Each Fluke Networks product is warranted to be free from defects in material and
workmanship under normal use and service unless stated otherwise herein. The warranty
period for the mainframe is one year and begins on the date of purchase. Parts,
accessories, product repairs and services are warranted for 90 days, unless otherwise
stated. Ni-Cad, Ni-MH and Li-Ion batteries, cables or other peripherals are all considered
parts or accessories. The warranty extends only to the original buyer or end user
customer of a Fluke Networks authorized reseller, and does not apply to any product
which, in Fluke Networks’ opinion, has been misused, abused, altered, neglected,
contaminated, or damaged by accident or abnormal conditions of operation or handling.
Fluke Networks warrants that software will operate substantially in accordance with
its functional specifications for 90 days and that it has been properly recorded on nondefective media. Fluke Networks does not warrant that software will be error free or
operate without interruption.
Fluke Networks authorized resellers shall extend this warranty on new and unused
products to end-user customers only but have no authority to extend a greater or
different warranty on behalf of Fluke Networks. Warranty support is available only if
product is purchased through a Fluke Networks authorized sales outlet or Buyer has
paid the applicable international price. To the extent permitted by law, Fluke Networks
reserves the right to invoice Buyer for repair/replacement when a product purchased in
one country is submitted for repair in another country.
For a list of authorized resellers, visit
Fluke Networks warranty obligation is limited, at Fluke Networks option, to refund of
the purchase price, free of charge repair, or replacement of a defective product which is
returned to a Fluke Networks authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke Networks authorized service
center to obtain return authorization information, then send the product to that
service center, with a description of the difficulty, postage and insurance prepaid (FOB
destination). Fluke Networks assumes no risk for damage in transit. Following warranty
repair, the product will be returned to Buyer, transportation prepaid (FOB destination).
If Fluke Networks determines that failure was caused by neglect, misuse, contamination,
alteration, accident or abnormal condition of operation or handling, or normal wear and
tear of mechanical components, Fluke Networks will provide an estimate of repair costs
and obtain authorization before commencing the work. Following repair, the product
will be returned to the Buyer transportation prepaid and the Buyer will be billed for the
repair and return transportation charges (FOB Shipping point).
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
FLUKE NETWORKS SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY
CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied
warranty, or exclusion or limitation of incidental or consequential damages, the
limitations and exclusions of this warranty may not apply to every buyer. If any provision
of this Warranty is held invalid or unenforceable by a court or other decision-maker of
competent jurisdiction, such holding will not affect the validity or enforceability of any
other provision.
The FI-3000 FiberInspector Pro is hand-held probe used to inspect
fiber optic endfaces on MPO connectors. You use the probe with
FI-I
your mobile device and the
endfaces and share and save test results.
Registering your product with Fluke Networks gives you access to
valuable information on product updates, troubleshooting tips,
and other support services. If you purchased a Gold Support plan,
registration also activates your plan.
N
application to view and analyze
To register, fill out the online registration form on the Fluke
Networks website at
Kit Contents
For a list of the contents of your FI-3000 kit, see the list that came
in the product’s box or see the lists of models and accessories on
the Fluke Networks website. If something is damaged or missing,
contact the place of purchase immediately.
Table 1 shows the symbols used on the probe or in this manual.
Warning: Risk of fire, electric shock, or personal injury.
Warning or Caution: Risk of damage or destruction to equipment or
software. See explanations in the manuals.
Consult the user documentation.
40 year Environment Friendly Use Period (EFUP) under China
Regulation - Administrative Measure on the Control of Pollution
Caused by Electronic Information Products. This is the period of time
before any of the identified hazardous substances are likely to leak
out, causing possible harm to health and the environment.
Conforms to the Appliance Efficiency Regulation (California Code of
Regulations, Title 20, Sections 1601 through 1608), for small battery
charging systems.
Conformite Europeene. Conforms to requirements of European
Union directives. Safety requirements for electrical equipment for
measurement, control, and laboratory use.
This Product complies with the WEEE Directive marking
requirements. The affixed label indicates that you must not discard
this electrical/electronic product in domestic household waste.
Product Category: With reference to the equipment types in
the WEEE Directive Annex I, this product is classed as category 9
"Monitoring and Control Instrumentation" product. Do not dispose
of this product as unsorted municipal waste.
To return unwanted products, contact the manufacturer’s web site
shown on the product or your local sales office or distributor.
This Product contains a lithium-ion battery. Do not mix with the solid
waste stream. Spent batteries should be disposed of by a qualified
recycler or hazardous materials handler per local regulations. Contact
your authorized Fluke Service Center for recycling information.
EMC approval for Korea.
Class A Equipment (Industrial Broadcasting & Communication
Equipment).
This product meets requirements for industrial (Class A)
electromagnetic wave equipment and the seller or user should
take notice of it. This equipment is intended for use in business
environments and is not to be used in homes.
Before you use the battery for the first time, charge the battery for
about 2 hours with the tester turned off (Figure 2).
The battery takes approximately 5 hours to fully charge when the
probe is turned off.
A fully-charged battery operates for approximately 10.8 hours of
typical use. You can use the setting in the app to
reduce battery usage. See page 22.
