Fluke 572-2 Specifications

Page 1
572-2 Infrared Thermometer
The best choice when things are really hot
Technical Data
The Fluke 572-2 Infrared Thermometer is the one product you can use in high-temperature industrial environments all around the world. Whether you work in power utility, metal refining and smelting, glass, cement or petrochemical envi­ronments, the new 572-2 allows you to carry the most trusted name in test tools anywhere you need accurate, high­temperature and high distance-to-spot measurements.
With a straight-forward user interface and soft-key menus, the Fluke 572-2 makes even complex measurements easy. Quickly navigate and adjust emissivity, start data logging, or turn on and off alarms, with just a few pushes of a button.
Product highlights
With a rugged, easy-to-use, ergonomic design, the Fluke 575-2 can stand up to tough industrial, electrical, and mechanical environments.
Measure -30 °C to 900 °C
(-22 °F to 1652 °F) 60:1 distance to spot ratio with
dual laser sighting for fast, accurate targeting Multi-language interface
(user select) Current Temperature plus MAX,
MIN, DIF, AVG temperature displays Compatible with standard
mini-connector K-type ther­mocouples, including ones you already own and have installed. Adjustable emissivity and pre-
defined emissivity table Infrared and thermocouple
temperature on backlit display Last reading Hold (20 seconds)
High and low temperature
alarm Data storage and review (99
data sets) Tripod mount
12 or 24 hour clock
USB 2.0 computer interface
cable FlukeView® Forms Document-
ing Software Two-year warranty
Page 2
572-2 specifications
Infrared measurements
Infrared temperature range -30 °C to 900 °C (-22 °F to 1652 °F) IR accuracy (Calibration geometry with ambient
temperature 23 °C ± 2 °C)
IR Repeatability ± 0.5 % of reading or ± 0.5 °C (± 1 °F), whichever is greater Display Resolution 0.1 °C / 0.1 °F Distance:Spot 60:1 (calculated at 90 % energy) Minimum spot size 19 mm Laser sighting Offset dual laser, output <1 mW Spectral Response 8 μm to 14 μm Response Time (95 %) <500 ms Emissivity Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials
Measurement options
Hi/Low alarms Audible and two-color visual Min/Max/Avg/Dif Yes Switchable celsius and fahrenheit Yes Backlight Two levels, normal and extra bright for darker environments Probe input K-type thermocouple
Trigger lock Yes Data storage 99 points Display Dot matrix 98 x 96 pixels with function menus Communication USB 2.0
K-type thermocouple specifications
K-type thermocouple input temperature range -270 °C to 1372 °C (-454 °F to 2501 °F) K-type thermocouple input accuracy (with ambient
temperature 23 °C ± 2 °C)
K-type thermocouple resolution 0.1 °C/0.1 °F K-type thermocouple repeatability ± 0.5 % of reading or ± 0.5 °C (± 1 °F), whichever is greater Measurement range
(K-type thermocouple bead probe) Accuracy ± 1.1 °C (± 2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F). Typically within 1.1 °C (2.0 °F) from
Cable length 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector
General specifications
Operating temperature 0 °C to 50 °C (32 °F to 122 °F) Storage temperature -20 °C to 60 °C (-4 °F to 140 °F) Relative humidity 10 % to 90 % RH non-condensing up to 30 °C (86 °F) Operating altitude 2000 meters above mean sea level Weight 0.322 kg (0.7099 lb) Power 2 AA Batteries Battery life 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty
Safety and compliance IEC 60825-1
≥ 0 °C: ± 1°C or ± 1 % of the reading, whichever is greater ≥-10 °C to <0 °C: ± 2 °C <-10 °C: ± 3 °C
≥32 °F: ± 2 °F or ± 1 % of the reading, whichever is greater ≥14 °F to <32 °F: ± 4 °F <14 °F: ± 6 °F
Simultaneous display of probe and IR temperature
< -40 °C: ± (1 °C + 0.2 °/1 °C) ≥ -40 °C: ± 1 % or 1 °C, whichever is greater < -40 °F: ± (2 °F + 0.2 °/1 °F) ≥ -40 °F: ± 1 % or 2 °F, whichever is greater
-40 °C to 260 °C (-40 °F to 500 °F)
-40 °C to 0 °C (-40 °F to 32 °F)
and bead termination
cycle (thermometer continuously on)
FDA Laser Class II EMC 61326-1 CE Compliance CMC 沪制01120009
2 Fluke Corporation 572-2 Infrared Thermometer
Page 3
Recommended temperature probes
Probe Usage
80PK-1 The general purpose bead probe is for quick, accurate surface temperatures and air temperatures within ducts,
80PK-8 Pipe clamp probes (2) are essential for tracking continuously changing temperature differentials on hydronic
80PK-9 The insulation-piercing probe provides a sharp tip to pierce pipe insulation and flat probe tip for good surface
80PK-11 Flexible cuff thermocouple temperature probe is a convenient way to attach a thermocouple to a pipe while
80PK-25 The piercing probe is the most versatile option. Good for checking air temperature in ducts, surface temperature
80PK-26 The tapered probe is a good general-purpose gas and surface probe, with a good length and low mass tip casing
Ordering information
572-2 Infrared Thermometer
Includes
Infrared thermometer with contact thermometer capabilities, K-type thermocouple bead probe, USB
2.0 computer interface cable, FlukeView Documenting Software, hard carrying case, getting started guide (print) and user’s manual (CD).
vent temperatures.
tubing and pipe loops, and good for quick, accurate refrigerant temperatures.
thermal contact, air temperatures within ducts, and vent temperatures.
keeping hands free.
under carpets/pads, liquids, thermometer wells, vent temperatures, and for penetrating pipe insulation.
for faster reaction to surface and air temperatures.
®
Forms
3 Fluke Corporation 572-2 Infrared Thermometer
Fluke. The Most Trusted Tools in the World.
Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com
©2013 Fluke Corporation. Specifications subject to change without notice. Printed in U.S.A. 6/2013 6000240A_EN
Modification of this document is not permitted without written permission from Fluke Corporation.