Each Fluke Networks product is warranted to be free from defects in material and workmanship under normal use and service. The warranty
period is one year and begins on the date of purchase. Parts, accessories, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke Networks authorized reseller, and does not apply to disposable
batteries, cable connector tabs, cable insulation-displacement connectors, or to any product which, in Fluke Networks’ opinion, has been
misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke Networks warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke Networks does not warrant that software will be error free or operate without interruption.
Fluke Networks authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no
authority to extend a greater or different warranty on behalf of Fluke Networks. Warranty support is available only if product is purchased
through a Fluke Networks authorized sales outlet or Buyer has paid the applicable international price. Fluke Networks reserves the right to
invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another
country.
Fluke Networks’ warranty obligation is limited, at Fluke Networks’ option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke Networks authorized service center to obtain return authorization information, then
send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke Networks assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB
Destination). If Fluke Networks determines that failure was caused by neglect, misuse, contamination, alteration, accident or abnormal
condition of operation or handling, or normal wear and tear of mechanical components, Fluke Networks will provide an estimate of repair
costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation
prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE NETWORKS SHALL
NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING
FROM ANY CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held
invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.
The M
enables network professionals to quickly and easily
verify the integrity of Ethernet twisted pair cables. In
one step, the M
cabling for opens, shorts, reversed, crossed, and split
pairs. Simply slide the switch to the Cable position,
press the
automatically scan for any existing faults in your cable.
The specially designed remote unit is provided for
one-person testing of installed cabling. The tone
generator function can be used with the MicroProbe
cable tracer to trace cables and locate cables hidden in
ceilings, walls, floors, and bundles.
ICROMAPPER will test twisted pair
(TEST) button and the M
ICROMAPPER will
MICROMAPPER™
1
MicroMapper
User’s Manual
Features
•Tests for wiring faults and detects opens, shorts,
crossed, reversed, and split pairs. (Split pair fault
detection requires a minimum cable length of
15.75" (40cm))
•Verifies shield integrity
ICROMAPPER’s Remote Identifier enables one
•M
person to test installed cabling
• Easy to read fault display and high speed testing
• Generation of two tones for tracing cables and
locating hidden cables
•Debug-mode for detailed fault identification
results
•Auto-sleep mode to decrease power consumption
MICROMAPPER Kit Content
Your MICROMAPPER kit contains the following:
• 1 M
• 1 M
• Patch cord
• Quick Reference Guide
• Product Manuals CD
ICROMAPPER network cable tester
ICROMAPPER remote
Registration
Registering your product with Fluke Networks gives
you access to valuable information on product updates,
troubleshooting tips, and other support services.
To register, fill out the online registration form on the
Fluke Networks website at
www.flukenetworks.com/registration. If you do not
have Internet access, print the registration form from
the CD included with the product. Fill out the form,
then mail or fax it to the appropriate address for your
country.
2
MicroMapper™
Safety Information
Safety Information
WWarnings
Do not connect MICROMAPPER to a live
circuit as it may damage the unit.
Do not open the unit or attempt to repair
in case of malfunction. Please send it
back to your distributor for repair or
replacement.
Caution
Strong radio frequency fields may cause
inaccurate readings.
Do not drop or get the unit wet. Do not
expose MICROMAPPER to extreme humidity
or direct sunlight.
Contacting Fluke Networks
www.flukenetworks.com
support@flukenetworks.com
+1-425-446-4519
• Australia: 61 (2) 8850-3333 or 61 3 9329 0244
• Beijing: 86 (10) 6512-3435
• Brazil: 11 3044 1277
• Canada: 1-800-363-5853
• Europe: +44 1923 281 300
• Hong Kong: 852 2721-3228
• Japan: +81-3-3434-0181
• Korea: 82 2 539-6311
• Singapore: +65-6738-5655
• Taiwan: (886) 2-227-83199
• USA: 1-800-283-5853
Visit our website at www.flukenetworks.com for a
complete list of phone numbers.
3
MicroMapper
User’s Manual
MICROMAPPER Controls and LEDs
1-23-64-57-8 SHIELD
TONER
SHORT
REVERSED
TEST
MISWIRE
SPLIT PAIRS
LOW BATTERY
M
ICROMAPPER
REMOTE
Table 1. M
Item
ICROMAPPER Controls and LEDs
Description
Number
APair and Shield Indicator LEDs
BToner LED
CTEST button
DREMOTE Adapter with RJ45 Jack
ERJ45 Jack
FOff/Cable/Toner Switch
GFault LEDs
HLow Battery LED
Figure 1. MICROMAPPER Network Cable Tester
4
atx02f.eps
MicroMapper™
Battery
Battery
MICROMAPPER requires four 1.5 AAA batteries. IEC :
LR03. Others : AAA, E92, 4003; JIS : AM 4 ; ANSI : 24A;
1.5 Volt (nominal).
atx03s.bmp
The Battery LED will light up when MICROMAPPER
detects a low battery condition. Using MICROMAPPER
with a low battery may affect the test accuracy. If
M
ICROMAPPER is stored for more than a month, the
battery should be removed.
