Fluke 922 Data Sheet

Fluke 922
Airflow Meter/
Micromanometer
Technical Data
Today’s HVAC technicians need a simple solution for diagnosing ventilation issues. The Fluke 922 makes airflow measurements easy by combin­ing pressure, air flow, and velocity into a single, rugged meter. Compatible with most pitot tubes, the Fluke 922 allows technicians to conve­niently enter their duct shape and dimensions for maximum measurement accuracy.
The Fluke 922 Airflow Meter helps you:
Monitor air pressure across
key HVAC components
Ensure proper air flow
balance
Promote good indoor air
quality
Maintain a comfortable
environment
Use the Fluke 922 to:
Measure pressure drops
across filters and coils
Match ventilation to occupant
loads
Monitor indoor vs. outdoor
pressure relationships and manage the building envelope
Perform duct traversals for
accurate airflow readings
Features:
Powerful meter provides
differential and static pres­sure, air velocity and flow readings
Rugged design built for field
use
Easy to use without sacrific-
ing performance
User-defined duct shape and
size for maximum airflow accuracy
Convenient colored hoses
help you properly diagnose pressure readings
Bright, backlit display
for clear viewing in all environments
Min/Max/Average/Hold func-
tions for easy data analysis
Auto power off saves
battery life
Fluke 922 Airflow Meter Specifications
N10140
Feature Range Resolution Accuracy
Operating Specifications
Air Pressure ± 4000 Pascals
Air Velocity 250 to 16,000 fpm
Air Flow (Volume) 0 to 99,999 cfm
Temperature 0 °C to 50 °C
General Specifications
Operating Temperature 0 °C to +50 °C (+32 °F to +122 °F)
Storage Temperature -40 °C to +60 °C (-40 °F to +140 °F)
Operating Relative Humidity
IP Rating IP40
Operating Altitude 2000 m
Storage Altitude 12000 m
EMI, RFI, EMC Meets requirements for EN61326-1
Vibration MIL-PREF-28800F, Class 3
Max Pressure at Each Port
Data Storage 99 readings
Warranty 2 years
Power Four AA batteries
Typical Battery Life 375 hours without backlight, 80 hours with backlight
± 16 in H2O ± 400 mm H2O ± 40 mbar ± 0.6 PSI
1 to 80 m/s
0 to 99,999 m3/hr 0 to 99,999 l/s
32 °F to 122 °F
0 % to 90 %, non-condensing
10 PSI
1 Pascal
0.001 in H2O
0.1 mm H2O
0.01 mbar
0.0001 PSI
1 fpm
0.001 m/s
1 cfm 1 m3/hr 1 l/s
0.1 °C
0.1 °F
± 1 % + 1 Pascal ± 1 % + 0.01 in H2O ± 1 % + 0.1 mm H2O ± 1 % + 0.01 mbar ± 1 % + 0.0001 PSI
± 2.5 % of reading at 2000 fpm (10.00 m/s)
Accuracy is a function of velocity and duct size
± 1 % + 2 °C ± 1 % + 4 °F
Fluke 922 comes complete with the following:
Fluke 922 Airflow Meter, Two Rubber Hoses, Wrist Strap, Four AA Batteries 1.5 V Alkaline, Users Manual and Soft Carrying Case
Fluke 922/Kit comes complete with the following:
Fluke 922 Airflow Meter, 12 in. pitot tube, ToolPak
TM
, Two Rubber Hoses, Wrist Strap, Four AA Batter­ies 1.5 V Alkaline, Users Manual and Hard Carrying Case
Ordering Information
Fluke-922 Airflow Meter Fluke-922/Kit Airflow Meter with
12 in Pitot Tube
PT12 Pitot Tube, 12 in
Optional accessories
PT12
Pitot Tube, 12 in
TPAK
ToolPak
Fluke. Keeping your world up and running.
Fluke Corporation PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or
TM
Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2006, 2007 Fluke Corporation. All rights reserved. Specifications subject to change without notice. Printed in U.S.A. 8/2007 2791462 D-EN-N Rev C
®