FLUIDX GasCheck G Series User Manual

USER MANUAL
GASCHECK G SERIES
CONTACT US
PHONE/FAX
Phone: 801.486.1015 Fax: 801.486.1032
ADDRESS
FLUIDX Equipment, Inc. 139 W. 2260 S. Salt Lake City, UT 84115
www.uidxinc.com info@uidxinc.com
SMT-07-1015 rev B
ii
© 2018 FLUIDX Equipment, Inc.
CONTENTS
1. SCOPE .................................................................................... 1
2. SAFETY .................................................................................. 1
3. OVERVIEW ............................................................................ 2
4. BASIC OPERATION ............................................................12
5. MAINTENANCE .................................................................. 16
iii
© 2018 FLUIDX Equipment, Inc.
1. SCOPE
2. SAFETY
LACO USER MANUAL - GASCHECK G SERIES
This manual contains safety, operation, and maintenance information for GasCheck G Series handheld snier leak detector. Our leak detectors are designed to ensure safety when used properly. It is the responsibility of the user to follow safety-related warnings, cautions, notes, and other requirements described in this manual.
Should a question, comment or problem arise, the information below is provided as a guide. When returning a unit for factory service or calibration, contact Portable Leak Detectors for a return material authorization number (RMA). The device should be boxed securely and contain all contact information, including return shipping information. If the device is being sent to the factory for service, a written statement of the problem or symptoms should then be included. The RMA number must be on the outside of the package or indicated on the shipping label.
Please read this manual in full before using the GasCheck G Series instrument. Portable Leak Detectors takes no responsibility for damage, injury or death resulting from misuse, misunderstanding or negligence while using this gas detector. Please contact Portable Leak Detectors for clarication on any aspect of this manual that is not understood or for additional information.
2.1 QUALITY ASSURANCE
GasCheck G Series instruments are manufactured in compliance with ISO9001:2000, which ensures that the equipment supplied to the customer has been designed and assembled from traceable components, leaving Portable Leak Detectors calibrated to traceable standards.
2.2 RESPONSIBILITY OF USE
Many gases are hazardous and can cause explosion, poisoning and corrosion resulting in damage to property and life. It is the responsibility of the person using this instrument to ensure it is being used in accordance with this manual and that the instrument is functioning correctly before use.
The GasCheck G Series handheld leak detectors can detect a large range of gases but some gases are more dicult to detect. It is the responsibility of the user to ensure the GasCheck instrument has the sensitivity to detect the required gas before reaching potentially dangerous levels.
1
© 2018 FLUIDX Equipment, Inc.
3. OVERVIEW
LACO USER MANUAL - GASCHECK G SERIES
2.3 DISPOSAL
Disposal of the GasCheck G Series its, components, and any used batteries shall be in accordance with local and national safety and environmental requirements.
2.4 CALIBRATION
Calibration service is recommended on a yearly basis. LACO Technologies has an A2LA Accredited calibration lab which complies to ISO/IEC 17025­2005 and ANSI/NCSL Z540-1-1994. Also complies with ISO-9001 quality standard. Call LACO at 801-486-1004 for more information.
The GasCheck is a portable handheld gas detector instrument predominantly used for detecting gas leaks and can detect almost all gases to varying degrees. It is powered by standard AA size batteries and will accept both Alkaline and Nickel Metal Hydride (rechargeable) types.
The GasCheck uses thermal conductivity as its means of detecting gas which oers a robust sensor technology that requires practically no maintenance beyond annual servicing.
All GasCheck G Series models have an easy to use graphical interface with an intuitive keypad allowing simple function selection and adjustment. It can be upgraded to add features without the need to be returned to the supplier and without having to modify the internal rmware. It has an LCD display, LED indicator and audible sounder than indicates the detected signal.
Table 1: GasCheck Specications
COMPONENT DESCRIPTION
TEMPERATURE
STORAGE TEMPERATURE
INSTRUMENT CASE
DIMENSIONS
WEIGHT
INGRESS RATINGS
0 to 50° C (32 to 122° F)
-25 to 70° C -(13 to 158° F)
Polyurethane
L.390 x W.60 x H.50mm L (15.35” x W2.35” x 2.0”)
0.5 kg (1.0 lb)
IP20
LENGTH OF LONG PROBE
DETECTION TYPE
DETECTION TIME TO T90
CLEAR DOWN TIME
BATTERY TYPE
BATTERY LIFE AT 20°C (68°F)
2
© 2018 FLUIDX Equipment, Inc.
300 mm *12”)
Thermal conductivity
1 sec (short probe) 9 sec (long probe)
1 sec (short probe) 9 sec (long probe)
Alkaline or NiMH AA (qty 4)
40 hours (20 hours when using the backlight
LACO USER MANUAL - GASCHECK G SERIES
Table 2: GasCheck Replacement Parts
PART NUMBER DESCRIPTION
A-08045
A-08043
1/BH-01
08024CPC8
A-08029
CM515.0-4101FAG/1
CM515.0-410SFA0/1
Long probe
Short probe
Replacement battery holder
Nozzle
Box Wrench
Leak Standard with Rellable Helium Reservoir, 5x10-4 cc/sec
Open Style Leak Standard for use with helium regulator and tank, 5x10^-4 cc/sec
3.1 APPLICATIONS
Common applications include:
• Quality assurance: Testing seal integrity after product manufacture
• Laboratory applications: Detection of leaks from mass spectrometers and chromatograph equipment
• Industrial: Leaks from gas cylinders, pipe work and process equipment
• Medical: Testing of membrane materials and sealing of glove boxes
• Pneumatic: Valve seal testing.
3.2 UNITS OF MEASUREMENT
The GasCheck is calibrated against a 5 E-4/cc/s helium leak to allow volumetric readings and also a 5000ppm helium to allow measurement of concentrations.
Table 3: Selectable Units of Measurement
UNIT DESCRIPTION
cc/sec Cubic Centimeters per Second oers a reading that indicates
the volume of gas escaping into atmosphere from a single point, i.e., leakage from a hold in a gas lled vessel or pipe.
ppm Parts Per Million is a concentration reading. The GasCheck G
will display the concentration being detected. However, it is more dicult to gauge the quantity of leakage.
mg/m3 Milligrams per meter cubed is also a unit that measures
concentration. (See ppm above)
g/yr Grams per Year is an alternative measure leak rate.
3
© 2018 FLUIDX Equipment, Inc.
LACO USER MANUAL - GASCHECK G SERIES
3.3 IMPORTANT NOTES
The GasCheck G Series range is NOT intrinsically safe, so it should not be used in potentially explosive environment. Intrinsically safe GasCheck instruments are available; please contact Portable Leak Detectors for more information.
• Ambient air pressure, heat, and humidity can also aect readings.
• The GasCheck G range is NOT “gas specic”, i.e., it cannot dierentiate between gases.
3.4 PACKING LIST
Please remove all packing material and then check the content of the carry case against the list below before use. Should the instrument or any accessory appear damaged or missing, contact the instrument supplier for advise before use.
Table 4: Packing List
ITEM QTY DESCRIPTION CHECK
1 1 GasCheck G instrument w/short probe and nozzle tted
2 1 Long Probe
3 1 Box wrench to change probe
4 1 Spare battery clip
5 1 User manual
6 1 Calibration certicate
7 1 CD containing additional product information