Safety ............................................. IEC 60950-1 Overvoltage Category II
Electromagnetic
Compatibility (EMC) ..................... IEC 61326-1: Industrial Electromagnetic
Group 1: Equipment has intentionally generated and/or use conductively
coupled radio-frequency energy which is necessary for the internal functioning
of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than
domestic and those directly connected to a low voltage power supply network
which supplies buildings used for domestic purposes. There may be potential
diculties in ensuring electromagnetic compatibility in other environments,
due to conducted and radiated disturbances.
Korea (KCC)
Class A: Equipment meets requirements for industrial electromagnetic wave
equipment and the seller or user should take notice of it. This equipment is
intended for use in business environments and not to be used in homes.
.............................. Class A Equipment (Industrial Broadcasting &
Environment
CISPR 11: Group 1, Class A
Communication Equipment)
Symbols
Symbols used on the Product and in this document are explained below.
Symbol
»
Consult user documentation.
WARNING - RISK OF DANGER. Consult user documentation.
WARNING. HAZARDOUS VOLTAGE. Risk of electric shock.
Conforms to European Union directives.
This product complies with the WEEE Directive marking
requirements. The axed label indicates that you must not discard
this electrical/electronic product in domestic household waste.
Product Category: With reference to the equipment types in the
WEEE Directive Annex
“Monitoring and Control Instrumentation” product. Do not dispose of
this product as unsorted municipal waste.
Description
I, this product is classed as category 9
EDBC290
External Dual-Bay Battery Charger
Instructions
Introduction
EDBC290 (the Product or Charger) is an external battery charger for
compatible Li-ion batteries used in Fluke test tools. A separate mainspower adapter is included to provide 19 V dc at 3.16 A maximum.
The EDBC290 is an SMBus master mode smart charger with a
microprocessor-controlled charging circuit for Li-ion batteries. The dualbay holds one or two batteries and automatically controls the charging
process. LED indicators, one for each battery bay, show the charge
status.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for one
year from the date of purchase. This warranty does not cover fuses, disposable
batteries, or damage from accident, neglect, misuse, alteration, contamination,
or abnormal conditions of operation or handling. Resellers are not authorized to
extend any other warranty on Fluke’s behalf. To obtain service during the warranty
period, contact your nearest Fluke authorized service center to obtain return
authorization information, then send the product to that Service Center with a
description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH
AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED.
FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR
THEORY. Since some states or countries do not allow the exclusion or limitation
of an implied warranty or of incidental or consequential damages, this limitation of
liability may not apply to you.
11/99
PN 5099121
May 2019
© 2019 Fluke Corporation. All rights reserved.
Product specications are subject to change
without notice.

Safety Information
A Warning identies conditions and procedures that are dangerous to the
user.
Warning
To prevent possible electrical shock, re, or personal injury:
•
Read these instructions carefully before using the Product.
• Do not alter the Product and use only as specied, or the
protection supplied by the Product can be compromised.
• Do not use the Product if it is altered or damaged.
• Before each use, inspect the Dual-bay Charger, the Battery
Pack, the Power Adapter and mains cord for any damage. Do
not use parts that are cracked or damaged. Use only the mains
power cord and connector approved for the voltage and plug
conguration in your country and rated for the Product.
•
Do not open the Product, it has no user-serviceable parts inside.
• Replace the mains power cord if the insulation is damaged or if
the insulation shows signs of wear.
• Use the Product only for charging Li-ion batteries as specied
for use with Fluke test tools.
•
Use the provided power adapter only or the Product safety
features may become inoperative or the Charger may become
defective.
• Read the instructions for safe use and handling of Li-ion
batteries, see the instruction sheet for the battery.
• Adhere to local and national safety codes concerning the use
and disposal of Charger and Li-ion Batteries.
Unpack
Check the contents of the shipping box for completeness. If a part is
missing or damaged, contact the Fluke distributor or the nearest sales or
service oce.
The EDBC290 includes:
• Dual-Bay Battery Charger (Totex U85104)
• Universal Mains Power Adapter,19 Vdc at 3.16 A maximum (Channel
Well Technology KPL-060K-VI)
• Universal Power Cord (male to female, according IEC 60320 style
C13 and C14).
• Set of Power Plug Adapters supporting dierent types of wall outlets
• Instructions (this document).
• Slot Insert Caps (x2), inserted in charging bays. Keep installed for
charging the Fluke supported batteries.
Operation
To set up and charge a battery:
1. Connect the mains power adapter to a mains outlet.
2. Insert the DC plug of the power adapter into the Charger.
25%
50%
75%
+
100%
C
D
T
-
3. Insert one or two batteries into the external Charger. Be careful to
correctly align the battery contacts.
4. Observe the LED indicators on the Charger:
LED state Charger status
O Power on or standby
Green, blinking Charge in progress
Green, steady on Charge complete
Red, steady on Battery or charger error
After charging, press the TEST button on the battery to check the battery
charge. The four built-in LEDs show the current status.
Cleaning
Before cleaning, separate the Charger from the power adapter and
battery. Disconnect the power adapter from the mains and mains cord.
Use a damp cloth and a mild detergent to clean the Charger and power
adapter. Do not use abrasives, solvents, or alcohol.
Troubleshooting
In case of an error, the LEDs in the Charger ash at a high rate to
indicate a possible battery problem. Insert a known good battery to
determine if the error is caused by the battery or by a defective Charger.
Specications
Charger Bay
DC input voltage ........................ 19 V dc input,
Adapter requirement .................. 19 Vdc / 3.16 A
Input voltage range .................... 15 V dc to 23 V dc
Supported Batteries: BP291, BP290
Voltage .......................................10.8 V nominal (3S)
Charging current ........................ 3.16 A, dynamically controlled
Capacity
BP291..................................... 5000 mAh
..................................... 2500 mAh
BP290
Mains Power Adapter
AC input voltage......................... 100 V ac to 240 Vac (± 10 %), 47 Hz to 63 Hz
AC input current ......................... 1.7 A
AC inlet ...................................... IEC 60320, style C14
Power rating ............................... 60 W
Maximum output current
DC output voltage ...................... 19 V dc ±5 %
Output polarity
DC output cable length .............. 1.5 m
Environmental
Operating temperature ............... 0 °C to 40 °C (determined by battery)
Storage temperature .................. -20 °C to 60 °C
Maximum relative humidity ........ 10 % to 90 %, non-condensing
Maxmum altitude
Dimensions
Charger bay ............................... 125 mm x 122 mm x 54 mm
Mains power adapter ................. 115 mm x 52 mm x 32 mm
Weight
Charger bay
Mains power adapter ................. 0.250 kg
Mains cable and plug set ........... 0.475 kg
............................ center contact positive
........................ 2000 m
............................... 0.265 kg
center contact positive
............ 3.16 A
recovery time: 2 hours