FLUKE FLUKE T6-1000 Instructions

Page 1
Demo unit how-to guide
FieldSense voltage measurement without test leads
HOLD
1
Rotate the knob to the FieldSense position.
Insert test probes into
2
Store both test leads in the storage dock.
3
Hold hand firmly on the FieldSense touch point.
the storage dock.
Hold hand firmly on FieldSense ground contact.
Key Takeaways
Hz
Voltage can be measured without metallic contact.
Current and voltage are displayed at the same time (T6-1000). The T6-600 display can be toggled to display both measurements.
The display backlight turns
green when the T6 has a
reliable FieldSense signal.
4
Insert the fork around the ac conductor. Note that the conductor should bottom out in the fork.
5
Press the yellow toggle button to display Hertz. (T6-1000)
Don’t forget
The user must provide
200 A
Hz
=
CAT 600 V
CAT
1000 V
Display turns green for valid measurement.
200 A
HOLD
CAT 600 V
CAT
1000 V
capacitive path to ground
The black test lead must be stored
Maintain good contact with the FieldSense touch point
The ac conductor needs to be as close to the FieldSense sensor as possible by bottoming out in the fork.
Page 2
Demo unit how-to guide
T6 -
1000
Electrical Tester
HOLD
Hz
FieldS
e
nse
FieldSense voltage measurement with separate path to ground
HOLD
1
Rotate the knob to the FieldSense position.
2
Use the black ground lead.
3
Touch the black ground lead to ground.
Use the ground probe.
Key Takeaways
Hz
Voltage can be measured without metallic contact.
Current and voltage are displayed at the same time (T6-1000). The T6-600 display can be toggled to display both measurements.
The display backlight turns
green when the T6 has a
reliable FieldSense signal.
This method of making a FieldSense measurement can be used if the user is standing on an insulated ladder, wearing insulated gloves or otherwise insulated from ground.
4
Insert the fork around the ac conductor. Note that the conductor should bottom out in the fork.
5
Press the yellow toggle button to display Hertz (T6-1000).
200 A
CAT 600 V
CAT
1000 V
Display turns green for valid measurement.
Don’t forget
The ac conductor needs to be as close to the FieldSense sensor by bottoming out in
CAT 600 V
200 A
CAT
1000 V
the fork.
Contact with the FieldSense touch point is not required.
Hz
=
HOLD
©2017 Fluke Corporation.
8/2017 6009799a-en