Fluke FLK-TI-SBC3, FLK-TI-SBP3 User Manual

FLK-TI-SBC3
POWER
Ti SBC3
SMART BATTERY
CHARGER 3
Charging Base/Power Supply with Adapters
Instruction Sheet
The Fluke FLK-TI-SBC3 Charging Base/Power Supply with Adapters charges the Fluke FLK-TI-SBP3 Smart Battery Pack for Thermal Imagers. The FLK-TI-SBC3 consists of a charging base, power supply, and power outlet adapters.
PN 3481481 August 2009
© 2009 Fluke Corporation. All rights reserved. Printed in USA.
Safety Information
Use the FLK-TI-SBC3 only as specied in this instruction sheet or other Fluke product-specic manual. See Table 1 for a list of symbols used on the FLK-TI-SBC3.
A Warning identies hazardous conditions and actions that could cause bodily harm or death.
A Caution identies conditions and actions that could damage the Imager or cause permanent loss of data.
W Warning
To avoid injury:
Do not disassemble or short circuit the battery pack. Do not expose the battery pack to temperatures above 50 °C (122 °F). Do not incinerate or mutilate the battery pack. Use only ac adapters approved by Fluke for the product to charge the battery or power the product.
Table 1. Symbols
Symbol Description
P
"
;
)
W
~
Conforms to requirements of European Union and European Free Trade Association.
Imager connected to battery charger.
Conforms to relevant Australian standards.
Conforms to relevant Canadian and US standards
Important information. See manual.
Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for recycling information.
Charging the Battery
Before using the battery pack for the rst time, charge the battery in the two-bay charging
base for at least two and one-half hours. For complete charging instructions, see the “Ti32, TiR32 Thermal Imagers User Manual.”
Specications
See Table 2 for the specications.
Table 2. Specications
Battery Charging
Charging / Power LED
Dimensions 159.5 mm x 68.9 mm x 51.3 mm (6.28 in x 2.71 in x 2.02 in)
Operating Temperature -10 °C to 70 °C (-14 °F to 158 °F)
Storage Temperature -20 °C to 80 °C (-4 °F to 176 °F) without batteries
Humidity Range 10 % to 95 % non-condensing
10-15 Vdc 2 A or charge battery pack in Imager with included ac
adapter rated: 100-240 Vac 50/60 Hz, 15 V 2 A.
Status Charging LED Power LED
off no battery detected no dc power input
solid green charged dc power present
blinking green charging na
blinking red fault na
How to Contact Fluke
To contact Fluke, call one of the following telephone numbers:
USA: 1-800-760-4523
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-3434-0181
Singapore: +65-738-5655
Anywhere in the world: +1-425-446-5500
Or, visit Fluke’s website at www.uke.com.
To register your product, visit http://register.uke.com.
To view, print, or download the latest manual supplement, visit
http://us.uke.com/usen/support/manuals.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions
of operation or handling. Resellers are not authorized to extend any other warranty on
Fluke’s behalf. To obtain service during the warranty period, contact your nearest Fluke
authorized service center to obtain return authorization information, then send the product
to that Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you.
Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A.
11/99
Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands
Loading...