Fluke FLK-Ti125, FLK-Ti110, FLK-Ti105, FLK-TiR125, FLK-TiR110 User Manual

...
Find it. Fix it. FAst
.
Find it. Fix it. FAst
.
Fluke CNX Series System
Capture critical measurements
WIRELESSLY.
Meet the Fluke CNX Series Wireless Team.
0.0
68.6
71.5
51.2
V AC
A AC A AC A AC
Auto
1 2
3
0.0
27.9
191.2
15.6
V AC
A AC V AC A AC
Auto
1 2
3
0.0
29.3
28.3
29.6
V AC
A AC A AC A AC
Auto
1 2
3
INRUSH
Hz
L1 L2 L3
Determining current unbalance
Motor power cabinet
INRUSH
Hz
INRUSH
Hz
INRUSH
Hz
0.0
46.7
50.1
29.4
V AC
A AC A AC A AC
Auto
1 2
3
OR
Note: Use a wireless multimeter or a thermal imager. Both tools can not be used simultaneously to receive wireless measurements.
TM
your tools—CoNNeCteD. take reaDiNgs quiCker. solve problems Faster.
You see what’s happening with your thermal imager. Now help uncover root causes, by connecting CNX™ wireless current modules to your imager.
Now there’s a fast and convenient way to capture current measurements from up to five wireless modules at once using your thermal imager. New CNX wireless modules communicate with your imager and store both absolute and relative measurement readings right along with the thermal image. Inspect motors and switchgear, breaker panels, fuses and other equipment more thoroughly. Figure out whether those temperature differences are normal or not and start uncovering potential causes. You can also verify that electrical inspections are conducted at 40
% current load—
consistent with best practices.
Download your data to a PC for analysis
®
with SmartView
software. Documenting the thermal images together with current measurements adds validity to your analysis and makes your inspections more thorough. Determine whether you need to bring in other Fluke test and measurement tools, such as a power quality meter, a
®
vibration tester or ScopeMeter
handheld
oscilloscope to fully diagnose problems.
Easier measuring, even in difficult or dangerous locations
Set up wireless modules in an electrical cabinet, near rotating machines, or in harsh environments on equipment you want to monitor. Then step back and take readings from a safe distance or a more comfortable spot. You’ll improve safety by mini­mizing your exposure to those conditions.
Use modules as stand-alone tools too The CNX modules not only communicate with your thermal imager, but can also be used as
WIRELESS TOOLS
The team. Fluke CNX tools work
together. Remotely. Simultaneously.
Conveniently.
stand-alone test tools. Capture measurements over time and then download to a computer later for reporting, tracking and documentation. It’s ideal for preventive maintenance.
Set up is as easy as 1, 2, 3
WIRELESS THERMAL IMAGER
The captain. Display measurements
from up to 5 wireless modules
within the thermal image.
SOFTWARE
The statistician. Get the data from
up to five measurements from
each infrared image in SmartView
analysis and reporting software.
®
It’s free and easy to activate the wireless radio in your Fluke Thermal Imager (wireless is cur­rently available on the following models: Ti125, TiR125, Ti110, TiR110, Ti105, TiR105 and Ti100).
1. Connect your wireless Fluke thermal imager to your computer with the USB cable provided and open the latest version of SmartView® software.
2. Select “Enable CNX wireless system” in the imager’s menu and you’ll be directed to a Fluke website. Simply enter the unit’s serial
Possible Applications
Troubleshooting systems Measure incoming current Measure current loadDetermining current imbalance
Troubleshooting systems
Measuring incoming current
number and your contact information to get an authorization code. Once you’ve entered the code into the SmartView form, the firm­ware download begins.
3. After the download is complete, the CNX mod­ules and thermal imager can communicate and you will begin to realize the benefits of the Fluke CNX wireless system.
View the easy 1, 2, 3 video at:
www.fluke.com/ti-cnx-1-2-3
Easy on your budget
With the free firmware download there’s no additional cost to add the convenience and effi­ciency of wireless capability. No need to return it to Fluke for the upgrade—your imager never leaves your side. The CNX wireless modules are affordable, and can be added as needed…and they are built with the Fluke quality and inno­vation that you demand. You can expect to see additional CNX wireless modules from Fluke in the near future, adding even greater value to your thermal imaging investment.
