Fluke Fiber OneShot PRO Quick Reference Manual

PN 4805467, May 2016
©2016 Fluke Corporation All product names are trademarks of their respective companies.
FIBER ONESHOT™ PRO
Singlemode Fiber Troubleshooter
Accessing the Users Manual
This guide provides basic information to help you get started using the FIBER QNESHOT PRO Singlemode Troubleshooter. For additional information, see the FIBER Q
NESHOT PRO Users
Manual on the Fluke Networks website.
Battery Installation
fjy03.eps
AA
IEC LR6
Note: Fluke Networks recommends alkaline batteries.
2
FIBER ONESHOT PRO Quick Reference Guide
Display Features
gmh01.eps
When you press , CheckActive
shows and the troubleshooter looks for an optical signal on the fiber. If there is a singlemode signal stronger than approximately
-29 dBm on the fiber, ACTIVE LINE blinks and the troubleshooter will not do a test.
WCaution
If ACTIVE LINE blinks, immediately disconnect the troubleshooter from the fiber. Optical power levels more than +7 dBm can cause damage to the detector in the troubleshooter.
When the low battery symbol shows, replace the batteries soon. See page 1.
The digits show the fiber length in feet, kilofeet, meters, or kilometers.
3
Display Features
sec: Shows when you look at the setting for the backlight timer. The setting is in seconds.
dB: Shows when you look at the setting for the reflection limit. The setting is in decibels.
dB: Shows when the display shows the reflectance of an incident on the fiber. The measurement is in decibels.
: Shows when the display shows the power loss of an
incident on the fiber. The measurement is in decibels.
RL: Result loss.
MORE : Shows when the troubleshooter finds more than one incident. Press   to see more incidents. The numbers show the number of the incident and the total number of incidents. The troubleshooter shows up to 9 incidents. If there are more than 9 incidents on the fiber, the last
blinks when you look at the ninth incident.
SAVED: Shows after a test. The troubleshooter automatically saves the test results.
TESTING: Shows as the troubleshooter does a test.
BREAK OR END: Shows when the troubleshooter shows the distance to a break or the end of the fiber.
: The measurement is above or below the range that the troubleshooter can show, or the troubleshooter cannot give a more accurate measurement.
RESULT: Shows when you look at saved results.
Settings for the troubleshooter. LOSS LIMITW and REFLECTION LIMITW blink if a measurement is equal to or
greater than the limit you select.
4
FIBER ONESHOT PRO Quick Reference Guide
Settings
To change the settings on the troubleshooter:
1
Hold down until the settings menu shows.
2
To select a setting to change, press , then press .
3
Use to change the setting.
4
Press or to save the setting.
5
To exit the settings menu, hold down for 4 seconds. To exit and do a test, press
.
BACKLIGHT: Timer for the display backlight.
I.O.R.: Index of refraction.
ft/m/kft/km: Unit for length measurements.
LOSS LIMIT: Sets the minimum level at which the troubleshooter shows the warning LOSS LIMITW for an incident.
REFLECTION LIMIT: Sets the minimum size at which the
troubleshooter shows the warning REFLECTION LIMITW for an incident.