DTX-PLA002PRP
Replacement Parts for DTX-PLA002
Permanent Link Adapters
Installation Instructions
The DTX-PLA002PRP is a set of contact tips and latches that
replace worn tips and latches on DTX-PLA002 permanent link
adapters.
The kit comes with the following:
•
Two 8-pin modular (RJ45) tips
•
Two latches
•
Two screws
•
Two conductive washers
•
Installation instructions
PN 2712841 (English) July 2006
© 2006 Fluke Corporation. All rights reserved. Printed in USA.
All product names are trademarks of their respective companies.

Replacing the Tip or Latch
1
Remove the DTX-PLA002 adapter from the DTX tester.
2
Use a Phillips screwdriver to loosen the screw on the
connector case; then remove and replace the tip or latch as
shown below.
3
Verify that the conductive washer is on the case screw as
shown below.
4
Reassemble the connector case, noting the orientation of the
beveled edge on the socket; then tighten the screw.
Replacing the Tip and Latch
eio01.eps

Contacting Fluke Networks
www.flukenetworks.com
support@flukenetworks.com
+1-425-446-4519
•
Australia: 61 (2) 8850-3333 or 61 (3) 9329-0244
•
Beijing: 86 (10) 6512-3435
•
Brazil: 11 3044 1277
•
Canada: 1-800-363-5853
•
Europe: +44-(0)1923-281-300
•
Hong Kong: 852 2721-3228
•
Japan: 03-3434-0510
•
Korea: 82 2 539-6311
•
Singapore: 65 6799-5566
•
Taiwan: (886) 2-227-83199
•
USA: 1-800-283-5853
•
Anywhere in the world: +1-425-446-4519
Visit our website for a complete list of phone numbers.

Specifications
Life of tip contacts (typical): > 5,000 cycles
See the DTX Series CableAnalyzer Technical Reference Handbook
and the DTX-PLA002 Instruction Sheet for additional
specifications.
LIMITED WARRANTY AND LIMITATION OF LIABILITY
Fluke Networks mainframe products will be free from defects in material
and workmanship for 1 year from the date of purchase. Parts, accessories,
product repairs and services are warranted for 90 days, unless otherwise
stated. Ni-Cad, Ni-MH and Li-Ion batteries, cables or other peripherals are
all considered parts or accessories. This warranty does not cover damage
from accident, neglect, misuse, alteration, contamination, or abnormal
conditions of operation or handling. Resellers are not authorized to extend
any other warranty on Fluke Networks’ behalf. To obtain service during
the warranty period, contact your nearest Fluke Networks authorized service center to obtain return authorization information, then send your
defective product to that Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH
AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED.
FLUKE NETWORKS IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY
CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential
damages, this limitation of liability may not apply to you.
Fluke Networks
PO Box 777
Everett, WA 98206-0777
4/04
USA