Note
You do not need to fully discharge the battery
before you recharge it.
The battery will not charge if its temperature is
outside the range of 32 °F to 113 °F (0 °C to 45 °C)
or if it has a fault and must be replaced. The LED
blinks red and green if the battery will not charge.
Red: Charging
Green: Fully charged
Blinking red/green: The battery will
not charge. See the note.
application at no charge from
the Apple® App Store® or from the Google Play™ store to your iOS®
or Android™ mobile device. You can use the app on smart phones
and tablets.
Note
For a list of mobile devices that fully support the
You can attach the MPO inspection tips to the probe with the MPO
key on the left or right, as shown in Figure 6. This lets you rotate
the probe when a cabinet door or other surface is in the way of the
probe’s handle (Figure 7).
The setting at the bottom of the Live View screen lets
you make the fiber numbers on endface diagrams agree with the
numbers on the connector.
• Set the to the key
position you use on the probe.
• Set the to the
opposite side from the key position you use on the probe.
When you set the correctly for the type of adapter,
fiber number 1 is in the upper-right corner of the endface image.
Insert the probe tip into a bulkhead connector, or into an
adapter attached to a patch cord (Figure 8).
The app shows a live image of the endface. You can adjust the
image as shown in Figure 9.
Press to focus the image if necessary, then press or tap
Test on your mobile device.
3.When the LEDs on the probe show the pass () or fail ()
result, you can remove the probe from the connector.
4.After the probe transmits the test results to your device, the
app shows the TEST RESULT SUMMARY screen. You can then Save or the result or tap the endface graphic to see
detailed results. See “Endface Image Screens” on page 17.
To see the live image again, tap or Live.
Patch cord
Adapter*
* The adapter’s key position affects the fiber numbers
in your test results. See “Set the Key Position” on
page 13.
Fluke Networks recommends that you use a mechanical cleaner
such as the Quick Clean™ fiber endface cleaner. Figure 12 shows
how to use a Quick Clean cleaner to clean MPO connectors. For
details, see the documentation included with the cleaner.
On the Live View screen, tap then tap Manage Projects.
On the Projects screen, select one or more projects, then tap
.
• The FI-IN app can turn off the probe after you do nothing with
the probe for 5, 10, 15, or 20 minutes.
• If you turn off the
while it is connected to the app.
• If the probe is not connected to the app, it turns off after you
do nothing with the probe for 10 minutes.
In the
If necessary, tap the slider to turn it on.
3. Tap
-
F
app, tap then tap Settings.
I
I
N
, tap a time period, then tap
function, the probe stays on
Learn More
The Fluke Networks Knowledge Base answers common questions
about Fluke Networks products and provides articles on cable
testing techniques and technology.
.
To access the Knowledge Base, log on to
then click SUPPORT >
.
Accessories
For a complete list of options and accessories visit the Fluke
Networks website at .
This product uses freeRTOS and FatFS software. The software
license statements and files that contain the binary and source
code for the open source software are on the disk supplied with
the product. These files are provided to meet legal requirements.
You do not need these files to use the probe. For more
Fluke Networks operates in more than 50 countries worldwide. For
more contact information, visit our website.
Operating: -10 °C to +45 °C (+14 °F to +113 °F)
Storage: -10 °C to +60 °C (+14 °F to +140 °F)
Operating: 0 % to 95 % (32° F to 95° F, 0° C to 35°C)
RH non-condensing
Storage: 0 % to 95 % (95° F to 113° F, 35° C to 45°C)
RH non-condensing
Operating: 4,000 m (13,123 ft) (3,200 m (10,499 ft)
with AC adapter)
Storage: 12,000 m (39,370 ft)
2 g, 5 Hz to 500 Hz, 30 g shock
~ 1200 x 400, 10 frames per second
4800 µm x 1600 µm
view
Low magnification:
High magnification: 680 µm x 510 µm
Environment; IEC 61326-2-1
CISPR 11: Group 2, Class A
Group 2: Equipment contains ISM RF equipment
in which radio-frequency energy in the frequency
range 9 kHz to 400 GHz is intentionally
generated and used or only used, in the form
of electromagnetic radiation, inductive and/or
capacitive coupling, for the treatment of material or
inspection/analysis purposes.
Class A: Equipment is suitable for use in all
establishments other than domestic and those
directly connected to a low voltage power supply
network which supplies buildings used for domestic
purposes. There may be potential difficulties in
ensuring electromagnetic compatibility in other
environments, due to conducted and radiated
disturbances.
USA (FCC): 47 CFR 15 Intentional Radiators:
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation. (15.19). Changes or
modifications not expressly approved by Fluke could
void the user's authority to operate the equipment.
(15.21)
Emissions which exceed the levels required by CISPR
11 can occur when the Product is connected to a
test object.
168 mm x 137 mm x 54 mm (6.625 in x 5.375 in x
2.125 in) (with no dust cap or adapter tip)
Length with dust cap: 191 mm (7.5 in)
326 gm (11.5 oz) (with dust cap and no adapter tip)
* For more information, go to www.flukenetworks.com/support/manuals, select the