and covers return freight. CarePlans are available for all Fluke Data Acquisition products as well as most other Fluke products To learn more go to www.flukecal. com/support/service-plans. Locations to cover necessary repairs and performance testing, including parts, labor, and return surface freight costs. Warranty extensions may not be available in all coun­tries. Contact your local Fluke sales office for specific details.
Fluke. Keeping your world up and running.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176