LIMITED WARRANTY & LIMITATION OF LIABILITY
LIMITED WARRANTY & LIMITATION OF LIABILITY
Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Fluke's opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center or send the product, with a description of the difficulty, postage and insurance prepaid (FOB Destination), to the nearest Fluke authorized service center. Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that the failure was caused by misuse, alteration, accident or abnormal condition of operation or handling, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.
Fluke Corporation Fluke Industrial B.V. P.O. Box 9090 P.O. Box 90 Everett WA 7600 AB Almelo 98206-9090, USA The Netherlands
SERVICE CENTERS
To locate an authorized service center,
visit us on the World Wide Web:
http://www.fluke.com
or call Fluke using any of the phone numbers listed below:
+1-888-993-5853 in U.S.A. and Canada
+31-40-2675200 in Europe
+1-425-446-5500 from other countries
®
EBC290
External Battery Charger
Instruction Sheet
Introducing the EBC290
EBC290 is an External Battery Charger for compatible Li-ion batteries as used in Fluke Test Tools. EBC290 is powered by Power Adapter BC190 as supplied with Test Tool Fluke 190 Series II. Instead of Power Adapter Model BC190 you can also use Model BC430. EBC290 is provided with a microprocessor controlled charging circuit to optimally charge the battery.
Unpacking
Following items must be included in the shipment:
EBC290 External Battery Charger.
Instruction Sheet (this document).
Check the contents of the shipping box for completeness. If something in the box has been damaged or is missing, contact your distributor or the nearest FLUKE sales or service office immediately.
Safety Information
Read First: Safety Information. To ensure safe operation of the charger, follow these instructions:
Read the operating instructions before use and follow all applicable safety instructions.
Use the Product only as specified in the operating instructions; otherwise the device’s safety features may become inoperative.
Use the Product only with the Li-ion batteries as specified for use with Fluke Test Tools. Use Power Adapter BC190 or BC430 to supply the Battery Charger, otherwise the device’s safety features may become inoperative or the charger may become defective.
Read the instructions for safe use and handling of Li-ion batteries as indicated in the Battery’s Instruction Sheet.
Before each use, inspect Battery Charger, Battery and Power Adapter for any damage. Do not use parts that are cracked or damaged.
Adhere to local and national safety codes concerning the use and disposal of Charger and Li-ion Batteries.
October 2010. © 2010 Fluke Corporation. All rights reserved. Printed in the EU. All product names are trademarks of their respective companies.
Symbols
Risk of Danger. Important information. See Instruction Sheet.
Do not dispose of this product as unsorted municipal waste. Go to Fluke's website for recycling information.
Conforms to relevant European standards.
Specifications
Electrical Specifications
Power connection BC190 or BC430 Adapter requirement 17.8 V / 0.84 A Input current limitter
714 mA ±5% Input voltage range 15 to 23 V Batteries BP291 capacity 52 Wh Charge time 5.5 Hours Charge operating range 0 to 45°C (determined by battery) Charge disable protection (smbus controlled)
54°C ±3°C battery temp
(determined by battery) Charge disable protection (hardware controlled)
58°C ±3°C battery temp
(determined by battery)
General Specifications
Temperature: Operating
Non Operating (Storage)
0 °C to +45 °C (determined by
battery)
-20°C to +60 °C
Maximum Relative Humidity Non Operating (Storage):
Operating: 0 ... 10 °C 10 ... 30 °C 30 ... 40 °C 40 ... 45 °C
No precipitating (noncondensing)
Recovery time two hours
No precipitation (noncondensing)
95 ± 5 %
75 ± 5 %
45 ± 5 % Emission and Immunity EN-IEC-61326-1
(first edition 2005). Height x Width x Depth (excluding battery)
44 x 65 x 100 mm
Weight 85 g
Using the EBC290
To use the EBC290, follow these instructions (Refer to Figure
1):
1. Connect the Power Adapter BC190 (or BC430) to a mains outlet and insert the DC plug of the Power Adapter into the External Charger.
1
3
4
2
Fig. 1
2. Insert the battery to be charged into the External charger. Take careful notice of the correct placement of the battery.
3. Observe the green LED indicator:
- Slow flashing indicates that the battery is charging.
- Continuously on indicates that the battery is fully charged.
- Fast flashing indicates a battery error.
4. During the charging process the number of segments to turn on in the battery display will increase over time. All segments on indicates that the battery is charged to 100 % of its present capacity.
Cleaning
Before cleaning, separate the product from Power Adapter and Battery. Clean the EBC290 with a damp cloth and a mild detergent. Do not use abrasives, solvents, or alcohol.
Troubleshooting
In case of an error, the green LED in the Charger will flash at a high rate which indicates a possible battery problem. When available, insert another battery to determine is the error is caused by the battery or by a defective charger.
Loading...