MICROMAPPER’s Toner Operation
1. Slide the switch on the right side of MICROMAPPER
to the Toner position.
2. Connect the cable to the M
(To send a tone into a patch panel, connect one
end of the included patch cord to the
M
ICROMAPPER’s RJ45 jack and the other end to a
jack on the panel.)
3. To generate tone 1, press and quickly release the
(TEST) button.
4. To generate tone 2, press and hold the
button for two seconds.
5. Use the M
ICROPROBE to trace the connected cable.
The signal reception is strongest near the cable
under test.
6. Slide the switch on the right side to the Off
position to discontinue the tone. (Always power
the unit off to prevent battery drain.)
ICROMAPPER’s RJ45 jack.
(TEST)
5
MicroMapper
User’s Manual
MICROMAPPER Tests
1. Slide the switch on the right side to the Cable
position to turn M
2. Connect one end of the cable to be tested to the
ICROMAPPER’s RJ45 jack.
M
3. Connect the other end of the cable to the
ICROMAPPEr Remote’s RJ45 jack.
M
4. Press (TEST) to view the results.
5. The horizontal LEDs indicate the cable’s integrity
status.
• Green: Pair or Shield is good
• Green flashing: Pair or Shield is faulty
• No light: Pair is open or cable is not shielded
The vertical LEDs indicate the wiring faults and a
low battery status. Wiring faults are: SHORT,REVERSED, MISWIRE, SPLIT PAIRS.
ICROMAPPER on.
6. To find out a fault on a specific pair, use
ICROMAPPER’s diagnostic feature.
M
7. Press and hold
ICROMAPPER will scan each pair and the shield
M
(TEST) for more than 2 seconds.
pausing and flashing each green LED separately. If
a faulty pair is detected, the corresponding fault
status will blink in red.
Note
Push the Remote Terminator onto the
MicroMapper until it snaps into position. This
configuration allows you to conveniently test
patch cables.
6
Fault Status
MicroMapper™
Fault Status
SHORT
1-2 3-6 4-5 7-8
TONER
REVERSED
TEST
MISWIRE
SPLIT PAIRS
LOW BATTERY
SHORT
1
SHIELD
2
3
6
4
5
7
8
SS
OPEN
1
2
3
6
4
5
1-2 3-6 4-5 7-8
TONER
TEST
REVERSED
MISWIRE
SPLIT PAIRS
LOW BATTERY
SHORT
7
8
1
SHIELD
2
3
6
4
5
7
8
SS
1
2
3
6
4
5
7
8
7
MicroMapper
User’s Manual
REVERSED
MIS-WIRE
1-2 3-6 4-5 7-8
TONER
TEST
REVERSED
MISWIRE
SPLIT PAIRS
LOW BATTERY
1-2 3-6 4-5 7-8
TONER
TEST
REVERSED
MISWIRE
SPLIT PAIRS
LOW BATTERY
SHORT
SHORT
SHIELD
SHIELD
SPLIT PAIR
1
2
3
6
4
5
7
8
S
1
2
3
6
4
5
7
8
S
1
2
3
6
4
5
7
1-2 3-6 4-5 7-8
TONER
TEST
REVERSED
MISWIRE
SPLIT PAIRS
LOW BATTERY
SHORT
8
S
SHIELD
1
2
3
6
4
5
7
8
S
1
2
3
6
4
5
7
8
S
1
2
3
6
4
5
7
8
S
8
MicroMapper™
Technical Specifications
Connectors
ICROMAPPER main unit: RJ45 jack
M
Remote Identifier: RJ 45 jack
Pairs tested
1-2, 3-6, 4-5, 7-8, and shield
LED Display
Horizontal: 5 green LEDs for pairs and shield
display
(1 - 2, 3 - 6, 4 - 5, 7 - 8, and SHIELD)
Vertical: 6 red LEDs (TONER, SHORT, REVERSED,
MISWIRE, SPLIT PAIRS, and LOW BATTERY)
Cables test limit
Minimum: 15.75" (40cm); Maximum: 656’ (200 m)
Power
IEC 86-1 (1996-07) --- Primary Batteries - General