Measuring current load
These illustrations demonstrate a few different ways the CNX system can be used. Visit our website or ask your distributor for more information and to see other CNX applications.
Note: Use a wireless multimeter OR thermal imager. Both tools can not be used simultaneously to receive wireless instruments.
CAT
CAT
600V
600V
CAT
CAT
300V
300V
L1 L2 L3
CAT
600V
CAT
300V
Note: Use a wireless multimeter or a thermal imager. Both tools can not be used simultaneously to receive wireless measurements.
OR
INRUSH
Hz
CAT
CAT
L2
L1
CAT
CAT
600V
CAT
600V CAT
300V
300V
600V
CAT
600V CAT
600V
CAT
600V CAT
CAT
CAT
300V
300V
CAT
CAT 300V 300V
Note: Use a wireless multimeter or a thermal imager. Both tools can not be used simultaneously to receive wireless measurements.
OR
Note: Use a wireless multimeter or a thermal imager. Both tools can not be used simultaneously to receive wireless measurements.
600V
600V
CAT
CAT
300V
300V
CAT
CAT
600V
600V
CAT
CAT
300V
300V
OR
TM
CNX™ Series Wireless System:
Fluke CNX enabled
Thermal Imagers
FLUKE CNX™ SERIES WIRELESS SYSTEM
Your tools connected. The new Fluke wireless trouble­shooting team works together to help you solve problems faster. See live measurements from multiple modules simultaneously. Customize your tool set by mixing and matching to suit your unique testing needs and provide maxi­mum flexibility.
Wireless will change the way you work
No more running around
Pen and paper no longer
needed
No more waiting around
No more uncomfortable
positions
AC Voltage
Module
AC Current
Clamp Module
AC Current
Clamp Module
iFlexTM AC
Current Clamp
Module
CNX a3000
Model Description
Kits (
Buy a system or kit a nd save)
FLK-Ti125/C3i 30Hz Industrial-Commercial Thermal Imager 30 Hz with 3 CNX-i3000
FLK-Ti100/C1a 9Hz General Purpose Thermal Imager 9 Hz with 1 CNX-a3000
CNX main units
FL K-T i125 Thermal Imager for Industrial and Commercial Applications
F L K -T i110 Thermal Imager for Industrial and Commercial Applications
FL K-Ti105 Thermal Imager for Industrial and Commercial Applications
FL K-T i R125 Building Diagnostic Thermal Imager
F L K -T iR110 Building Diagnostic Thermal Imager
FL K-Ti R105 Building Diagnostic Thermal Imager
FLK-Ti100 General Use Thermal Imager
CNX 3000 Wireless Multimeter
CNX modules
FLK-CNX i3000 iFlex AC Current Clamp Module
FLK-CNX a3000 AC Current Clamp Module
FLK-CNX v3000 AC Voltage Module
FL K-C NX t30 00 K-Type Temperature Module
PC adapter
FLK-CNX PC3000 PC Adapter
CNX a3000
FLK-CNX 3000 Series iFlexTM Module and accessories
FLK-CNX 3000 Series AC Current Clamp Module
FLK-CNX 3000 Series AC Voltage Module and accessories
FLK-CNX 3000 Series K-type Temperature Module and accessories
Allows for wireless transfer of logged data or thermal images into pc software (not valid for the thermal imager)
CNX i3000
CNX t3000
K-Type
Temperature
Module
*Find out more about t he benefits of wireless measurement capture at www.fluke.com/thermography.
Your Fluke Ti1XX thermal imager can be upgraded FREE to enable its CNX wireless capabilities. Connect your thermal imager to your PC with the included USB cable. Open SmartView® software and update to the most recent version. Then select the thermal imager icon, pull down the menu and select Enable CNX™.
Note: Upgrade is not available in all countries at this time.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V.
PO Box 1186, 5602 BD Eindhoven, The Netherlands
Modification of this document is not permitted without written permission from Fluke Corporation.
For more information call:
In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2013 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 2/2013 4314882A_EN
Loading...