Fluke Calibration 5322A-LOAD Instructions Manual

Й
5322A-LOAD
High Voltage Load Adapter
Instructions
Introduction
The 5322A-LOAD High Voltage Load Adapter (the Product) loads a hipot tester to create leakage current during hipot tester calibration with the 5322A Multifunction Electrical Tester Calibrator (hereafter the Calibrator). As shown in Figure 1, the Product consists of nine power-rated resistors configured to provide nine resistance taps from 10 kΩ to 10 MΩ. Each of the nine resistors in the Product can be put in parallel with any other resistor. To do this, use the supplied high­voltage jumper leads to short the resistor's red terminal to the resistor’s corresponding black terminal.The Product withstands a maximum voltage of 1.2 kV to
5.5 kV, depending upon the selected resistor.
10k 25k 50k 100k 250k 500k 1M 5M 10M
HI
Output
LO
Ieu004.eps
Figure 1. Load Schematic
XW Warning
To avoid possible electric shock or personal injury, use this Product only as specified in this Instruction Sheet or the
5322A Operators Manual.
How to Contact Fluke Calibration
To contact Fluke Calibration, call one of the following telephone numbers:
Technical Support USA: 1-877-355-3225
Calibration/Repair USA: 1-877-355-3225
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31-40-2675-200
Japan: +81-3-6714-3114
Singapore: +65-6799-5566
China: +86-400-810-3435
Brazil: +55-11-3759-7600
Anywhere in the world: +1-425-446-6110
To see product information and download the latest manual supplements, visit Fluke Calibration’s website at www.flukecal.com.
To register your product, visit
http://flukecal.com/register-product
.
PN 5006848 July 2018
©2018 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. Specifications are subject to change without notice.
Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A.
Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands
ООО «Флюк СИА 125167, г. Москва,
Ленинградский проспект дом 37, корпус 9, подъезд 4, 1 этаж
ЭС»
1
5322A-LOAD
Instructions
Symbols
The symbols used in these instructions and on the Product are shown in Table
Table 1. Symbols
Symbol Description
X
W
)
P
WARNING. HAZARDOUS VOLTAGE. Risk of electric shock.
WARNING.RISK OF DANGER. Risk of electric shock.
Consult user documentation.
Certified by CSA Group to North American safety standards.
Conforms to European Union directives.
Conforms to relevant Australian Safety and EMC standards.
1.
AC (Alternating Current)
. Protective conductor terminal
Earth
Fuse
~
Conforms to relevant South Korean EMC Standards.
This product complies with the WEEE Directive marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as category 9 "Monitoring and Control Instrumentation" product. Do not dispose of this product as unsorted municipal waste.
Preparing for Operation
The Product (see Figure 2) comes with a power line adapter (to run the cooling fans), a ground cable, three shorting cables, and these instructions.
The power line adapter comes with five mains plug adapters that are compatible with different power plug configurations.
Prior to use:
1. Select the appropriate plug adapter that matches the local power mains outlet.
2. Attach the plug to the power line adapter. The power line adapter is now ready for use with the Product.
3. Once you place the Product on top of the Calibrator, connect the grounding cable between the Product’s rear-panel ground terminal and the rear-panel ground terminal of the Calibrator. See the grounding cable connection in Figure 3 where the rear of the Product is shown.
XW Warning
To prevent possible electrical shock, fire, or personal injury:
Make sure that the ground terminal on the rear of the Product is connected to the ground (GND) terminal on the rear of the Calibrator. Any application with non-grounded housing is strictly prohibited.
Use only the shrouded high-voltage banana plug jumpers that are supplied with this Product to connect resistor values. Connect the black terminal first and disconnect the black terminal last when you connect resistors.
2
High Voltage Load Adapter
Preparing for Operation
W Caution
To prevent damage to the Product, make sure that the vents on the bottom of the Product and the fan exhaust vents are clear of obstructions for proper cooling.
Connect one end of the power line adapter to the mating power input connector socket on the rear panel of the Product and the other end to the mains power outlet.
Failure to have the fans operating may lead to over heating and component failure.
Push the rear-panel switch to the “I” side of the switch to turn on the cooling fans. A light on the front panel illuminates and indicates that power is on. Turn off the power switch when the Product is no longer being used.
WCaution
Figure 2. 5322A-LOAD Front Panel
Ieu001.eps
POWER INPUT 12V
10VA MAX.
SAFETYWARNING
READ MANUAL BEFORE USE. NO USER SERVICEABLE PARTS CONTAINEDWITHIN. HAZARDOUSVOLTAGES PRESENT. DO NOT REMOVE COVERS. REFER SERVICETO QUALIFIED PERSONNEL. DISCONNECT POWER AND SIGNAL LEADS BEFORE SERVICING.
FLUKE CORPORATION
www.fluke.com
USB
Figure 3. Grounding Cable Connection
Rear
Ground Cable
DURING USE, TERMINAL MUST BE CONNECTED TO THE PROTECTIVE EARTH
OF THE 5320A
PROTECTIVE
EARTH (GROUND)
ehq101.eps
3
Loading...
+ 5 hidden pages