Fluke 700HPPK Specifications

700HPPK
Pneumatic Test
Pump Kit
Generate 21 MPa (3000 psi) easily in the field, without liquid contamination or the hazard of a pressurized gas cylinder
The Fluke Calibration 700HPPK Pneumatic Test Pump Kit generates and adjusts pneumatic pressures up to 21 MPa (3000 psi), with­out requiring a nitrogen bottle or other external pressure supply. It supplies pressure to devices under test (DUTs) that include transmit­ters, controllers, pilots, digital and analog gauges, and more. It’s the perfect solution for generating high pressure in the field, where conditions and operating surfaces can vary.
The 700HPPK is the ideal choice for calibration techni­cians, test engineers, and instrument technicians working in industries like natural gas transmission and distribution, process, aerospace and defense, who need a simple-to-use, safe and portable pressure source that they can depend on in a wide variety of conditions.
The 700HPPK contains both a calibration manifold and high pressure pump to generate and finely adjust pressures . A second model, the 700HPP, is available for people who only prefer a high pressure source.
700HPPK features at a glance
Generate and adjust pneumatic pres­sures up to 21 MPa (3000 psi)
Rugged, portable and stable enough to go anywhere—on any surface
Reaches pressure in 20 seconds to full scale into a 30 cm volume
Detachable pressure adjustment system for adjusting pressure, con­necting reference and test devices on bench and in field, and isolating and venting pressure
Easily switch out reference gauges without requiring PTFE tape or tools
2-meter (6.5 foot) pressure line and assorted pressure fittings enable a wide variety of possible connections
In-line filter and desiccant systems protects device from contamination from the DUT
Technical Data
4
5
10
3
7
6
1
The desiccant tube protects against
contamination from inlet gas.
2
The inlet valve (700HPPK only) is conveniently
2
8
located at the bottom of the calibration manifold. Opening and closing this valve helps to stabilize the pressure faster.
9
3
The vent valve lets you vent the pressure with
a simple turn of a knob (HPPK only).
4
The pump handle lets you generate pressure
easily and without physical straining.
5
The variable volume control lets you adjust the
pressure and achieve the exact target pressure on the reference gauge (HPPK only).
6
The gauge port enables you to connect a
reference gauge to the calibration manifold (HPPK only).
1
2 Fluke Corporation 700HPPK Pneumatic Test Pump Kit
7
The calibration manifold (700HPPK only)
attaches and detaches easily with quick detent pins, so it’s easy to set up in the field.
8
External line providing simple and fast
connection to the Device Under Test.
9
Inlet port connecting the pump and adjustment
manifold.
10
The calibration manifold attaches to the pump
bracket.