Flowline FT10-1305, FT10-1405, FT10-5305, GT10-5405, GT10-5305 Instruction Manual

...
Warranty, Service & Repair
WARRANTY
Flowline warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service for a period which is equal to the shorter of one year from the date of purchase of such products or two years from the date of manufacture of such products.
This warranty covers only those components of the products which are non-moving and not subject to normal wear. Moreover, products which are modified or altered, and electrical cables which are cut to length during installation are not covered by this warranty.
Flowline’s obligation under this warranty is solely and exclusively limited to the repair or replacement, at Flowline’s option, of the prod­ucts (or components thereof) which Flowline’s examination proves to its satisfaction to be defective. FLOWLINE SHALL HAVE NO OBLIGATION FOR CONSEQUENTIAL DAMAGES TO PERSON­AL OR REAL PROPERTY, OR FOR INJURY TO ANYPERSON.
This warranty does not apply to products which have been subject to electrical or chemical damage due to improper use, accident, negli­gence, abuse or misuse. Abuse shall be assumed when indicated by electrical damage to relays, reed switches or other components. The warranty does not apply to products which are damaged during ship­ment back to Flowline’s factory or designated service center or are returned without the original casing on the products. Moreover, this warranty becomes immediately null and void if anyone other than ser­vice personnel authorized by Flowline attempts to repair the defective products.
Products which are thought to be defective must be shipped prepaid and insured to Flowline’s factory or a designated service center (the identity and address of which will be provided upon request) within 30 days of the discovery of the defect. Such defective products must be accompanied by proof of the date of purchase.
Flowline further reserves the right to unilaterally wave this warranty and to dispose of any product returned to Flowline where:
a. There is evidence of a potentially hazardous material present
with product.
b. The product has remained unclaimed at Flowline for longer than
30 days after dutifully requesting disposition of the product.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS WARRANTY. This warranty and the obligations and liabilities of Flowline under it are exclusive and instead of, and the original purchaser hereby waives, all other remedies, warranties, guarantees or liabilities, express or implied. EXCLUDED FROM THIS WARRANTY IS THE IMPLIED WARRANTY OF FITNESS OF THE PRODUCTS FOR A PARTIC­ULAR PURPOSE OR USE AND THE IMPLIED WARRANTY OF MERCHANT ABILITY OF THE PRODUCTS.
This warranty may not be extended, altered or varied except by a writ­ten instrument signed by a duly-authorized officer of Flowline, Inc.
®
Version 0.4A © 2007 FLOWLINE Inc. All rights reserved. Manual # FT900003 09/07
Thermo-Flo™ Flow Switches FT10 and GT10 Series Owner’s Manual
To register your product with the manufacturer, go to the Flowline website for on-line registration. The website address is as follows:
www.flowline.com
On-line Warranty Registration can be found under Contact Flowline on the Navigation Bar along the side of the home page.
If for some reason your product must be returned for factory service, go to the Flowline website listed above. Online Factory Service can be found under Contact Flowline on the Navigation Bar along the side of the home page. Click on Return Authorization to begin the registration process. You will need the following information at the time of registration:
1. Part Number and full Serial Number from product
2. Name and telephone number of someone who can answer technical questions related to the product and its application.
3. Return Shipping Address
4. Brief Description of the Symptom
5. Brief Description of the Application
Once you have received a Material Return Authorization number, ship the product prepaid in its original packing to:
Flowline Factory Service MRA _____ 10500 Humbolt Street Los Alamitos, CA 90720
To avoid delays in processing your repair, write the MRA on the shipping label. Please include the information about the malfunc­tion with your product. This information enables our service tech­nicians to process your repair order as quickly as possible.
I
P
68
Step One
SPECIFICATIONS
Common Specifications:
175 150 125 100 075 050 025 000
00 20 40 60 80 100
Acceptable
Range
Unacceptable
Range
Temperature/Pressure Derating
Operating Pressure (psi)
Temperature (Cß)
PVDF PP
Thermo-Flo Ultrasonic Level Switch, FT10 Series
* all dimensions are Nominal
10
6
10
5
10
4
10
3
10
2
10
1
1
10
-1
1 10 100 150 1000
12" 8" 6" 4" 3" 2"
1" 3/4" 1/2"
90
GT10 Rate vs Velocity
Flow Rate (cfm)
Velocity (fps)
1000
100
10
1
0.1
0.01 .01 .04 .1 .2 1 3 10
6" 4"
3" 2" 1-1/2"
1" 3/4"
1/2"
12" 10" 8"
FT10 V olume vs Velocity
Flow Rate (gpm)
Velocity (fps)
Set Points:
The FT10 liquid flow switch set point is factory calibrated to
0.2 fps and the GT10 gas flow switch is set to 10 fps. To con­vert feet/sec to GPM, please refer to the chart below.
Set point range:
Factory set point:
Repeatability:
Response time: Set point adjust.: Viscosity range:
(FT10 only) Supply voltage: Consumption: Contact type: Contact rating: Contact output: Process temp.:
Electronics temp.:
Pressure:
Sensor rating: Sensor material:
Cable jacket mat.:
Cable type:
Cable length:
Process mount: Mount. gasket: Classification: CE compliance:
FT10: .04 to 3 fps
GT10: 1 to 90 fps
FT10: .2 fps (.06 mps) GT10: 10 fps (3 mps)
±
.5% of set point @ fixed temp. 1-10 seconds Potentiometer 1-200 centipoise
12-36 VDC 70 mA maximum (1) SPST relay 60 VA Selectable NO/NC F: 32˚ to 140˚ C: 0˚ to 60˚ F: -40˚ to 140˚ C: -40˚ to 60˚ 150 psi (10 bar) @ 25˚ C., derated @ 1.667 psi (.113 bar) per ˚C. above 25˚ C. NEMA 4X (IP65) 1__5: PP-Ryton® 5__5: PVDF Kynar® 1__5: PP 5__5: FEP Teflon® 4-conductor, #22 AWG (shielded) Standard: 10' (3m) Special order: 25' (7.6m) or 50' (15.2m) 3/4" NPT (3/4" G / R) Viton® (G version only) General purpose EN 61326 EMC EN 61010-1 safety
(.012 to .91 mps)
(.3 to 27 mps)
Thermo-Flo Switch
_T10 - _ _ _ 5
Medium F - Liquid G - Gas Sensor Material
1 - PP 5 - PVDF
Sensor Length
3 - Short 4 - Long
Mounting Thread
0 - 3/4" NPT 2 - 3/4" ISO
10’ Cable (3m)
10’ Cable (3m)
3/4" NPT (G 3/4")3/4" NPT (R 3/4")
0.7"
(19mm)
2.1"(54mm)
3/4" NPT (R 3/4")3/4" NPT (R 3/4")
0.7"
(19mm)
1.3"(32mm)
2.8"(71mm)
0.7"
(19mm)
4.5"(114mm)
3.0"(76mm)
Ambient Sensor Temperature (Cß)
Maximum T emperature/Volta ge
Derating @ Maximum Current
100
80 60 40 20 00
12 18 24 30 36
Acceptable
Operating Voltage (VDC)
Unacceptable
Range
Range
Flowline Electrical Loading Limits
1,400 1,200 1,000
800 600 400 200
0
Max. Series Resistance (Ohms)
Unacceptable
Range
Acceptable
Range
12 18 24 30 36
Supply Voltage (VDC)
Loading...