Fluke 572 User Manual

572
Precision Infrared Thermometer
Users Manual
March 2005
© 2005 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies.
2
LIMITED WARRANTY AND LIMITATION
OF LIABILITY
This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contami­nation, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke’s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSE­QUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liabi­lity may not apply to you.
3
Warning
A Warning identifies conditions and actions that pose ha­zards to the user. To avoid electrical shock or personal injury, follow these guidelines:
Do not point laser directly at eye or indirectly off reflective surfaces.
• Before using the thermometer inspect the case. Do not use the thermometer if it appears damaged. Look for cracks or missing plastic.
• Replace the batteries as soon as the battery indicator two or less segments.
• Do not use the thermometer if it operates abnormally. Protection may be impaired. When in doubt, have the thermometer serviced.
• Do not operate the thermometer around explosive gas, vapor, or dust.
• Do not connect the optional external probe to live electrical circuits.
• To avoid a burn hazard, remember that highly reflective objects will result in lower than actual temperature measurements.
• Do not use in a manner not specified by this manual or the protection supplied by the equipment may be impaired.
Caution
To avoid damaging the thermometer or the equipment under test protect them from the following:
• EMF (electro-magnetic fields) from arc welders, induction heaters, etc.
• Static electricity
• Thermal shock (caused by large or abrupt ambient temperature changes- allow 30 minutes for thermometer to stabilize before use).
• Do not leave the thermometer on or near objects of high temperature.

Safety Information

4

Table of Contents

Introduction .................................................. 5
Symbols and Safety Markings ..................... 7
Laser Warning and Serial Number Labels .... 8
Delivery Content ........................................... 9
Functions and Display .................................. 10
Batteries and Measurement ......................... 11
Field of View and Emissivity ......................... 12
Spot Size ...................................................... 13
Emissivity ...................................................... 14
Mode and Setup Alarm ................................ 15
Graphic Display and DIP Settings ................ 16
DIP Switch Factory Settings ........................ 17
Troubleshooting ............................................ 18
Maintenance ................................................. 19
Emissivity Table (Selected Values) ................ 20
CE Conformity .............................................. 21
Specifications ............................................... 22
Factory defaults ............................................ 22
5
The Fluke Model 572 Infrared Thermometer (the thermometer) is for non-contact temperature measurement. This thermometer determines an object‘s surface temperature by measuring the amount of infrared energy radiated by the object‘s surface.
Contacting Fluke
To contact Fluke, call one of the following telephone numbers:
USA: 1-888-44-FLUKE (1-888-443-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 For USA Service: 1-888-99-FLUKE (1-888-993-5853)
Or, visit Fluke's Web site at www.fluke.com. To register your product, visit register.fluke.com.

Introduction

6
7
Symbol Explanation
Warning. Laser.

Symbols and Safety Markings

The laser sight simplifies
A
The laser automatically
turns of
f
trigger.
symbol
Loading...