Switch-Tek LH29 Interstitial Leak Detection Switch
™
Application
The general purpose oat leak switch provides
reliable leak detection in and around secondary
containment sumps and tanks with a 1A relay output.
The at body Valox leak sensor is ideal for placement
in hard to reach interstitial areas with limited space.
Switch Open
Switch Closed
In the event of a leak, the foam polypropylene oat
will rise to signal the presence of unwanted liquid in
the containment vessel. The leak detection switch is
typically mounted at on the bottom of the sump oor
or secondary containment tank wall.
®
Features
Valox sensor body with PP oat and Halar® jacketed •
cable for corrosive liquids
Flat, low prole sensor with minimal oat rise for •
applications with limited space
Dry contact, normally closed reed switch opens to
signal the presence of liquid
Compatible Products
Key Benets
Easy to install •
Ideal for double wall tanks or pipes •
Used to signal the presence of liquid leaks or •
overow in any containment area
Switch-Pro™
Remote Level Controller
LC4X
© 2010 Flowline Inc. • 10500 Humbolt Street Los Alamitos, CA 90720 • 562.598.3015 • www.owline.com • DSLH29 REV A
Application
Available in general purpose classication, the level controller is offered in three
congurations for pump and valve control. The LC40 accepts one level sensor input
and provides one 10A relay. The LC41 accepts two level sensor inputs and provides
one latching 10A relay for automatic ll or empty control. The LC42 accepts three
level sensor inputs with one latching 10A relay output for automatic ll or empty
control, and a second non-latching 10A relay for high level alarm or low level alarm.
For eld mount installation, add a single or dual indicator NEMA box.

Switch-Tek LH29 Interstitial Leak Detection Switch
3.00"
(76.2)
1.50"
(38.1)
0.375" (9.53)
10' Cable
Leads
Switch
Housing
Float
Pivot Pin
Attach String
Here to Pull
Through Tank
.75" REF
(19.1)
™
®
Specications
Orientation: Horizontal
Contact type: (1) SPST reed
Contact state: NC, Open on rise
Contact rating: 30 watts
240 VAC (0.14 amps resistive)
120 VAC (0.28 amps resistive)
120 VDC (0.07 amps resistive)
24 VDC (0.28 amps resistive)
Contact output: NC (opens on rise)
Process temp.: F: -40° to 221°
C: -40° to 105°
Pressure: 50 psi (3.44 bar)
Float material: Foamed polypropylene
Body material: Valox 420
Dimensions
Accessories
Protect your level controller from the elements by using the below
recommended single or two controller NEMA box.
P/N Description
Single & Two Controller NEMA Box
LM94-1001 Single Controller, Windowed,
35mm Rail, Polycarbonate
LM95-1001 Two Controller, Windowed,
35mm Rail, Polycarbonate
Pivot pin: Stainless steel
Wire type: 2 conductor, #22 AWG
Wire length: 10’ (3.04m)
Wire jacket mat: Halar jacketed
Classication: General purpose
Compliance: CE
Approvals: UL
Ordering