Flowline LH29 Specifications

Page 1
Switch-Tek LH29 Interstitial Leak Detection Switch
Application
The general purpose oat leak switch provides reliable leak detection in and around secondary containment sumps and tanks with a 1A relay output. The at body Valox leak sensor is ideal for placement in hard to reach interstitial areas with limited space.
Switch Open
Switch Closed
In the event of a leak, the foam polypropylene oat will rise to signal the presence of unwanted liquid in the containment vessel. The leak detection switch is typically mounted at on the bottom of the sump oor or secondary containment tank wall.
®
Features
Valox sensor body with PP oat and Halar® jacketed
cable for corrosive liquids
Flat, low prole sensor with minimal oat rise for
applications with limited space
Dry contact, normally closed reed switch opens to
signal the presence of liquid
Compatible Products
Key Benets
Easy to install
Ideal for double wall tanks or pipes
Used to signal the presence of liquid leaks or
overow in any containment area
Switch-Pro
Remote Level Controller
LC4X
© 2010 Flowline Inc. • 10500 Humbolt Street Los Alamitos, CA 90720 • 562.598.3015 • www.owline.com • DSLH29 REV A
Application
Available in general purpose classication, the level controller is offered in three congurations for pump and valve control. The LC40 accepts one level sensor input and provides one 10A relay. The LC41 accepts two level sensor inputs and provides one latching 10A relay for automatic ll or empty control. The LC42 accepts three level sensor inputs with one latching 10A relay output for automatic ll or empty control, and a second non-latching 10A relay for high level alarm or low level alarm. For eld mount installation, add a single or dual indicator NEMA box.
Page 2
Switch-Tek LH29 Interstitial Leak Detection Switch
LH29-1001
3.00"
(76.2)
1.50"
(38.1)
0.375" (9.53)
10' Cable Leads
Switch Housing
Float
Pivot Pin
Attach String Here to Pull Through Tank
.75" REF
(19.1)
®
Specications
Orientation: Horizontal
Contact type: (1) SPST reed
Contact state: NC, Open on rise
Contact rating: 30 watts
240 VAC (0.14 amps resistive)
120 VAC (0.28 amps resistive)
120 VDC (0.07 amps resistive)
24 VDC (0.28 amps resistive)
Contact output: NC (opens on rise)
Process temp.: F: -40° to 221°
C: -40° to 105°
Pressure: 50 psi (3.44 bar)
Float material: Foamed polypropylene
Body material: Valox 420
Dimensions
Accessories
Protect your level controller from the elements by using the below recommended single or two controller NEMA box.
P/N Description
Single & Two Controller NEMA Box
LM94-1001 Single Controller, Windowed, 35mm Rail, Polycarbonate
LM95-1001 Two Controller, Windowed, 35mm Rail, Polycarbonate
Pivot pin: Stainless steel
Wire type: 2 conductor, #22 AWG
Wire length: 10’ (3.04m)
Wire jacket mat: Halar jacketed
Classication: General purpose
Compliance: CE
Approvals: UL
Ordering
© 2010 Flowline Inc. • 10500 Humbolt Street Los Alamitos, CA 90720 • 562.598.3015 • www.owline.com • DSLH29 REV A